| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AMI 400TPx |
| Pricing | Upon Request |
| Core Functionality | Fully Automated TPD, TPR, TPO, TPSR, Pulse Chemisorption, Single-Point BET, Optional MS/GC/FID/FTIR Coupling |
| Gas Compatibility | Inert, Reducing (H₂), Oxidizing (O₂, NO, CO₂), Corrosive (SO₂, H₂S) |
| Control Architecture | Integrated Pneumatic Valve Manifold with Real-Time Flow Path Visualization |
| Software | Proprietary ChemiSoft™ with Live System Status Dashboard, Parameter Logging, and Audit-Trail-Ready Data Export |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer | JWGB Instrument Co., Ltd. |
| Type | Adsorption Breakthrough Experimental Setup |
| Reactor Type | Tubular Fixed-Bed Reactor |
| Volume Class | Small-Scale |
| Operating Pressure | High-Pressure |
| Customization | OEM/ODM Available |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer | JWGB Instrument Co., Ltd. |
| Type | Custom-Built Benchtop Microreactor System |
| Reactor Configuration | Tubular |
| Operating Pressure | High-Pressure |
| Volume Class | Small-Scale |
| Compliance | Designed for ASTM D3663, ISO 15901-2, and IUPAC physisorption/chemisorption methodology |
| Brand | JWGB |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DSC 600 |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter |
| Temperature Range | −150 °C to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–200 °C/min |
| Temperature Precision | ±0.1 °C |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Product Type | Domestic |
| Model | DX Graphite-Specific Specific Surface Area Analyzer (28 Samples per Hour) |
| Instrument Category | Specific Surface Area Analyzer |
| Principle | Dynamic Flow Method (Gas Chromatography-Based) |
| Number of Analysis Stations | 4 |
| Measurement Range | 0.01 m²/g to unlimited upper limit |
| Operating Pressure | Ambient pressure |
| Theoretical Basis | Dynamic Chromatographic Method with Thermal Conductivity Detection |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | DX Series Dedicated Specific Surface Area Analyzer for Cathode Materials (28 Samples per Hour) |
| Instrument Type | Specific Surface Area Analyzer |
| Operating Principle | Dynamic Flow Method (Carrier Gas Chromatography) |
| Number of Analysis Stations | 4 |
| Measurable Surface Area Range | 0.01 m²/g to unlimited upper limit |
| Operating Pressure | Ambient Pressure |
| Theoretical Basis | Dynamic Chromatographic Adsorption Theory |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dynamic Specific Surface Area Analyzer |
| Model | JWGB DX Series (28 Samples per Hour) |
| Analysis Stations | 4 |
| Measurement Principle | Dynamic Chromatographic Method (Flow Method) |
| Pressure Range | Atmospheric Pressure |
| Theoretical Basis | Direct Comparison Method & BET Theory |
| Specific Surface Area Range | 0.01 m²/g to Unlimited |
| Operating Condition | Liquid Nitrogen Temperature (−196 °C), N₂/He Carrier Gas Mixture |
| Detection System | High-Precision Thermal Conductivity Detector (TCD) |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | DX Series Metal Powder-Specific Specific Surface Area Analyzer (28 Samples per Hour) |
| Instrument Type | Specific Surface Area Analyzer |
| Operating Principle | Dynamic Flow Method (Gas Chromatography-Based) |
| Number of Analysis Stations | 4 |
| Measurement Range | 0.01 m²/g to Unlimited |
| Pressure Condition | Ambient Pressure |
| Theoretical Basis | Dynamic Chromatographic Adsorption Theory |
| Calibration Standard | Direct Comparison Method and BET Theory (for optional extended analysis) |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Product Type | Domestic |
