| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-555 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption at ~3.4 µm |
| Measurement Ranges | 0–200 mg/L, 0–1000 mg/kg, 0–1 Abs |
| Accuracy | ±1% of reading (for mg/L range) |
| Resolution | 0.1 mg/L (0–99.9 mg/L), 1 mg/L (100–200 mg/L), 0.01 Abs (0–1 Abs) |
| Repeatability | ±0.4 mg/L ±1 digit (0–9.9 mg/L), ±2.0 mg/L ±1 digit (10.0–99.9 mg/L), ±4 mg/L ±1 digit (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Detector | Thermopile sensor |
| Display | Backlit LCD with timestamping |
| Interface | RS-232C port, parallel printer port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Standard Accessories | Quartz cuvette with lid, power cord, heavy oil standard (B-grade), 2 A fuse, 10 mL syringe, 25 µL microsyringe |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-555 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Measurement Range | 0–200 mg/L (water), 0–1000 mg/kg (soil), 0–1 Abs |
| Detection Limit | 0.2 mg/L |
| Accuracy | ±1% of reading or ±1 digit (whichever is greater) |
| Resolution | 0.1 mg/L |
| Measurement Frequency | 1 test per 2 minutes |
| Solvent | H-997 (non-absorbing at ~3.4 µm) |
| Sample Cell | 20 mm quartz cuvette |
| Output Interface | RS-232C, parallel printer port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Weight | Approx. 6.5 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-555 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption at ~3.4 µm |
| Measurement Ranges | 0–200 mg/L, 0–1000 mg/kg, 0–1 Abs |
| Detection Limit | 0.1 mg/L |
| Accuracy | ±1% of reading (for aqueous phase) |
| Resolution | 0.1 mg/L (0–99.9 mg/L range) |
| Repeatability | ±0.4 mg/L ±1 digit (0–9.9 mg/L), ±2.0 mg/L ±1 digit (10.0–99.9 mg/L), ±4 mg/L ±1 digit (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Detector | Thermoelectric (Thermopile) Sensor |
| Display | Backlit LCD with timestamping |
| Data Interface | RS-232C port and parallel printer port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Standard Accessories | Quartz cuvette with lid, power cord, heavy oil standard (B-grade), 2 A fuse, 10 mL syringe, 25 µL syringe |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-555 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption Spectrophotometry |
| Extraction Solvent | H-997 |
| Measurement Range | 0–200 mg/L (water), 0–1000 mg/kg (soil), 0–1 Abs |
| Repeatability | ±0.4 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Detection Limit | 0.1 ppm |
| Optical Path | Quartz Cuvette (200 mm path length) |
| Display | Backlit LCD with timestamping |
| Interface | RS-232C, Parallel Printer Port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Standard Accessories | Covered quartz cuvette, power cord, heavy oil standard (B-grade), 2 A fuse, 10 mL and 25 µL syringes |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-555H |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption Spectrophotometry |
| Measurement Range | 0–200 mg/L, 0–1000 mg/kg, 0–1 Abs |
| Detection Limit | <0.3 mg/L |
| Accuracy | ±1% of reading (mg/L) |
| Resolution | 0.1 mg/L (for 0–99.9 mg/L range) |
| Measurement Frequency | 1 measurement per 5 minutes (0.2 min⁻¹) |
| Optical Path | 20 mm quartz cuvette |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Detector | Thermoelectric sensor |
| Data Interface | RS-232C serial port & parallel printer port |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-555H |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption Spectrophotometry |
