Micromeritics
Filter
Showing 1–30 of 32 results
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | 3Flex Series |
| Instrument Type | Physical & Chemical Sorption Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Gas Inlet Ports | 16 |
| High-Temperature Furnace Range | Up to 1100 °C |
| Pressure Range | P/P₀ down to 10⁻⁹ |
| Core Functional Capabilities | High-Precision TPR, TPO, and TPD Analysis |
| Sensor Resolution | 29-bit A/D Conversion |
| Manifold Architecture | Independently temperature-controlled (45 °C)歧管, P₀ tube, and analysis stations |
| Vacuum Control | Servo-Valve-Actuated Automated Gas Dosing & Evacuation |
| Sealing Standard | 316 Stainless Steel VCR Fittings |
| Optional Modules | Steam Sorption (H₂O & Organic Vapors), Kr Adsorption for Low-Surface-Area Materials, TCD-Based Chemisorption |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | 3Flex |
| Analysis Stations | 3 |
| Measurement Principle | Static Volumetric Method |
| Analyte Gases | N₂, Ar, Kr, CO₂, H₂, CH₄, and optional vapors (e.g., H₂O, ethanol) |
| Minimum Relative Pressure (P/P₀) | 1×10⁻⁹ |
| Pressure Resolution | Down to 10⁻⁶ mmHg |
| Sample Compatibility | Microporous, mesoporous, and macroporous solids including MOFs, zeolites, activated carbons, catalysts, and metal oxides |
| Software | MicroActive™ v4.x with NLDFT/QSDFT kernel, Python API support, 21 CFR Part 11-compliant audit trail option |
| Compliance | ASTM D3663, ISO 9277, ISO 15901-2, USP <846>, GLP/GMP-ready configuration available |
| Data Export | CSV, PDF, XML, HDF5 |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | 3Flex |
| Gas Adsorption Capability | Physisorption & Chemisorption (optional) |
| Tri-Station Operation | Independent simultaneous analysis |
| Pressure Range | Down to 1×10⁻⁹ P/P₀ |
| Detection Limit | Ultra-micropore resolution (≤ 0.7 nm) |
| Vapor Compatibility | Integrated thermostatted manifold (45 °C ±0.05 °C), optional heated vapor dosing |
| Software | MicroActive™ with customizable reporting, ASTM/ISO-compliant data processing |
| Sample Preparation | In-situ tube heater for degassing under vacuum or inert gas |
| Sealing System | Metal-sealed, hard-stop valves with corrosion-resistant manifold |
| P₀ Measurement | Dedicated P₀ sensor with continuous saturation pressure monitoring |
| Fluid Library | >80 pre-loaded adsorbates (N₂, Ar, CO₂, H₂, Kr, H₂O, alcohols, hydrocarbons, etc.) |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AccuPore |
| Measurement Principle | Capillary Flow Porometry (CFP) |
| Standard Compliance | ASTM F316 |
| Pore Size Range | 0.013–500 µm (fluid-dependent) |
| Maximum Pressure | 500 psi (35 bar) |
| Gas Flow Rate Range | Up to 200 L/min |
| Sample Diameters Supported | 13 mm, 25 mm, 47 mm |
| Data Resolution | >1000 data points per run |
| Sampling Rate | 20 Hz |
| Operating Gases | Air or Nitrogen |
| Measurement Modes | Bubble Point, Wet/Dry, Wet/Calculated-Dry, Wet/Dry Flow Curve Analysis |
| Sample Prep Time | <30 s |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AccuPyc III 1350 |
| Instrument Type | True Density Analyzer |
| Configuration | Benchtop Laboratory System |
| Sample Form | Solid Powders, Granules, Monoliths |
| Measurement Principle | Gas Displacement (Helium/Nitrogen/Air) |
| Density Range | 0.1–100 cm³ (Sample Volume Capacity) |
| Accuracy | ±0.02% |
| Repeatability | ±0.01% |
| Temperature Control Range | 4 °C to 60 °C |
| Temperature Stability | ±0.025 °C |
| Minimum Sample Volume | 0.1 cm³ |
| Compliance | ASTM D5550, ISO 12154, USP <699>, GLP/GMP-ready audit trail support |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASAP 2020 |
| Pricing | Available Upon Request |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | ASAP 2020 PLUS |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption |
| Analysis Stations | 1 |
| Pore Size Range | 0.35–500 nm |
| Relative Pressure Range | P/P₀ ≥ 10⁻⁸ |
| Theoretical Basis | Gas Adsorption Isotherm Analysis (BET, BJH, DFT, NLDFT, t-plot, αₛ-plot) |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | ASAP 2020 Plus Series |
