| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PH22 |
| Instrument Type | Pen-Style pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0.00–14.00 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Design | Flat-Surface pH Sensor |
| Minimum Sample Volume | 100 µL |
| Compliance | Designed for routine QC, field testing, and GLP-aligned workflows |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PH22 |
| Instrument Type | Pen-Style pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0.00–14.00 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) with integrated temperature sensor |
| Sample Volume Requirement | As low as 100 µL |
| Electrode Design | Flat-surface pH sensing element |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PI-200-I |
| Pricing | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PMA-51d |
| Explosion Protection | Ex d IIB+H2 T4 / Ex px d IIC T4X |
| Measurement Principle | Magnetic Mechanical (Magnetic Dumbbell Ball Method) |
| Target Gas | O₂ |
| Range Options | 0–5 vol% to 0–100 vol% O₂ |
| Repeatability | ±0.1 vol% O₂ (standard range) |
| Linearity | ±1.0% F.S. |
| Zero Drift | ±0.05 vol% O₂/week |
| Span Drift | ±0.05 vol% O₂/week |
| Response Time (T90) | ≤20 s |
| Sample Flow Rate | 300 mL/min |
| Sample Pressure | ≥1.98 kPa |
| Ambient Operating Temperature | –10 to +50 °C |
| Wetted Materials | SUS304, SUS316, Pt, Borosilicate Glass, FKM, SiO₂, Au |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | PP-TOFMS |
| Acquisition Rate | 1 spectrum per 30 µs |
| Mass Resolution | 5,000 at m/z 208 (high-resolution mode) |
| Dynamic Range | 10⁷ |
| Mass Accuracy | ±40 ppm |
| Sensitivity | 10³ cps/ppm |
| Depth Resolution | down to 1 nm |
| Ion Modes | Positive and Negative |
| Flexible Ion Gating | up to 4 ions |
| Sample Loading | Horizontal, tool-free |
| Mass Coverage | H to U, including isotopes and molecular species |
| RF Pulsed Glow Discharge Mode | Patented |
| Quantitative Capability | Matrix-effect-minimized semi-quantitative depth profiling without calibration standards |
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | QuantaMaster 8000 |
| Wavelength Range | UV–NIR (up to 5500 nm) |
| Monochromator Type | Triple-grating Czerny-Turner with 300 mm focal length |
| Slit Resolution (Spectral Bandpass) | 0.01 nm |
| Optical Resolution | 0.1 nm |
| Sensitivity | >30,000:1 (Water Raman SNR) |
| Wavelength Accuracy | ±0.3 nm |
| Excitation Sources | Up to 4 integrated sources including PowerArc™ Xe lamp and pulsed lasers (210–2200 nm) |
| Detection Channels | 6 configurable PMT/InGaAs/MCT channels |
| Lifetime Techniques | TCSPC, Strobe, SSTD (Single-Shot Time-Domain), up to 5500 nm |
| Automation | Fully motorized gratings, slits, mirrors, filter wheels, and accessory control via FelixGX software |
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Model | QuantaMaster 8000 |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Resolution | 0.1 nm |
| Slit Width (Spectral Bandpass) | 0–30 µm |
| Sensitivity | >30,000:1 (Water Raman SNR) |
| Dispersive Element | Grating |
| Pulse Excitation Capability | Up to 100 MHz |
| NIR Phosphorescence Lifetime Range | Up to 5500 nm |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ratio Master |
| Price Range | USD 65,000 – 130,000 (FOB) |
| Monochromator Type | Grating-Based |
| Spectral Bandpass | Adjustable down to <1 nm (typical operational minimum) |
| Wavelength Accuracy | ±0.2 nm (calibrated with Hg/Ne lamp traceable to NIST standards) |
| Detection Speed | Sub-2 ms wavelength switching |
| Temporal Resolution | ≤5 ms per dual-wavelength ratio frame (with optional high-speed PMT or sCMOS detection) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | RZ-660 |
| Price | Upon Request |
| Spectral Range | 680 – 3,800 cm⁻¹ |
| Spatial Resolution | < 5 µm |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model No. | 3200044490 |
| Instrument Type | Portable |
| Measurement Range | 0–200 mg/L (or ppm, as applicable) |
| Detection Limit | 0.1 mg/L |
| Accuracy | ±1% of reading |
| Resolution | 0.1 mg/L |
| Measurement Frequency | 0.5 test per minute |
