- All
- Favorite
- Popular
- Most rated
| Brand | ATLAS |
|---|---|
| Origin | USA |
| Model | Xenotest Alpha+ |
| Lamp Configuration | 1 × 2200 W air-cooled xenon arc lamp |
| Exposure Area | 1320 cm² |
| Maximum Irradiance | 180 W/m² (3× solar intensity, 300–400 nm) |
| Temperature Control | Chamber temperature only (up to 70 °C) or dual control (chamber + black standard thermometer, up to 130 °C) |
| Humidity Range | 10–95% RH |
| Humidity System | Ultrasonic humidification |
| Water Spray System | Integrated with 60 L reservoir |
| Sample Rotation | Motorized carousel accommodating 11 sample holders |
| Irradiance & BST Monitoring | XENOSENSIV sensor at sample plane (300–400 nm) |
| User Interface | Color touchscreen with multilingual support |
| Data Output | RS-232, Ethernet, SD card |
| Compliance | ASTM G155, ISO 4892-2, ISO 11341, SAE J2527, AATCC TM16, GB/T 16422.2, and other major weathering standards |
| Brand | ATLAS |
|---|---|
| Origin | USA |
| Model | BCX |
| Temperature Range | Exposure Zone up to 55 °C (131 °F), High-Temp Option up to 71 °C (160 °F) |
| Chamber Construction | Fiberglass-Reinforced Polymer (FRP) with Gel-Coated Exposure Zone |
| Solution Reservoir Capacity | 35 US gal (132 L) |
| Spray System | Full-Fog Dispersion Tower or Full-Fog Dispersion II System |
| Humidification | Heated Air-Pressurized Fog Tower with Automatic Fill |
| Heating | Titanium Rod Heaters in Exposure Zone |
| Drainage | Front & Rear Wet-Bottom Drain Assemblies |
| Optional Features | Pneumatic Lid Assist (BCX9000/BCX11000), Transparent Polypropylene Lid (BCX9000), Ridge-Style Condensate-Resistant Lid Design |
| Brand | ATLAS |
|---|---|
| Origin | USA |
| Model | Xenotest 220 / Xenotest 220+ |
| Lamp | One 2200 W air-cooled xenon arc lamp |
| Exposure Area | 2310 cm² |
| Irradiance Control Range | 300–400 nm |
| Black Standard Temperature Control | Up to 100 °C (dual-control mode) |
| Chamber Temperature Control | Up to 65 °C (single-mode) or synchronized with black standard (dual-mode) |
| Relative Humidity Range (Illuminated Phase) | 20–85 % RH |
| Humidity System | Ultrasonic humidification with 60 L integrated reservoir and auto-refill |
| Sample Capacity | 38 standard textile specimens (19 dual-position sample holders) |
| Compliance | ISO 105-B02, AATCC TM16-2004 Option 3, Marks & Spencer C9/C9A |
| User Interface | Monochrome keypad panel (Xenotest 220) or color touchscreen with multilingual UI (Xenotest 220+) |
| Data Storage | Internal flash memory |
| Brand | ATLAS |
|---|---|
| Origin | USA |
| Model | SUNTEST XLS+ |
| Xenon Lamp Power | 1700 W |
| Irradiance Range | 30–65 W/m² (300–400 nm) |
| Black Standard Temperature (BST) Range | 45–100 °C |
| Exposure Area | 1170 cm² |
| Dimensions (W×D×H) | 90 × 54 × 62 cm |
| Compliance | ISO 4892-1, CIE 85 |
| Brand | ATLAS |
|---|---|
| Origin | USA |
| Model | SUNTEST XXL+ FD |
| Xenon Lamp Power | 1700 W |
| Irradiance Range | 30–65 W/m² (300–400 nm) |
| Exposure Area | 3000 cm² |
| Dimensions (W×D×H) | 90 × 91 × 172 cm |
| Black Standard Temperature (BST) Control Range | 25–100 °C |
| Chamber Temperature (CHT) Range | 15–70 °C (with SunCool cooling system enabled/disabled) |
| Humidity Control | Ultrasonic humidification system (optional with SunCool deactivation) |
| Spray System | Integrated 60 L tank, 25–70 °C operation |
| Sample Plane Tilt | 5° |