| Gas Inlet Ports | 12 |
| Heating Temperature Range | Ambient to 1100 °C |
| Pressure Range | 0–1000 mmHg |
| Analytical Functions | TPD, TPR |
| Optional Configurations | Steam Adsorption, Micropore Analysis (0.1 mmHg sensor + high-vacuum pump), Corrosion-Resistant Stainless Steel Manifold, Cryogenic Cooling Access |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | ASAP 2020 Plus HD88 Series |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Method |
| Analysis Stations | 1 adsorption station |
| Degassing Stations | 2 independent stations |
| Pressure Range | 0–1000 mmHg |
| Applicable Pore Types | Micropores, Mesopores, Low Surface Area Materials |
| Theory | BET, Langmuir, BJH, DFT, NLDFT, t-plot, αs-method |
| Repeatability | <1% RSD |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corporation |
| Model | ASAP 2050 |
| Measurement Principle | Volumetric (Manometric) High-Pressure Adsorption |
| Temperature Range | 20–120 °C (operational analysis range) |
| Pressure Range | 10⁻⁶ Torr to 10 atm (1.013 MPa) |
| Ultimate Vacuum | <1×10⁻⁶ Torr |
| Sample Tube Material | Stainless Steel (straight-walled, rated to 150 psi) |
| Degassing Control | Independent dual-station programmable heating (temperature ramp rate & hold time user-defined) |
| Optional Cooling | Liquid nitrogen or argon cryogenic Dewar |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | ASAP 2425 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Gas Adsorption (Volumetric Method) |
| Number of Analysis Stations | 6 |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | 0–950 mmHg |
| Adsorption Theory | Brunauer-Emmett-Teller (BET), t-plot, Langmuir, DFT, NLDFT |
| Sample Preparation Stations | 12 independent, temperature-controlled (ambient to 450 °C) |
| Optional Configurations | Low-surface-area mode (Kr adsorption, 10 mmHg transducer), Micropore-enhanced mode (1 mmHg transducer) |
| Software | MicroActive v5.x with ASTM/ISO-compliant reporting, FDA 21 CFR Part 11 audit trail capability |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | ASAP 2460 |
| Configuration | Dual-Station Base Module (Expandable to 4- or 6-Station) |
| Gas Dosing | Servo-Valve Controlled Quantitative Gas Injection & Evacuation |
| Gas Inlets | 5 Total (Including Dedicated Free-Space Measurement Inlet) |
| Analysis Duration Without Refill | Up to 60 h |
| BET Surface Area Throughput | 6 Samples in ≤30 min (with Two Expansion Modules) |
| Software Platform | MicroActive v4.x |
| Theoretical Models Supported | BET, Langmuir, t-Plot, DFT, NLDFT |
| Optional Configurations | Low-Surface-Area (Kr) Mode (10 mmHg Transducer), Micropore Mode (1 mmHg Transducer, Enhanced Low-Pressure Resolution, Compatible with N₂, Ar, CO₂, H₂) |
| Compliance Framework | Designed for GLP/GMP-aligned workflows |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | ASAP 2460 Series |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Gas Adsorption (Volumetric Method) |
| Number of Analysis Stations | 2–6 (Modular Expansion) |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | 0–1000 mmHg (absolute) |
| Analytical Theory | Gas Adsorption Isotherm Analysis (N₂, Ar, CO₂, H₂, Kr) |
| Optional Configurations | Low-Surface-Area (Kr), Micropore-Optimized (1 mmHg Transducer) |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AutoChem II 2920 |
| Temperature Range | –110 °C to 1100 °C |
| Detection Method | High-Stability TCD (Thermal Conductivity Detector) |
| Gas Inlets | 12 |
| Automated Valves | 4 × 6-port valves |
| Mass Flow Controllers | 4 (sample prep, dual carrier/reference, analysis) |
| Sample Tube | FlowThru™ quartz, rated to 1100 °C |
| TCD Zone Temperature | 150–250 °C |
| Optional Accessories | Online MS/FTIR/GC interface, vapor generator, cryogenic bath (–110 °C) |
| Software | Windows-based AutoChem software with GRAMS/32 peak processing module |
| Analytical Modes | TPD, TPR, TPO, TPRx, pulse chemisorption, isothermal reaction, BET surface area |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AutoChem III |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Gas-solid surface reaction kinetics and thermal desorption analysis |