| Compatible Analyzer Platform | HORIBA OCMA-300/310/350 series |
| Extraction Method | Liquid–Liquid Extraction |
| Analysis Principle (post-extraction) | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Solvent Recovery Compatibility | Yes, with HORIBA SR-305 Solvent Recovery System |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Instrument Type | Pen-Style pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0–14 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Type | Flat-Surface pH Sensor |
| Minimum Sample Volume | 100 µL |
| Compliance | Designed for routine QC, field testing, and educational use in accordance with ISO 7888 and ASTM D1293 guidelines |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | SA-9650 |
| Instrument Type | Specific Surface Area Analyzer |
| Measurement Principle | Dynamic Flow Method (Gas Adsorption) |
| Number of Analysis Stations | 1–3 |
| Specific Surface Area Range | 0.10 to >2000 m²/g |
| Repeatability | RSD < 1% |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Aqualog |
| Dispersion Element | Grating and Filter |
| Slit Width (Spectral Bandpass) | 5 nm |
| Resolution | 0.41 nm/pixel |
| Sensitivity | 20,000:1 (water Raman SNR, RMS, 350 nm excitation, 30 s integration) |
| Wavelength Accuracy | ±1 nm |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | DeltaPro |
| Dispersion Element | Grating and Interference Filters |
| Slit Width (Spectral Bandpass) | 1.0 nm to 32 nm |
| Optical Resolution | 1.0 nm |
| Sensitivity | >3000:1 |
| Wavelength Accuracy | ±0.5 nm |
| Detector Range (Standard) | 185–650 nm (upgradable to 850 nm or 900 nm) |
| Minimum Measurable Lifetime | 25 ps (with DeltaDiode/NanoLED) |
| Lifetime Range | 25 ps to 1 s (software-selectable source-dependent) |
| Excitation Sources | DeltaDiode (UV–NIR, 10 kHz–100 MHz rep. rate), NanoLED (UV–VIS, 10 kHz–1 MHz), SpectraLED (VIS–NIR, 0.1 Hz–10 kHz) |
| System Response FWHM | <200 ps (PPD/TBX + laser diode) |
| Dead Time | 10 ns |
| Time Range | 10 ns to 11 s (DeltaPro-DD configuration) |
| Interface | USB 2.0 (no PCI card required) |
| Operating System | Windows XP/7 (32-/64-bit English) |
| Dimensions (L×W×H) | 1875 mm × 1125 mm × 625 mm (excl. PC) |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | DeltaPro |
| Dispersion Element | Grating |
| Excitation Sources | NanoLED (up to 1 MHz), DeltaDiode (up to 100 MHz), SpectraLED (for phosphorescence, multi-wavelength) |
| Lifetime Range | 25 ps to >1 s |
| Detection Module | PPD photon counting detector (standard), optional NIR extension to ~1700 nm |
| Data Acquisition | Time-Correlated Single Photon Counting (TCSPC) with DeltaHub core (dead time: 10 ns) |
| Software Control | F-Link USB 2.0 interface, no PCI card required |
| Sample Compatibility | Liquid cuvettes (with temperature control & stirring), solid sample holders, large UV-grade sample chamber |
| Optional Accessories | Monochromators, motorized polarizers, automated optical components, PPD-850C/PPD-900C IR modules |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | DynaMyc |
| Detection Principle | Time-Correlated Single Photon Counting (TCSPC) |
| Lifetime Range | 100 ps – 10 µs |
| Spectral Detection Range | 185–650 nm / 300–850 nm (with TBX fast detector) |
| Spatial Resolution | 0.5 µm |
| Scan Stage Travel | 75 × 50 mm |
| Laser Source Options | Pulsed diode lasers (370–980 nm), DeltaDiode series, repetition rate up to 100 MHz, CW/pulsed mode selectable |
| Excitation Filtering | Motorized filter wheel with dichroic mirrors and pinholes (100–1000 µm) |
| Data Acquisition Modes | Single-point, multi-point, FLIM mapping |
| Software | DataStation (instrument control), DAS6 (lifetime decay analysis & deconvolution) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FluoroCube |
| Price Range | USD 65,000 – 130,000 (FOB) |
| Dispersive Element | Grating |
| Slit Width (Spectral Bandpass) | 1–32 nm |
| Spectral Resolution | 1 nm |
| Sensitivity | >3000:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±0.05 nm |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Fluorolog-3 |
| Wavelength Range (Optional) | 185 nm – 14 µm |
