Hach
Filter
Showing 91–120 of 371 results
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | CRM-2C |
| Measurement Range | 0–0.5 mg/L or 0–1.0 mg/L (manually selectable) |
| Repeatability | ±5% FS |
| Light Source | LED @ 565 nm |
| Measurement Interval | 5–120 min (1-min adjustable increments) |
| Analysis Time | 5–11 min (1-min adjustable increments) |
| Display | 30×8-digit LED |
| Analog Output | 4–20 mA or 0–1 V DC (max. load 700 Ω) |
| Relay Outputs | Configurable alarm signals |
| Alarm Threshold Range | 0.1–0.5 mg/L or 0.1–1.0 mg/L (0.1 mg/L step) |
| Digital Interface | RS232C (optional) |
| Sample Flow Rate | 1–3 L/min (with pretreatment tank) |
| Sample Volume per Cycle | 300 mL |
| Sample Temperature | 0–40 °C (non-freezing) |
| Sample Pressure | 0.2–0.8 kgf/cm² |
| Power Supply | 220 VAC, 50/60 Hz |
| Power Consumption | ~60 VA |
| Operating Environment | Indoor installation |
| Weight | 16 kg |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Status | Manufacturer |
| Instrument Type | Online Water Sampler |
| Sampling Mode | Proportional Composite Sampling |
| Maximum Single Sample Volume | 390 mL |
| Sampling Flow Rate | 200 mL/min |
| Sampling Interval Control | Programmable up to 390 mL per interval |
| Sampling Depth | Surface-level intake (no submersible probe) |
| Pre-treatment Options | Ultrasonic homogenization (for COD<sub>Cr</sub>, TP, TN) and precision filtration (for NH<sub>3</sub>-N) |
| Communication Interface | Digital RS-485/Modbus RTU |
| Display | 10-inch TFT color touchscreen |
| Compliance | Designed per HJ 353–2019 and HJ 355–2019 (China EPA) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Pen-style |
| Parameter Types | Dual (pH & ORP) |
| Measurement Range | pH 0–14, ORP −1500 to +1500 mV |
| Resolution | 0.01 pH |
| Calibration Buffers | pH 4.01, 7.00, 10.01 |
| Sensor Interface | Digital (HACH SC Series Protocol) |
| Cable Length | 4.5 m integrated |
| Digital Adapter Included | Part #6120600 (for legacy analog sensor retrofit) |
| Temperature Compensation | Integrated Pt1000 RTD |
| Housing Materials | Ryton®, PVDF, or 316SS/PVDF (model-dependent) |
| Compliance | Designed for ASTM D1293, ISO 10523, USP <791>, and EPA 150.1–compliant monitoring workflows |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 3700 Series Electrodeless Conductivity Sensor |
| Connection Interface | Digital (SC100/SC1000 Compatible) |
| Sensor Body Materials | Polypropylene (PP), Polyvinylidene Fluoride (PVDF), Perfluoroalkoxy (PFA), Polyetheretherketone (PEEK) |
| Process Connections | 2" Sanitary Clamp or 2" NPT |
| Standard Cable Length | 6 m (with 1 m extension cable and digital adapter D6120800) |
| Compliance | Designed for continuous online water quality monitoring in compliance with ISO 7888, ASTM D1125, and USP <645> conductivity requirements |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 3400 Series Digital Conductivity Sensor |
| Sensor Constants | 0.05, 0.5, 1.0, 5.0, 10 cm⁻¹ |
| Cell Materials | Titanium (D3422), Graphite (D3433), 316 Stainless Steel (D3444/D3455), Sanitary 316SS with Hygienic Flange (D3455) |
| Connection Interface | Digital Bus (HACH Smart Sensor Protocol) |
| Cable Length | 6–7 m standard (with 1 m extension kit included for D3433/D3444/D3455) |
| Compatible Controllers | SC100 and SC1000 Universal Digital Controllers |
| Mounting Types | Insertion (D3422), Submersible (requires analog 3422 analog variant), Sanitary Flanged (D3455) |
| Enclosure Material | PVDF or Ryton per model |
| Electrical Interface | Integrated digital bus connector with auto-ID and calibration memory |
| Brand | HACH |
|---|---|
| Model | pH/ORP Digital Sensor |