| Model | DX400 Hard Carbon Anode-Specific Specific Surface Area Analyzer (28 Samples per Hour) |
| Instrument Category | Specific Surface Area Analyzer |
| Operating Principle | Dynamic Flow Method (Gas Chromatography-Based) |
| Number of Analysis Stations | 4 |
| Measurement Range | 0.01 m²/g to unlimited upper limit |
| Pressure Condition | Ambient Pressure |
| Theoretical Basis | Dynamic Chromatographic Adsorption Theory |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Chemisorption Analyzer |
| Model | HX-100 |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Heating Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Ramp Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Core Functions | TPR, TPO, TPD, TPSR, Pulse Chemisorption, Pulse Calibration, Dynamic BET Surface Area |
| Detector | High-Stability 4-Filament TCD (Re-W alloy, 200 °C heated) |
| Sample Tube | Quartz U-tube or bubble tube (0.1–1 g capacity) |
| Gas Flow Control | 2–100 mL/min |
| Valve & Tubing | Heated 1/16″ 316 stainless steel lines |
| Dimensions | 43 cm (W) × 64 cm (H) × 62 cm (D) |
| Optional Accessories | Cryogenic trap (–100 °C), Mass Spectrometer (MS) interface, GC integration module |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HX-100 Basic Chemisorption Analyzer |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Heating Temperature Range | Ambient to 1200°C |
| Isothermal Stability | ±0.01°C |
| Ramp Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Functions | TPR, TPO, TPD, TPSR, Pulse Chemisorption, Pulse Calibration, Dynamic BET Surface Area |
| Sample Capacity | 0.1–1 g |
| Analysis Stations | 1 |
| Cooling Method | Forced-air rapid cool-down |
| Detection System | High-stability 4-filament TCD (Re-W wire, 200°C heated) |
| Gas Flow Control | 2–100 mL/min |
| Sample Tube Options | Quartz U-tube or bubble tube |
| Tubing Material | 316 stainless steel, 1/16″ OD |
| System Dead Volume | Minimized via low-volume valves and heated manifold |
| Cold Trap | Integrated desiccant trap downstream of sample tube |
| Quantitative Loop | Precision-calibrated pulse injection port |
| Low-Temp Option | –100°C to 1200°C (with cryo-cooler) |
| Dimensions | 43 × 64 × 62 cm (W × H × D) |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| X-ray Source | Sealed Mo-target Tube |
| Maximum Power | 1600 W |
| Angular Accuracy | ±0.01° |
| Angular Resolution | 0.1° |
| Goniometer Geometry | Vertical θ–2θ |
| Goniometer Radius | 144 mm |
| Angular Range | 0°–150° |
| Detector | Photon-counting 2D Array Detector |
| Sample Stage | Temperature-Controlled Pouch-Cell Holder (−30 °C to 300 °C) |
| Dimensions | 900 mm × 680 mm × 550 mm |
| Weight | 100 kg |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Method |
| Analysis Stations | 12 (configurable up to 3 cascaded units) |
| Pore Diameter Range | 0.35 nm – 500 nm |
| Relative Pressure Range | 1×10⁻⁸ – 0.998 |
| Repeatability | ≤0.02 nm (most probable pore diameter, standard sample) |
| Ambient Temperature | 15°C – 40°C |
| Vacuum System | Imported mechanical vacuum pump + imported turbo-molecular pump (ultimate vacuum: 1×10⁻⁸ Pa) |
| BET Surface Area Detection Limit | ≥0.0005 m²/g (RSD ≤1.0%, certified reference material) |
| Total Pore Volume Detection Limit | ≥0.0001 cm³/g |
| Degassing Temperature | Ambient – 400°C (customizable to higher) |
| Valve Box Temperature Control | Up to 45°C ±0.5°C (uniformity <1°C across chamber) |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | JW-BK200C Catalyst-Specific Micropore Size Analyzer |
| Pricing | Upon Request |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method (Gas Adsorption) |
| Number of Analysis Stations | 2 |
