Spectroscopy Instruments
Filter
Showing 1711–1740 of 2628 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RSL-Plus |
| Pricing | Available Upon Request |
| Brand | Ruihai Photonics (Oceanhood) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PL980 |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Spectral Resolution | ~4 nm @ 25 µm slit |
| Wavelength Accuracy | ≤3% peak-to-peak (@ 2 hrs) |
| Excitation Wavelength | 976 ± 3 nm, Linewidth < 0.2 nm |
| Laser Power Stability | ≤3% P-P (@ 2 hrs) |
| Laser Lifetime | 10,000 hrs |
| Output Power Range | 0–500 mW adjustable |
| Optical Density (OD) of Notch Filter | OD8 |
| Probe Working Distance | 7.5 mm |
| Probe Fiber Length | ~1.5 m |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 5–80% RH |
| Excitation Fiber Core | 105 µm VIS-NIR |
| Emission Collection Fiber Core | 200 µm VIS-NIR |
| Spectral Range | 1000–1700 nm |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | S22 |
| Price | USD 72 (FOB Shanghai) |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 340–1000 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Stray Light | ≤0.3% T |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | S3 |
| Price Range | USD 65,000–130,000 |
| Operating Principle | Filter-Based |
| Imaging Method | Filter-Based |
| Deployment Mode | Airborne |
| Image Resolution | 12 Megapixel (4000 × 3000 px) |
| Sensor Size | 6.20 × 4.65 mm |
| Pixel Pitch | 1.55 µm |
| Image Format | RAW (12-bit) + JPG (8-bit) |
| Lens Options | S3W (87° HFOV, f/3.0, 19 mm equiv.) or S3N (41° HFOV, 2× optical fixed zoom, f/3.0, 19 mm equiv.) |
| Distortion | <1% extreme low distortion (non-fisheye) |
| Focal Length | 8.25 mm |
| Ground Sampling Distance (GSD) | 2.3 cm/px at 120 m AGL |
| Capture Interval | 1.5 s (JPG), 2.75 s (RAW+JPG) |
| Trigger Interface | PWM via HDMI port |
| Storage | MicroSD (64 GB or 128 GB) |
| Weight | 50 g (body only), 76 g (with battery) |
| Dimensions | 59 × 41.5 × 36 mm (L × H × W) |
| Power Input | 5.2 V, 0.2 A (USB-powered), 5.2 V, 0.4 A (battery-powered) |
| Battery | Removable Li-ion, 1200 mAh |
| Display | 2.0″ ultra-bright color touchscreen LCD |
| Video Output | HD 1080p (HDMI micro), SD 480p (optional USB FPV cable) |
| Exposure Control | Auto, manual shutter (1/2000–60 s), ISO 50–400, exposure compensation ±2.0 in 1/3-stop increments |
| White Balance Modes | Auto, Daylight, Cloudy, Tungsten, Fluorescent, Blue, Light Blue, Red, Light Red, Custom |
| Color Profiles | Normal, B&W, Sepia, Vivid |
| Sharpness | Strong, Medium, Soft |
| Shooting Modes | Single, 3-sequence, 10-sequence |
| OSD | On/Off |
| Date Stamp | On/Off |
| Audio | On/Off |
| Quick Capture | On/Off |
| Auto Power-Off | Off, 1/3/5/10/15/30/60 min |
| LCD Sleep Timer | 1/3/5 min, Off |
| Vertical Flip | On/Off |
| Included Accessories | USB GPS receiver, battery, lens cap, USB charge cable, user manual |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable |
| Instrument Category | Fourier Transform |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | 0.01 cm⁻¹ |
| Scan Speed | 1 scan per 60 seconds |
| Signal-to-Noise Ratio (SNR) | 45,000:1 |
| Wavenumber Accuracy | ≤0.5 cm⁻¹ |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Instrument Type | Portable Handheld Raman Spectrometer |
| Model | AT-RS200 |
| Spectral Range | 200–3200 cm⁻¹ (Raman), 190–1100 nm (UV-Vis) |
| Spectral Resolution | ≤1 cm⁻¹ (Visible Raman), ≤2 cm⁻¹ (UV Raman) |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | ≤±0.15 cm⁻¹ |
