KEM (Kyoto Electronics Manufacturing)
Filter
Showing 31–60 of 81 results
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Class | Imported Laboratory Analytical Instrument |
| Models | DA-650, DA-645, DA-640 |
| Measurement Principle | U-shaped Oscillating Tube Method |
| Density Range | 0–3 g/cm³ |
| Temperature Control Range | 0.000–96.000 °C (DA-650) |
| Density Resolution | 1×10⁻⁶ g/cm³ (DA-650), 1×10⁻⁵ g/cm³ (DA-645), 1×10⁻⁴ g/cm³ (DA-640) |
| Accuracy | ±2×10⁻⁵ g/cm³ (DA-650), ±5×10⁻⁵ g/cm³ (DA-645), ±1×10⁻⁴ g/cm³ (DA-640) |
| Repeatability (SD) | 5×10⁻⁶ g/cm³ (DA-650), 1×10⁻⁵ g/cm³ (DA-645), 5×10⁻⁵ g/cm³ (DA-640) |
| Sample Volume | 1–2 mL |
| Measurement Time | 1–4 min (manual), 2–10 min (automated) |
| Compliance Standards | GB/T 29617–2013, GB/T 2013–2010, SH/T 0604–2000, ASTM D4052–22, ASTM D5002–22, EN ISO 12185:1996, EN ISO 15212-1:1999 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Instrument Type | Laboratory Benchtop Oscillating U-Tube Densimeter |
| Sample Type | Liquids Only |
| Density Range | 0–3 g/cm³ |
| Density Resolution | 1×10⁻⁶ g/cm³ |
| Density Repeatability | ±5×10⁻⁶ g/cm³ |
| Temperature Control Range | 0–96 °C (Peltier-regulated) |
| Temperature Accuracy | ±0.02 °C |
| Temperature Resolution | 0.001 °C |
| Minimum Sample Volume | 1–2 mL |
| Display | 5.7-inch TFT LCD with multi-language UI (English, Chinese, Japanese) |
| Compliance | ASTM D4052, ISO 12185, GB/T 29617, GB 5009.2, JJG 1058, BS EN ISO 15212-1 |
| Data Integrity | GLP-compliant audit trail, method storage (100 methods), calibration log, user access control |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DA-8 Series + RA-6 Series |
| Instrument Type | Oscillating U-tube Densimeter & Automatic Digital Refractometer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid Only |
| Density Range | 0–3 g/cm³ |
| Refractive Index Range | 1.32000–1.7000 nD |
| Temperature Control Range | 0–100°C (density), 5–75°C (refractometry) |
| Temperature Stability | ±0.001°C (DA-860), ±0.01°C (DA-850/DA-840, RA-620), ±0.1°C (RA-600) |
| Density Accuracy | ±0.000003 g/cm³ (DA-860), ±0.00001 g/cm³ (DA-850), ±0.00005 g/cm³ (DA-840) |
| Refractive Index Accuracy | ±0.00002 nD (RA-620), ±0.0001 nD (RA-600) |
| Repeatability | ±0.000001 g/cm³ (DA-860), ±0.000005 g/cm³ (DA-850), ±0.00005 g/cm³ (DA-840) |
| Integrated Peltier Thermostat | Yes |
| Viscosity Compensation | Yes (automated correction for high-viscosity liquids) |
| Auto-sampling Pump | Standard |
| Dryness Detection | Yes |
| Compliance | ASTM D1250, ASTM D4052, ISO 12185, ISO 2859, USP <841>, JIS K 0061, JIS K 2248 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | DA-840 |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±5 × 10⁻⁵ g/cm³ |
| Density Repeatability | ±5 × 10⁻⁵ g/cm³ |
| Temperature Range | 0–100 °C (Peltier-controlled) |
| Temperature Stability | ±0.01 °C |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 1 mL (manual), ~2 mL (auto-pump) |
| Measurement Time | ~10 s (to 4-digit precision) |
| Viscosity Correction | Automatic real-time correction |
| Bubble Detection | Integrated optical detection |
| Cleaning Mode | Fully automated rinse-dry cycle (vacuum + dual/triple wash + drying pump) |
| Interfaces | LAN, USB, RS-232C |
| Power | AC 100–240 V, 50/60 Hz, 40 W |
| Dimensions | 295 × 330 × 255 mm (W×D×H) |
| Weight | ~19 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | KEM |
| Product Type | Imported Instrument |
| Model | DA-850 |
| Measurement Time | 1–4 min |
| Alcohol Content Range | 0–100% v/v |
| pH Range | 0–14 |
| Dimensions (W×D×H) | 295 × 330 × 255 mm |
| Weight | 19 kg |
| Core Technology | U-Tube Oscillating Density Measurement |
| Density Accuracy | ±1 × 10⁻⁵ g/cm³ |
| Density Repeatability | ±5 × 10⁻⁶ g/cm³ |
| Temperature Control Accuracy | ±0.02 °C |
| Temperature Range | 0–100 °C (Peltier-controlled) |
| Sample Volume | ~1 mL (manual), ~2 mL (auto-pump) |
| Measurement Stabilization Time | ~10 s at target temperature |
| Compliance | GB 5009.225-2023, ISO 15212-1, OIML R 22 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | DA-850 |
| Instrument Type | Oscillating U-tube Density Meter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.00001 g/cm³ |
| Density Repeatability | ±0.000005 g/cm³ |
| Resolution | 0.00001 g/cm³ |
| Temperature Range | 0–100 °C (Peltier-controlled) |
| Temperature Stability | ±0.01 °C |
| Minimum Sample Volume | 1 mL (manual), ~2 mL (auto-pump) |
| Measurement Time | As fast as 10 seconds to 4-digit stability |
| Compliance | ASTM D4052, ISO 12185, IP 365, USP <841>, EP 2.2.5, JIS K 0061, GB/T 29617, GB/T 611, GB/T 2013, GB 5009.2, GB 5009.225, and pharmacopeial methods for relative density |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Oscillating U-tube Densimeter & Abbe-type Refractometer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids Only |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±1 × 10⁻⁵ g/cm³ |
| Density Repeatability | 5 × 10⁻⁶ g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Refractive Index Range | 1.3200–1.7000 nD |
| Refractive Index Accuracy | ±0.0001 nD |
| Refractive Index Resolution | 0.0001 nD |
| Temperature Control Range (Density) | 0–100 °C |
| Temperature Control Range (Refractometry) | 5–75 °C (optional: 5–100 °C) |
| Sample Volume Requirement | 1–2 mL |
| Temperature Regulation | Peltier-controlled |
| Auto-sampling | Integrated |
| Display Interface | Touchscreen tablet or external PC via USB/Ethernet |
| Calibration Standards | Air + distilled water (or certified reference materials) |
| Compliance | ASTM D4052, ASTM D1250, ISO 12185, ISO 2859, USP <841>, Ph. Eur. 2.2.39, JIS K 0061 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Instrument Type | Laboratory Benchtop Oscillating U-Tube Densimeter |
| Sample Type | Liquids |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±0.000003 / ±0.00001 / ±0.00005 g/cm³ |
| Temperature Control Range | 0–100 °C |
| Temperature Resolution | 0.001 °C / 0.01 °C / 0.01 °C |
| Repeatability | ±0.000001 / ±0.000005 / ±0.00005 g/cm³ |
| Resolution | 0.000001 / 0.00001 / 0.0001 g/cm³ |
| Minimum Sample Volume | 1–2 mL |
| Interface | LAN, USB, RS-232C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions | 295 × 330 × 255 mm (W×D×H) |
| Weight | ~19 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Instrument Type | Laboratory Benchtop Oscillating U-Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±3×10⁻⁶ g/cm³ |
| Density Repeatability | ±1×10⁻⁶ g/cm³ |
| Density Reproducibility | ±2×10⁻⁶ g/cm³ |
| Temperature Control Range | 0–100 °C (Peltier-regulated) |
| Temperature Stability | ±0.001 °C |
| Resolution | 1×10⁻⁶ g/cm³ |
| Minimum Sample Volume | 1 mL (manual), ~2 mL (auto-pump) |
| Measurement Time | ~10 s to 4-digit precision |
| Viscosity Correction | Automatic real-time correction |
| Bubble Detection | Integrated optical detection |
| Cleaning Mode | Fully automated rinse-dry cycle (vacuum, dual/triple solvent wash, drying air) |
| Data Interface | LAN, USB, RS-232C |
| Power | AC 100–240 V, 50/60 Hz, 40 W |
| Dimensions | 295 × 330 × 255 mm (W×D×H) |
| Weight | ~19 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Model | DA-860 |
| Measurement Principle | U-Tube Oscillation Method |
| Standard Compliance | ASTM D4052-22, EN ISO 12185:1996, EN ISO 15212-1:1999, GB/T 2013-2010, GB/T 29617-2013, SH/T 0604-2000 |
| Density Range | 0–3 g/cm³ |
| Accuracy | ±0.000003 g/cm³ |
| Repeatability | ±0.000001 g/cm³ |
| Temperature Control | 0–100 °C (Peltier), Resolution: 0.001 °C |
| Sample Volume | ~1 mL (syringe) or ~2 mL (pump) |
| Measurement Time | ~10 s (to 4-digit stability) |
| Interface | LAN, USB, RS-232C |
| Power | AC 100–240 V, 50/60 Hz |
| Dimensions | 295 × 330 × 255 mm |
| Weight | ~19 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | DA-8XX + RA-6XX |
| Product Type | Benchtop Refractometer & Density Meter |
| Temperature Control | Peltier-controlled, 0–100 °C (density), 5–75 °C (refractometer) |
| Digital Display | Yes |
| Refractive Index Range | 1.32000–1.70000 nD |
| Brix Range | 0.00–100.00% |
| Refractive Index Accuracy | ±0.0001 nD |
| Density Measurement Principle | U-tube oscillation method |
| Density Range | 0–3 g/cm³ |
| Density Accuracy (DA-860) | ±0.000003 g/cm³ |
| Density Repeatability (DA-860) | ±0.000001 g/cm³ |
| Sample Volume | ~1 mL |
| Viscosity Correction | Built-in automatic correction |
| Auto-sampling | Integrated peristaltic pump with auto-drying judgment |
| Interface | LAN, USB, RS-232C |
| Compliance | ASTM D1250, ISO 12185, ISO 2859, USP <841>, GLP/GMP-ready audit trail support |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | DCU-551 |
| Product Type | Benchtop Refractometer Auxiliary Module |
| Temperature Control | Integrated (via host refractometer) |
| Digital Display | Yes (via host unit) |
| Refractive Index Range Compatibility | 1.32–1.58 nD (with RA-620) / 1.32–1.70 nD (with RA-600) |
| Measurement Resolution | 0.00001 nD (RA-620 mode) / 0.0001 nD (RA-600 mode) |
| Sample Capacity | 1 × 20 mL glass vial |
| Fluid Handling | Vacuum-assisted pressurized aspiration |
| Automated Sequence | Sample aspiration, waste discharge, dual-solvent rinse (e.g., water + ethanol), nitrogen purge drying |
| Power Supply | AC 100–120 V / 200–240 V, 50/60 Hz, ~40 W |
| Dimensions | 291 mm (W) × 310 mm (D) × 342 mm (H) |
| Weight | 10 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | DCU-551H |
| Instrument Type | Oscillating U-tube Densimeter Accessory |
| Form Factor | Benchtop Laboratory System |
| Sample Phase | Liquid Only |
| Density Measurement Range | 0–3 g/cm³ |
| Density Resolution | 1 × 10⁻⁶ g/cm³ |
| Repeatability | ±1 × 10⁻⁶ g/cm³ |
| Temperature Control Range (Sampler) | Ambient to 80 °C |
| Minimum Sample Volume | 1–2 mL |
| Viscosity Handling Capability | Up to 50,000 mPa·s (via integrated vacuum-pressure pump) |
| Sample Vial | 20 mL glass bottle |
| Automation Functions | Auto-sampling, pressurized discharge, dual-solvent cleaning, dry-purge with compressed air |
| Power Supply | AC 100–120 / 200–240 V, 50/60 Hz, ~190 W |
| Dimensions (W×D×H) | 400 × 350 × 450 mm |
| Weight | 17 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DCU-551N |
| Instrument Type | Oscillating U-Tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Phase | Liquid Only |
| Density Range | 0–3 g/cm³ |
| Temperature Control Range | 0–96 °C |
| Repeatability | ±1 × 10⁻⁶ g/cm³ |
| Resolution | 0.000001 g/cm³ |
| Minimum Sample Volume | 1–2 mL |
| Viscosity Compatibility | Up to 50,000 mPa·s (via integrated vacuum-pressure pump) |
| Sample Vessel | 20 mL glass vial |
| Power Supply | AC 100–120 V / 200–240 V, 50/60 Hz, ~40 W |
| Dimensions (W×D×H) | 291 × 310 × 342 mm |
| Weight | 10 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | DCU-600 |
| Instrument Type | Oscillating U-tube Density Meter Accessory |
| Form Factor | Benchtop Laboratory Unit |
| Sample Type | Liquids Only |
| Density Range | 0–3 g/cm³ |
| Temperature Control Range | 0–96 °C |
| Minimum Sample Volume | ~5 mL |
| Compatibility | Designed exclusively for KEM DA-640, DA-645, and DA-650 digital density meters |
| Automation Functions | Automated sample aspiration, measurement triggering, waste discharge, dual-solvent cleaning (Wash 1 & Wash 2), nitrogen-assisted drying, and cell integrity verification |
| Sample Vessel | 20–100 mL beaker or 100 mL disposable cup |
| Power Supply | DC 24 V, 5 A (AC adapter included) |
| Dimensions (W×D×H) | 214 × 295 × 304 mm |
| Weight | Approx. 5.5 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Designation | Electrode Series for DV-100 / AT-710 / AT-710M Titrators |
| Measurement Range | ±20 pH, ±2000 mV |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | 0.001 pH, 0.1 mV |
| Titration Potential Stability | ±0.3 mV |
| Analog-to-Digital Resolution | 1/20000 (16-bit ADC) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | EMS-1000S |
| Instrument Type | Rotational Viscometer (Fixed-Base, Non-Contact) |
| Operating Environment | Ambient Temperature (10–30°C), ≤85% RH (non-condensing) |
| Viscosity Range | 0.1–1,000,000 mPa·s (dependent on sphere diameter and material) |
| Temperature Range | 0–200°C |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ±0.1°C |
| Minimum Sample Volume | 90 µL (with optional micro-cell & 2 mm sphere) |
| Rotational Speed Range | 500–1000 rpm |
| Speed Stability | ±3% |
| Viscosity Repeatability | RSD ≤3% (per KEM standard test conditions) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | GVA-700 |
| Measurement Time | 90 sec (CO₂ volume only) / 6–16 min (CO₂ + air + O₂) |
| Pressure Range | 9.8 kPa to 0.490 MPa (0.1–5.0 kgf/cm²G) |
| Temperature Range | 0–50 °C |
| Residual Gas Volume | 0–30 mL |
| Oxygen Concentration | 0–21% (detection limit: >8 mL residual gas) |
| Accuracy | ±0.001 MPa (pressure), ±0.05 °C (temperature), ±2% rel. (residual gas ≥5 mL), ±0.1 mL (residual gas <5 mL), ±0.2% (O₂) |
| Sample Compatibility | PET bottles ≤2.0 L, cans (e.g., 190 mL), max. Ø110 × H320 mm |
| Dimensions | 495(W) × 555(D) × 570(H) mm |
| Weight | 38 kg |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz ±1 Hz |
| Power Consumption | 20 W |
| Air Supply Requirement | 0.490–0.686 MPa (5–7 kgf/cm²G) |
| Data Interface | RS-232C, USB |
| Display | 16-character × 1-line backlit LCD |
| Method Storage | 20 user-defined methods |
| Result Storage | 100 measurements internally + export via USB |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | GVA-710 |
| Measurement Time | ~90 sec (CO₂ volume only) |
| pH Range | 0–14 |
| Dimensions (W×D×H) | 495 × 555 × 570 mm |
| Weight | ~38 kg |
| Pressure Range | 0.010–0.500 MPaG |
| Temperature Range | 0–50 °C |
| Residual Gas Volume | 0–30 mL |
| O₂ Concentration | 0–21% (detection limit: >8 mL residual gas) |
| Accuracy | ±0.001 MPa (pressure), ±0.05 °C (temperature), ±2% rel. (residual gas ≥5 mL), ±0.1 mL (residual gas <5 mL), ±0.2% (O₂) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HG-37N |
| Price Range | USD 68,000 – 136,000 (FOB Japan) |
| Measurement Principle | Cold Vapor Atomic Absorption Spectroscopy (CVAAS) with Dry Oxidation-Reduction Conversion |
| Measurement Range | 0–50 µg/m³N or 0–1000 µg/m³N (switchable) |
| Response Time | ≤90 s |
| Repeatability | ±1% of reading |
| Linearity Error | ±2% of full scale |
| Zero Drift | ≤±1% per week |
| Sample Gas Flow Rate | 300 mL/min |
| Calibration Interval | Recommended every 30 days |
| Interference Resistance | Immune to Cl⁻, SO₂, NOₓ, H₂O vapor, and particulate carryover under ISO 15202-compliant sampling conditions |
| Compliance | Designed to meet EPA Method 29, ASTM D6784-22, and EN 14181 QAL1 requirements for mercury CEMS |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HL-36NS |
| Pricing | Upon Request |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Kyoto Electronics Manufacturing Co., Ltd. |
| Model | MKC-710 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Moisture Range | 1 µg – 300 mg H₂O (up to 1000 mg with extended range) |
| Precision | RSD < 0.3% (n = 10, per certified reference materials and ASTM E203) |
| Electrode System | Dual-platinum detection electrodes with AC polarization |
| Cell Type | Membrane-separated or membrane-free electrolytic cell |
| Resolution | 0.1 µg H₂O |
| Max. Electrolysis Rate | 2.6 mg H₂O/min |
| Display | 8.4″ color LCD (800 × 600), multilingual UI (English, Japanese, Chinese, Korean, Russian, Spanish, German, French) |
| Data Storage | 500 sample results (MKC-710M), GLP-compliant audit trail, operator/group management, reagent lifetime tracking, scheduled performance verification |
| Interface | RS-232C × 4, USB × 1, SS-BUS, APBLAN |
| Environmental Operating Range | 5–35 °C, ≤85% RH |
| Power | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | ~30 W (main unit), ~7 W (printer) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MKC-710B |
| Measurement Principle | Coulometric Titration |
| Measurement Range | 8 µg – 300 mg Br₂ |
| Resolution | 0.1 µg Br₂ |
| Detection Method | Dual Platinum Electrode AC Polarization |
| Endpoint Detection | Real-time Current-Based Endpoint Confirmation |
| Control Mode | Constant-Current Pulse Time Control |
| Data Storage | 100 Sample Records |
| GLP Compliance | Operator ID, Group Management, Reagent Tracking, Performance Verification Logs, Timestamped Audit Trail |
| Connectivity | RS-232C (printer, balance, PC), USB Host (U-disk, thermal printer, barcode scanner, foot switch, USB hub, Android devices) |
| Environmental Operating Conditions | 5–35 °C, ≤85% RH |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | ~20 W (main unit), ~7 W (optional printer) |
| Dimensions (Titration Unit) | 141 × 292 × 244 mm (W×D×H) |
| Weight (Titration Unit) | ~3.0 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MKC-710B |
| Titration Mode | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 300 mg H₂O (equivalent to 100 ppb – 100% w/w) |
| Accuracy | ≤ 0.3% RSD (n = 10, per ASTM E1064 & GB/T 26793-2011) |
| Minimum Dosing Resolution | 0.1 µg |
| Titration Control Precision | ±0.3% of set current pulse duration |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MKC-710D |
| Titration Mode | Fully Automated Coulometric Titration |
| Method Type | Coulometric Karl Fischer Titration |
| Measurement Resolution | 0.1 µg H₂O |
| Moisture Content Range | 1 ppm – 100% w/w |
| Accuracy | ≤0.3% RSD (n=10) |
| Minimum Electrolytic Water Generation Rate | 2.6 mg H₂O/min |
| Titration Control Precision | ±0.3% |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Dual-Mode Karl Fischer Analyzer (Coulometric + Volumetric) |
| Measurement Resolution | 0.1 µg |
| Moisture Range | 1 ppm to 100% H₂O |
| Accuracy | < 0.3% RSD (n = 10) |
| Minimum Dispensing Increment | 1/20,000 |
| Titration Control Precision | 0.1 µg |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage | Internal memory (500 samples for MKC-710M |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MKC-710M |
| Titration Mode | Fully Automatic Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 300 mg H₂O (up to 1000 mg with optional configuration) |
| Accuracy | ≤0.3% RSD (n=10, certified reference materials) |
| Minimum Dosing Resolution | 0.1 µg |
| Repeatability | <0.3% RSD |
| Titration Control Precision | 0.1 µg |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Data Storage Capacity | 500 sample records |
| GLP Compliance | Operator logging, reagent tracking, performance verification, time-stamped audit trail |
| Communication Interfaces | RS-232C, USB (host/device), LAN |
| Expandability | Up to 4 titration units |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Analytical Instrument |
| Model | MKC-710M / MKC-710S / MKC-710B + ADP-513 |
| Pricing | Upon Request |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MKC-710S + ADP-611 |
| Price Range | USD 14,000 – 70,000 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 300 mg H₂O (extendable to 1000 mg) |
| Accuracy | ≤0.3% RSD (n=10) |
| Minimum Electrolytic Generation Rate | 2.6 mg H₂O/min |
| Repeatability | <0.3% RSD |
| Cell Configuration | Membrane-type or Membrane-free Coulometric Titration Cell |
| Titration Control Precision | ±0.3% |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 sample records |
| Compliance | GLP-ready with operator/group logging, reagent tracking, performance verification, and time-stamped audit trail |