Testing Machine
Filter
Showing 421–450 of 3402 results
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Model | M-200A2 |
| Instrument Type | Reciprocating Friction and Wear Tester |
| Maximum Friction Load | 392 N |
| Friction Torque Range | 0–4 N·m |
| Operating Temperature | Up to 100 °C |
| Specimen Dimensions | 30 mm × 7 mm × 6 mm |
| Rotational Speed | 0–200 rpm (adjustable) |
| Load Accuracy | ±0.5% FS |
| Torque Measurement Accuracy | ±1% FS |
| Speed Accuracy | ±1% |
| Counter Resolution | 1 s |
| Surface Finish of Counterface Ring | Ra ≤ 0.8 µm (▽8) |
| Counterface Material | 45# steel, quenched & tempered to HRC 40–45 |
| Counterface Geometry | Ø40 mm × 10 mm, 0.5 × 45° chamfer, concentricity < 0.01 mm |
| Brand | Guance Instruments |
|---|---|
| Model | MCTH-500.4 |
| Origin | Beijing, China |
| Instrument Type | Multi-Functional Tribological Tester |
| Maximum Friction Force Range | 30–150 N (via calibrated deadweight loading) |
| Operating Ambient Temperature | −30 to +40 °C |
| Relative Humidity | ≤85 % RH |
| Atmospheric Pressure | 80–120 kPa |
| Supply Voltage | 220 ±10 % VAC, 50 ±0.5 Hz |
| Total Power Consumption | 20 kW |
| Rotating Disc Diameter | 420 mm |
| Disc Rotational Speed | up to 2600 rpm |
| Slider Vertical Stroke | 100 mm |
| Slider Reciprocating Frequency | up to 90 cycles/min |
| Test Current Output | 0–500 A AC (5 V output) |
| Radial Runout Measurement | Integrated dial indicator (0–360° scale, micrometer resolution) |
| Data Acquisition | Real-time voltage, current, and rotational speed logging with Excel export |
| Dust Extraction System | 3 kW industrial vacuum unit |
| Dimensions (L×W×H) | 1500 × 1000 × 1700 mm |
| Weight | 600 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | NDH-AI3 |
| Quotation | USD 2,100 (FOB Beijing) |
| Instrument Type | Electromechanical Universal Testing Machine |
| Compliance Standards | IEC 60950-1:2001, BS EN 60950-1:2001, BS 7002:2000, GB 4943-2001, UL 746A, IEC 60947-1:1999, GB/T 14048.1-2000, IEC 730-1:1993, GB 14536.1-1998 |
| Control System | Siemens S7-1200 PLC |
| Human-Machine Interface | 10-inch resistive touchscreen with dynamic password login |
| Electrode Configuration | Static electrode — Cu, Ø3.2–3.5 mm, 30° chisel tip |
| Electrode Angle | 45° to horizontal plane |
| Test Voltage | 220 V AC / 50 Hz |
| Arc Current | 33 ± 5 A (adjustable) |
| Power Factor | cosφ = 0.5 ± 0.05 (adjustable) |
| Arcing Speed | 254 ± 25 mm/s |
| Arcing Frequency | 40 cycles/min (adjustable) |
| Arcing Cycles | Up to 200 (user-defined) |
| Specimen Dimensions | 130 mm × 13 mm × (2–12) mm |
| External Dimensions | 1250 mm (W) × 800 mm (D) × 1750 mm (H) |
| Rated Power | 10 kVA |
| Safety Features | Interlocked sliding door with limit switch, overload protection, audible alarm, tri-color tower lamp (green/amber/red), integrated exhaust fan with LED task lighting |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NDH-AI4 |
| Instrument Type | Electronic Universal Testing Machine |
| Rated Power | 10 kVA |
| Test Voltage | 220 V / 50 Hz |
| Arc Current | 33 ± 5 A (adjustable) |
| Power Factor | cosφ = 0.5 ± 0.05 (adjustable) |
| Arc Frequency | 40 cycles/min (adjustable) |
| Arc Speed | 254 ± 25 mm/s |
| Electrode Geometry | Static electrode — φ3.2–3.5 mm, 30° chisel tip |
| Electrode Angle | 45° to horizontal plane |
