| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model Series | 1625, 1628, 1631 |
| Viscometer Type | Suspension-level (Ubbelohde-type) capillary viscometer |
| Portability | Portable |
| Operating Environment | Ambient temperature |
| Kinematic Viscosity Range | 0.6 – 100,000 mm²/s (cSt) |
| Calibration Compliance | ISO/IEC 17025-accredited |
| Sample Requirement | Transparent Newtonian or near-Newtonian liquids |
| Fill Volume | 4–40 mL |
| Total Length | 250–330 mm |
| Capillary Stand Compatibility | BS/IP/SL and BS/IP/MSL standards (A1/A2 series adapters) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model Numbers | 51610, 50903 |
| Instrument Type | Capillary Viscometer (Ostwald-type) |
| Portability | Portable |
| Operating Environment | Ambient Temperature |
| Kinematic Viscosity Range | 0.4 – 800 mm²/s |
| Calibration | Pre-calibrated with certified capillary constants (K-values) |
| Fill Volume | 2–3 mL |
| Total Length | 220–290 mm |
| Compliance | Designed for ASTM D445, ISO 3104, and IP 71 standard test methods |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | PREMIUM |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–320,000,000 mPa·s |
| Temperature Range | −40 to +300 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Speed Range | 0.01–250 rpm (2600 selectable speeds) |
| Viscosity Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Compliance Standards | ASTM D1076, D1084, D1286, D1417, D1439, D1638, D1824, D2196, D2336, D2364, D2393, D2556, D2669, D2849, D2983, D2994, D3232, D3236, D3716 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | PULP |
| Instrument Type | Benchtop Fixed-Position Viscometer |
| Operating Environment | Ambient Temperature |
| Compliance Standards | ISO 5351:2004, SCAN-CM 15:99, ASTM D1795, ASTM D4243, TAPPI T230 om-94, PAPTAC G.2423P |
| Measurement Resolution | 0.001 s |
| Sample Capacity | 70 × 40 mL Bottles |
| Solvent Resistance | Phenol, Acetic Acid, Cyclohexane, Acetone |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | RPV-1 |
| Instrument Type | Benchtop Fixed-Position System |
| Operating Environment | Ambient Temperature |
| Compliance | ASTM D445, D789, D1243, D4603 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | RUV-2 |
| Instrument Type | Benchtop Fixed-Position Viscometer |
| Application Environment | Ambient Laboratory Conditions |
| Kinematic Viscosity Range | 1 – 1000 mm²/s (cSt) |
| Temperature Range | 40 – 100 °C |
| Temperature Stability | ±0.01 °C |
| Capillary Type | ASTM Ubbelohde Viscometers (ISO 17025-calibrated) |
| Measurement Positions | 2 |
| Solvent Cleaning & Vacuum Drying | Integrated |
| Power Supply | 100–240 VAC, Max 600 W |
| Dimensions (W × L × H) | 395 × 590 × 580 mm |
| Weight | 75 kg |
| Interfaces | RS232, USB, VGA |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SCAN Viscometer |
| Instrument Type | Portable Capillary Viscometer |
| Compliance | ISO 5351 (Pulp Viscosity) |
| Operating Environment | Ambient Temperature |
| Application | Manual Viscosity Measurement of Cellulosic Pulps |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Product Type | Capillary Viscometer |
| Instrument Category | Kinematic & Dynamic Viscosity Measurement |
| Compliance | UKAS-accredited calibration, ISO/IEC 17025, ASTM D446, ASTM D2171, ISO 3105, IP 71 Part 2, BS 188, EN 12596 |
| Models | 1638 (Shell Reverse Flow), 1647 (Cannon-Ubbelohde), 1659 (Cannon-Manning Semi-Micro), 1677 (Asphalt Institute Vacuum), 1678 (Modified Koppers Vacuum), 1676 (Cannon-Manning Vacuum) |
| Kinematic Viscosity Range | 0.0036–300,000 mm²/s |
| Dynamic Viscosity Range | 4.2–580,000 Pa·s |
| Operating Environment | Ambient temperature (20–25 °C), laboratory benchtop use |