| Irradiance & Temperature Tolerance | User-definable setpoint tolerances for all critical parameters |
| Compliance | ISO 4892-1, CIE 85:2015 |
| Brand | LAND |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | VIRALERT 3 |
| Price | Upon Request |
| Spectral Response | 7.5–13.5 µm (typical uncooled microbolometer range) |
| Detector Type | Uncooled VOx Microbolometer |
| Measurement Principle | Non-contact infrared radiometry |
| Operating Mode | Ambient-temperature-stabilized thermal imaging |
| Frame Rate | <9 Hz |
| Temperature Accuracy | ±0.5 °C at 1 m distance (±0.9 °F) |
| Temperature Range | 10 °C to 50 °C (ambient operating), 30 °C to 45 °C (human skin temperature measurement range) |
| Thermal Resolution (NETD) | <0.12 °C |
| IR Image Resolution | 1280 × 960 pixels |
| Visual Camera Resolution | 1280 × 960 @ 12 fps (CMOS color sensor) |
| Field of View | 39° × 31° |
| Reference Source | Integrated fixed-point blackbody at 38.0 °C ± 0.2 °C |
| Power Supply | 5 V DC via USB (blackbody), system powered via PC USB or external 12 V DC adapter |
| Compliance | CE, UKCA, RoHS, ISO/IEC 17025 traceable calibration support |
| Brand | MAGNETROL |
|---|---|
| Model | Eclipse® 706 Series |
| Measurement Principle | Time-Domain Reflectometry (TDR) |
| Power Supply | 24 VDC loop-powered |
| Output Signal | HART® or Foundation Fieldbus™ or Modbus RTU |
| Explosion Protection | Intrinsically Safe (IS), Flameproof (Ex d), Non-incendive (NI) certified |
| Process Pressure Range | Full vacuum to 43 MPa (6250 psi) |
| Process Temperature Range | –196 °C to +450 °C (–320 °F to +850 °F) |
| SIL Rating | SIL 2/3 compliant (SFF = 93% |
| Diagnostic Capability | Advanced self-diagnostics with echo curve visualization |
| Probe Types | Rigid rod, flexible cable, coaxial, and dual-rod configurations |
| Display Option | Integrated LCD with real-time echo profile |
| Compliance | IEC 61508, IEC 61511, ATEX, IECEx, CSA, FM, NEMA 4X/IP66 |
| Brand | PROCESS INSTRUMENTS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Chanscope II |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror Hygrometry |
| Operating Temperature Range | –20 °C to +40 °C |
| Accuracy | ±0.2 °C |
| Repeatability | ±0.1 °C |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Spectro Scientific |
| Type | Imported |
| Model | SpectrOil M/N-W |
| Pricing | Upon Request |
| Brand | MAGNETROL |
|---|---|
| Model | Thermatel® TA2 Series |
| Measurement Principle | Thermal Dispersion (Constant Temperature Anemometry) |
| Output Options | 4–20 mA analog + HART® v7.5 or Foundation Fieldbus™ |
| Display | 2-line × 16-character LCD |
| Accuracy | ±1% of reading (typical, dependent on gas composition and calibration conditions) |
| Repeatability | ±0.5% of reading |
| Turndown Ratio | Up to 100:1 |
| Operating Temperature Range | –40 °C to +85 °C (electronics) |
| Pressure Rating | Up to 10 MPa (depending on process connection) |
| Probe Materials | 316 SS standard |
| Certifications | ATEX, IECEx, UL/cUL Class I Div 1, SIL 2 per IEC 61508 |
| Enclosure Rating | IP66/NEMA 4X |
| Process Connections | NPT, SAE, DIN, ANSI flanges (varies by model) |
| Probe Length | Standard 150 mm to 1200 mm (custom lengths available) |
| Installation | In-line or insertion type |
| Brand | ATLAS |
|---|---|
| Origin | USA |
| Model | SUNTEST CPS+ |
| Xenon Lamp Power | 1500 W |
| Irradiance Range | 30–65 W/m² (300–400 nm) |