| Specimen Dimensions | 130 mm × 13 mm × (2–12) mm |
| Arc Cycles | Up to 200 (programmable) |
| Enclosure Dimensions | 1250 mm (W) × 800 mm (D) × 1750 mm (H) |
| Human-Machine Interface | 10-inch capacitive touchscreen |
| Control System | Siemens S7-1200 PLC |
| Safety Features | Interlocked sliding door, mechanical limit switches, overload protection, audible alarm, tower status lamp (green/red/yellow), integrated exhaust fan with LED illumination |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NDH-B2 |
| Instrument Type | Electronic Universal Testing Machine |
| Arc On/Off Time Accuracy | < ±1 ms |
| Voltage Regulation Capacity | 3 kVA |
| High-Voltage Transformer Capacity | 3 kVA, 0–20 kV Output |
| Rated Test Voltage | 12.5 kV |
| Voltage Accuracy | ±1% |
| Current Control Accuracy | ±3% |
| Current Measurement Accuracy | ±1.5% |
| Electrode Force on Specimen | (0.5 ± 0.05) N |
| Electrode Material | Tungsten Rod |
| Electrode Spacing | (6.35 ± 0.1) mm (IEC), (6.0 ± 0.1) mm (ASTM) |
| Ambient Temperature | (23 ± 2) °C |
| Ambient Humidity | (50 ± 5)% RH |
| Input Power | 220 V AC / 50 Hz |
| Output Voltage Range | 0–17.5 kV AC |
| Test Current Settings | 10, 20, 30, 40 mA |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NDH-B3 |
| Instrument Type | Electronic Universal Testing Machine |
| Arc On/Off Time Accuracy | < ±1 ms |
| Voltage Regulation Capacity | 3 kVA |
| High-Voltage Transformer Capacity | 3 kVA, 0–20 kV Output |
| Rated Test Voltage | 12.5 kV |
| Voltage Accuracy | ±1% |
| Current Control Accuracy | ±3% |
| Current Measurement Accuracy | ±1.5% |
| Electrode Force on Specimen | (0.5 ± 0.05) N |
| Electrode Material | Tungsten Rod |
| Electrode Spacing | (6.35 ± 0.1) mm (IEC), (6.0 ± 0.1) mm (ASTM) |
| Ambient Temperature | (23 ± 2) °C |
| Ambient Humidity | (50 ± 5)% RH |
| Input Power | 220 V AC / 50 Hz |
| Output Voltage Range | 0–17.5 kV AC |
| Test Current Settings | 10, 20, 30, 40 mA |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NDH-B4 |
| Instrument Type | Electronic Universal Testing Machine |
| Compliance Standards | GB/T 1411–2002, IEC 61621:1997, ASTM D495, IEC 149, UL 746A |
| Rated Test Voltage | 12.5 kV |
| Voltage Range | 0–17.5 kV AC |
| Current Range | 10–40 mA (selectable steps) |
| Arc On/Off Timing Accuracy | ±1 ms |
| Electrode Force | (0.5 ± 0.05) N |
| Electrode Material | Tungsten Rod |
| Electrode Spacing | (6.35 ± 0.1) mm (IEC), (6.0 ± 0.1) mm (ASTM) |
| Test Transformer Capacity | 3 kVA |
| Variac Capacity | 3 kVA |
| Voltage Regulation Accuracy | ±1% |
| Current Control Accuracy | ±3% |
| Current Measurement Accuracy | ±1.5% |
| Operating Environment | 23 ± 2 °C, 50 ± 5 % RH |
| Input Power | 220 V AC / 50 Hz |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NLD-AI3 |
| Instrument Type | Electronic Universal Testing Machine |
| Voltage Output | AC 100–8000 V / DC 100–8400 V |
| Electrical Capacity | 7 kVA |
| Electrode Spacing | (50 ± 0.5) mm |
| Electrode Material | 304 Stainless Steel |
| Test Specimens | 5 parallel channels |
| Voltage Drop | ≤5% |
| Input Power | AC 220 V, 50 Hz |
| Test Methods | Constant Voltage Method & Stepwise Voltage Method |
| Compliance | GB/T 6553–2003, IEC 60587:1984 |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NLD-AI4 |
| Instrument Type | Electronic Universal Testing Machine |
| Compliance | GB/T 6553–2003, IEC 60587:1984 |