| Origin | Imported |
| Manufacturer | HACH Company |
| Sensor Interface | Digital (HACH SC Series Compatible) |
| Cable Options | 4.5 m integrated cable (standard), 10 m cable (6120600/6120500 variants) |
| Temperature Rating | Up to 70°C (PEEK/Ryton models), 60°C (stainless steel models) |
| Electrode Types | Glass pH (standard & HF-resistant), Pt or Au ORP |
| Materials | Ryton®, PVDF, 316SS, PEEK |
| Temperature Compensation | Integrated Pt1000 RTD |
| Compliance | Designed for continuous online water quality monitoring per ISO 5667, ASTM D1293, USP <791>, and EPA Method 150.1 |
| Brand | HACH |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | AUT-701 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 0–14 |
| Burette Reading Accuracy | ±0.01 mL |
| Burette Resolution | 0.00005 mL |
| Titration Precision | ±0.1% |
| Simultaneous Titration Channels | 2 |
| Electrode Inputs | Up to 4 (pH/mV standard |
| Maximum Burettes Supported | 10 |
| Data Storage Capacity | 100 methods per system (expandable to 200) |
| Connectivity | USB (hot-swappable), LAN (standard), RS-232 (optional) |
| Validation Support | Built-in electrode calibration logging, burette volume verification, optional temperature/humidity environmental monitoring |
| Brand | HACH |
|---|---|
| Manufacturer | DKK Toa Corporation |
| Model | BPM-2000 |
| Origin | Japan |
| Compliance | ASTM D86, ASTM D1160, GB/T 6536, GB/T 9168 |
| Explosion Protection | NEPSI Ex dpx IIB+H2 T4 Gb (Cert. No. GYJ14.1186x) |
| Operating System | Windows XP/7 Embedded |
| Display | 10" Color Touchscreen Interface |
| Communication | RS485 MODBUS RTU (up to 15 addresses, baud rates up to 115.2 kbps) |
| Sample Volume | 50 mL |
| Resolution | 0.15 vol% per temperature point |
| Vacuum Option | Optional ASTM D1160-compliant vacuum distillation module |
| Specialized Components | Coated stainless-steel distillation flask, explosion-proof sample cooler (SCU-02), sample conditioning unit, waste recovery unit, voltage stabilizer |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | FBM-160 / FBM-100A |
| Measurement Range | 0–99.9 mg/L, 0–999 mg/L, 0–9990 mg/L |
| Temperature Output (FBM-160 only) | 0.0–50.0 °C |
| Linearity | ±8% FS (controller) |
| Repeatability | ±5% FS (controller) |
| 90% Response Time | ≤60 s |
| Analog Output | DC 4–20 mA (650 Ω, isolated) |
| Digital Output | RS-232C (optional) |
| Alarm Outputs | 4 configurable |
| Power Supply | AC 90–264 V, 50/60 Hz |
| Environmental Rating | IP65 (FBM-160), IP30 (FBM-100A) |
| Operating Ambient | −20 to +55 °C, ≤95% RH |
| Sample pH Range | 4–9 |
| Sample Temperature | 0–40 °C (non-freezing) |
| Minimum Conductivity | 50 mS/m (500 µS/cm) |
| Flow Rate | 0.01–0.2 m/s |
| Interference Constraints | Avoid high concentrations of Ca²⁺, Al³⁺, Fe³⁺ |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | DKK Toa (Japan), Distributed by HACH |
| Model Series | GSS-304A/B/F, GSS-314A/B/F, PSS-304B, PSS-314B, ASS-304B, ASS-314B |
| Sensor Type | Replaceable pH/ORP/Conductivity Electrodes with Non-refillable or Refillable KCl Reference Systems |
| Body Material | Polyphenylene Sulfide (PPS/Ryton®) |
| Operating Temperature Range | 5–100 °C (model-dependent) |
| Max Pressure Rating | 0.2–0.5 MPa |
| Minimum Conductivity for Stable pH Measurement | 100–1000 µS/cm |
| Electrode Mounting Options | Immersion, Insertion (Pipe), Flow-Through, Ultrasonic/Chemical/Pneumatic Cleaning Compatible |
| Compliance | Designed for continuous industrial water and wastewater monitoring per ISO 5667, ASTM D1293, USP <791>, and GLP/GMP-aligned operational traceability |
| Brand | HACH |
|---|---|
| Manufacturer Origin | Japan (DKK Corporation) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | HSCA-2000 |