| Calibration | Individually UKAS-certified with traceable K-value (mm²/s)²/s and documented uncertainty budgets |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Smart |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Speed Range | 0.3–100 rpm |
| Speed Steps | 18 |
| Viscosity Accuracy | ±1% of full scale |
| Repeatability | ±2% of full scale |
| Display Resolution | 0.01–1 cP |
| Compliance | ASTM D2196, ISO 2555, ISO 3219, USP <911> |
| Data Interface | USB-B |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Key | Brand: ChemTron |
|---|---|
| Origin | Germany |
| Instrument Type | Capillary Viscometer (Ubbelohde-type) |
| Portability | Benchtop / Modular Integration |
| Operating Temperature Range | –40 °C to +150 °C (model-dependent) |
| Kinematic Viscosity Range | 0.5–30,000 mm²/s (cSt) |
| Compliance | DIN 51562-1, ISO 3105 (BS-IP-SL), ASTM D445 |
| Calibration | Factory-calibrated with certified K-values |
| Capillary Dimensions | Bore diameters from 0.47 mm to 5.35 mm |
| Total Length | ~355 mm |
| Detector Option | Integrated thermal conductivity detector (for opaque & wall-adhering samples) |
| Compatibility | AVS 24 / AVS 26 / AVS 270 automated filling & cleaning systems |
| Material | Borosilicate glass (DIN/ISO-compliant), precision-ground glass threads |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Instrument Type | Capillary Viscometer (U-Tube, Reverse-Flow & Standard) |
| Calibration | ISO/IEC 17025-accredited |
| Viscosity Range | 0.2 – 300,000 mm²/s |
| Fill Volume | 4 – 40 mL |
| Tube Length | 250 – 300 mm |
| Portability | Benchtop / Manual Operation |
| Compliance | ASTM D445, ISO 3104, IP 71, BS EN ISO 3104, USP <911> |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | 1643 / 1671 / 1690 |
| Viscometer Type | Capillary (Ubbelohde) |
| Portability | Portable |
| Operating Environment | Ambient Temperature |
| Kinematic Viscosity Range | 0.3 – 100,000 mm²/s |
| Calibration Standard | ISO/IEC 17025 |
| Accreditation | UKAS (for 1690 series) |
| Capillary Constant (K) | 0.001 – 100 mm²/s² |
| Fill Volume | 18 mL |
| Total Length | 283 mm (1643), 580 mm (1690) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Type | Capillary Viscometer |
| Design | Ubbelohde (Dilution-Compensated) |
| Compliance | DIN 51562-1, ISO 3105, ASTM D2515, ASTM D446 |
| Calibration | NIST-traceable K-value certified (4 significant figures, optional) |
| Capillary Diameter Range | 0.24–6.30 mm |
| Kinematic Viscosity Range | 0.35 to >100,000 mm²/s |
| Fill Volume | 15–22 mL |
| Total Length | 285–290 mm |
| Material | Borosilicate Glass 3.3 (DURAN®) |
| Application | Transparent Newtonian & near-Newtonian Liquids |
| Mounting | Threaded Stem with Integrated Cleaning Tube (Models 541xx & 545xx) |
| Configuration | Manual or Automated Compatibility |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | 1663 |
| Instrument Type | Portable Capillary Viscometer |
| Viscosity Range | 0.6 – 100,000 mm²/s |
| Calibration Compliance | ISO/IEC 17025 |
| Fill Volume | 3 mL |
| Total Length | 295 mm |
| Capillary Constant (K-value) Range | 0.003 – 100.0 mm²/s² |
| Available K-value Codes | 1663/01 to 1663/10 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | V92101 |
| Instrument Type | Portable Falling-Ball Viscometer |
| Viscosity Range | 0.6–75,000 mPa·s |
| Temperature Range | −20 to +120 °C |
| Temperature Resolution | 0.1 °C |
| Measuring Tube Internal Diameter | 15.95 mm |
| Compliance | DIN 53015, ISO 12058 |
| Display | LED with digital temperature readout |
| Thermal Control | External jacketed bath (10 mm OD inlet/outlet ports) |
| Standard Accessories | Calibrated ball set (V92101–V92106), tweezers, cleaning brush, factory calibration certificate |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VACS-EN12596 |