| Detection Modalities | Surface-Enhanced Raman Scattering (SERS), UV-Vis Absorption Spectrophotometry, Colloidal Gold Immunochromatographic Assay (CGIA) |
| Total Assay Coverage | ~600 analytes across food safety, environmental monitoring, and veterinary medicine |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelength | 785 nm |
| Spectral Range | 200–3350 cm⁻¹ |
| Spectral Resolution | 4.5–10 cm⁻¹ (best ≤4.5 cm⁻¹ at 912 cm⁻¹) |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.15 cm⁻¹ |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHGGP-90A |
| Operating Principle | Pushbroom Scanning |
| Imaging Method | Dispersive (Prism-Grating Hybrid) |
| Platform | UAV-Mounted |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | ≤2 nm FWHM @ 546.1 nm |
| Spatial Resolution (IFOV) | 0.1 m at 300 m AGL |
| Image Resolution | 1000 × 1200 pixels |
| Total Field of View (TFOV) | ≥20° |
| Max Operational Altitude | 500 m AGL |
| Onboard Power | Integrated LiPo Battery with Extended Flight Duration |
| Environmental Certification | Certified by China National Environmental Monitoring Centre (CNEMC) and China Environmental Protection Industry Association (CEPIA) |
| Data Processing | End-to-end pipeline including radiometric calibration, atmospheric correction, spectral unmixing, and empirical/semi-analytical inversion algorithms for water quality parameters |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHGGP-90B |
| Operating Principle | Pushbroom Scanning |
| Imaging Method | Dispersive (Prism/Grating-based) |
| Deployment Mode | Ground-Based Fixed Tower Mount |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | ≤2 nm FWHM @ 546.1 nm |
| Total Field of View (TFOV) | ≥20° |
| Instantaneous Field of View (IFOV) | 0.08 m (at 50 m installation height, 30° tilt angle) |
| Spectral Bands | >200 channels |
| Real-Time Processing Capability | Yes |
| Water Parameter Retrieval | ≥15 parameters (e.g., TSS, Turbidity, Secchi Depth, Zn, Cu, Pb, Chlorophyll-a, COD, DO, TP, TN, NH₃-N) |
| Data Transmission | Multi-destination upload support |
| Calibration | Onboard solar tracking + electronic white-board radiometric calibration |
| Software Modes | Scanning Imaging Mode & Fixed-Point Monitoring Mode |
| Georeferencing | Manual ROI-based water body delineation |
| Data Integration | Manual lab sample import for post-acquisition spectral calibration |
| Brand | SAMA |
|---|---|
| Origin | Japan |
| Model | S-7010 |
| Instrument Type | Portable |
| Principle | Multi-channel Fourier Transform NIR |
| Wavelength Range | 700–1050 nm |
| Scan Speed | 1 s per spectrum |
| Data Sampling Interval | 3 s |
| Measurement Time | 2–3 s per sample |
| Chemometrics Software | S-7010 Software |
| Light Source | Halogen lamp (avg. lifetime: 40,000 h) |
| Detector | 16-bit ADC |
| Interface | USB 2.0 |
| Power Supply | 6 × rechargeable AA batteries |
| Operating Time | ~1 h |
| Dimensions (W×H×D) | 296 × 98 × 233 mm |
| Weight | 5.3 kg |
| Application Scope | Academic research & QC in meat science, food chemistry, and agricultural laboratories |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | B1000 |
| Price Range | USD 1,400–2,800 |
| Optical Design | Dual-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–700 nm |
| Wavelength Automation | Automatic |
| Spectral Bandwidth | <5 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.2% |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | ELSD3300 |