| Measurement Principle | Energy-Dispersive X-Ray Fluorescence (EDXRF) |
| Detection Range | 0–10 ppm to 0–1000 ppm (user-selectable) |
| Repeatability | ±2% of full scale |
| Linearity | ±2% of full scale |
| Sample Temperature Limit | ≤60°C |
| Sample Pressure Limit (inlet to flow cell) | ≤0.5 MPa |
| Flow Cell Material | SUS304 stainless steel, Viton seals, coated beryllium window |
| X-ray Source | Low-power end-window micro-focus X-ray tube (9.9 W) |
| Detector | High-sensitivity low-background proportional counter |
| Measurement Cycle | 10–999 s (adjustable) |
| Enclosure Rating | IP55 |
| Explosion Protection | NEPSI Ex dpx IIB+H2 T4 Gb (Cert. No. GYJ11.1655) |
| Power Supply | 90–240 VAC, 50/60 Hz, 70 VA |
| Ambient Operating Conditions | 0–50°C, ≤85% RH |
| Analog Output | 4–20 mA DC (600 Ω load) |
| Alarm Output | 1 dry contact (NC, 0.5 A / 30 VAC or DC) |
| Communication Options | MODBUS RTU/TCP, HART, Ethernet (optional) |
| Utility Requirements | Instrument air (0.4–1.0 MPa, 20 NL/min), helium purge gas (0.5–1.0 MPa, 10–20 NmL/min), optional cooling water |
| Brand | HACH |
|---|---|
| Manufacturer | DKK Toa Corporation |
| Model | ODL-1600 |
| Origin | Japan |
| Instrument Type | Surface Oil Film Detection System |
| Compliance | Designed for continuous oil-in-water monitoring in industrial discharge and intake protection applications |
| Pricing | Available upon request |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | DKK TOA Corporation |
| Model | SPCP-20 |
| Explosion Protection | IEC Ex ia IIC T4 Ga (Cert. Nos. C12661–C12664) |
| Temperature Compensation Range | 0–100 °C (manual, via external thermistor) |
| Temp. Coefficient Adjustment Range | −0.100 to +0.100 pH/°C |
| Output Signal | 4–20 mA DC (two-wire loop-powered) |
| Housing | Die-cast aluminum, adjustable mounting angle |
| Diagnostic Capabilities | Electrode fracture detection, thermistor open/short, hardware fault monitoring |
| Operating Mode Options | Measurement mode / Maintenance mode (output hold: last value, user-defined setpoint, or live reading) |
| Compliance | IEC 60079-0, IEC 60079-11, NEMA 4X equivalent ingress protection |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | SRCP-20 |
| Certification | IECEx/ATEX Ex ia IICT4 (Cert. No. TC15214) |
| Measurement Range | −2000 to +2000 mV |
| Temperature Display Range | 0–100 °C |
| Output | 2-wire 4–20 mA DC, isolated |
| Power Supply | 17.2–27 V DC |
| Accuracy (Output Linearity) | ±0.6% FS |
| Repeatability | < ±3 mV |
| Environmental Rating | IP65 |
| Operating Temperature | −20 to +55 °C |
| Relative Humidity | < 99% RH |
| Enclosure Material | Die-cast aluminum |
| Weight | 2 kg |
| Mounting | 2″ pipe (60.5 mm O.D.) or wall-mount |
| Cable Entry | 3×NPT |
| Brand | HACH |
|---|---|
| Manufacturer Origin | Japan (DKK Corporation) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | SSM-21P |
| Pricing | Upon Request |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | DR/2800 + DRB200 |
| Detection Principle | Colorimetric Measurement after Micro- reflux Digestion (Cr⁶⁺ Reduction) |
| COD Range | 0–15,000 mg/L O₂ (via pre-filled vials) |
| Digestion Temperature | 150 °C ±2 °C |
| Digestion Time | 120 min |
| Vial Format | Sealed 3-mL预制试剂管 (0.2–2 mL sample volume) |
| Compliance | ASTM D1253, ISO 6060, EPA 410.4, USP <643>, GLP-ready data logging |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Wavelength Range | 340–900 nm |
| Optical Bandwidth | 5 nm |
| Wavelength Selection | Method-Driven Automatic Selection |
| Wavelength Calibration | Fully Automatic |
| Readout Modes | Transmittance (%T), Absorbance (A), Concentration (mg/L, ppm, etc.) |