| Black Standard Temperature (BST) Range | 35–100 °C (without SunCool) |
| Exposure Area | 560 cm² |
| Dimensions (W×D×H) | 90 × 35 × 35 cm |
| Cooling | Air-cooled lamp |
| Control Interface | Microprocessor-based with programmable keypad and monochrome display |
| Compliance | ISO 4892-1, CIE Publication No. 85 |
| Brand | ATLAS |
|---|---|
| Origin | USA |
| Model | CCX |
| Temperature Range | Up to 71°C (standard), optional up to 90°C |
| Chamber Capacities | 565 L (CCX2000) to 3115 L (CCX11000) |
| Compliance | SAE J2334, Ford BI-123-01, Ford APGE, GM9540P, GMW14872, ASTM B117, ISO 9227, DIN 50021 |
| Control System | PLC-based with programmable multi-step cycling |
| Humidity Generation | Heated foam tower with pressure-regulated air bleed |
| Exposure Zone Construction | Fiberglass-reinforced polymer (FRP) with gel-coated interior |
| Solution Reservoir | 227 L (60 gal) standard |
| Heating | Titanium rod heaters in exposure zone |
| Lid Design | Ridge-roof configuration to prevent condensate drip |
| Sealing | Dual magnetic gasket on transparent lid |
| Optional Features | SO₂ injection, Prohesion™ mode, non-condensing humidity control |
| Brand | ATLAS |
|---|---|
| Origin | USA |
| Model | UVTest |
| Test Duration | 1–9999 h |
| Irradiance Range | Typical 0.89 W/m² (UVA), 0.71 W/m² (UVB) |
| Lamp Power | 40 W per tube |
| Humidity Control | High-humidity mode |
| Illuminated Chamber Temperature Range | 35–80 °C |
| Black Panel Temperature (BPT) Range | UV Phase 35–80 °C |
| Spectral Peak Wavelengths | 351 nm, 340 nm, 313 nm (irradiance-controlled) |
| Brand | Princeton Instruments |
|---|---|
| Origin | USA |
| Model | QCM 922 |
| Frequency Range | 1–10 MHz |
| Frequency Resolution | 0.1 Hz |
| Resonance Resistance Range | 10–16 kΩ (0.1 Ω resolution) |
| Electrode Area | 0.2 cm² |
| Electrode Material | Sputtered Au or Pt (300 nm thickness) |
| Crystal Fundamental Frequency | 9 MHz |
| Operating Temperature | 0–40 °C |
| Power Supply | 100–120 VAC / 230–240 VAC, 50–60 Hz, 15 W |
| Interface | IEEE-488 (GPIB), RS-232 |
| Analog Outputs | ±10 V (12-bit), selectable impedance scaling (1/2/4/8/16 kΩ) |
| Display | 40-character × 2-line LCD |
| Dimensions | 26 × 88 × 230 mm |
| Weight | 3.3 kg |
| Software Compatibility | Windows 95/98, ≥100 MHz CPU, 32 MB RAM, 10 MB HDD, GPIB interface card required |
| Brand | Chatillon |
|---|---|
| Origin | USA |
| Model | DFS 3 |
| Force Range | 0.5–500 lbf (2.5–2500 N) |
| Accuracy | ±0.1% of full scale |
| Sampling Rate | Up to 30 kHz |
| Display | Full-color LCD with adjustable brightness and invertible orientation |
| Units | ozf, gf, lbf, kgf, N |
| Interface | USB, RS-232 |
| Software | ForceTest 3.0 (included) |
| Compliance | CE, RoHS |
| Enclosure Rating | IP65-rated front panel |
| Password Protection | Yes (menu lock, setup lock, result masking) |
| Built-in Statistics | Min/Max/Avg/Peak/SD/CPK |
| Audible Feedback | Configurable key tone & alarm |
| Environmental Rating | Operating temp. 0–40 °C, humidity ≤80% RH non-condensing |
| Brand | LAND |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MillWatch / SiloWatch |
| Pricing | Available Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | SpectrOil M |
| Price | Upon Request |
| Brand | PROCESS INSTRUMENTS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TA7000 |
| Pricing | Available Upon Request |
| Brand | MAGNETROL |
|---|---|
| Model | Pulsar® R80 |
