| Brand | PSI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DL-PSI786 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 2–3 mol |
| Reactor Quantity | 1 |
| Reactor Volume Range | 200 L / 300 L |
| Syringe Pump Accuracy | ±1 mL |
| Synthesis Purity | ≥99.5% |
| Flow Rate | 10–20 L/min |
| Brand | Dilun Bio |
|---|---|
| Origin | Beijing, China |
| Model | 431 |
| Amino Acid Addition | Automated |
| Reagent Addition | Automated |
| Reactor Count | 1 |
| Reactor Volume Range | 10–500 mL |
| Cleavage Volume Precision | ±0.1 mL |
| Precipitation Volume Precision | ±0.1 mL |
| Cleavage Reservoir | 5 L (PP) |
| Precipitation Reservoir | 5 L (Glass) |
| Stirring Method | Magnetic Stirring |
| Power Supply | 110/220 V, 50/60 Hz |
| Dimensions (W×D×H) | 45×45×66 cm |
| Weight | 30 kg |
| Brand | Dilun Bio |
|---|---|
| Origin | Beijing, China |
| Model | 586 Pro |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 8–360 mmol |
| Reactor Count | 2 |
| Reactor Volume Options | 2/10 L or 5/30 L |
| Solvent Reservoir Capacity | 50/100/200 L |
| Stirring Mode | 180° mechanical flip agitation |
| Stirring Speed | 0–30 rpm |
| Temperature Control | Water Bath |
| Amino Acid Positions | 4 |
| Solvent Ports | 5 |
| Wash Ports | 2 |
| Dimensions (W×D×H) | 92 × 85 × 165 cm |
| Weight | 330 kg |
| Power Supply | 110/220 V, 50/60 Hz |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI319 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 0.25–3 mmol per channel |
| Reactor Count | 1 |
| Reactor Volumes | 50 mL, 100 mL, 200 mL (jacketed) |
| Syringe Pump Accuracy | ±0.1 mL |
| Synthesis Purity | ≥99.5% |
| Solvent Flow Rate | 2–4 mL/sec |
| Brand | Dilun Bio |
|---|---|
| Origin | Beijing, China |
| Model | 286 Pro |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 0.05–10 mmol |
| Reactor Count | 3 (expandable to 6) |
| Reactor Volume Options | 25/50 mL, 100/200 mL, 200/500 mL |
| Amino Acid Positions | 24 |
| Activator Solvent Positions | 4 |
| Other Solvent Positions | 4 |
| Solvent Reservoir Capacity | 0.5–10 L |
| Temperature Control | 360° circumferential electromagnetic induction hot-air heating |
| Mixing Mode | 180° bidirectional tumbling + nitrogen sparging |
| Amino Acid Quantitative Transfer | full dissolution & complete transfer |
| Activator Dispensing Accuracy | ±0.1 mL |
| Solvent Dispensing Accuracy | ±1 mL |
| Dimensions (W×D×H) | 90 × 62 × 82 cm |
| Weight | 87 kg |
| Power Supply | 110/220 V, 50/60 Hz |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI386 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 0.25–3 mmol per channel |
| Reactor Count | 30 |
| Reactor Volumes | 50 mL, 100 mL, 200 mL (jacketed) |
| Syringe Pump Accuracy | ±0.01 mL |
| Coupling Efficiency / Crude Purity | ≥99.5% |
| Solvent Flow Rate | 2–4 mL/s |
| Mixing Mechanism | Stirring-free reactor inversion (180° mechanical oscillation) |
| Inversion Speed | 0–30 rpm, continuously adjustable |
| Solvent Reservoirs | 8 units |
| Power Supply | 110/220 V, 50/60 Hz |
| Enclosure Material | 304 stainless steel |
| Unit Weight | 100–150 kg |
| Dimensions (W×D×H) | 113 × 58 × 72 cm |
| Brand | Dilun Bio |
|---|---|
| Origin | Beijing, China |
| Model | 386MW |
| Amino Acid Addition | Automated |
| Reagent Addition | Automated |
| Synthesis Scale | 0.1–1.5 mmol |
| Reactor Count | 1 |
| Reactor Volume Options | 30 mL / 120 mL |
| Synthesis Purity | ≥99.5% |
| Amino Acid Positions | 28 |
| Activator Positions | 4 |
| Solvent Positions | 4–6 |
| Dimensions (W×D×H) | 77.5 × 55 × 84 cm |
| Weight | 75 kg |
| Power Supply | 110/220 V, 50/60 Hz |
| Brand | Dilun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DL-PC |
| Quotation | Upon Request |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 1.8–3.6 mol |
| Reactor Count | 1 |
| Reactor Volume Range | 20–250 L |
| Cleavage Vessel Capacity | 20–250 L |
| Solvent Positioning Sites | ≤5 |
| Concentration Vessel | 1 unit |
| Precipitation Vessel | 1 unit |
| Cleavage Temperature Control Range | −20 to +50 °C |
| Vessel Material | 316L Stainless Steel with Hastelloy lining or PTFE-E coating |