| Specific Surface Area Range | Down to 0.0001 m²/g |
| Relative Pressure Range | p/p₀ down to 10⁻⁸ |
| Theoretical Framework | BET Multilayer Adsorption Theory, BJH Mesopore Analysis, HK/SF/NLDFT Micropore Modeling |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Method (Low-Temperature Gas Adsorption) |
| Analysis Stations | 2 Independent Micro/Meso-Pore Stations |
| BET Surface Area Range | Down to 0.0001 m²/g |
| Relative Pressure Range | p/p₀ = 1×10⁻⁸ to 0.998 |
| Theoretical Models | BET, Langmuir, BJH, t-plot, αs-plot, DR, MP, HK, SF, NLDFT |
| Pressure Sensors | Triple-range (1000 torr / 10 torr / 1 torr), accuracy ≤ ±0.15% of reading |
| Ultimate Vacuum | ≤1×10⁻⁶ Pa (analysis station) |
| Micropore Resolution Limit | 0.35 nm (N₂ at 77 K) |
| Degassing Temperature | RT–400 °C, ±1 °C control |
| Data Acquisition | Ethernet-based, Windows 7/10 (32/64-bit) compatible |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JW-BK222 Basic Specific Surface Area and Pore Size Analyzer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Gas Adsorption (Static Capacity Method) |
| Number of Analysis Stations | 2 independent parallel stations with simultaneous in-situ degassing |
| Specific Surface Area Range | ≥0.0005 m²/g |
| Relative Pressure Range (p/p₀) | 1×10⁻⁶ to 0.998 |
| Adsorption Theory | Gas adsorption-based static volumetric method |
| Compatible Adsorbates | N₂, Ar, Kr, H₂, O₂, CO₂, CO, NH₃, CH₄ (non-corrosive gases only) |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | JW-BK222 Carbon Black & Silica Fumed Specific Surface Area Analyzer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Gas Adsorption Method |
| Number of Analysis Stations | 2 independent parallel stations with in-situ degassing capability |
| Specific Surface Area Range | Down to 0.0005 m²/g |
| Relative Pressure Range (p/p₀) | 1×10⁻⁶ to 0.998 |
| Theoretical Basis | Gas Adsorption Isotherm Analysis via Static Volumetric Technique |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JW-BK222 Silica Fume-Specific BET Specific Surface Area Analyzer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Gas Adsorption Method |
| Number of Analysis Stations | 2 Independent Parallel Stations with In-Situ Degassing Capability |
| Specific Surface Area Range | Down to 0.0005 m²/g |
| Relative Pressure Range (p/p₀) | 1×10⁻⁶ to 0.998 |
| Theoretical Basis | Gas Adsorption Isotherm Analysis via Static Volumetric Technique |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Model | JW-BK300C Research-Grade Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 3 |
| Specific Surface Area Range | Down to 0.0001 m²/g |
| Relative Pressure Range | p/p₀ down to 10⁻⁸ (N₂ at 77 K) |
| Theoretical Models | BET Multilayer Adsorption, BJH Desorption for Mesopores, HK/SF for Micropores, NLDFT Non-Local Density Functional Theory |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | JW-BK400 Ceramic-Specific Surface Area Analyzer (Static Volumetric Method) |
| Instrument Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 4 |
| Measurement Accuracy | ≤ ±1.0% (specific surface area) |
| Pressure Range | P/P₀ = 10⁻⁴ to 0.998 |
| Theoretical Basis | Static Volumetric Method with Cryogenic Nitrogen Adsorption (or other inert adsorbates) |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Model | JW-BK400 Quad-Station Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption Method |
| Number of Analysis Stations | 4 independent stations |
| Specific Surface Area Range | 0.005 m²/g to unlimited |
| Relative Pressure Range | P/P₀ = 10⁻⁴ to 0.99 |
| Theoretical Basis | Gas Adsorption Theory, Static Volumetric Method |
| Repeatability | ≤ ±1.5% for surface area |