| Interface | USB 1.1 |
| Power Supply | AC Input (100–240 V, 47–63 Hz) or Rechargeable Lithium-ion Battery |
| Weight | 4.06 kg (instrument only), 4.38 kg (with battery) |
| Operating Environment | 10–40 °C, ≤90% RH (non-condensing) |
| Data Storage Capacity | 500 test records with timestamp, sample ID, operator code, and result metadata |
| Display | Touchscreen LCD with Chinese-language menu support |
| Sample Compatibility | Hach TNTplus™ pre-filled reagent vials with barcode recognition |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DR/5000 |
| Optical Design | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm (200–900 nm) |
| Spectral Bandwidth | 2 nm |
| Wavelength Resolution | 0.1 nm |
| Stray Light | <0.05% T at 220 nm |
| Absorbance Range | ±3.0 ABS |
| Measurement Modes | Transmittance (%T), Absorbance (ABS), Concentration |
| Data Storage Capacity | 2000 data points with timestamp, sample ID, operator code, and result |
| Interface | USB 1.1 (to PC, printer, external keyboard) |
| Power Supply | 200–240 V, 50/60 Hz |
| Weight | 15.5 kg |
| Operating Environment | 10–40 °C, ≤90% RH (non-condensing) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DR/800 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measured Parameters | Multi-Parameter |
| Wavelength Range (DR/890) | 420, 520, 560, 610 nm |
| Wavelength Range (DR/850) | 520, 610 nm |
| Wavelength Range (DR/820) | 520 nm |
| Wavelength Accuracy | ±1 nm |
| Photometric Range | 0–2 A |
| Wavelength Selection | Automatic |
| Readout Modes | % Transmittance, Absorbance, Concentration |
| Data Storage Capacity | 99 measurements |
| Interface | Infrared (IR) via Data Transfer Adapter to RS-232 serial port |
| Power Supply | 4 × AA alkaline batteries |
| Weight | 470 g |
| Operating Environment | 0–50 °C, ≤90% RH (non-condensing) |
| Standard Curves Stored | DR/890 – 90, DR/850 – 50, DR/820 – 20 |
| Reagent Compatibility | Powder pillows, ampoules, pre-filled TNT tubes |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Dichromate Digestion Method (Portable-Compatible Design) |
| Wavelength Options | 420 nm and 610 nm |
| Wavelength Accuracy | ±1 nm |
| Photometric Linearity | ±0.002 A (0–1 A) |
| Photometric Repeatability | ±0.005 A (0–1 A) |
| Photometric Accuracy | ±0.005 A at 1.0 ABS |
| Stray Light | <1.0% at 400 nm |
| Light Source | LED |
| Detector | Silicon Photodiode |
| Display | 4-digit LCD, 15 mm character height |
| Optical Range | 0–2 A |
| Readout Modes | % Transmittance, Absorbance, Concentration |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–60 °C |
| Humidity Limit | 80% RH at 40 °C |
| Ingress Protection | IP41 |
| Power Supply | 190–240 VAC/50 Hz adapter (6 VDC output) or 4 × AA alkaline batteries |
| Battery Life | Up to 6 months (typical usage) |
| Dimensions | 24.0 × 19.8 × 12.0 cm |
| Weight | 2.0 kg |
| Batch Capacity | 0–30 samples per run |
| Digestion Time | 20–120 min |
| Detection Limit & Range | Defined by reagent vial selection (e.g., 0–150 mg/L, 0–1500 mg/L) |
| Measurement Error | ≤8% (15–150 mg/L) |
| Data Interface | RS232 serial port for printer or PC connectivity |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DR1010 |
| Pricing | Available Upon Request |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | DR1010 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Spectrophotometric (Dichromatic Absorption at 420 nm and 610 nm) |
| Wavelength Accuracy | ±1 nm |
| Photometric Linearity | ±0.002 A (0–1 A) |
| Photometric Repeatability | ±0.005 A (0–1 A) |
| Photometric Accuracy | ±0.005 A at 1.0 ABS |
| Light Source | LED |
| Detector | Silicon Photodiode |