| Excitation/Emission Monochromators | Single or Dual Grating |
| Slit Width (Spectral Bandpass) | 0–20 nm |
| Optical Resolution | 0.06 nm |
| Sensitivity | 20,000:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±0.2 nm |
| Light Source | 450 W Xenon Arc Lamp |
| Detection Method | Photon Counting |
| Data Acquisition | TCSPC (Time-Correlated Single Photon Counting) for Lifetime Measurements |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | FluoroMax-4 |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth (Slit Width) | 0–30 nm |
| Optical Resolution | 0.2 nm |
| Sensitivity | >6000:1 (RMS method reported as up to 16,000:1) |
| Excitation Source | 150 W ozone-free Xenon lamp (vertically mounted) |
| Monochromator Type | Plane grating, Czerny-Turner design |
| Detection Mode | Photon counting |
| Optional Upgrades | TCSPC fluorescence lifetime module, phosphorescence lifetime unit, IR extension, integrating sphere, TIRF, Stop-Flow, polarization, temperature-controlled stages (Peltier & LN₂), microplate reader, microscope coupling |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Nanolog® |
| Excitation Source | 450 W continuous xenon lamp |
| Wavelength Range | UV–NIR (200–1700 nm, extendable to ~3 µm) |
| Spectral Resolution | 0.06 nm |
| Slit Width (Spectral Bandpass) | 0–20 nm |
| Wavelength Accuracy | ±0.2 nm |
| Sensitivity | >20,000:1 (at 1,550 nm, using liquid-nitrogen-cooled InGaAs array) |
| Detection Modes | Steady-state, time-resolved (TCSPC), and combined steady-state/time-resolved spectroscopy |
| Detector Options | PMT (UV–NIR), Symphony II InGaAs array (800–1700 nm |
| Lifetime Range | Fluorescence 100 ps–1 ms |
| Software | NanoSizer® for SWNT characterization (diameter distribution, FRET analysis), FluoroLog®-based acquisition and analysis suite |
| Compliance | Fully compatible with GLP/GMP data integrity requirements |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | Tempro |
| Excitation Source | Pulsed LED/Laser Diodes (255–NIR) |
| Detection Range | 185–650 nm (upgradable to 850 nm or 1700 nm with optional NIR detectors) |
| Lifetime Range | 100 ps to 1 s |
| Detection Method | Time-Correlated Single Photon Counting (TCSPC) |
| Wavelength Selection | Filter-based (monochromator optional) |
| Detector Type | PPD (Photon-Counting Photodiode) Module |
| Software | Horiba FluoroLog®-3 compatible analysis suite |
| Compliance | Designed for GLP/GMP environments |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | Signature SPM |
| Instrument Category | Atomic Force Microscope |
| Instrument Type | Materials-Focused AFM |
| Spectroscopy Integration | Confocal Raman & Photoluminescence (PL) |
| Core Capability | True Co-Localized Multimodal Imaging (Topography + Nanomechanics + Electrostatics + Magnetism + Chemical Fingerprinting) |
| Scanner Range | 100 × 100 × 15 µm |
| Optical Access | Dual-Path, IR AFM Laser (1310 nm) + Visible/NIR Excitation Lasers (e.g., 532 nm, 638 nm, 785 nm) |
| Spectrometer | Achromatic, >95% Reflectivity, Triple-Grating Support (150–6000 cm⁻¹) |
| Software Feature | “Probe Away” / “Probe Back” Automated Tip Retraction & Re-Registration |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | SLFA-20 |
| Detection Principle | Energy-Dispersive X-ray Fluorescence (ED-XRF) |
| Detection Limit | 20 ppm (3σ) |
| Measurement Range | 0–5 wt% (extended to 0–90 wt% with matrix correction) |
| Repeatability | ≤15 ppm (at 1 wt% S) |
| Analysis Time | 1–600 s (user-selectable) |
| Sample Volume | 4–10 mL |
| Dimensions | 250 × 407 × 138 mm |
| Weight | 8 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% RH at 5–31 °C, linearly decreasing to 50% RH at 40 °C |
| Spectral Range | 0–10 keV |
| Output Interface | RS-232C |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | 80 VA |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | SLFA-2100/2800 |
| Detection Principle | Wavelength-Dispersive X-ray Fluorescence (WDXRF) |
| Analyte | Total Sulfur in Petroleum Products |
| Detection Range | ≤5 ppm (at 1% sample mass loading) / ≤1.6 ppm (at 0% baseline) |
| C/H Correction Error | ±50 ppm per 1% C/H ratio (at 1% sample loading) |
| Detection Limit | <5 ppm |