| Output Voltage | AC 100–8000 V / DC 100–8400 V |
| Electrical Capacity | 7 kVA |
| Input Voltage | AC 220 V, 50 Hz |
| Voltage Drop | ≤5% at rated load |
| Electrode Spacing | (50 ± 0.5) mm |
| Electrode Material | 304 stainless steel |
| Electrode Mounting | Separated upper/lower electrode fixture with high-insulation, high-strength composite support |
| Sample Capacity | 5 specimens simultaneously |
| Droplet Control | Programmable peristaltic pump with real-time flow display |
| Leakage Current Alarm Range | 0–100 mA (user-configurable per channel) |
| Test Duration | User-defined (minutes) |
| Safety Interlock | Automatic HV cutoff upon door opening |
| Voltage Regulation | Autotransformer + oil-immersed step-up transformer |
| Calibration | Onboard voltage and current calibration function |
| Test Methods | Constant-voltage method, stepwise-voltage method |
| Ventilation System | Dedicated exhaust ducting for hazardous fume removal |
| Illumination | Integrated LED lighting for internal observation |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NLD-AI5 |
| Price | USD 1,950 (approx.) |
| Instrument Type | Electronic Universal Testing Machine |
| Standards Compliance | GB/T 6553–2003, IEC 60587:1984 |
| Test Method Modes | Constant Voltage Method, Stepwise Voltage Method |
| Voltage Supply | AC (48–62 Hz) and DC |
| Sample Channels | 5 independent parallel test circuits |
| Control System | Siemens PLC with optical isolation for voltage/current acquisition |
| Human Interface | 10-inch industrial touchscreen HMI |
| Leakage Current Alarm Range | 0–100 mA (user-configurable per channel) |
| Dropping System | Precision peristaltic pump with real-time flow display and on-screen adjustment |
| Voltage Regulation | Autotransformer + oil-immersed step-up transformer for low-voltage-drop stability |
| Safety Interlock | Door-open automatic high-voltage cutoff |
| Exhaust System | Dedicated fume extraction ducted outdoors |
| Illumination | Integrated LED internal lighting |
| Data Calibration | On-device voltage and current recalibration function |
| Test Duration Setting | Programmable (minutes) |
| Voltage Ramp & Reset | Auto-ramp to set voltage |
| Liquid Management | Separated fresh/drain reservoirs for contamination control |
| Real-time Monitoring | Per-channel voltage, instantaneous leakage current, peak leakage current, elapsed time |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NLD-AI6 |
| Instrument Type | Electronic Universal Testing Machine |
| Voltage Output | AC 100–8000 V / DC 100–8400 V |
| Electrical Capacity | 7 kVA |
| Input Power | AC 220 V / 50 Hz |
| Electrode Spacing | (50 ± 0.5) mm |
| Electrode Material | 304 Stainless Steel |
| Electrode Mounting | Separated upper/lower electrodes on high-insulation, high-strength composite brackets |
| Sample Capacity | 5 specimens simultaneously |
| Test Methods | Constant Voltage Method & Stepwise Voltage Method |
| Leakage Current Alarm Range | 0–100 mA (adjustable per channel) |
| Droplet Control | Programmable peristaltic pump with real-time flow display |
| Voltage Regulation | Autotransformer + oil-immersed step-up transformer (voltage drop ≤5%) |
| Safety Interlock | Door-open automatic high-voltage cutoff |
| Data Calibration | Onboard voltage and current calibration function |
