| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660A6B3M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 / 6 / 9 / 12 (configurable) |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Repeatability | <0.5% RSD (standard reference material) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BSD-660 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 / 6 / 9 / 12 configurable |
| Pore Size Range | 0.35–500 nm |
| Analytical Theories Supported | BET surface area, BJH pore size distribution (mesopores), DR & HK (Original) micropore analysis, DFT-based pore modeling, IASTL multi-component adsorption modeling |
| Repeatability | ≤0.5% RSD (certified standard reference materials) |
| Key | Brand: Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 12 |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | down to 1 × 10⁻⁹ Pa |
| Analytical Theory | Static Gravimetric/Volumetric Adsorption |
| Repeatability | ≤0.01% RSD (on certified reference materials) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660 Series |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 / 6 / 9 / 12 configurable |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Pressure Range | 10⁻² Pa (standard) |
| Test Theory | Static Volumetric Adsorption |
| Repeatability | ≤1% RSD |
| Key | Brand: Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption |
| Analysis Stations | 6 Mesopore Stations + 6 Micropore Stations |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Vacuum Level | ≤10⁻² Pa (standard), optional molecular pump for ≤10⁻⁸ Pa |
| Repeatability | ≤1% RSD |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | BSD-660MG |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 / 6 / 9 / 12 (configurable) |
| Specific Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Pressure Range | Ambient pressure (up to 1000 torr) with ultra-low-pressure capability down to P/P₀ = 1×10⁻⁸ |
| Repeatability | Quantitative error <0.5% RSD (BET standard reference material) |
| Vacuum System | Turbo-molecular pump achieving ultimate vacuum ≤1×10⁻⁸ Pa |
| Gas Compatibility | N₂, O₂, Ar, CO, CO₂, H₂, CH₄, C₂H₆ (non-corrosive & flammable gases) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | BSD-660A6S |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Method (Static Capacity Method) |
| Analysis Stations | 3 / 6 / 9 / 12 configurable |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Pressure Range | 0–1000 torr & 0–1 torr (dual-range transducers) |
| Repeatability | ≤0.5% RSD (certified reference material) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BSD-PBx |
| Price Range | USD 14,000 – 42,000 (FOB) |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Operating Principle | Static Gas Pressure Method (Bubble Point & Gas Flow) |
| Number of Analysis Stations | 1 |
| Pore Size Range | 0.02 – 500 µm |
| Pressure Range | 0–1 bar & 0–40 bar (dual-range, auto-switching) |
| Test Theory | Gas Bubble Point Method |
| Repeatability | ±0.01 µm (on certified reference membranes) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Model | BSD-660A3M |
| Analysis Stations | 3 / 6 / 9 / 12 |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Vacuum Level | ≤1×10⁻² Pa (standard), optional turbomolecular pump for ≤1×10⁻⁸ Pa |
| Measurement Principle | Static Volumetric Gas Adsorption |
| Repeatability | <0.5% RSD for surface area, pore size, pore volume, and adsorbed quantity (certified reference materials) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | BSD-660A3MB3M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 3 / 6 / 9 / 12 configurable |
| Surface Area Range | ≥ 0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Vacuum Level | Standard: 1×10⁻² Pa |
| Optional Turbo-Molecular Pump | ≤ 1×10⁻⁸ Pa |
| Repeatability | < 0.5% RSD (certified reference material) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | BSD-660A3S |
| Instrument Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 3 / 6 / 9 / 12 |
| Pore Size Range | 0.35–500 nm |
| Specific Surface Area Range | ≥0.0005 m²/g |
| Vacuum Level | ≤1×10⁻⁹ Pa |
| Temperature Control Accuracy | ±0.1 °C (RT–400 °C) |
| Quantitative Repeatability | <0.5% RSD (BET standard reference material) |
| Adsorption Gases | N₂, O₂, Ar, CO, CO₂, H₂, CH₄, C₂H₆ (non-corrosive & combustible) |
| Optional Thermal Control | –10–80 °C (with恒温 water bath) or 100 K–RT (with LNT level stabilization) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | BSD-660A3M / BSD-660B3M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Method (Static Capacity Method) |
| Number of Analysis Stations | 3 / 6 / 9 / 12 |
| Surface Area Range | ≥0.0005 m²/g (no upper limit) |
| Pore Diameter Range | 0.35–500 nm (Micropores: 0.35–2 nm |
| Mesopores | 2–50 nm |
| Macropores | 50–500 nm) |
| Total Pore Volume Range | ≥0.0001 cm³/g (no upper limit) |
| Pressure Ranges | 0–1000 torr, 0–1 torr, 0–0.1 torr (selectable) |
| Repeatability | ≤±1.0% |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Method (Static Capacity Method) |
| Analysis Stations | 3 / 6 / 9 / 12 configurable |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Repeatability | ±0.01 (RSD) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Model | BSD-660A6M |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 (micro-pore configuration) |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Vacuum Level | ≤1×10⁻² Pa (standard), optional turbo-molecular pump for ≤1×10⁻⁸ Pa |