| Light Source | 650 nm, 30 mW laser |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 650 nm |
| Optical Design | Dual-beam |
| Spectral Bandwidth | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.01% |
| Baseline Noise | ≤0.01 mV |
| Baseline Drift | ≤0.2 mV / 30 min |
| Detection Limit | 0.5 ng |
| Quantitative Repeatability | ≤1.5% |
| Dynamic Range | 10⁴ (fixed gain) |
| Nebulizer Temp. Range | RT–56 °C (1 °C step) |
| Evaporator Temp. Range | RT–150 °C (1 °C step) |
| Temp. Control Accuracy | ±1 °C |
| Gas Supply | Clean air or nitrogen (2–5 bar) |
| Gas Flow Control | Mass flow controller (accuracy ±0.02 L/min) |
| Mobile Phase Flow Rate | 0.01–3 mL/min |
| Analog Output | −1200 to +1200 mV |
| Gain Adjustment | 0.3–30 (continuous) |
| Sampling Rate | 100 Hz (digital), 20 Hz (analog) |
| Dimensions (W×H×D) | 26 × 19 × 46 cm |
| Weight | 10 kg |
| Power | 85–264 VAC, 50 Hz |
| Compliance | CE-marked |
| Communication Interfaces | RS-232, RS-485, USB, LAN (TCP/HTTP) |
| Software Compatibility | Sanotac proprietary chromatography software |
| Origin | Sweden |
|---|---|
| Distribution Model | Authorized Distributor |
| Origin Category | Imported |
| Model | 450S |
| Price Range | USD 13,500 – 27,000 (FOB) |
| Brand | ScanSci |
|---|---|
| Wavelength Range | UV (200–600 nm), UV-VIS (250–800 nm), VIS (400–850 nm), VIS-NIR (500–1000 nm) |
| Grating Blaze Wavelength | 300 nm / 400 nm / 500 nm / 750 nm |
| Optical Resolution (FWHM) | <2.5 nm (with 50 µm slit) |
| Integration Time | 1 ms – 30 s |
| Detector Type | CCD |
| Warranty | 2 years (non-human-induced failure) |
| Brand | SciAps |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Z-903 |
| Instrument Type | Handheld |
| Integration | Fully Integrated |
| Spectral Range | 190–950 nm |
| Detection Capability | H to U (All Elements) |
| Weight | 1.97 kg (4.35 lb) |
| Dimensions | 273 × 73 × 219 mm (10.75 × 2.875 × 8.625 in) |
| Operating System | Android™ (ARM Quad-Core Cortex-A53, 1.2 GHz) |
| Memory | 2 GB LPDDR3 RAM + 16 GB eMMC internal storage |
| Data Storage | 32 GB microSD card |
| Display | 3.5-inch high-brightness color touchscreen (rear-mounted) |
| Laser Class | Class 3B |
| Safety Compliance | CE, RoHS, US FDA Registered |
| Environmental Control | Integrated Opti-Purge™ argon purge system |
| Calibration Reference | Onboard 316 stainless steel validation standard |
| Grade Libraries | >500 preloaded alloy/geochemical libraries, user-editable and multi-library support |
| Connectivity | Wi-Fi (802.11b/g/n), Bluetooth BR/EDR + BLE, GPS, USB-C |
| Power | Rechargeable Li-ion battery (internal & external charging), AC adapter compatible |
| Sample Alignment | Integrated coaxial laser targeting + dual-camera system (wide-field + macro) |
| Drift Correction | Onboard auto-drift correction using factory or user-defined reference materials |
| Software | SciAps AnalyzAR™ suite with spectral comparison, quantitative calibration curve generation, and full parameter control (laser firing pattern, spectrometer integration time, lens cleaning protocol) |
| Brand | Sciencetech |
|---|---|
| Origin | Canada |
| Model | 9030 Series |
| Spectral Range | 250–700 nm |
| Stray Light | 1.00E−03 |
| Grating Configuration | Dual Grating (Subtractive Mode) |
| Focal Length | 100 mm (Input & Output) |
| Optical Layout | Seya-Namioka |
| Grating Type | Concave Holographic |
| f-number | f/3.2 |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.25 nm |