| Compliance | GB/T 6553–2003, IEC 60587:1984 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NLD-AI7 |
| Instrument Type | Electronic Universal Testing Machine |
| Voltage Output | AC 100–8000 V / DC 100–8400 V |
| Electrical Capacity | 7 kVA |
| Input Power | AC 220 V, 50 Hz |
| Electrode Spacing | (50 ± 0.5) mm |
| Electrode Material | 304 Stainless Steel |
| Electrode Mounting | Dual independent high-insulation, high-strength composite支架 |
| Test Specimens | Up to 5 simultaneous samples |
| Test Methods | Constant Voltage Method & Stepwise Voltage Method |
| Drip Rate Control | Programmable per-channel via precision peristaltic pump |
| Leakage Current Alarm Range | 0–100 mA (user-configurable per channel) |
| Voltage Drop | ≤5% under load |
| Safety Interlock | Automatic HV cutoff upon door opening |
| Data Calibration | Onboard voltage/current recalibration function |
| Ventilation System | Dedicated exhaust duct with external venting capability |
| Illumination | Integrated LED interior lighting |
| Voltage Stabilization | Oil-immersed transformer + autotransformer regulation |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NLD-AII |
| Instrument Type | Electromechanical Universal Testing Machine |
| Input Voltage | AC 220 V |
| Output Voltage Range | AC 0–50 kV / DC −50–0 kV (adjustable) |
| Power Rating | 50 kVA |
| Voltage Accuracy | < ±2% |
| High-Voltage Output Current | ≥1 A |
| Current Measurement Accuracy | < ±1% |
| Spray Velocity at Specimen | 3 m/s |
| Salt Fog Generation | Ultrasonic atomizer |
| Fog Volume Concentration | (0.4 ± 0.1) L/m³·h |
| Fog Particle Size | 5–10 µm |
| Fog Chamber Volume | 4 m³ (2000 × 1200 × 1700 mm) |
| Specimen Mounting | 1 horizontal + 1 vertical position |
| Minimum Clearance | ≥400 mm from chamber ceiling and walls |
| Test Duration | Up to 1000 h continuous |
| Safety Interlock | Door-activated high-voltage cutoff and automatic voltage zeroing |
| Control System | Embedded industrial computer |
| Dimensions (L×W×H) | 3400 × 1300 × 1800 mm |
| Weight | 300 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NLD-AII.2 |
| Instrument Type | Electromechanical Universal Testing System |
| Input Voltage | AC 220 V |
| Output Voltage Range | AC 0–50 kV / DC −50–0 kV (adjustable) |
| Electrical Capacity | 50 kVA |
| Voltage Accuracy | < ±2% |
| High-Voltage Output Current | ≥1 A |
| Current Measurement Accuracy | < ±1% |
| Spray Velocity at Specimen | 3 m/s |
| Salt Fog Generation Rate | (0.4 ± 0.1) L/m³·h |
| 雾室 Volume | 4 m³ (L×W×H = 2000 × 1200 × 1700 mm) |
| 雾化 Particle Size | 5–10 µm |
| Specimen Mounting | 1 horizontal + 1 vertical |
| Minimum Clearance | ≥400 mm from ceiling and walls |
| Test Duration | 1000 h (continuous) |
| 雾化 Method | Ultrasonic Atomization |
| Salt Solution | NaCl + deionized water |
| Safety Interlock | Door-activated high-voltage cutoff & auto-zero reset |
| Control System | Embedded industrial computer |
| Dimensions (L×W×H) | 3400 × 1300 × 1800 mm |
| Weight | 300 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NLD-AII.3 |
| Instrument Type | Electronic Universal Testing Machine |
| Input Voltage | AC 220 V |
| Output Voltage Range | AC 0–50 kV / DC −50–0 kV (adjustable) |
| Electrical Capacity | 50 kVA |
| Voltage Accuracy | < ±2% |
| High-Voltage Output Current | ≥1 A |
| Current Measurement Accuracy | < ±1% |