| Measurement Range | 0–200 mg/L |
| Accuracy | ±1% of reading (mg/L) |
| Resolution | 0.1 mg/L (0–99.9 mg/L) |
| Detection Wavelength | ~3.4 µm |
| Solvent Compatibility | H-519 (non-absorbing at 3.4 µm) |
| Repeatability | ±0.4 mg/L ±1 digit (0–9.9 mg/L) |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Detector Type | Thermopile Sensor |
| Display | Backlit LCD with timestamping |
| Data Interface | RS-232C serial port & parallel printer port |
| Standard Accessories | Quartz cuvette (20 mm pathlength, with lid), power cord, heavy oil standard (B-grade), 2 A fuse, 10 mL syringe, 25 µL microsyringe |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | OEM Customizable Spectrometer |
| Price | Upon Request |
| Spectral Range | 190–2100 nm |
| Optical Resolution | 10–1 nm (FWHM, configurable per design) |
| Focal Length | 20–140 mm |
| Detector Options | Single-channel PMT, Linear/2D CCD, CMOS, InGaAs, NMOS, PDA arrays |
| Optical Design | Monolithic Czerny–Turner or Crossed-beam configuration with Aberration-Corrected (Type-4) holographic grating |
| Compliance | Designed for integration into ISO/IEC 17025-accredited analytical systems, compatible with FDA 21 CFR Part 11–ready software environments |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OM-71 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measurement Parameter | Dissolved Oxygen (DO) |
| Detection Principle | Membrane-Type Galvanic Cell |
| Temperature Compensation Range | 0–40 °C |
| Salinity Compensation Range | 0–40 ppt |
| Atmospheric Pressure Compensation | Yes |
| DO Range | 0.00–20.00 mg/L |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.1 mg/L ±1 digit |
| Saturation DO Range | 0.0–200.0 % |
| Oxygen Concentration Range | 0.0–50.0 % |
| Display | Backlit Monochrome LCD |
| Data Storage | 1,000 measurements with timestamp, ID, and temperature |
| Environmental Rating | IP67 |
| Operating Temperature | 0–45 °C |
| Power | 2× AAA alkaline or Ni-MH batteries (≈500 h life) |
| Dimensions | 67 × 28 × 170 mm (max thickness 80 mm) |
| Weight | 270 g (body only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OM-71 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measured Parameter | Dissolved Oxygen (DO) |
| Measurement Principle | Membrane-Type Galvanic Cell |
| DO Range | 0.00–20.00 mg/L |
| Saturation Range | 0.0–200.0 % |
| Oxygen Concentration Range | 0.0–50.0 % |
| Resolution | 0.01 mg/L (DO), 0.1 % (saturation & O₂ conc.) |
| Accuracy | ±0.1 mg/L ±1 digit (DO), ±0.1 % (saturation & O₂ conc.) |
| Temperature Compensation | 0–40 °C |
| Salinity Compensation | 0–40 ppt |
| Atmospheric Pressure Compensation | Yes |
| Temperature Range (Measurement) | 0.0–100.0 °C (display), –30 to 130 °C (sensor limit) |
| Temp. Accuracy | ±0.1 °C ±1 digit |
| Display | Backlit monochrome LCD |
| Data Storage | 1,000 readings with timestamp, ID, and temperature |
| Protection Rating | IP67 |
| Operating Environment | 0–45 °C, RH ≤80 % non-condensing |
| Power | 2 × AAA alkaline or Ni-MH batteries |
| Dimensions | 67 × 28 × 170 mm (W × D × H, max thickness 80 mm) |
| Weight | ~270 g (without batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OM-71 |
| Instrument Type | Portable |
| Measurement Principle | Galvanic Cell (Electrochemical Membrane Probe) |
| Measurement Range (DO) | 0.00–20.00 mg/L |
| Accuracy (DO) | ±0.01 mg/L |