| Display | 4-digit LCD, 1.5 cm character height |
| Optical Range | 0–2 A |
| Drift | <1.0% at 420 nm |
| Power Supply | 6 VDC adapter (190–240 VAC/50 Hz) or 4 × AA alkaline batteries |
| Battery Life | Up to 6 months (typical usage) |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–60 °C |
| Relative Humidity | ≤80% at 40 °C |
| Enclosure Rating | IP41 |
| Dimensions | 24.0 × 19.8 × 12.0 cm |
| Weight | 2.0 kg |
| Data Interface | RS232 serial port |
| Readout Modes | % Transmittance, Absorbance, Concentration |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | DR1010 COD |
| Instrument Type | Portable |
| Measurement Principle | UV-Visible Absorption Spectrophotometry |
| Wavelengths | 420 nm and 610 nm |
| Photometric Accuracy | ±0.005 A at 1.0 ABS |
| Photometric Repeatability | ±0.005 A (0–1 A) |
| Wavelength Accuracy | ±1 nm |
| Photometric Linearity | ±0.002 A (0–1 A) |
| Detector | Silicon Photodiode |
| Power Supply | 190–240 V AC/50 Hz or 4×AA Alkaline Batteries |
| Environmental Rating | IP41 |
| Output Interface | RS232 Serial Port |
| Readout Modes | % Transmittance, Absorbance, Concentration |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DR1300 FL |
| Price | Upon Request |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DR2700 |
| Wavelength Range | 400–900 nm |
| Optical Bandwidth | 5 nm |
| Wavelength Selection | Automatic (method-driven) |
| Wavelength Calibration | Automatic |
| Measurement Modes | Transmittance (%), Absorbance, Concentration |
| Preloaded Methods | >130 |
| User-Defined Methods | 10 |
| Data Storage Capacity | 200 measurements |
| Display Interface | Touchscreen with Chinese language option |
| Power Supply | AC 100–240 V, 47–63 Hz |
| Weight | 4.0 kg (without battery), 4.3 kg (with battery) |
| Operating Environment | 10–40 °C, ≤80% RH (non-condensing) |
| Connectivity | USB port for firmware updates, data export, and peripheral integration (e.g., printers, flash drives) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DR2800 |
| Price | Upon Request |
| Wavelength Range | 340–900 nm |
| Optical Bandwidth | 5 nm |
| Measurement Modes | Transmittance (%), Absorbance, Concentration |
| Data Storage Capacity | 500 test records |
| User-Defined Methods | Up to 50 |
| Preloaded Methods | 240+ |
| Power Supply | Rechargeable Li-ion battery or 100–240 V AC adapter |
| Weight | 4.06 kg (without battery), 4.38 kg (with battery) |
| Operating Environment | 10–40 °C, ≤90% RH (non-condensing) |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | DR2800 |
| Instrument Type | Laboratory & Field Water Quality Analyzer |
| Wavelength Range | 340–900 nm |
| Bandwidth | 5 nm |
| Optical Detection Principle | Absorbance-based Photometric Analysis |
| Readout Modes | Transmittance (%T), Absorbance (A), Concentration (mg/L, ppm, etc.) |
| Wavelength Selection | Automatic (method-driven) |
| Wavelength Calibration | Auto-calibrating via internal reference |
| Data Storage Capacity | 500 test records (including date, time, sample ID, operator code, result) |
| Power Options | Rechargeable Li-ion battery or universal AC adapter (100–240 V, 47–63 Hz) |
| Operating Environment | 10–40 °C, ≤90% RH (non-condensing) |
| Weight | 4.06 kg (instrument only), 4.38 kg (with battery) |
| Interface | USB 1.1 |
| Display | Touchscreen LCD with Chinese/English language support |
| Sample Adapters Included | A-type (1-cm square cuvettes), B-type (multi-path/flow-through cells), C-type (1-inch round vials & ampoules) |
| Preprogrammed Methods | >240 Hach-certified colorimetric water quality methods |
| Barcode Recognition | Yes (compatible with Hach TNTplus® pre-filled reagent vials) |