| 雾室容积 | 4 m³ (L×W×H = 2000 × 1200 × 1700 mm) |
| Spray Velocity at Specimen | 3 m/s |
| Salt Fog Generation | Ultrasonic atomizer |
| Fog Density | (0.4 ± 0.1) L/m³·h |
| Droplet Size Distribution | 5–10 µm |
| Specimen Configuration | 1 horizontal + 1 vertical |
| Minimum Clearance | ≥400 mm (to ceiling and walls) |
| Test Duration | 1000 h (continuous) |
| Safety Interlock | Door-activated high-voltage cutoff and automatic zeroing |
| Control System | Embedded industrial computer |
| Dimensions (L×W×H) | 3400 × 1300 × 1800 mm |
| Weight | 300 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NLD-AII2 |
| Instrument Type | Electromechanical Universal Testing System |
| Input Voltage | AC 220 V |
| Output Voltage Range | AC 0–50 kV / DC −50–0 kV (adjustable) |
| Power Rating | 50 kVA |
| Voltage Accuracy | < ±2% |
| Current Output Capacity | ≥1 A (HV side) |
| Current Measurement Accuracy | < ±1% |
| Test Duration | Up to 1000 h continuous |
| Fog Chamber Volume | 4 m³ (L×W×H = 2000 × 1200 × 1700 mm) |
| 雾化颗粒Size | 5–10 µm |
| Salt Spray Rate | (0.4 ± 0.1) L/m³·h |
| Airflow Velocity at Specimen | 3 m/s |
| Specimen Spacing | ≥400 mm from ceiling and walls |
| Specimen Capacity | 1 horizontal + 1 vertical mounting position |
| Safety Interlock | Door-activated HV cutoff and automatic zeroing |
| Control System | Embedded industrial computer with real-time data logging |
| Dimensions (L×W×H) | 3400 × 1300 × 1800 mm |
| Weight | 300 kg |
| Brand | GuanCe Instruments |
|---|---|
| Model | NLD-BI3 |
| Type | Electronic Universal Testing Machine |
| Voltage Range | 100–600 V AC (48–60 Hz) |
| Electrode Material | 99% Pure Platinum (tips), Copper (holders) |
| Electrode Dimensions | (2.0 ± 0.1) mm × (5.0 ± 0.1) mm × (40 ± 5) mm |
| Electrode Tip Geometry | 12 mm length, 30° ± 2° bevel |
| Electrode Spacing | 4.00 ± 0.01 mm, 60° ± 5° included angle |
| Electrode Force | 1.00 ± 0.01 N |
| Test Solution Resistivity | A-solution: 3.95 ± 0.05 Ω·m (0.1% NH₄Cl) |
| B-solution | 1.98 ± 0.05 Ω·m |
| Droplet Height | 35 ± 5 mm (adjustable) |
| Droplet Interval | 30.00 ± 0.01 s (digital preset, 50-droplet time: 24.5 ± 2 min) |
| Droplet Count Range | 1–9999 (digital display & preset) |
| Airflow Velocity in Test Chamber | 0.2 m/s |
| Short-Circuit Current Threshold | 0.50 A ± 10%, sustained for 2.00 ± 0.2 s |
| Voltage Drop Limit | ≤8% at 1.0 ± 0.1 A load |
| Power Supply | 220 V, 0.6 kVA, 50–60 Hz |
| Ambient Operating Conditions | 0–40 °C, RH ≤80%, non-corrosive, low-vibration environment |
| Combustion Chamber Volume | >0.5 m³ (approx. 900 × 590 × 1050 mm), black matte background, illuminance ≤20 lux |
| Exhaust Port Diameter | Ø100 mm |
| Touchscreen Interface | 7-inch color HMI with PLC control, on-screen real-time monitoring of voltage, current, droplet count, chamber status, and pass/fail logic |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Type | Electronic CTI/PTI Tester |
| Model | NLD-BI5 |
| Voltage Range | 100–600 V AC (48–60 Hz), 25 V increments |
| Electrode Material | 99% pure platinum (tips), copper (electrode rods) |
| Electrode Dimensions | (2.0 ± 0.1) mm × (5.0 ± 0.1) mm × (40 ± 5) mm |
| Pt tip | 12 mm long, 30° ± 2° bevel |
| Electrode Spacing | 4.00 ± 0.01 mm, 60° ± 5° included angle |
| Electrode Force | 1.00 ± 0.01 N |
| Test Solution Resistivity | Solution A: 3.95 ± 0.05 Ω·m (0.1% NH₄Cl) |