| Agitation Mode | Mechanical Stirring |
| Power Supply | 220/380 V AC |
| Explosion Protection Rating | Exia IIC T4 GB |
| Brand | PSI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Dilun-PC |
| Pricing | Available Upon Request |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI314 |
| Synthesis Scale | 2.5–20 mmol per channel |
| Reactor Count | 3 or 6 |
| Reactor Volume Options | 0.5 L / 1 L / 2 L |
| Syringe Pump Accuracy | ±0.1 mL |
| Synthesis Purity | ≥99.5% |
| Solvent Flow Rate | 200 mL/min |
| Mixing Mode | Dual-axis reactor inversion (stirrer-free) |
| Power Supply | 110/220 V, 50/60 Hz |
| Construction Material | 304 stainless steel frame, borosilicate glass solvent reservoirs (0.5–5 L), 316L stainless steel large-capacity tanks (10–30 L) |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI686 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 0.15–1 mmol and 1–3 mmol |
| Reactor Quantity | 1 |
| Reactor Volume Options | 30 L / 50 L / 100 L / 200 L |
| Syringe Pump Precision | ±1 mL |
| Synthesis Purity | ≥99.5% |
| Solvent Flow Rate | 10–20 L/min |
| Construction Material | 304 Stainless Steel |
| Reactor Drive Power | 1.8–3.5 kW |
| Reactor Dimensions (L×W×H) | 158–185 cm × 70–95 cm × 125–165 cm |
| Cabinet Dimensions (L×W×H) | 145–165 cm × 90–120 cm × 185–215 cm |
| Mixing Mechanism | 180° bidirectional reactor inversion (impeller-free) |
| Solvent Inlet Channels | 3 or 5 (tubing-based) |
| Waste Discharge Ports | 3 (categorized, tubing-based) |
| Recycle Loops | 2 (tubing-based) |
| Stirring Speed Range | 0–15 rpm (infinitely variable) |
| Brand | Dilun Bio |
|---|---|
| Origin | Beijing, China |
| Model | 319 Pro |
| Channel Count | 1 |
| Reactor Quantity | 2 |
| Reactor Volume Range | 25/50 mL and 50/100/250 mL |
| Synthesis Scale | 0.1–3 mmol |
| Amino Acid Positions | 8 or 16 |
| Solvent Ports | 7 |
| Solvent Reservoir Options | 0.5 L, 1 L, 2 L, 5 L, 10 L |
| Mixing Mode | 180° vertical inversion agitation with continuously variable speed control |
| Reagent Dispensing Precision | ±0.1 mL |
| Temperature Control | 360° electromagnetic induction annular heating (optional water bath) |
| Dimensions (W×D×H) | 60 × 60 × 72 cm |
| Weight | 68 kg |
| Power Supply | 110/220 V, 50/60 Hz |
| Max Peptide Length | 100 residues |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI586 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 5–50 / 10–100 / 25–200 mmol |
| Reactor Count | 1 |
| Reactor Volume Options | 1L & 5L / 2L & 10L / 5L & 20L |
| Syringe Pump Precision | ±1 mL |
| Synthesis Purity | ≥99.5% |
| Solvent Flow Rate | 1–2 L/min |
| Brand | Dilun Bio |
|---|---|
| Origin | Beijing, China |
| Model | 486 Pro |
| Amino Acid Addition | Automated |
| Reagent Addition | Automated |
| Synthesis Scale | 2–60 mmol |
| Reactor Count | 2 |
| Reactor Volume Options | 0.5 / 1 / 2 L and 1 / 2 / 5 L |
| Amino Acid Positions | 6 or 8 |
| Solvent Ports | 5 or 7 |
| Solvent Reservoir Capacity | 10 / 20 / 50 L |
| Mixing Mechanism | 180° bidirectional mechanical inversion with infinitely variable speed control |
| Power Supply | 110/220 V, 50/60 Hz |
| Dimensions (W×D×H) | 770×600×750 mm or 850×850×900 mm |
| Weight | 68 kg or 110 kg |
| Quantitative Dispensing Accuracy | ±1 mL |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | PSI413 |
| Synthesis Scale | 2.5–20 mmol per channel |
| Reactor Configuration | 1 or 2 reactors |
| Reactor Volumes | 0.5 L, 1 L, 2 L (jacketed) |
| Amino Acid & Reagent Addition | Manual |
| Syringe Pump Accuracy | ±0.1 mL |
| Solvent Flow Rate | 200 mL/min |
| Mixing Mechanism | Reactor Inversion (stirrer-free) |
| Coupling Efficiency | ≥99.5% |
| Temperature Control | Water Bath |
| Agitation Speed | 0–25 rpm (infinitely adjustable) |
| Solvent Reservoirs | 4 |
| Power Supply | 220 V, 50/60 Hz, 1 kW |
| Inert Atmosphere | N₂ or Ar throughout synthesis |
| Maximum Peptide Length | >100 residues |
| Construction Material | 304 Stainless Steel |
| Compliance | Designed for GLP-compliant peptide process development and scale-up |
| Brand | Dilun Bio |