| Calibration Curves | Up to 5 stored |
| Calibration Points | 2–20 points using certified reference materials |
| Sample Volume | 4–10 mL |
| Measurement Time | 10–600 s (user-selectable) |
| Sample Capacity | 1 position (SLFA-2100) / 8-position automated turntable (SLFA-2800) |
| Operating Temperature | 5–35 °C |
| Relative Humidity | 30–85 % RH |
| Energy Range | 0–10 keV |
| Output Interface | RS-232C |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | 150 VA |
| Dimensions (W×D×H) | 430 × 500 × 230 mm |
| Weight | ~21 kg (SLFA-2100) / ~24 kg (SLFA-2800) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SLFA-60 |
| Detection Target | Total Sulfur |
| Measurement Principle | X-ray Fluorescence (XRF) Spectrometry |
| Detection Range | 0–10 wt% S |
| Detection Limit | 5 ppm |
| Precision | ±5 ppm (at 1.0% S), ±1.6 ppm (at 0% S) |
| Sample Volume | 4–10 mL per analysis |
| Measurement Time | Adjustable from 10 to 600 seconds |
| Sample Capacity | 8-position automated rotary stage |
| Sample Holder | Disposable liquid-specific film-bottom cup |
| Calibration Flexibility | Up to 20 calibration points across 5 stored curves (linear/nonlinear) |
| Environmental Operating Range | 5–35 °C, 30–85% RH |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | 150 VA |
| Interface | RS-232C standard serial port |
| Dimensions | 430 × 500 × 230 mm |
| Weight | ~24 kg |
| Compliance | ASTM D4294, ISO 8754, JIS K2541 & B7995, GB/T 17040–1997, GB/T 17060–1998, SN/T 0509–1995 |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Smart SE |
| Spectral Range | 450–1000 nm |
| Spot Size Options | Multiple Micro-Spot Sizes with Real-Time Visual Observation |
| Incidence Angle | Variable (Motorized Multi-Angle Capability) |
| Measurement Speed | Full-Spectrum Acquisition in <1 Second |
| Single-Measurement Time | <2 s (Typical, Including Stage Positioning) |
| Sample Stage | Motorized XYZ Translation (200 mm × 200 mm Travel, Z-Travel >35 mm) |
| Detector | CCD-Based Spectral Analyzer |
| Modulation Technology | Liquid Crystal Variable Retarder (LCVR), No Moving Parts in Optical Path |
| Configuration Flexibility | Supports Both In-Line Process Integration and Stand-Alone Lab Use |
| Compliance | Designed for ISO/IEC 17025-Compatible Metrology Environments |
| Software | HORIBA DeltaPsi² Platform with Audit Trail, User Access Control, and Exportable Raw Data (CSV, XML, HDF5) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Smart SE |
| Spectral Range | 450–1000 nm |
| Detector | CCD |
| Spot Visualization | Patented real-time surface imaging |
| Spot Selection | Motorized multi-size micro-spot (e.g., 30 µm, 100 µm, 300 µm) |
| Sample Stage | Motorized XYZ stage (200 mm × 200 mm travel, Z-axis range >35 mm) |
| Modulation | Liquid Crystal Variable Retarder (LCVR), no moving parts in optical path |
| Measurement Mode | Variable-angle spectroscopic ellipsometry |
| Output | Full-spectrum Ψ(λ) and Δ(λ) in <1 s per angle |
| Configuration | Supports both offline lab-based and inline process-integrated deployment |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Smart SE |
| Measurement Speed | 5 s (typical), down to 1 s (max) |
| Wavelength Range | 450–1000 nm |
| Spot Sizes | 7 selectable configurations (e.g., 75 µm × 150 µm to 500 µm × 500 µm) |
| Software | DeltaPsi² v5.x (Windows-based) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | SPRi-EzPlex |
| Sample Volume | 200 µL (standard), optional 100/250/500 µL |
| Temperature Control Range | 15–40 °C, Accuracy: ±0.1 °C, Stability: ±0.01 °C |
| Detection Limit | 5 pg/mm² |
| Minimum Analyte MW | >240 Da |
| Sample Concentration Range | 150 ng/mL (for 100–1000 kDa) to 5 µg/mL (for 4–20 kDa) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | SPRi-OpenPlex |
| Sample Volume | 200 µL (standard), optional 100/250/500 µL |
| Detection Limit | 10 pg/mm² |
| Minimum Analyte MW | >240 Da |
| Sample Concentration Range | 300 ng/mL (for 100–1000 kDa) to 10 µg/mL (for 4–20 kDa) |
| Temperature Control | Not specified in input |
| Compliance | CE-marked, compatible with GLP/GMP workflows requiring audit trails and instrument qualification |