| Solution B | 1.98 ± 0.05 Ω·m |
| Droplet Height | 35 ± 5 mm (adjustable) |
| Droplet Interval | 30.00 ± 0.01 s (digital preset, 50-droplet time: 24.5 ± 2 min) |
| Droplet Count Range | 1–9999 (digital display & preset) |
| Airflow Velocity | 0.2 m/s (per IEC 60695-11-5) |
| Current Trip Threshold | 0.50 A ± 10%, sustained for 2.00 ± 0.2 s |
| Short-Circuit Current Stability | ≤10% voltage drop at 1.0 ± 0.0001 A |
| Power Supply | 220 V, 0.6 kVA, 50–60 Hz |
| Ambient Conditions | 0–40 °C, RH ≤80%, non-corrosive, low-vibration environment |
| Combustion Chamber Volume | >0.5 m³ (approx. 900 × 590 × 1050 mm), black matte background, illuminance ≤20 lux |
| Exhaust Port Diameter | Ø100 mm |
| Touchscreen | 7-inch color HMI with PLC-based control architecture |
| Compliance | GB/T 4207–2003, IEC 60695-11-5, IEC 60695-11-10 |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Type | Electronic Universal Testing Machine |
| Model | NLD-BI6 |
| Voltage Range | 100–600 V AC (48–60 Hz) |
| Electrode Material | 99% Pure Platinum (tips), Copper (electrode rods) |
| Electrode Dimensions | (2.0 ± 0.1) mm × (5.0 ± 0.1) mm × (40 ± 5) mm |
| Electrode Tip Geometry | 12 mm length, 30° ± 2° bevel |
| Electrode Spacing | 4.00 ± 0.01 mm, included angle 60° ± 5° |
| Electrode Force | 1.00 ± 0.01 N |
| Test Solution Resistivity | Solution A: 3.95 ± 0.05 Ω·m (0.1% NH₄Cl) |
| Solution B | 1.98 ± 0.05 Ω·m |
| Droplet Height | 35 ± 5 mm (adjustable) |
| Droplet Interval | 30.00 ± 0.01 s (digital presettable) |
| 50-droplet duration | 24.5 ± 2 min |
| Droplet Count Range | 1–9999 (digital display & preset) |
| Airflow Velocity | 0.2 m/s (per IEC 60695-11-5) |
| Short-Circuit Current Threshold | 0.50 A ± 10%, sustained for 2.00 ± 0.2 s |
| Voltage Drop Limit | ≤8% at 1.0 A ± 0.1 A |
| Power Supply | 220 V, 0.6 kVA, 50–60 Hz |
| Test Chamber Volume | >0.5 m³ (L×W×H ≈ 900 × 590 × 1050 mm) |
| Operating Environment | 0–40 °C, RH ≤80%, non-corrosive, low-vibration |
| Compliance | GB/T 4207–2003, IEC 60695-11-5, IEC 60695-11-10 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NLD-C4 |
| Instrument Type | Electronic Universal Testing Machine |
| Input Voltage | AC 220 V |
| Output Voltage Range | AC 0–5 kV |
| Power Rating | 5 kVA |
| Voltage Accuracy | < 2% |
| High-Side Output Current | > 1 A |
| Current Measurement Accuracy | < 1% |
| Spray Velocity at Specimen | 3 m/s |
| Spray Rate | 0.5 mm/min |
| Standard Spray Cycle | 10 s spray / 20 s pause |
| Nozzle-to-Specimen Distance | ≥ 500 mm |
| Nozzle Angle Relative to Specimen Axis | 45° |
| Spray Range | > 1 m |
| Specimen Length | ≥ 150 mm |
| Compliance | GB/T 3048.7–2007 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMPL-2000A1 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Maximum Load Capacity | 1000 N |
| Reciprocating Compression Frequency | 10–100 cycles/min (Standard Compliance: 70 ± 5 cycles/min per ISO 3385) |
| Max. Cycles | >100,000 |
| Platen Diameter | φ250 mm ± 1 mm, Bottom Edge Radius: R25 mm ± 1 mm |
| Specimen Support Table | 500 mm × 500 mm square, 10 mm thick, with 6.35 mm diameter holes on 20 mm centers |
| Specimen Dimensions | 500 mm × 500 mm × (50 ± 2) mm |
| Force Display | Real-time peak load readout |
| Control Interface | 7-inch color touchscreen HMI |
| Actuation | Servo motor-driven |