| Repeatability | ±0.05% |
| Detection Limit | ±2 ppb |
| Temperature Range (Measurement) | −30 °C to 130 °C (Display: 0.0–100.0 °C) |
| Temperature Accuracy | ±0.1 °C ±1 digit |
| Saturation DO Range | 0.0–200.0 % |
| O₂ Concentration Range | 0.0–50.0 % |
| Salt Compensation | 0–40 ppt |
| Atmospheric Pressure Compensation | Yes |
| Display | Backlit Monochrome LCD |
| Data Storage | 1,000 sets with timestamp & ID |
| Communication | USB/RS-232 (PC connectivity, GLP/GMP-compliant data export) |
| Protection Rating | IP67 |
| Operating Environment | 0–45 °C, 0–80% RH (non-condensing) |
| Power | 2 × AAA alkaline or Ni-MH batteries (~500 h battery life) |
| Dimensions (W×D×H) | 67 × 28 × 170 mm (max. thickness 80 mm) |
| Weight (without batteries) | ~270 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OM-71 |
| Instrument Type | Portable |
| Parameter Type | Single-parameter (Dissolved Oxygen) |
| Measurement Range | 0.00–19.99 mg/L |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.01 mg/L |
| Measurement Principle | Membrane-based Galvanic Cell |
| Temperature Compensation | 0–40 °C |
| Salinity Compensation | 0–40 ppt |
| Atmospheric Pressure Compensation | Yes |
| Saturation DO Range | 0.0–200.0 % |
| Oxygen Concentration Range | 0.0–50.0 % |
| Display | Backlit Monochrome LCD |
| Data Storage | 1000 records with timestamp, ID, and temperature |
| Environmental Rating | IP67 |
| Operating Temperature | 0–45 °C |
| Power | 2× AAA alkaline or Ni-MH batteries (≈500 h battery life) |
| Dimensions | 67 × 28 × 170 mm (max thickness 80 mm) |
| Weight | 270 g (body only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OM-71 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measured Parameter | Dissolved Oxygen (DO) |
| Measurement Principle | Membrane-Type Galvanic Cell |
| DO Range | 0.00–20.00 mg/L |
| Saturation Range | 0.0–200.0 % |
| Oxygen Concentration Range | 0.0–50.0 % |
| Resolution | 0.01 mg/L / 0.1 % |
| Temperature Compensation | 0–40 °C |
| Salinity Compensation | 0–40 ppt |
| Atmospheric Pressure Compensation | Yes |
| Accuracy | ±0.1 mg/L ±1 digit (DO), ±0.1 % (saturation), ±0.1 °C (temperature) |
| Repeatability | ±0.1 mg/L ±1 digit |
| Operating Environment | 0–45 °C, RH 0–80 % (non-condensing) |
| Protection Rating | IP67 |
| Display | Backlit monochrome LCD |
| Data Storage | 1,000 measurements with timestamp, ID, and temperature |
| Interface | USB for PC connectivity |
| Power | 2× AAA alkaline or Ni-MH batteries (≈500 h operation) |
| Dimensions | 67 × 28 × 170 mm (W×D×H, thickest point) |
| Weight | ≈270 g (without batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OPSA-150 |
| Instrument Type | Online Analyzer |
| Measurement Principle | UV-Vis Absorption Spectrophotometry |
| Wavelengths | UV: 254 nm, VIS: 546 nm |
| Measurement Range | 0–10 m⁻¹ SAC (0–0.1 Abs to 0–5.0 Abs equivalent) |
| Repeatability | ±2.0% F.S. |
| Resolution | 0.01 m⁻¹ SAC (0.0001 Abs) |
| Data Logging | Internal storage for 1 year (hourly intervals), CF card export supported |
| Cleaning Method | Continuous wiper-based optical cell cleaning |
| Flow Interruption Detection | Standard flow switch input |
| Display | Touchscreen HMI with guided setup and dual-parameter display (COD + turbidity conversion) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OPSA-150 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Dual-Wavelength UV/VIS Absorption Spectrophotometry |
