AMETEK China

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATLAS
OriginUSA
ModelXenotest Alpha+
Lamp Configuration1 × 2200 W air-cooled xenon arc lamp
Exposure Area1320 cm²
Maximum Irradiance180 W/m² (3× solar intensity, 300–400 nm)
Temperature ControlChamber temperature only (up to 70 °C) or dual control (chamber + black standard thermometer, up to 130 °C)
Humidity Range10–95% RH
Humidity SystemUltrasonic humidification
Water Spray SystemIntegrated with 60 L reservoir
Sample RotationMotorized carousel accommodating 11 sample holders
Irradiance & BST MonitoringXENOSENSIV sensor at sample plane (300–400 nm)
User InterfaceColor touchscreen with multilingual support
Data OutputRS-232, Ethernet, SD card
ComplianceASTM G155, ISO 4892-2, ISO 11341, SAE J2527, AATCC TM16, GB/T 16422.2, and other major weathering standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATLAS
OriginUSA
ModelBCX
Temperature RangeExposure Zone up to 55 °C (131 °F), High-Temp Option up to 71 °C (160 °F)
Chamber ConstructionFiberglass-Reinforced Polymer (FRP) with Gel-Coated Exposure Zone
Solution Reservoir Capacity35 US gal (132 L)
Spray SystemFull-Fog Dispersion Tower or Full-Fog Dispersion II System
HumidificationHeated Air-Pressurized Fog Tower with Automatic Fill
HeatingTitanium Rod Heaters in Exposure Zone
DrainageFront & Rear Wet-Bottom Drain Assemblies
Optional FeaturesPneumatic Lid Assist (BCX9000/BCX11000), Transparent Polypropylene Lid (BCX9000), Ridge-Style Condensate-Resistant Lid Design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATLAS
OriginUSA
ModelXenotest 220 / Xenotest 220+
LampOne 2200 W air-cooled xenon arc lamp
Exposure Area2310 cm²
Irradiance Control Range300–400 nm
Black Standard Temperature ControlUp to 100 °C (dual-control mode)
Chamber Temperature ControlUp to 65 °C (single-mode) or synchronized with black standard (dual-mode)
Relative Humidity Range (Illuminated Phase)20–85 % RH
Humidity SystemUltrasonic humidification with 60 L integrated reservoir and auto-refill
Sample Capacity38 standard textile specimens (19 dual-position sample holders)
ComplianceISO 105-B02, AATCC TM16-2004 Option 3, Marks & Spencer C9/C9A
User InterfaceMonochrome keypad panel (Xenotest 220) or color touchscreen with multilingual UI (Xenotest 220+)
Data StorageInternal flash memory
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATLAS
OriginUSA
ModelSUNTEST XLS+
Xenon Lamp Power1700 W
Irradiance Range30–65 W/m² (300–400 nm)
Black Standard Temperature (BST) Range45–100 °C
Exposure Area1170 cm²
Dimensions (W×D×H)90 × 54 × 62 cm
ComplianceISO 4892-1, CIE 85
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATLAS
OriginUSA
ModelSUNTEST XXL+ FD
Xenon Lamp Power1700 W
Irradiance Range30–65 W/m² (300–400 nm)
Exposure Area3000 cm²
Dimensions (W×D×H)90 × 91 × 172 cm
Black Standard Temperature (BST) Control Range25–100 °C
Chamber Temperature (CHT) Range15–70 °C (with SunCool cooling system enabled/disabled)
Humidity ControlUltrasonic humidification system (optional with SunCool deactivation)
Spray SystemIntegrated 60 L tank, 25–70 °C operation
Sample Plane Tilt
Irradiance & Temperature ToleranceUser-definable setpoint tolerances for all critical parameters
ComplianceISO 4892-1, CIE 85:2015
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAND
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelVIRALERT 3
PriceUpon Request
Spectral Response7.5–13.5 µm (typical uncooled microbolometer range)
Detector TypeUncooled VOx Microbolometer
Measurement PrincipleNon-contact infrared radiometry
Operating ModeAmbient-temperature-stabilized thermal imaging
Frame Rate<9 Hz
Temperature Accuracy±0.5 °C at 1 m distance (±0.9 °F)
Temperature Range10 °C to 50 °C (ambient operating), 30 °C to 45 °C (human skin temperature measurement range)
Thermal Resolution (NETD)<0.12 °C
IR Image Resolution1280 × 960 pixels
Visual Camera Resolution1280 × 960 @ 12 fps (CMOS color sensor)
Field of View39° × 31°
Reference SourceIntegrated fixed-point blackbody at 38.0 °C ± 0.2 °C
Power Supply5 V DC via USB (blackbody), system powered via PC USB or external 12 V DC adapter
ComplianceCE, UKCA, RoHS, ISO/IEC 17025 traceable calibration support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAGNETROL
ModelEclipse® 706 Series
Measurement PrincipleTime-Domain Reflectometry (TDR)
Power Supply24 VDC loop-powered
Output SignalHART® or Foundation Fieldbus™ or Modbus RTU
Explosion ProtectionIntrinsically Safe (IS), Flameproof (Ex d), Non-incendive (NI) certified
Process Pressure RangeFull vacuum to 43 MPa (6250 psi)
Process Temperature Range–196 °C to +450 °C (–320 °F to +850 °F)
SIL RatingSIL 2/3 compliant (SFF = 93%
Diagnostic CapabilityAdvanced self-diagnostics with echo curve visualization
Probe TypesRigid rod, flexible cable, coaxial, and dual-rod configurations
Display OptionIntegrated LCD with real-time echo profile
ComplianceIEC 61508, IEC 61511, ATEX, IECEx, CSA, FM, NEMA 4X/IP66
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPROCESS INSTRUMENTS
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelChanscope II
Product TypePortable Dew Point Meter
Measurement PrincipleChilled-Mirror Hygrometry
Operating Temperature Range–20 °C to +40 °C
Accuracy±0.2 °C
Repeatability±0.1 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ManufacturerSpectro Scientific
TypeImported
ModelSpectrOil M/N-W
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAGNETROL
ModelThermatel® TA2 Series
Measurement PrincipleThermal Dispersion (Constant Temperature Anemometry)
Output Options4–20 mA analog + HART® v7.5 or Foundation Fieldbus™
Display2-line × 16-character LCD
Accuracy±1% of reading (typical, dependent on gas composition and calibration conditions)
Repeatability±0.5% of reading
Turndown RatioUp to 100:1
Operating Temperature Range–40 °C to +85 °C (electronics)
Pressure RatingUp to 10 MPa (depending on process connection)
Probe Materials316 SS standard
CertificationsATEX, IECEx, UL/cUL Class I Div 1, SIL 2 per IEC 61508
Enclosure RatingIP66/NEMA 4X
Process ConnectionsNPT, SAE, DIN, ANSI flanges (varies by model)
Probe LengthStandard 150 mm to 1200 mm (custom lengths available)
InstallationIn-line or insertion type
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATLAS
OriginUSA
ModelSUNTEST CPS+
Xenon Lamp Power1500 W
Irradiance Range30–65 W/m² (300–400 nm)
Black Standard Temperature (BST) Range35–100 °C (without SunCool)
Exposure Area560 cm²
Dimensions (W×D×H)90 × 35 × 35 cm
CoolingAir-cooled lamp
Control InterfaceMicroprocessor-based with programmable keypad and monochrome display
ComplianceISO 4892-1, CIE Publication No. 85
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATLAS
OriginUSA
ModelCCX
Temperature RangeUp to 71°C (standard), optional up to 90°C
Chamber Capacities565 L (CCX2000) to 3115 L (CCX11000)
ComplianceSAE J2334, Ford BI-123-01, Ford APGE, GM9540P, GMW14872, ASTM B117, ISO 9227, DIN 50021
Control SystemPLC-based with programmable multi-step cycling
Humidity GenerationHeated foam tower with pressure-regulated air bleed
Exposure Zone ConstructionFiberglass-reinforced polymer (FRP) with gel-coated interior
Solution Reservoir227 L (60 gal) standard
HeatingTitanium rod heaters in exposure zone
Lid DesignRidge-roof configuration to prevent condensate drip
SealingDual magnetic gasket on transparent lid
Optional FeaturesSO₂ injection, Prohesion™ mode, non-condensing humidity control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATLAS
OriginUSA
ModelUVTest
Test Duration1–9999 h
Irradiance RangeTypical 0.89 W/m² (UVA), 0.71 W/m² (UVB)
Lamp Power40 W per tube
Humidity ControlHigh-humidity mode
Illuminated Chamber Temperature Range35–80 °C
Black Panel Temperature (BPT) RangeUV Phase 35–80 °C
Spectral Peak Wavelengths351 nm, 340 nm, 313 nm (irradiance-controlled)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPrinceton Instruments
OriginUSA
ModelQCM 922
Frequency Range1–10 MHz
Frequency Resolution0.1 Hz
Resonance Resistance Range10–16 kΩ (0.1 Ω resolution)
Electrode Area0.2 cm²
Electrode MaterialSputtered Au or Pt (300 nm thickness)
Crystal Fundamental Frequency9 MHz
Operating Temperature0–40 °C
Power Supply100–120 VAC / 230–240 VAC, 50–60 Hz, 15 W
InterfaceIEEE-488 (GPIB), RS-232
Analog Outputs±10 V (12-bit), selectable impedance scaling (1/2/4/8/16 kΩ)
Display40-character × 2-line LCD
Dimensions26 × 88 × 230 mm
Weight3.3 kg
Software CompatibilityWindows 95/98, ≥100 MHz CPU, 32 MB RAM, 10 MB HDD, GPIB interface card required