| Average Analysis Time per Sample | ~10 min (BET single-point) |
| Degassing Temperature Range | Ambient to 400 °C (±1 °C accuracy) |
| Pressure Transducers | 4 imported sensors, accuracy ≤ ±0.15% FS |
| Vacuum System | Stainless-steel multi-port parallel manifold with micro-adjustable vacuum speed control (2–200 mL/s) |
| Ultimate Vacuum | 10⁻² Pa |
| Data Acquisition | Ethernet-based, Windows 7/XP (32/64-bit) compatible |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | JW-DX Dynamic Specific Surface Area Analyzer |
| Instrument Type | Specific Surface Area Analyzer |
| Measurement Principle | Dynamic Flow Method (Gas Chromatographic Adsorption) |
| Number of Analysis Stations | 4 |
| Specific Surface Area Range | 0.01 m²/g to unlimited |
| Relative Pressure Range (p/p₀) | 0.05–0.35 |
| Theoretical Basis | BET Multilayer Adsorption Theory |
| Carrier Gases | High-Purity N₂ (99.999%) + He (99.999%) Mixture |
| Repeatability | ≤ ±1.0% |
| Average Analysis Time per Sample | 5 min |
| Vacuum System Limit | 100 Pa |
| Degassing Temperature Range | Ambient to 400 °C ±1 °C |
| Detection Method | Constant-Temperature Thermal Conductivity Detector (TCD) |
| Data Acquisition | USB-based A/D Converter, Windows 2000/XP Compatible |
| Dimensions (Analyzer) | 610 × 360 × 690 mm |
| Weight | ~30 kg |
| Power Supply | AC 220 V ±20 V, 50/60 Hz, 300 W |
| Optional Degasser | 4-Station, Same Temp/Vacuum Specs, 400 × 300 × 550 mm, ~10 kg |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | JW-DX400 Specific Surface Area Analyzer |
| Instrument Type | Specific Surface Area Analyzer |
| Operating Principle | Dynamic Flow (Carrier Gas) Method |
| Number of Analysis Stations | 4 |
| Measurable Surface Area Range | 0.01 m²/g to unlimited upper limit |
| Operating Pressure | Atmospheric pressure |
| Theoretical Basis | Dynamic Chromatographic Method |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JW-M100A Automated True Density Analyzer |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Solid Materials |
| Density Measurement Range | 0 g/mL to no known upper limit |
| Density Accuracy | ≤ 0.03% |
| Resolution | 0.00001 g/mL |
| Temperature Control Range | 0–50 °C |
| Minimum Sample Mass | 5 g |
| Principle | Gas Displacement (Helium, Nitrogen, or Air) |
| Analysis Stations | 1 |
| Pressure Sensor Accuracy | ±0.04% FS |
| Long-Term Stability | ±0.025% FS |
| Vacuum Source | Integrated Oil-Free Diaphragm Pump |
| Sample Cell Volumes | 10–120 mL (6 standard aluminum cells included) |
| Cycle Time | ≤ 2 minutes per analysis |
| Data Interface | Full-touch LCD panel with USB export |
| Compliance | CE certified |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JW-M100A Foam-Specific True Density and Porosity Analyzer |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Solid Materials (Including Rigid & Flexible Foams) |
| Measurement Principle | Gas Displacement Pycnometry (Helium/Nitrogen/Air) |
| Density Range | 0 g/mL to No Known Upper Limit |
| Density Accuracy | ≤ 0.03% (RSD) |
| Resolution | 0.00001 g/mL |
| Temperature Control Range | 0–50 °C |
| Analysis Station | 1 |
| Vacuum System | Integrated Oil-Free Diaphragm Pump |
| Pressure Sensor | Imported High-Stability Transducer, 0.04% FS Accuracy, Long-Term Drift ≤ 0.025% FS |
| Pressure Regulation | Fully Automated, Max Pressure ≤ Atmospheric |
| Sample Chamber Volume Options | 10–120 mL (6 Standard Aluminum Cells Supplied) |
| Cycle Time | ≤ 2 Minutes per Measurement |
| Data Interface | Full-Touch LCD Console + USB Export |