| Measurement Wavelengths | UV: 253.7 nm, VIS: 546.1 nm |
| Measurement Range | 0–10 m⁻¹ SAC to 0–500 m⁻¹ SAC (0–0.1 Abs to 0–5.0 Abs) |
| Accuracy | ±2.0% F.S. |
| Repeatability | ±2.0% F.S. |
| Detection Limit | 0.01 m⁻¹ SAC |
| Resolution | 0.01 m⁻¹ SAC (0.0001 Abs) |
| Zero Drift Compensation | Rotating Cell-Length Adjustment System |
| Cleaning Method | Continuous Wiper-Based Optical Path Cleaning |
| Data Storage | Internal memory (1-year hourly data) + CF card export |
| Output | 3-channel isolated 4–20 mA analog outputs |
| Communication | RS-232C (19200 bps) |
| Sample Flow Rate | 2–20 L/min |
| Operating Temperature | 2–40 °C |
| Power Supply | AC 100–230 V ±10%, 50/60 Hz |
| Enclosure | Indoor-rated, IP54-equivalent housing |
| Weight | ~100 kg |
| Dimensions | 460 W × 380 D × 1600 H mm |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PA-1000 |
| Detection Principle | Scintillation Crystal (NaI(Tl)) |
| Radiation Type | Gamma (γ) Rays |
| Sensitivity | ≥1000 cpm at 1 µSv/h (Cs-137 reference) |
| Relative Error | ±10% |
| Energy Range | >150 keV |
| Energy Response | 0.5–3.0 × (150 keV–1250 keV, relative to Cs-137 @ 662 keV) |
| Measurement Range | 0.001–9.999 µSv/h |
| Display | 4-digit LCD, µSv/h unit |
| Averaging Interval | 60-second moving average |
| Update Interval | 10 seconds |
| Dimensions | 68(W) × 28(D) × 121(H) mm |
| Mass | ≤175 g |
| Power | Two AA alkaline batteries |
| Housing Material | Bio-based polymer (plant-derived plastic) |
| Audio Alert | Configurable on/off for dose rate change notification |
| Compliance | Designed for educational and environmental screening use |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PA-1000 |
| Instrument Type | Gamma Spectrometer |
| Measurement Range | 0.001–9.999 µSv/h |
| Sampling Time | 60 s |
| Accuracy | ±10% |
| Dimensions | 68 × 28 × 121 mm (W×D×H) |
| Weight | 175 g (without batteries) |
| IP Rating | IP40 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Partica CENTRIFUGE CN-300 |
| Measurement Principle | Centrifugal Sedimentation |
| Measured Range | 10 nm – 40 µm |
| Maximum Centrifugal Force | 30,000 × g |
| Temperature Control | Integrated Peltier Cooling for Sample Cell and Rotor |
| Measurement Modes | Density Gradient Mode & Homogeneous Mode |
| Sample Volume | As low as 2 µL (undiluted) or 10 µL (diluted) |
| Compliance | IEC 61010-1:2010 / IEC 61010-2-020:2016 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | PD-Xpadion |
| Pricing | Available Upon Request |
| Particle Detection Sensitivity | 0.5 µm (standard), 0.35 µm (optional), 0.1 µm (with RP-1 integration) |
| Throughput | 12 min per mask (front + back side scan) |
| Mask Size Compatibility | 5-inch to 9-inch |
| Uptime | ≥98% |
| MTBF | 1500 hours |
| Scan Surfaces | Glass substrate, thin-film layer, and patterned side (3-sided inspection) |
| Scan Time per Side | ≤4 minutes |
| Automation Interface | OHT, EFEM, SECS/GEM compliant |
| Optional Modules | Raman-based particle characterization, film thickness & uniformity mapping, film health monitoring, integrated particle removal (RP-1 system) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-250 |
| Detection Principles | Chemiluminescence (NOₓ), NDIR (SO₂, CO, CO₂), Zirconia or Galvanic Cell (O₂) |
| Gas Channels | NOₓ, SO₂, CO, CO₂, O₂ (simultaneous 5-gas analysis) |
| Measurement Ranges | NOₓ (0–5000 ppm, 7 ranges), SO₂ (0–1000 ppm, 3 ranges), CO (0–5 vol%, 8 ranges), CO₂ (0–20 vol%, 3 ranges), O₂ (0–25 vol%, 3 ranges) |