| Instrument Type | Fixed Rotational Viscometer (Capillary Vacuum Method) |
| Compliance | ASTM D2171, EN 12596 |
| Operating Environment | Ambient Temperature |
| Vacuum Control | Digital Vacuum Controller with Membrane Pump |
| Temperature Stability | ±0.1 °C (when used with TCB-7 bath) |
| Sample Measurement Principle | Capillary Efflux Time under Controlled Vacuum |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VICSO 380 |
| Instrument Type | Rotational Viscometer-Based Capillary Viscometry System |
| Viscosity Range | 5–100 mPa·s |
| Temperature Stability | ±0.01 °C |
| Efflux Time Resolution | 0.001 s |
| Mass Accuracy | 0.01 mg or 0.1 mg |
| Compliance | ASTM D445, D789, D1243, D4603 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VISCO 070 |
| Instrument Type | Fixed-Position Capillary Viscometer System |
| Operating Environment | Ambient Temperature |
| Compliance | ASTM D445, ISO 3104, IP 71, GB/T 265 |
| Standard Accessories | Ubbelohde-type glass capillary viscometer, thermostatically controlled viscosity bath (±0.01 °C stability), viscometer stand, calibrated thermometer (±0.02 °C), digital stopwatch (resolution ≥0.1 s |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VISCO 170 |
| Instrument Type | Benchtop Fixed-Position Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Measurement Range | 0.35–10,000 mm²/s (cSt) |
| Time Measurement Range | ≤999.99 s |
| Time Resolution | 0.01 s |
| Time Accuracy | ±0.01 s or ±1 digit (max. uncertainty: 0.1%) |
| Display | LCD, 128×64 pixels, 51×31 mm (w×h) |
| Dimensions (H×W×D) | 515×90×30 mm |
| Weight | 450 g (unit only, no capillary) |
| Compatible Viscometers | Ubbelohde (SIA/DIN/ISO/ASTM), Micro-Ostwald (SIA) |
| Compatible Bath Systems | JULABO DD-16G, DD-31A, DD-18V viscosity baths |
| Data Interface | USB Host (U-disk, printer TZ 3863), USB OTG (PC, printer TZ 3863) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VISCO 270 |
| Instrument Type | Falling-Ball Viscometer |
| Viscosity Range | 5–1200 mPa·s |
| Kinematic Viscosity Range | 0.35–1800 mm²/s (cSt) under pressure mode |
| Pressure/Vacuum Control | ±160 mbar |
| Time Measurement Resolution | 0.01 s |
| Time Accuracy | ±0.01% |
| Sensor Options | Photoelectric or Pt100 thermal resistance sensor |
| Compatible Capillary Types | Ubbelohde, Cannon-Fenske, Ostwald, dilution, and micro-capillaries |
| Optional Accessory | VISCO 26 Automated Capillary Cleaning System |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VISCO AVS Pro III |
| Instrument Type | Benchtop Fixed-Position Viscometer |
| Application | Newtonian Fluid Viscosity Measurement |
| Compliance | ASTM D445, D446, D789, D871, D1243, D1601, D2857, D4020, D4603, D1795 |
| Viscosity Range | 0.35–1,200 mm²/s (at ambient temperature) |
| Timing Resolution | 0.01 s (max. 9999.99 s) |
| Timing Accuracy | ±0.01 s ±1 digit (≤0.01% relative error) |
| Temperature Control | Dual-bath, independently programmable (up to 135 °C), with TC and optical detection |
| Sample Capacity | Up to 56 × 20 mL vials or 16 × 100 mL screw-cap bottles per rack |
| Capillary Compatibility | Ubbelohde (DIN/ASTM), micro-Ubbelohde, Ostwald, Cannon-Fenske, TC-Ubbelohde, TC-micro Ubbelohde |
| Automation | XYZ robotic sample handler, valveless micro-dosing, auto-rinse, capacitive meniscus detection, vacuum-controlled flow initiation |
| Brand | Chengmeng |
|---|---|
| Origin | Beijing, China |
| Model | NDJ-5ST |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 10–100,000 mPa·s |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Speed Settings | 6 / 12 / 30 / 60 rpm |
| Standard Spindles | #1–#4 (L-type) |
| Display | 3.5″ IPS color TFT screen |
| Viscosity Readout Resolution | 0.01 mPa·s |
| Measurement Accuracy | ±2% (Newtonian fluids) |
| Repeatability | ±1% (Newtonian fluids) |