|---|---|
| Origin | Beijing, China |
| Model | 286Max |
| Synthesis Scale | 2–25 mmol |
| Number of Reactors | 3 |
| Reactor Volume Options | 0.5 / 1 / 2 L |
| Amino Acid Positions | 10 (250 mL bottles) |
| Solvent Positions | 5 (20 L / 50 L tanks) |
| Dispensing Accuracy | ±1 mL |
| Activation Modes | Simultaneous & Pre-activation |
| Amino Acid Delivery | Automated quantitative weighing & dissolution-transfer |
| Reagent Delivery | Automated precise aspiration |
| Mixing Mechanism | 180° mechanical flip agitation |
| Power Supply | 110/220 V, 50/60 Hz |
| Dimensions (W×D×H) | 108 × 62 × 90.5 cm |
| Weight | 87 kg |
| Brand | PSI |
|---|---|
| Origin | Beijing, China |
| Model | Dilun-PS |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Operator Authentication | Password + Facial Recognition |
| Audit Trail | Yes |
| Synthesis Scale | 1–10 mol |
| Reactor Quantity | 1 |
| Reactor Volume Range | 50 L – 2000 L |
| Syringe Pump Accuracy | ±0.1% |
| Crude Peptide Purity | ≥99.5% |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI286 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 0.25–3 mmol per reactor |
| Reactor Count | 1–3 (configurable) |
| Reactor Volumes | 50 mL, 100 mL, 200 mL (jacketed) |
| Syringe Pump Accuracy | ±0.01 mL |
| Coupling Efficiency | ≥99.5% |
| Solvent Flow Rate | 2–4 mL/s |
| Mixing Mode | Stirring-Free Reactor Inversion (180° mechanical oscillation) |
| Mixing Speed | 0–30 rpm, continuously adjustable |
| Construction Material | 304 stainless steel |
| Power Supply | 110/220 V, 50/60 Hz |
| Host Power | 1 kW |
| Weight | 100–150 kg |
| Dimensions (W×D×H) | 113×52×72 cm (1-channel) |
| Brand | Dilun Bio |
|---|---|
| Origin | Beijing, China |
| Model | 386 Pro |
| Amino Acid Delivery | Automated quantitative dispensing (0.1 mL precision) |
| Reagent Delivery | Automated quantitative dispensing (0.1 mL precision) |
| Synthesis Scale | 0.01–0.6 mmol |
| Reaction Vessel Count | 1 |
| Reaction Vessel Capacity | 10/25 mL |
| Heating Method | 360° circumferential electromagnetic induction hot-air heating |
| Mixing Mechanism | Vortex oscillation + nitrogen bubbling |
| Amino Acid Positions | 28 |
| Activator Positions | 4 |
| Solvent Positions | 4–6 |
| Solvent Reservoir Options | 0.5 L, 1 L, 2 L, 5 L, 10 L |
| Power Supply | 110/220 V, 50/60 Hz |
| Dimensions (W×D×H) | 82 × 62 × 92 cm |
| Weight | 75 kg |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI486 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 2.5–20 mmol |
| Reactor Count | 1 |
| Reactor Volumes | 0.5 L, 1 L, 2 L (jacketed) |
| Syringe Pump Accuracy | ±0.1 mL |
| Synthesis Purity | ≥99.5% |
| Solvent Flow Rate | 200 mL/min |
| [Brand | ACT/Tetras |
|---|---|
| Origin | USA |
| Model | Tetras 106-Channel Peptide Synthesizer |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale per Reactor | 30–1000 µmol or 0.01–3 g resin |
| Max Reactor Count | ≤106 |
| Reactor Volumes | 6 mL, 25 mL, 40 mL, 60 mL |
| Syringe Pump Accuracy | <1% |
| Synthesis Purity | ≥99.5% |
| Flow Rate | 0.25–1 mL/s] |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI419 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale per Channel | 2.5–20 mmol |
| Number of Reaction Vessels | 2 |
| Vessel Capacities | 0.5 L, 1 L, 2 L (jacketed) |
| Syringe Pump Accuracy | ±0.1 mL |
| Synthesis Purity | ≥99.5% |
| Solvent Flow Rate | 200 mL/min |
| Brand | Dilun Bio |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 686 |
| Quotation | Upon Request |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | ≥0.3 mol |
| Reaction Vessel Count | 4 |
| Reaction Vessel Capacity Options | 20/50 mL, 50/100 mL, 150/300 mL, 300/500 mL |
| Reactor Volume Range | 20–2000 L |
| Reactor Material | 304 stainless steel shell with 316L stainless steel lining |
| Solvent Port Count | ≤9 |
| Stirring Mode | Mechanical agitation |
| Amino Acid Activation Vessel Material | 304 SS shell / 316L SS lining |
| Piperidine Buffer Vessel Material | 304 SS shell / 316L SS lining |
| Explosion Protection Rating | Exia IIC T4 GB |
| Power Supply | 220/380 V AC |