| Test Modes | Constant-force loading or constant-thickness compression (expressed as % deformation) |
| End-of-Test Action | Audible alarm + automatic platen return to zero position |
| Specimen Positioning | Adjustable mechanical alignment fixtures ensuring positional stability over extended cycling |
| Power Supply | 220 V AC / 50 Hz |
| Footprint | 800 mm (L) × 500 mm (W) × 1200 mm (H) |
| Net Weight | 100 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMPL2000A2 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Category | Specialized Fatigue Testing Machine |
| Maximum Test Force | 0–2000 N |
| Frequency Range | 0–100 cycles/min (Standard Compliance: 70 ± 5 cycles/min) |
| Unit Weight | 100 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | YHT-RC100a |
| Instrument Type | Electromechanical Universal Testing System |
| Compliance | AS4373D, GJB773A, ASD-STAN PREN6059-502 |
| Control System | Siemens S7-1200 PLC + MCGS 10-inch Capacitive Touch HMI |
| Input Power | AC 220 V ±10%, 50 Hz, 2 kW |
| Test Voltage Range | Adjustable up to 10 kV (per standard requirements) |
| Current Measurement Accuracy | ±1% of reading, resolution 0.01 A |
| Voltage Measurement Accuracy | ±1% of reading, resolution 0.1 V |
| Arc Exposure Duration | 1–99,999,999 s (programmable) |
| Droplet Delivery Rate | 100 ±10 mg/min (8–10 drops/min) via Lead Fluid BV-100 peristaltic pump |
| Blade Stroke Adjustment | 1–10 cm (standard 3.81 ±0.3 cm), bidirectional, servo-driven |
| Blade Reciprocating Speed | 0.5 ±0.05 cycles per second |
| Applied Load on Blade | 250 ±25 g |
| Environmental Operating Range | –30 to +40 °C, ≤85% RH, 80–120 kPa, ≤1000 m altitude |
| Grounding Resistance | <1 Ω |
| Dimensions (L×W×H) | 1400 × 830 × 1500 mm |
| Weight | 300 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | YHT-RC100c |
| Instrument Type | Electromechanical Universal Testing Machine |
| Price | USD 2,250 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YHT-RC100d |
| Instrument Type | Electromechanical Universal Testing Machine |
| Compliance Standards | AS4373D, GJB773A, ASD-STAN PRF-6059-502, EN 6059-502 |
| Power Input | AC 220 V ±10%, 50 Hz ±0.5 Hz, 2 kW |
| Test Modes | Dry & Wet Arc Resistance |
| Arc Current | 1.0 A ±0.2 A |
| Voltage Accuracy | ±1% (0.1 V resolution) |
| Current Accuracy | ±1% (0.01 A resolution) |
| Timing Range | 1–99,999,999 s (programmable) |
| Electrode Travel Stroke | 1–10 cm (standard: 3.81 ±0.3 cm) |
| Electrode Speed | 0.5 ±0.05 cycles per second (full reciprocation) |
| Load Mass on Electrode | 250 ±25 g |
| Dropping Rate | 100 ±10 mg/min (8–10 drops/min, via Lead Fluid BV-100 peristaltic pump) |
| Control System | Siemens S7-1200 PLC (original imported) |
| HMI | Moxa 10-inch capacitive HD touchscreen |
| Safety Protection | Five 7.5 A circuit breakers |
| Grounding Resistance | <1 Ω |
| Ambient Operating Conditions | Altitude ≤1000 m |
| Dimensions (L×W×H) | 1400 × 830 × 1500 mm |
| Weight | 300 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YSRB-300.2 |
| Instrument Type | Electromechanical |
| Maximum Test Load | 100 kN |
| Max Plunger Stroke | 180 mm |
| External Dimensions | 350 mm × 400 mm × 400 mm |
| Net Weight | 70 kg |
| Heating Method | Air Bath |
| Test Channels | 3 |
| Temperature Range | Ambient to 300 °C |
| Temperature Stability | ±2 °C |
| Heating Rate Options | 50 ± 3 °C/h or 10 ± 2 °C/12 min |