| Slit Options | Removable fixed-width slits (100 µm to 3 mm) |
| Detector Interface | Single-channel PMT-compatible output |
| Software Control | USB 2.0 (motorized version only) |
| Compliance | Designed for GLP/GMP-aligned spectroscopic workflows requiring traceable wavelength calibration and audit-ready operation |
| Brand | SCINCO |
|---|---|
| Origin | South Korea |
| Model | Lumilux 5100 |
| Excitation/Emission Spectral Bandwidth | ≤ ±0.5 nm |
| Signal-to-Noise Ratio | > 1000:1 |
| Light Source | 150 W Xenon Arc Lamp |
| Detection Range | 190–900 nm |
| Detector Type | Photomultiplier Tube (PMT) |
| Brand | SCINCO |
|---|---|
| Origin | South Korea |
| Model | NanoVelox |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ≤ ±1 nm |
| Sample Volume (Cuvette Mode) | 0.5 µL |
| dsDNA Quantification Range | 2–27,500 ng/µL |
| BSA Quantification Range | 0.06–820 mg/mL |
| Measurement Time | < 8 seconds per sample |
| Operation | Standalone touchscreen interface with internal storage |
| Brand | SCINCO |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Velox 1100 |
| Price Range | USD 21,000–35,000 (FOB) |
| Optical Design | Single-Beam |
| Detector | 512-Element Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | <0.02 nm |
| Photometric Range | –3.0 to +3.0 Absorbance Units (AU) |
| Light Source | Xenon Arc Lamp |
| Spectral Bandwidth | Fixed, Optimized for PDA Architecture |
| Data Acquisition Speed | Full-spectrum acquisition in <100 ms |
| Brand | SCINCO |
|---|---|
| Origin | South Korea |
| Model | VMS-1S |
| Optical Configuration | Single-beam |
| Detector | 1024-element photodiode array (PDA) |
| Wavelength Range | 400–1000 nm |
| Wavelength Accuracy | ±1.5 nm |
| Wavelength Repeatability | ±0.2 nm |
| Scan Speed | 1 s per spectrum |
| Light Source | Tungsten halogen lamp |
| Sample Stage | Mechanical dual-layer XY stage (210 × 140 mm footprint |
| Eyepiece | Wide-field WF10× (20 mm field diameter) |
| Objective Lens | 5× |
| Measurement Modes | Transmittance and reflectance of small-area optical features (e.g., IR cut filters, camera aperture windows) |
| Brand | SEI |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SEI Field Spectroradiometer Accessories |
| Pricing | Upon Request |
| Brand | SEI |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | NaturaSpec |
| Spectral Range | 350–2500 nm |
| Detector | Dual-cooled InGaAs (SWIR1 & SWIR2) + UV-enhanced Si linear array |
| Resolution | 2.8 nm @ 700 nm |
| ENL | 0.3×10⁻⁹ W/cm²/nm/sr @ 700 nm |
| Detectors | 1024-pixel UV-enhanced Si (350–1000 nm), two 512-pixel thermoelectrically cooled InGaAs arrays (1000–1700 nm and 1700–2500 nm) |
| Weight | ~5.7 kg |
| Power | Rechargeable Li-ion battery |
| Brand | SEI |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | NaturaSpec Ultra |
| Spectral Range | 350–2500 nm |
| Detector Configuration | UV-enhanced Si (1024-pixel, TE-cooled, VIS-NIR), InGaAs (512-pixel, TE-cooled, SWIR1), Extended InGaAs (512-pixel, TE-cooled, SWIR2) |
| Spectral Resolution | 1.5 nm @ 700 nm |
| NER (1.2 m fiber) | 0.4×10⁻¹⁰ W/cm²/nm/sr @ 400 nm |
| Dimensions | 31.5 × 22.1 × 11.2 cm |
| Weight | 5.5 kg |
| Brand | SEI |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | OreX |
| Price Range | USD 85,000 – 170,000 |
| Spectral Range | 350–2500 nm |
| Brand | SEI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PSP-1100 |
| Instrument Type | Portable |
| Operating Principle | Fixed-grating array detector (non-scanning) |
| Wavelength Range | 320–1100 nm |
