Narishige
Filter
Showing 91–120 of 257 results
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IM-3 |
| Operating Pressure Range | 50–500 kPa |
| Time Setting Range | 10 ms – 99.99 s |
| Count Setting Range | 1–99 |
| Interval Setting Range | 10 ms – 99.99 s |
| Power Supply | AC 100–240 V (±5%), 50/60 Hz |
| Dimensions (Main Unit) | 240 × 215 × 130 mm |
| Weight (Main Unit) | 4 kg |
| Compatible Syringe Diameter | Ø5–Ø10 mm |
| Syringe Plunger Travel | 50 mm |
| Fine Adjustment Step | 500 µm |
| Accessories Included | HI-7 Syringe Holder, Tubing Connectors, Silicone O-Rings, AC Power Cord, Footswitch |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | IM-300 |
| Input Pressure Range | 60–100 psi (0.4–0.7 MPa) |
| Injection Pressure Range | 0.1–60 psi (0.7 kPa–0.4 MPa) |
| Balance Pressure Range | 0–10 psi (0–0.07 MPa) |
| Time Resolution | 10 ms–327.66 s |
| Step Count Range | 1–255 |
| Programmable Sequences | 10 × 100 steps |
| TTL Output | 8-bit |
| Power Supply | AC 100–120 V / 220–240 V, 50/60 Hz |
| Power Consumption | ~25 W |
| Dimensions | 425 × 205 × 90 mm |
| Weight | 3.7 kg |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | IM-31 |
| Operating Modes | Count Mode (Pressure/Time/Count), Footswitch Mode (Pressure Only) |
| Pressure Range | 50–500 kPa |
| Time Setting Range | 10 ms – 99.99 s |
| Count Setting Range | 1–99 |
| Interval Setting Range | 10 ms – 99.99 s |
| Input Voltage | AC 100–240 V (±5%), 50/60 Hz |
| Dimensions | 240 × 215 × 130 mm |
| Weight | 4 kg |
| TTL Input | Negative logic compatible |
| Compatibility | Modular integration with Narishige micromanipulators (e.g., MMO-4, MDO-84) via adapter kits |
| Accessories | HI-7 syringe holder, tubing connectors, footswitch, silicone O-rings, power cord |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | IM-400 |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Gas Input Pressure Range | 0.4–0.7 MPa |
| Injection/Balance Pressure Range | 0.005–0.5 MPa |
| Flushing Pressure Range | 0.4–0.7 MPa |
| Control Box Dimensions | 120 × 211 × 264 mm, 3.1 kg |
| Operation Unit Dimensions | 130 × 153 × 61.5 mm, 780 g |
| Power Consumption | 15 W |
| Fuse Rating | T1A/250V (EN60127-2 Sheet 3) |
| Accessories Included | HI-9 injection holder, CT-4 injection tube (Ø2 mm × 1.2 m), gas input hoses (Ø6 mm × 2 m & Ø6 mm × 1 m), tube fittings, T-joint with pressure relief valve, foot switch (2.9 m cable), connecting cable (2.9 m), power cord (1.5 m), silicone rubber gasket (HI01PK01) |
| Brand | Narishige |
|---|---|
| Model | IM-400 |
| Origin | Japan |
| Detection Time | 10 s (manual focusing) or 15 s (autofocusing) at ~1,000,000 cells/mL |
| Cell Concentration Range | 5×10⁴–10⁷ cells/mL |
| Sample Volume | 10 µL |
| Throughput | 50,000 cells |
| Detectable Cell Diameter | 1–60 µm |
| Operating Gas Pressure (Injection/Balance) | 0–0.5 MPa |
| Supply Pressure Range | 0.4–0.7 MPa |
| Power Input | AC 100–240 V, 50/60 Hz |
| Power Consumption | 15 W |
| Control Unit Dimensions | 120 × 211 × 264 mm, 3.1 kg |
| Manipulator Unit Dimensions | 130 × 153 × 61.5 mm, 780 g |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IM-400B |
| Supply Pressure Range | 0.4–0.7 MPa |
| Aspiration Pressure | ≈ −0.08 MPa |
| Dimensions | 53 × 200 × 190 mm (W × D × H) |
| Weight | 1.6 kg |
| Accessories | 150-mm connection cable, 6-mm ID inlet tubing with Y-union fitting, 2-mm ID injection tube with Y-union fitting |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IM-6 |
| Plunger Stroke | 40 mm |
| Knob Full Rotation Displacement | 500 µm |
| Maximum Syringe Volume | 800 µL |
| Knob Full Rotation Volume Increment | ~10 µL |
| Dimensions (W×D×H) | 200 × 80 × 130 mm |
| Weight | 2 kg |
| Accessories | IM-H1 Syringe Holder, O-rings, Silicone Rubber Pad, IM-AS-2 Oil Add-on Kit |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | IM-9B |
| Total Capacity | 1,060 µL |
| Plunger Stroke | 53 mm |
| Knob Full Rotation Volume | ~10 µL |
| Knob Full Rotation Travel | 500 µm |
| Dimensions (W×D×H) | 175–228 × 55 × 77 mm |
| Weight | 0.65 kg |
| Interface | Luer-lock (Ø7–14 mm compatible) |
| Accessories | IM-H1 Holder Set, O-rings (IMO2), Silicone Grease, Silicone Rubber Gasket (HI01PK01), Allen Wrench, Three-way Stop Cock, Cleaning Rod, Metal Syringe (1,060 µL) |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | IM-AS-2 |
| Price Range | USD 68–92 |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | IM-H1 |
| Pricing | Available Upon Request |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | IM-HD1 |
| Dimensions | 24 × 55 × 54 mm |
| Weight | 58 g |
| Compatible Pipettes | CT-4 (inner diameter 0.4 mm), CT-1-1.5 (inner diameter 1.5 mm) |
| Actuation | Pneumatic (foot or finger-controlled via manipulator linkage) |
| Includes | HI-9 Injector Holder, Cleaning Rod, HIO1PKO1 Silicone Gasket, Hex Wrench |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IM-HD1T |
| Dimensions | 24 × 55 × 54 mm (W×D×H) |
| Weight | 58 g |
| Construction | Stainless steel housing with ergonomic form factor |
| Actuation | Pneumatic (external air supply required) |
| Control mode | Manual trigger + optional external TTL/relay interface for automated integration |
| Compatible syringes | Standard 10 µL–100 µL glass or plastic microsyringes (e.g., Drummond Nanoject, Hamilton 7000 series) |
| Accessories included | HI-9 injector holder, CT-4 polyimide tubing (0.28 mm ID), CT-1-1.5 fused silica capillary tubing (1.5 m length), HIO1PKO1 silicone O-rings, hex wrench |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | IMS-10 |
| Drive Unit Dimensions | 20 × 30 × 130 mm, 0.16 kg |
| Control Unit Dimensions | 65 × 85 × 60 mm, 0.3 kg |
| Power Supply Unit Dimensions | 125 × 105 × 85 mm, 1.5 kg |
| Stroke Range (Fine Adjustment) | 40 mm |
| Speed Range | 24–180 µm/s |
| Power Input | AC 100–240 V (±5%), 50/60 Hz |
| Power Consumption | 15 W |
| Included Accessories | AC Power Cord, Syringe Mounting Knobs |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IMS-3 |
| Syringe Travel Range | 5–10 mm |
| Plunger Displacement per Full Knob Rotation | 500 µm |
| Dimensions (W×D×H) | 50 × 30 × 120 mm |
| