KEM (Kyoto Electronics Manufacturing)
Filter
Showing 61–81 of 81 results
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MKH-710M |
| Titration Mode | Fully Automated |
| Instrument Type | Dual-Mode Karl Fischer Moisture Analyzer (Volumetric & Coulometric) |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 500 mg H₂O |
| Accuracy | ±0.3% RSD (n=10) |
| Minimum Dispensing Increment | 0.1 µg |
| Repeatability | ±0.3% RSD |
| Burette Control Accuracy | ±0.3% |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 measurement records |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | MKV-710 |
| Pricing | Available Upon Request |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Model | MKV-710B |
| Measurement Resolution | 0.005 mL |
| Water Content Range | 1 ppm to 100% H₂O |
| Titration Accuracy (10 mL burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 |
| Titration Control Precision | 0.015 mL |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MKV-710D |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Resolution | 0.005 mL |
| Moisture Range | 1 ppm – 100% H₂O |
| Accuracy (10 mL Burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 |
| Titration Control Precision | ±0.015 mL |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MKV-710M |
| Titration Method | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 1/20,000 |
| Moisture Content Range | 1 ppm to 100% H₂O |
| Accuracy (10 mL Burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 of burette volume |
| Repeatability | ±0.005 mL |
| Burette Capacity | 10 mL |
| Titration Control Precision | 0.005 mL |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 sample records |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.005 mL |
| Water Content Range | 1 ppm to 100% H₂O |
| Accuracy (10 mL Burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 |
| Repeatability | ±0.005 mL |
| Burette Unit | EBU-710-KF |
| Titration Control Precision | 0.015 mL |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 Sample Records |
| GLP Compliance | Operator Logging, Reagent Tracking, Performance Verification, Time-Stamped Audit Trail |
| Connectivity | RS-232C, USB (Host & Device), SS-BUS (APB) |
| Optional Accessories | ADP-611 Coulometric/KF Oven, Solvent Exchange Unit, Dual Burette Module |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | MKV-710S + ADP-611 |
| Price Range | USD 14,000 – 70,000 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Kyoto Electronics Manufacturing Co., Ltd. |
| Type | Imported Instrument |
| Model | PCD-500 |
| Instrument Category | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Principle | Streaming Potential Detection |
| Electrode Output Range | ±2 V DC |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | ~10 W |
| Dimensions (W×D×H) | 250 × 210 × 400 mm |
| Weight | ~4.5 kg |
| Sample Handling | Stirred beaker-based immersion configuration |
| Piston Actuation | Continuously variable vertical reciprocation |
| Minimum Detectable Charge Concentration | ≥1 × 10⁻⁵ mol/L (dilution required for high-concentration samples) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | PD-11N / PD-11 |
| Measurement Principle | Transient Hot-Wire Method |
| Thermal Conductivity Range | 0.03–12 W/(m·K) |
| Accuracy | ±5% |
| Repeatability | ±3% |
| Operating Temperature Range | −10 to 200 °C |
| Standard Measurement Time | 60 s |
| Sample Dimensions (min.) | 100 × 50 × 20 mm (for bulk solids) |
| Probe Form Factor | Encapsulated box-type sensor |
| Physical Dimensions (L×W×H) | 110 × 50 × 100 mm |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | PD-13N / PD-13 |
| Measurement Principle | Hot Wire Method |
| Dimensions (L×W×H) | 110 × 50 × 100 mm |
| Accuracy | ±5% |
| Thermal Conductivity Range | 0.03–12 W/m·K |
| Repeatability | ±3% |
| Operating Temperature Range | −10 to 200 °C |
| Standard Measurement Time | 60 s |
| Sample Size Requirement | ≥100 × 50 × 20 mm (sheet form) |
| Minimum Thickness for Film Samples | 0.1 mm (for k = 0.1 W/m·K), 5 mm (for k = 5 W/m·K) |
| Compatible With | QTM-710/QTM-700 (PD-13N), QTM-500 (PD-13) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | PD-NO |
| Measurement Principle | Transient Hot Wire (THW) Method |
| Dimensions (L×W×H) | 262 × 276 × 158 mm |
| Accuracy | ±5% |
| Thermal Conductivity Range | 0.0116–0.1 W/m·K |
| Repeatability | ±3% |
| Operating Temperature Range | −100 to +180 °C |
| Standard Measurement Time | 40 s |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | QTM-710 / QTM-700 |
| Measurement Principle | Transient Hot Wire Method |
| Sample Form | Solid (bulk or sheet), including thin films (QTM-710 only) |
| Thermal Conductivity Range | 0.03–12 W/(m·K) |
| Repeatability | ±3% |
| Accuracy | ±5% (vs. certified reference materials at 23 °C) |
| Dimensions (L×W×H) | 262 × 276 × 158 mm |
| Weight | ~4 kg |
| Measurement Time | 60 s per test |
| Display | 5.7-inch color touchscreen |
| Operating Environment | 5–35 °C, <85% RH |
| Power Supply | DC 24 V / AC 100–240 V, 50/60 Hz |
| Interface | 2 × RS-232C, 2 × USB |
| Data Export | CSV via USB flash drive |
| Compliance | ASTM D5470, ISO 22007-2, GB/T 10297-2015, GB/T 5990-2006, GB/T 42919.1-2023, JJF 2221-2025 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | QTM-PA1 |
| Measurement Principle | Transient Hot Wire Method |
| Dimensions (L×W×H) | 262 × 276 × 158 mm |
| Accuracy | ±5% |
| Thermal Conductivity Range | 0.03–12 W/m·K |
| Repeatability | ±3% |
| Operating Temperature Range | −10 to 200 °C |
| Standard Measurement Time | 60 s |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | RA-600 |
| Price Range | USD 7,000–14,000 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | RA-600 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, 5–75°C (optional 5–100°C) |
| Digital Display | Yes |
| Refractive Index Range | 1.3200–1.7000 nD |
| Brix Range | 0.00–100.00% |
| Refractive Index Accuracy | ±0.0001 nD |
| Brix Accuracy | ±0.1% |
| Resolution | 0.0001 nD / 0.1% Brix |
| Light Source | LED at 589.3 nm (sodium D-line equivalent) |
| Prism Material | Sapphire |
| Sample Volume | 0.2 mL |
| Sample Stage Material | SUS316 stainless steel |
| Display | 4.7-inch color backlit LCD with touch interface (Chinese/English/Japanese) |
| Data Storage | 100 methods, 300 results, 20 calibration/verification records |
| Interface | LAN, USB, RS-232C |
| Power | AC 100–240 V, 50/60 Hz, 20 W |
| Dimensions | 191 × 281 × 161 mm |
| Weight | ~5 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Class | Benchtop Refractometer |
| Temperature Control | Peltier-based, 5–75 °C |
| Digital Display | Yes |
| Measurement Range | Refractive Index (nD): 1.32000–1.58000 |
| Brix | 0.00–100.00% |
| Accuracy | Refractive Index: ±0.00002 nD |
| Brix | ±0.014% (0–85%) |
| Repeatability | Refractive Index: ±0.00001 nD |
| Brix | ±0.007% (<5%), ±0.01% (≥5%) |
| Resolution | Refractive Index: 0.00001 nD |
| Brix | 0.001% (<5%), 0.01% (≥5%) |
| Sample Volume | 0.2 mL |
| Prism Material | Sapphire |
| Temperature Resolution | 0.01 °C |
| Interface | LAN, USB, RS-232C |
| Compliance | ASTM D1218-21, ISO 1743:1982, GB/T 614-2021, GB/T 5527-2024, ICUMSA GS 4/3-13, OIML R 124 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Destructive Sampling Refractometer |
| Model | RA-620 / RA-600 |
| Measurement Principle | Sodium D-line (589.3 nm) Refractive Index at 20 °C |
| RI Range (RA-620) | 1.32000–1.58000 nD |
| RI Range (RA-600) | 1.3200–1.7000 nD |
| Brix Range | 0–100 % |
| RI Accuracy (RA-620) | ±0.00002 nD |
| RI Accuracy (RA-600) | ±0.0001 nD |
| Brix Accuracy (RA-620) | ±0.014 % |
| Brix Accuracy (RA-600) | ±0.1 % |
| RI Repeatability (RA-620) | ±0.00001 nD |
| RI Repeatability (RA-600) | ±0.0001 nD |
| Temperature Control Range | 5–75 °C (RA-600 optional up to 100 °C) |
| Temp. Resolution (RA-620) | 0.01 °C |
| Temp. Resolution (RA-600) | 0.1 °C |
| Minimum Sample Volume | 0.2 mL |
| Prism Material | Sapphire |
| Sample Stage Material | Stainless Steel SUS316 |
| Display | Full-color TFT touchscreen (Chinese/English/Japanese UI) |
| Data Storage | 100 methods, 300 results, 20 calibration logs |
| Interface | Ethernet (LAN), USB, RS-232C |
| Power | AC 100–240 V, 50/60 Hz, 20 W |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | RA-620 / RA-600 |
| Price | Upon Request |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | WBGT-203B |
| Price | Upon Request |
| WBGT Range | 0–50°C |
| Air Temperature Range | 0–50°C |
| Relative Humidity Range | 10–90% RH |
| Black Globe Temperature Range | 0–60°C |
| WBGT Accuracy | ±2°C (15–35°C) |
| Air Temp Accuracy | ±1°C (15–40°C) |
| RH Accuracy | ±3% RH (30–90%) |
| Black Globe Accuracy | ±1°C (20–60°C) |
| Alarm | Yes |
| Battery Life | ~70 hours continuous operation |
| Power Supply | Two AAA alkaline batteries (1.5 V each) |
| Weight | ~110 g |
| Accessories | Carrying case, batteries, operator manual |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | WBGT-302 |
| Pricing | Available Upon Request |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | WPA-1000 |
| Measurement Parameters | Total Phosphorus (TP) and Total Nitrogen (TN) |
| Instrument Type | Online Continuous Analyzer |
| Measurement Principle | Spectrophotometry (Molybdate Blue for TP |
| Measurement Range | TP: 0–0.5 mg P/L or 0–1 mg P/L (standard) |
| TN | 0–2 mg N/L or 0–5 mg N/L (standard) |
| Accuracy | ±2% of full scale (FS) |
| Detection Limit | 0.01 mg/L |
| Resolution | 0.001 mg/L |
| Optional Dilution Ratio | 2× to 500× |
| Sample Inlet Capacity | Up to 3 independent sample streams via automated selector valve |
| Waste Separation | Integrated dual-waste channel system |
| Reagent Delivery | Positive-displacement peristaltic pumping with quick-change cartridge design |
| Onboard Calculation | Real-time pollutant load estimation (kg/day) based on flow rate integration |