| Repeatability | ≤1% RSD |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | BSD-660A3S / BSD-660B3S |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method (BET, t-plot, DFT/NLDFT, BJH, HK, DA, etc.) |
| Number of Analysis Stations | 3 / 6 / 9 / 12 |
| Specific Surface Area Range | ≥0.0005 m²/g (no upper limit) |
| Pore Diameter Range | 0.35–500 nm (Micropores: 0.35–2 nm |
| Mesopores | 2–50 nm |
| Macropores | 50–500 nm) |
| Total Pore Volume Range | ≥0.0001 cm³/g (no upper limit) |
| Pressure Range | 1×10⁻⁸–1000 Torr |
| Vacuum Level | ≤1×10⁻⁹ Pa |
| Repeatability | ≤±1.0% RSD (BET surface area on certified reference materials) |
| Key | Brand: Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Method (Gas Adsorption) |
| Analysis Stations | 3 / 6 / 9 / 12 configurable |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Pressure Range | 1×10⁻⁹ Pa (ultimate vacuum) |
| Repeatability | ≤±0.5% RSD (BET standard reference material) |
| Temperature Control | Programmable heating (room temp to 400 °C, ±0.1 °C accuracy) |
| Gas Compatibility | N₂, Ar, O₂, CO, CO₂, H₂, CH₄, C₂H₆, and optional corrosive gases (e.g., NH₃, SO₂) and vapors (e.g., H₂O, ethanol) |
| Compliance | ASTM D3663, ISO 9277, ISO 15901-1/2/3, GB/T 19587–2017, GB/T 21650.1–2008, GB/T 21650.2–2008, GB/T 21650.3–2011 |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660A6S |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method (Static Capacity Method) |
| Number of Analysis Stations | 1–4 |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | Ambient Pressure |
| Repeatability | ≤ ±1.0% |
| Vacuum Level | Up to 1×10⁻⁹ Pa |
| BET Surface Area Range | ≥0.0005 m²/g |
| Temperature Control Accuracy | Better than ±0.1°C (RT–400°C) |
| Adsorption Gases | N₂, O₂, Ar, CO, CO₂, H₂, CH₄, C₂H₆, etc. |
| Optional Functions | Cryogenic temperature control (100 K–80°C), corrosive gas compatibility, vapor adsorption, LIMS integration |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660A6MB6M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 / 6 / 9 / 12 |
| Specific Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Ultimate Vacuum | ≤1×10⁻⁹ Pa |
| Theoretical Basis | Static Gravimetric/Volumetric Gas Adsorption |
| Repeatability | <0.5% RSD |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660A6S/B3M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Gas Adsorption (Manometric Method) |
| Number of Analysis Stations | 3 / 6 / 9 / 12 |
| Specific Surface Area Range | ≥0.01 m²/g |
| Pore Size Range | Micropores 0.35–2 nm, Mesopores 2–50 nm, Macropores >50 nm |
| Pressure Range | Up to 10 MPa |
| Repeatability | ≤±0.5% RSD (BET surface area on certified reference materials) |
| Vacuum Level | ≤1×10⁻⁹ Pa |
| Temperature Control Accuracy | ±0.1 °C (programmable from ambient to 400 °C) |
| Adsorption Gases | N₂, Ar, CO₂, O₂, CO, H₂, CH₄, C₂H₆, and corrosive gases (with optional configuration) |
| Vapor Adsorption | Optional with thermostatic bath (−10 to 80 °C) or liquid nitrogen temperature control (100 K to ambient) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660A6M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 6 |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Vacuum Level | 10⁻² Pa (standard), down to 10⁻⁸ Pa with optional turbomolecular pump |
| Repeatability | ≤1% RSD |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | 3H-2000PS1X |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method (Static Capacity Method) |
| Number of Analysis Stations | 1–8 configurable |
| Specific Surface Area Range | 0.0005 m²/g to unlimited |
| Pressure Range | 10⁻² Pa |
| Repeatability | ≤ ±0.01 (relative standard deviation) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BSD-PM |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method (Gas Adsorption) |
| Number of Analysis Stations | 1–12 |
| Specific Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Pressure Range | 0–1000 Torr (with optional 0–0.1 Torr high-resolution sensor) |
| Repeatability | ≤±0.01% for surface area, ≤±0.02 nm for most probable pore diameter |
| Vacuum Level | PS Series — 4×10⁻² Pa |
| Degassing Stations | 2 independent thermal treatment stations (RT–400 °C, ±0.1 °C control accuracy) |
| Independent P₀ Station | Patented helical saturation vapor pressure station |
| Compliance Standards | GB/T 19587–2017, ISO 9277:2010, ISO 15901-1/2/3:2005–2007, GB/T 39713–2020, GB/T 21650.1–3, GB/T 13390–2008, GB/T 10722–2014, GB/T 7702.20–2008, GB/T 6609.35–2009 |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | BSD-AD8 |
| Instrument Type | Specific Surface Area Analyzer Pre-treatment Unit |
| Analysis Stations | 8 |
| Pressure Range | Up to 1 atm (ambient) |
| Testing Principle | Dynamic Purge Method (Gas Flow Desorption) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-660A6M / B6M |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 / 6 / 9 / 12 |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | 0–1000 torr |
| Theoretical Capabilities | Adsorption/desorption isotherm measurement |
| Repeatability | ≤0.5% RSD |