| Measurement Principle | Frequency-Modulated Continuous Wave (FMCW) Radar |
| Operating Frequency | 80 GHz |
| Beam Angle | <3° |
| Maximum Process Pressure | 70 bar (1000 psi) |
| Maximum Process Temperature | 200 °C (400 °F) |
| Output Signal | 4–20 mA HART |
| Enclosure Rating | IP66/IP67, NEMA 4X |
| Antenna Options | Stainless steel horn antennas with optional PTFE or ceramic coating |
| Display | Optional integrated LCD graphic display |
| Communication | HART 7, Foundation Fieldbus (optional) |
| Diagnostics | Advanced onboard diagnostics with echo curve analysis, false echo suppression, and predictive health monitoring |
| Certifications | ATEX, IECEx, FM, CSA, SIL2 per IEC 61508 |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINISCAN IR Vision Gasoline |
| Portability | Portable |
| Measurement Range | 70–110 (RON/MON) |
| Accuracy | ±0.5 |
| Analysis Time | <80 s |
| Sample Volume | 6 mL |
| Compliance | GB/T 33648–2017, ASTM D5845, ASTM D6277, EN 238, SH/T 0797, ASTM E1655, GB/T 29858 |
| Spectrometer Type | Temperature- and Laser-Stabilized Dual Interferometer with KBr-coated Ge Beamsplitter |
| Sample Cell | Thermoelectrically Controlled 2+1 Smart Cell Design |
| Density Measurement | Integrated TE-Controlled Digital Density Meter (±0.0001 g/cm³) |
| Data Output Units | v%, m% |
| Display | 10-inch Industrial TFT Touchscreen |
| Connectivity | 2× USB, 2× LAN |
| Power | 100–264 V AC / 47–63 Hz / 130 W or 12 V DC via Vehicle Adapter |
| Dimensions | 293 × 390 × 280 mm |
| Weight | 12 kg |
| Brand | ATLAS |
|---|---|
| Origin | USA |
| Model | SF Series |
| Chamber Capacity | 420–3680 L |
| Internal Dimensions (W×D×H) | 0.76×0.56×0.99 m to 3.05×1.22×0.99 m |
| External Dimensions (W×D×H) | 1.07×0.97×1.52 m to 3.81×1.52×1.60 m |
| Temperature Range | Ambient to 55 °C (standard operation) |
| Humidity Control | Non-condensing RH 10–98% |
| Salt Spray Deposition Rate | Compliant with ASTM B117 (typically 1.0–2.0 mL/80 cm²/h) |
| Compliance | ASTM B117, ASTM D1735, ISO 9227, ASTM G85 Annexes 4 & 5, ISO 6988, GM 4429P, GM 4465P, CASS, SWAAT, ASTM D2247, FLTM BQ4-2, Corrodcote™ |
| Brand | Taylor Hobson |
|---|---|
| Origin | United Kingdom |
| Model | PGI Freeform |
| Measurement Principle | Contact Stylus Profilometry with Radial & Grating-Scan Modes |
| Vertical Range | 28 mm |
| Vertical Resolution | 0.8 nm |
| Tilt Capability | ±50° |
| Form Error Accuracy | <150 nm PV |
| Motion Architecture | FEA-Optimized Ultra-Stiff Mechanical Axes |
| Compliance | ISO 10360, ISO 1101, ISO 16610, ISO 25178 (Part 2, Part 601–607), ASTM E1155, USP <1059>, GLP/GMP-ready audit trail support in software |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | P3000A |
| Channel Configuration | Single-Channel |
| Current Range | ±1 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz to 10 MHz |
| Brand | ORTEC |
|---|---|
| Origin | USA |
| Model | DSPEC-50 |
| Interface | USB 2.0 & Ethernet (TCP/IP) |
| Display | Integrated large LCD panel |
| Detector Compatibility | HPGe, Si(Li), NaI(Tl), and other pulse-mode radiation detectors |
| Dead Time Correction | Advanced real-time algorithm |
| LFR (Low-Frequency Noise Rejection) | Enabled |
| Count Rate Capability | Up to 30% higher throughput at ultra-high count rates |
| Resolution Enhancement | Mitigates EC-induced resolution degradation |
| Form Factor | Benchtop digital multichannel analyzer (MCA) |
Show next