| Compliance | Designed for GLP-compliant routine QC workflows |
| Connectivity | USB & RS-232 |
| Power Input | 100–240 VAC, 50–60 Hz |
| Dimensions (W×D×H) | 280 × 260 × 395 mm |
| Net Weight | 5.6 kg |
| Brand | Chengmeng |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-8ST |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 10–2,000,000 mPa·s |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Standard Spindles | #1–#4 (L-type) |
| Display | 3.5″ IPS color TFT LCD |
| Torque Measurement Accuracy | ±2% (Newtonian fluids) |
| Repeatability | ±1% (Newtonian fluids) |
| Data Storage | 50 measurement records |
| Interface | USB + RS232 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (W×D×H) | 280 × 260 × 395 mm |
| Net Weight | ~5.6 kg |
| Brand | Chengyi (scchengyi) |
|---|---|
| Origin | Sichuan, China |
| Instrument Type | Rotational Viscometer |
| Model | NXS-4CP |
| Viscosity Range | 1800–9900 mPa·s |
| Shear Rates | 10, 20, 40, 60, 80, 100 s⁻¹ |
| Accuracy | ≤±3% FS |
| Repeatability | ≤±1% FS |
| Temperature Range | 5–75 °C |
| Brand | CSC |
|---|---|
| Origin | USA |
| Model | Bostwick |
| Construction | Stainless Steel |
| Dimensions (L×W×H) | 14 in × 3.5 in × 5.5 in |
| Sample Volume | 75 mL |
| Timing Interval | Standard 30 s |
| Scale Graduation | 0.5 cm |
| Leveling | Dual adjustable leveling screws + bubble level |
| Gate Mechanism | Spring-loaded instantaneous release gate |
| Compliance | ASTM D1682 (for consistency testing), ISO 11393-2 (food texture reference), USDA/FSIS guideline compatible |
| Application Scope | Semi-solid food products with yield stress behavior |
| Brand | CSC |
|---|---|
| Origin | USA |
| Model | Bostwick Consistometer |
| Instrument Type | Flow-Through Consistometer (Capillary-Free Gravitational Flow Viscometer) |
| Construction | Stainless Steel Body with Electrolytically Polished 2 mm Steel Ramp |
| Sample Volume | 75 mL |
| Dimensions (L×W×H) | 14 in × 3.5 in × 5.5 in |
| Scale Resolution | 0.5 cm graduations |
| Leveling | Dual adjustable leveling screws + bubble level |
| Flow Gate | Spring-loaded instantaneous release gate |
| Compliance | SNT 1036–2002 (China Export Standard for Tomato Paste), ASTM D1824–22 (Standard Test Method for Consistency of Semisolid Materials), ISO 10985:2021 (Foodstuffs — Determination of Flow Behaviour Using Bostwick Consistometer) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CSC |
| Price Range | USD 140–1,400 (FOB) |
| Instrument Type | Efflux Viscometer |
| Viscosity Range | 0.1–1000 Pa·s (equivalent shear-thinning semi-solids, calibrated via standardized efflux time) |
| Brand | Davenport |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PETPlus |
| Pricing | Available Upon Request |
| Brand | Endecotts |
|---|---|
| Origin | United Kingdom |
| Model | Bostwick |
| Instrument Type | Fixed-Geometry Flow Consistometer |
| Sample Volume | 75 mL |
| Dimensions (L×W×H) | 14 in × 3.5 in × 5.5 in |
| Construction | Electropolished 2 mm stainless steel plate |
| Graduation Scale | 0.5 cm increments |
| Leveling | Dual leveling screws + bubble level |
| Flow Gate | Spring-loaded instantaneous release gate |
| Operating Environment | Ambient temperature |
| Compliance | Designed for routine QC per ASTM D1984, ISO 10664, and USP <911> guidelines |
| Application Domain | Food, dairy, sauces, pastes, cosmetics, coatings |
| Brand | eralytics |
|---|---|
| Origin | Austria |
| Model | ERAVISC X |
| Instrument Type | Portable |
| Measurement Principle | Oscillating U-tube (density) + Dynamic Capillary Flow (kinematic viscosity) |
| Viscosity Range | 1–1000 mm²/s |
| Density Range | 0–3 g/cm³ |
| Temperature Range | 15 °C to 100 °C |
| Heating/Cooling Rate | ±20 °C/min |
| Standards Compliance | ASTM D445, D7042, D4052, D5002 |