| Compliance | CE Certified, Meets JJG 99–2006 (Chinese National Metrology Verification Regulation), Supports GLP Audit Trail via Exported Timestamped Logs |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JW-M100A Fracturing Proppant-Specific True Density Analyzer |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Solid Materials |
| Measurement Principle | Gas Displacement (Helium Pycnometry) |
| Density Range | 0 g/mL to no known upper limit |
| Density Accuracy | ≤ 0.03% RSD |
| Resolution | 0.00001 g/mL |
| Temperature Control Range | 0–50 °C |
| Analysis Stations | 1 |
| Sample Chamber Volumes | 10–120 mL (6 standard aluminum cells included) |
| Vacuum System | Integrated oil-free diaphragm pump |
| Pressure Sensor | Imported high-stability sensor, 0.04% FS accuracy, long-term stability ≤ 0.025% FS |
| Pressure Control | Fully automated, peak pressure ≤ atmospheric |
| Data Interface | Built-in full-touch LCD control panel with USB export capability |
| Compliance | CE certified |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JW-M100A True Density Analyzer for Ceramic Proppants and Quartz Sand |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Solid Materials |
| Density Measurement Range | 0 g/mL — No Upper Limit |
| Density Accuracy | ≤ 0.03% (RSD) |
| Resolution | 0.00001 g/mL |
| Temperature Control Range | 0–50 °C |
| Measurement Principle | Gas Displacement (Helium/Nitrogen/Air) |
| Analysis Stations | 1 |
| Vacuum System | Integrated Oil-Free Diaphragm Pump |
| Pressure Sensor | Imported High-Stability Sensor, ±0.04% FS Accuracy, Long-Term Drift ≤ 0.025% FS |
| Thermal Management | Integrated Precision Isothermal Module for Sample & Reference Chambers |
| Sample Chamber Volume Options | 10–120 mL (6 Standard Aluminum Cells Supplied) |
| Data Interface | Full-Touch LCD Console + USB Export |
| Compliance | CE Certified |
| Calibration | Includes Certified Reference Standards |
| Testing Time per Sample | ≤ 2 Minutes |
| Porosity Modes | Open-Cell & Closed-Cell Porosity Calculation |
| Software | Embedded Firmware with Audit-Trail Capable Data Logging (GLP-Compatible) |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JW-M100A True Density Analyzer (Open/Closed Cell Porosity) |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Solid Materials |
| Density Range | 0 g/mL — No Known Upper Limit |
| Density Accuracy | ≤ 0.03% |
| Resolution | 0.00001 g/mL |
| Temperature Control Range | 0–50 °C |
| Measurement Principle | Gas Displacement (Helium/Nitrogen/Air) |
| Analysis Stations | 1 |
| Vacuum System | Integrated Oil-Free Diaphragm Pump |
| Pressure Sensor | Imported High-Stability Sensor, ±0.04% FS Accuracy, Long-Term Drift ≤ 0.025% FS |
| Thermal Management | Integrated Active Temperature Stabilization Module for Sample & Reference Chambers |
| Sample Chamber Volume Options | 10–120 mL (6 Standard Aluminum Cells Supplied) |
| Cycle Time | ≤ 2 Minutes per Measurement |
| Data Interface | Full-Touch LCD Console + USB Export |
| Compliance | CE Certified, CNAS-Validated Calibration Traceability, Meets ISO 12154, ASTM D5550, and USP <699> Requirements for Solid Density Determination |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JW-MIX100 |
| Gas Range | Customizable |
| Mass Flow Controllers (MFCs) | 4 units |
| Column Configuration | Customizable breakthrough columns |
| Maximum Adsorption Pressure | 100 bar |
| Detector | Thermal Conductivity Detector (TCD) |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (PRC) |
| Model | JW-MIX100 |
| Pricing | Available Upon Request |
| Core Method | Zero-Length Column (ZLC) Technique |
| Primary Output Data | Breakthrough Curves, Effective Diffusivity (Dₑ), Adsorption Kinetics, Selectivity Coefficients, Binary/Multicomponent Isotherms |