| Portability | Integrated handle, stackable design, built-in sampling system (filter, demister, pump, thermoelectric cooler, NO-to-NO₂ converter) |
| Compliance | Designed for ASTM D6522, ISO 9096, EN 14792, EPA Method 7E/6C/10, and applicable GLP/GMP field-use requirements |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-300 |
| Detection Principles | Pulsed Flow Modulation Chemiluminescence (NOₓ), Pulsed Flow Modulation NDIR (SO₂, CO, CH₄), Broadband NDIR (CO₂), Galvanic Cell (O₂) |
| Measured Gases | SO₂, NOₓ, CO, CO₂, O₂, CH₄ (optional) |
| Range Options | NOₓ: 0–25 to 0–2500 ppm (7 ranges) |
| SO₂ | 0–200 to 0–3000 ppm (4 ranges) |
| CO | 0–200 to 0–5000 ppm (5 ranges) |
| CO₂ | 0–10 to 0–30 vol% |
| O₂ | 0–5 to 0–25 vol% |
| CH₄ | 0–2000/5000 ppm |
| Accuracy | ±1.0% F.S. (SO₂: ±2.0% F.S./day) |
| Repeatability | ±1.0% F.S. |
| Linearity | ±2.0% F.S. |
| T₉₀ Response Time | ≤45 s (SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min (±2.0% F.S. stabilized within 2 h) |
| Display | Color TFT LCD touchscreen with real-time trend plotting |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Certifications | TÜV (EU), MCERTS (UK), GOST-R (Russia), ETV (US), CNAS/CMA (China), KOLAS (Korea), JIS/MLIT (Japan) |
| Compliance | Designed for EN 15267, EN 14181, ISO 12039, ISO 10849, US EPA Methods 6C, 7E, 10, and applicable CEMS QA/QC protocols |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-300 Series |
| Detection Principles | Pulsed Flow Modulation Chemiluminescence (NOₓ), Pulsed Flow Modulation NDIR (SO₂, CO, CH₄), Broadband NDIR (CO₂), Galvanic Cell (O₂) |
| Measured Gases | SO₂, NOₓ, CO, CO₂, O₂, CH₄ (optional) |
| Range | NOₓ: 0–2500 ppm (7 ranges), SO₂: 0–3000 ppm (4 ranges), CO: 0–5000 ppm (5 ranges), CO₂: 0–30 vol% (3 ranges), O₂: 0–25 vol% (3 ranges), CH₄: 0–5000 ppm |
| Accuracy | ±1.0% F.S. (±2.0% F.S./day for SO₂) |
| Repeatability | ±1.0% F.S. |
| Linearity | ±2.0% F.S. |
| T90 Response Time | ≤45 s (SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min (±2.0% F.S. stabilized within 2 h) |
| Display | Color TFT LCD with touch interface, real-time trend graphs & step-by-step operation guidance |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Certifications | TÜV (EU), MCERTS (UK), GOST-R (Russia), ETV (US), China Metrology Certification (CMC), Korea Metrology Certification, Japan JIS/JCSS |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-300 Series |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ≤2.0% F.S. |
| Repeatability | ±1.0% F.S. |
| Response Time (T90) | ≤45 s (SO₂: ≤180 s) |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Sample Flow Rate | ~0.5 L/min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Weight | ~14 kg |
| Dimensions | 226(W) × 265(H) × 510(D) mm |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Data Storage | SD card |
| Output Interfaces | 4–20 mA DC, Ethernet |
| Certified Standards | TÜV (EU), MCERTS (UK), GOST (Russia), ETV (US), China Metrology Certification, Korea KOLAS, Japan JIS/JCSS |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PG-300 Series |
| Product Type | Portable |
| Response Time | ≤45 s (SO₂: ≤180 s) |
| Repeatability | SO₂, NOₓ, CO, CO₂, O₂, CH₄ |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 Series |
| Instrument Type | Portable Flue Gas Analyzer |
| Repeatability | ±1.0% FS |
| Response Time (T90) | ≤45 s (except SO₂: ≤180 s) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy | ≤1.0% FS |