| Temperature Resolution | 0.1 °C |
| Deformation Measurement Accuracy | ±0.002 mm |
| Specimen Dimensions | 50 mm × 50 mm × 50 mm or 40 mm × 40 mm × 20 mm |
| Compression Platen Size | 50 mm × 50 mm (×3) |
| Recommended Load Range | 0–1 MPa |
| Heating Chamber Volume | 350 mm × 400 mm × 400 mm |
| Lever Load Amplification Ratio | 1:32 |
| Loading Configuration | Compression (lever-weighted), Flexural (direct-weighted) |
| Standard Compliance | GB/T 20672–2006, DIN 53424 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YSRB-300.3 |
| Instrument Type | Electromechanical |
| Max Test Load | 10 kN |
| Max Plunger Stroke | 180 mm |
| Dimensions (W×D×H) | 580 × 620 × 350 mm |
| Net Weight | 100 kg |
| Heating Method | Air-bath |
| Test Channels | 3 |
| Temperature Range | Ambient to 300 °C |
| Temp. Stability | ±2 °C |
| Heating Rate | 50 ± 3 °C/h or 10 ± 2 °C/12 min |
| Temp. Resolution | 0.1 °C |
| Deformation Resolution | 0.002 mm |
| Specimen Size | 50 × 50 × 50 mm or 40 × 40 × 20 mm |
| Loading Plate | Three 50 × 50 mm square platens |
| Recommended Stress Range | 0–1 MPa |
| Heating Chamber Volume | 350 × 400 × 400 mm |
| Lever Ratio | 1:32 |
| Loading Modes | Compression (lever-weighted), Bending (direct-weighted) |
| Standard Compliance | GB/T 20672–2006, DIN 53424 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YSRB-300B |
| Instrument Type | Electromechanical |
| Maximum Test Load | 100 N |
| Max Plunger Stroke | 180 mm |
| Overall Dimensions (L×W×H) | 1850 × 1580 × 1230 mm |
| Net Weight | 50 kg |
| Heating Method | Air-bath |
| Temperature Range | Ambient to 300 °C |
| Temperature Stability | ±2 °C |
| Heating Rate Options | 50 ±3 °C/h or 10 ±2 °C/12 min |
| Temperature Resolution | 0.1 °C |
| Deformation Measurement Accuracy | ±0.002 mm |
| Specimen Dimensions | 50 × 50 × 50 mm or 40 × 40 × 20 mm |
| Compression Platen Size | 50 × 50 mm (triple station) |
| Recommended Stress Range | 0–1 MPa |
| Heating Chamber Volume | 350 × 400 × 400 mm |
| Lever Load Amplification Ratio | 1:32 |
| Test Modes | Compression (lever-weight loading), Bending (direct-weight loading) |
| Standard Compliance | GB/T 20672–2006, DIN 53424 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | ZKDC-01 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Compliance Standards | MT/T 1051–2007, UL 1642–2005, UL 2054–2005, SJ/T 11169–1998, YD 1268–2003, SJ/T 11170–1998, GB/T 8897.4–2002 |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Model | MCTH-500 |
| Maximum Friction Force Range | 30–150 N (via calibrated deadweight loading) |
| Operating Ambient Temperature | −30 to +40 °C |
| Relative Humidity | ≤85 % RH |
| Atmospheric Pressure | 80–120 kPa |
| Supply Voltage | 220 ±10 % VAC, 50 ±0.5 Hz |
| Total Power Consumption | 20 kW |
| Rotating Disc Diameter | 420 mm |
| Disc Rotational Speed | 2600 rpm |
| Vertical Stroke of Carbon Slider | 100 mm |
| Stroke Frequency | 90 cycles/min |
| Electrical Test Input | 5 V / 500 A AC (adjustable via servo-controlled variac and high-current generator, 3 kVA capacity) |
| Radial Runout Measurement | Integrated dial indicator (0–360° indexed turntable) |
| Data Acquisition | Real-time voltage, current, and rotational speed logging with Excel export |
| Dust Extraction | 3 kW industrial vacuum system |
| Dimensions (L×W×H) | 1500 × 1000 × 1700 mm |
| Weight | 600 kg |