| Number of Gas Inlets | 18 |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | Up to 100 °C/min from –100 °C to 800 °C |
| Core Functions | Pulse chemisorption, Temperature-Programmed Reduction (TPR), Single-point BET surface area estimation |
| Cooling System | Integrated air-cooled AutoCool™ (no liquid nitrogen or external chiller required) |
| Sample Tube Interface | Patented KwikConnect™ one-piece sealed sample tube assembly (US Pat. No. 11,105,825 B2) |
| Water Removal Technology | AutoTrap™ integrated condensate management for TPR (US Pat. No. 10,487,954 B) |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AutoPore V Series |
| Pore Size Range | 3 nm – 1100 µm |
| Pressure Range | 0.2 – 50 psia |
| Intrusion/Extrusion Volume Precision | < 0.1 µL |
| Compliance | ASTM D4284, D4404, D6761 |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | BTA |
| Instrument Type | Physical/Chemical Adsorption Analyzer |
| Measurement Principle | Dynamic Breakthrough Adsorption |
| Gas Inlet Ports | 6 |
| Maximum Heating Temperature | 1,050 °C |
| Isothermal Stability Range | Up to 200 °C |
| Pressure Range | Up to 30 bar |
| Key Functionality | Competitive Adsorption, Multi-component Transient Adsorption Profiling |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | ChemiSorb Auto |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Flow Method |
| Gas Inlet Ports | 8 |
| Maximum Heating Temperature | 1000 °C |
| Heating Rate | 1–50 °C/min |
| Analytical Capabilities | TPR, TPO, TPD, Pulse Chemisorption |
| Optional CryoCooler Range | −100 °C to 1000 °C |
| Carrier Gas Ports | 4 |
| Loop Gas Ports | 4 |
| Detector | Thermal Conductivity Detector (TCD), optional Mass Spectrometer (MS) integration |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | ChemiSorb HTP |
| Principle | Static Volumetric Method |
| Gas Inlet Ports | 12 |
| Analysis Stations | 6 |
| Temperature Range | Ambient +10 °C to 700 °C |
| Sample Reactor | Quartz with Overflow Channel Design |
| Automation Level | Fully Automated |
| Software Interface | Windows-Based Control & Reporting Platform |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | 5390 |
| Principle | Electrical Sensing Zone (Coulter Principle) |
| Size Range | 0.4–1200 µm (20:1 to 30:1 dynamic range per orifice) |
| Concentration Range | 1–1000 ppm (v/v) |
| Sensing Rate | 1–5,000 particles/sec |
| Analysis Time | 10–100 sec (as low as 1 sec) |
| Repeatability | ±1% (n=10, same sample) |
| Reproducibility | ±1.5% (inter-instrument) |
| Electrolyte Compatibility | Aqueous, organic, or solvating organic media |
| Regulatory Compliance | FDA 21 CFR Part 11 compliant software |
| Brand | Micromeritics |
|---|---|
| Origin | Spain |
| Model | FR-50, FR-100, FR-200 |
| Construction Material | Stainless Steel (316 SS) |
| Operating Pressure Range | Ambient to 100 bar or 200 bar (model-dependent) |
| Temperature Range | Ambient to 1000 °C |
| Number of Gas Inlets | Up to 6 |
| Mass Flow Controllers | Up to 6 integrated MFCs |
| Phase Separation | Integrated low-dead-volume gas–liquid or gas–liquid–liquid separator (US Pat. 7895891 B2 |
| Pressure Control Accuracy | ±0.1 bar (US Pat. 8740181 B2) |
| Safety System | Redundant pressure/temperature monitoring, automated shutdown, audible/visual alarms, fail-safe valve actuation |
| Brand | Micromeritics |
|---|---|
| Origin | United Kingdom |
| Model | FT4 |
| Instrument Type | Multifunctional Powder Flowability Tester |
| Measurable Powder Parameters | Flow Function, Flow Energy, Aeration Energy, Consolidation Energy, Compressibility, Permeability, Wall Friction Angle |
| Maximum Sample Vessel Capacity | 160 mL |
| Minimum Sample Volume | 1 mL (with optional mini shear cell) / 10 mL (standard) |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | Gemini VII 2390 Series |
| Analysis Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 1 |
| Specific Surface Area Range | 0.01 m²/g to unlimited |
| Pressure Range | 0–1000 mmHg |