| Integration Time | 8–2000 ms |
| Sampling Interval | 1.5 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | DARWin SP |
| Optical Resolution | 3.2 nm (FWHM) |
| Stray Light | <0.05% @ 700 nm |
| Detector | 512-element silicon photodiode array (25 µm × 2.5 mm pixel size) |
| A/D Conversion | 16-bit |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.1 nm |
| NEΔL (400 nm, 1 s) | 8.0×10⁻¹⁰ W/cm²/nm/sr |
| NEΔL (700 nm, 1 s) | 7.0×10⁻¹⁰ W/cm²/nm/sr |
| NEΔL (900 nm, 1 s) | 1.5×10⁻⁹ W/cm²/nm/sr |
| Max Radiance @700 nm | 1.5×10⁻⁴ W/cm²/nm/sr |
| Input Port | 25° fiber optic coupling |
| Slit Width | 50 µm |
| Power Supply | Internal 2800 mAh rechargeable Li-ion battery (operating time >4 h) |
| Dimensions | 17.8 × 8.3 × 14.6 cm |
| Weight | <1.8 kg |
| Communication Interfaces | USB 2.0, Bluetooth 4.0 |
| Compliance | CE, FCC Part 15, RoHS |
| Brand | SEI |
|---|---|
| Origin | USA |
| Model | PSR-1100 / PSR-1100F |
| Spectral Range | 320–1100 nm |
| Spectral Resolution | 3.2 nm @ 600 nm |
| Sampling Bandwidth | 1.5 nm |
| Detector | 512-pixel Si CCD array (25 µm × 2.5 mm pixel size) |
| A/D Conversion | 16-bit |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.1 nm |
| Integration Time | 8–2000 ms |
| FOV Options | 4° (PSR-1100), 25° fiber-coupled (PSR-1100F) |
| IFOV | 1.5 mrad |
| Frame Rate | 50 fps |
| NEΔL (1 s) | 8.0×10⁻¹⁰ W/cm²/nm/sr @ 400 nm |
| Max Radiance | 1.5×10⁻⁴ W/cm²/nm/sr @ 700 nm |
| Built-in Rechargeable Battery | 2800 mAh (≥4 h operation) |
| Data Storage | 2500 spectra (standalone mode) |
| Communication | USB 2.0, Bluetooth 4.0 |
| Dimensions | 17.8 × 8.3 × 14.6 cm |
| Weight | <1.8 kg |
| Brand | SEI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PSR-1100f |
| Spectral Range | 320–1100 nm |
| Optical Resolution | 3.0 nm @ 600 nm |
| Internal Memory Capacity | 2500 spectra |
| Weight | <1.8 kg |
| Battery | Rechargeable 2800 mAh Li-ion, >4 hours continuous operation |
| Brand | SEI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PSR-1100f |
| Operating Principle | Push-broom Scanning |
| Imaging Method | Interferometric (Fourier-transform compatible optical architecture) |
| Deployment Mode | Ground-based |
| Wavelength Range | 320–1100 nm |
| Spectral Resolution | 3 nm @ 600 nm |
| Sampling Bandwidth | 1.5 nm |
| NEΔL (1 s integration) | 8.0×10⁻¹⁰ W/cm²/nm/sr @ 400 nm |
| Max Radiance | 1.5×10⁻⁴ W/cm²/nm/sr @ 700 nm |
| Slit Width | 50 µm |
| Detector | 512-element Si photodiode array, pixel size 25 µm × 2.5 mm |
| A/D Conversion | 16-bit |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Accuracy | ±0.5 nm |
| Integration Time | 8–2000 ms |
| Built-in Rechargeable Battery | 2800 mAh Li-ion |
| Onboard Storage | 2500 spectra (standalone mode) |
| Dimensions | 17.8 × 8.3 × 14.6 cm |
| Weight | 1.8 kg |
| Interface | USB 2.0, Bluetooth 4.2 |
| Brand | SEI |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | PSR+ |
| Spectral Range | 350–2500 nm |
| Spectral Resolution | 2.8 nm @ 700 nm |
| Weight (instrument only) | 3.5 kg |
| Weight (with battery) | 3.6 kg |
| Internal Memory Capacity | 1000 spectra |
| Power Supply | Two rechargeable Li-ion batteries, 7.4 V |
| Brand | SEI |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | RS-3500 |
| Spectral Range | 350–2500 nm |
| Spectral Resolution | 2.8 nm @ 700 nm |
| NEΔL (Noise-Equivalent Delta Radiance) | 0.8×10⁻⁹ W/cm²/nm/sr @ 700 nm |
| Weight | ~4 kg |
| Power | Dual removable Li-ion rechargeable batteries (4 h each) |