| Repeatability | ≤1.0% FS |
| Response Time (T90) | ≤45 s (SO₂ ≤180 s) |
| Stability | ≤2.0% FS/2 h |
| Measured Gases | SO₂, NO, CO, O₂, CO₂ (optional CH₄) |
| Detection Principles | Pulsed Flow Modulation Chemiluminescence (NOₓ), Pulsed Flow Modulation NDIR (SO₂, CO, CH₄), Broadband NDIR (CO₂), Galvanic Cell (O₂) |
| Sample Flow Rate | ~0.5 L/min |
| Display | Color TFT Touchscreen with Real-time Trend Plotting |
| Data Storage | SD Card (user-configurable interval) |
| Output Interfaces | 4–20 mA analog, Ethernet |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy | ±2.0% FS |
| Repeatability | ±1.0% FS |
| Response Time (T90) | ≤45 s for NOₓ, CO, CO₂, O₂ |
| Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Warm-up Time | 30 min |
| Sample Flow Rate | ~0.5 L/min |
| Display | Color TFT LCD with Touch Interface |
| Data Storage | Removable SD Card |
| Output | 4–20 mA DC analog output, Ethernet interface |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Dimensions | 226 × 265 × 510 mm (W × H × D) |
| Weight | ~14 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Target Gases | NOx, SO₂, CO, CO₂, O₂ |
| Measurement Ranges | NOx: 0–25/50/100/250/500/1000/2500 ppm (7 ranges), SO₂: 0–200/500/1000/3000 ppm (4 ranges), CO: 0–200/500/1000/2000/5000 ppm (5 ranges), CO₂: 0–10/20/30 vol%, O₂: 0–5/10/25 vol% |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Compliance | MCERTS (UK), TÜV (EU), GOST (Russia), EPA ETV (US), CNAS/CMA (China), KOLAS (Korea), JIS (Japan) |
| Data Storage | SD card (user-configurable interval) |
| Output | 4–20 mA analog, Ethernet |
| Preheat Time | 30 min (±2.0% F.S. stability within 2 h) |
| Detection Principles | Pulsed Flow Modulation Chemiluminescence (NOx), Pulsed Flow Modulation NDIR (SO₂, CO, CH₄), Broadband NDIR (CO₂), Galvanic Cell (O₂) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measurable Gases | NOx, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5/10/25 vol% (CO₂, O₂) |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (all gases except SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Dimensions | 226(W) × 265(H) × 510(D) mm |
| Weight | ~14 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 Series |
| Instrument Type | Portable |
| Detection Targets | NOₓ, SO₂, CO, CO₂, O₂ (optional CH₄) |
| Measurement Ranges | NOₓ: 0–25/50/100/250/500/1000/2500 ppm (7 ranges) |
| SO₂ | 0–200/500/1000/3000 ppm (4 ranges) |
| CO | 0–200/500/1000/2000/5000 ppm (5 ranges) |
| CO₂ | 0–10/20/30 vol% |
| O₂ | 0–5/10/25 vol% |
| CH₄ | 0–2000/5000 ppm |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Weight | ~14 kg |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA DC, Ethernet |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Target Gases | NOx, SO₂, CO, CO₂, O₂ |
| Measurement Principle | Pulsed Flow Modulation Chemiluminescence (NOx), Pulsed Flow Modulation NDIR (SO₂, CO, CH₄), Broadband NDIR (CO₂), Galvanic Cell (O₂) |
| Range Options | NOx: 0–2500 ppm (7 ranges), SO₂: 0–3000 ppm (4 ranges), CO: 0–5000 ppm (5 ranges), CO₂: 0–30 vol% (3 ranges), O₂: 0–25 vol% (3 ranges) |
| Repeatability | ±1.0% FS |
| Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Linearity | ±2.0% FS |
| Response Time (T90) | ≤45 s (SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA, Ethernet |
| Certifications | TÜV (EU), MCERTS (UK), GOST-R (Russia), ETV (US), CNAS/CMA (China), KOLAS (Korea), JIS/MIAC (Japan) |