| Measurement Theory | Gas Adsorption (BET, Langmuir, t-Plot, HK, BJH) |
| Software Options | Keypad Embedded Firmware, Gemini Windows Software, FDA 21 CFR Part 11-Compliant Confirm Software |
| Dual-Mode Operation | Standalone Keypad or PC-Controlled |
| Compliance | ASTM D3663, ISO 9277, USP <846>, GLP/GMP-ready audit trail (Confirm version) |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | Gemini VII 2390 Series |
| Analysis Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 1 |
| Specific Surface Area Range | ≥0.01 m²/g (no upper limit) |
| Pressure Range | 0–1000 mmHg |
| Adsorptive Gas | N₂ (optimized for liquid nitrogen bath), He, Ar, O₂, CO₂, CH₄, C₄H₁₀ |
| Relative Pressure (P/P₀) Range | 0–1.0 (adsorption only) |
| P/P₀ Resolution | <10⁻⁴ |
| Pressure Resolution | <0.1 mmHg |
| Sensor Accuracy & Linearity | ±0.5% of full scale |
| Operating Temperature | 10–35 °C |
| Relative Humidity | 20–80% RH (non-condensing) |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | GeoPyc 1365 |
| Instrument Type | Benchtop Envelope Density Analyzer |
| Sample Form | Solids (powders, granules, irregular solids, tablets, foams) |
| Measurement Principle | Solid displacement using Dry Flo™ quasi-fluid medium |
| Envelope Volume Range | 0.3–25 cm³ (via interchangeable sample cups) |
| Density Accuracy | <0.15% deviation vs. ASTM D1895, D6342, D7481 |
| Operating Temperature | 15–35 °C |
| Minimum Sample Requirement | ≥25% of selected cup volume |
| Compliance | ASTM D1895 (Type A), D6342, D7481, ISO 697, USP <699>, FDA 21 CFR Part 11 (with optional audit trail module) |
| Optional T.A.P. Density Module | Programmable consolidation force (0.5–10 N), stepwise compression cycles, real-time force & displacement monitoring |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | HPVA-II |
| Measurement Principle | Static Volumetric Method (High-Pressure Capacity Technique) |
| Temperature Range | 30 K to 500 °C |
| Pressure Range | Ultra-High Vacuum (≤1×10⁻⁹ Torr) to 200 bar |
| Vacuum Level | <1×10⁻⁹ Torr |
| Compatible Gases | H₂, CH₄, CO₂, N₂, Ar, and other non-corrosive gases |
| Sample Requirement | As low as 5–50 mg |
| Sample Types | MOFs, Zeolites, Activated Carbons, Porous Polymers, Metal Hydrides, Catalyst Supports |
| Thermal Control Options | Liquid Cryogen Dewar (4 L stainless steel), External Circulating Bath, Resistive Heating Furnace, Closed-Cycle Cryocooler Integration |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ICCS |
| Quotation | Upon Request |
| Operating Pressure | Up to 20 bar(g) |
| Valve Box Temperature Range | Up to 180 °C |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | SAS II 5800 |
| Measurement Range | 0.2–75 µm |
| Repeatability | ±1% RSD |
| Porosity Range | 0.2–0.9 |
| Compliance | ASTM B330-12, ASTM C721-14 |
| Display | Integrated Touchscreen Interface |
| Control Software | SAS Control Suite v5.x |
| Dimensions (H×W×L) | 55 × 50 × 38 cm |
| Weight | 28 kg |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | SediGraph III Plus |
| Measurement Principle | X-ray sedimentation |
| Measurement Range | 0.1–300 µm |
| Repeatability | < 1% RSD |
| Accuracy | < 1% error vs. NIST-traceable standards |
| Analysis Time | 3–15 minutes per sample |
| Sample Volume | 50 mL dispersion |
| Compliance | ISO 13317-3, ASTM B761, ASTM C28 (Advanced Ceramics) |
| Automation | Unattended analysis of up to 18 samples |
| Optional Integration | MasterTech Auto-sampler for process monitoring and cloud data export |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | TriStar II Plus 3030 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption |
| Number of Analysis Stations | 3 |
| Specific Surface Area Range | 0.001 m²/g to unlimited |
| Pressure Range | 0–1000 mmHg |
| Theoretical Basis | Gas Adsorption Analysis |
| Construction | Corrosion-Resistant Stainless Steel Manifold |
| Cryogenic Duration | >40 hours with optimized Dewar design |
| Software Platform | MicroActive v4.x with Python scripting support |
| Compliance Ready | ASTM D3663, ISO 9277, ISO 15901-2, USP <846>, IUPAC 2015 recommendations |