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChatillon
OriginUSA
ModelDFS 3
Force Range0.5–500 lbf (2.5–2500 N)
Accuracy±0.1% of full scale
Sampling RateUp to 30 kHz
DisplayFull-color LCD with adjustable brightness and invertible orientation
Unitsozf, gf, lbf, kgf, N
InterfaceUSB, RS-232
SoftwareForceTest 3.0 (included)
ComplianceCE, RoHS
Enclosure RatingIP65-rated front panel
Password ProtectionYes (menu lock, setup lock, result masking)
Built-in StatisticsMin/Max/Avg/Peak/SD/CPK
Audible FeedbackConfigurable key tone & alarm
Environmental RatingOperating temp. 0–40 °C, humidity ≤80% RH non-condensing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLAND
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMillWatch / SiloWatch
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelSpectrOil M
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPROCESS INSTRUMENTS
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelTA7000
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMAGNETROL
ModelPulsar® R80
Measurement PrincipleFrequency-Modulated Continuous Wave (FMCW) Radar
Operating Frequency80 GHz
Beam Angle<3°
Maximum Process Pressure70 bar (1000 psi)
Maximum Process Temperature200 °C (400 °F)
Output Signal4–20 mA HART
Enclosure RatingIP66/IP67, NEMA 4X
Antenna OptionsStainless steel horn antennas with optional PTFE or ceramic coating
DisplayOptional integrated LCD graphic display
CommunicationHART 7, Foundation Fieldbus (optional)
DiagnosticsAdvanced onboard diagnostics with echo curve analysis, false echo suppression, and predictive health monitoring
CertificationsATEX, IECEx, FM, CSA, SIL2 per IEC 61508
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGRABNER
OriginAustria
ModelMINISCAN IR Vision Gasoline
PortabilityPortable
Measurement Range70–110 (RON/MON)
Accuracy±0.5
Analysis Time<80 s
Sample Volume6 mL
ComplianceGB/T 33648–2017, ASTM D5845, ASTM D6277, EN 238, SH/T 0797, ASTM E1655, GB/T 29858
Spectrometer TypeTemperature- and Laser-Stabilized Dual Interferometer with KBr-coated Ge Beamsplitter
Sample CellThermoelectrically Controlled 2+1 Smart Cell Design
Density MeasurementIntegrated TE-Controlled Digital Density Meter (±0.0001 g/cm³)
Data Output Unitsv%, m%
Display10-inch Industrial TFT Touchscreen
Connectivity2× USB, 2× LAN
Power100–264 V AC / 47–63 Hz / 130 W or 12 V DC via Vehicle Adapter
Dimensions293 × 390 × 280 mm
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATLAS
OriginUSA
ModelSF Series
Chamber Capacity420–3680 L
Internal Dimensions (W×D×H)0.76×0.56×0.99 m to 3.05×1.22×0.99 m
External Dimensions (W×D×H)1.07×0.97×1.52 m to 3.81×1.52×1.60 m
Temperature RangeAmbient to 55 °C (standard operation)
Humidity ControlNon-condensing RH 10–98%
Salt Spray Deposition RateCompliant with ASTM B117 (typically 1.0–2.0 mL/80 cm²/h)
ComplianceASTM B117, ASTM D1735, ISO 9227, ASTM G85 Annexes 4 & 5, ISO 6988, GM 4429P, GM 4465P, CASS, SWAAT, ASTM D2247, FLTM BQ4-2, Corrodcote™
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTaylor Hobson
OriginUnited Kingdom
ModelPGI Freeform
Measurement PrincipleContact Stylus Profilometry with Radial & Grating-Scan Modes
Vertical Range28 mm
Vertical Resolution0.8 nm
Tilt Capability±50°
Form Error Accuracy<150 nm PV
Motion ArchitectureFEA-Optimized Ultra-Stiff Mechanical Axes
ComplianceISO 10360, ISO 1101, ISO 16610, ISO 25178 (Part 2, Part 601–607), ASTM E1155, USP <1059>, GLP/GMP-ready audit trail support in software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPrinceton Applied Research
OriginUSA
ModelP3000A
Channel ConfigurationSingle-Channel
Current Range±1 A
Current Accuracy±0.2% of reading
Potential Accuracy±0.2% of reading
Potentiostatic Range±30 V
EIS Frequency Range10 µHz to 10 MHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandORTEC
OriginUSA
ModelDSPEC-50
InterfaceUSB 2.0 & Ethernet (TCP/IP)
DisplayIntegrated large LCD panel
Detector CompatibilityHPGe, Si(Li), NaI(Tl), and other pulse-mode radiation detectors
Dead Time CorrectionAdvanced real-time algorithm
LFR (Low-Frequency Noise Rejection)Enabled
Count Rate CapabilityUp to 30% higher throughput at ultra-high count rates
Resolution EnhancementMitigates EC-induced resolution degradation
Form FactorBenchtop digital multichannel analyzer (MCA)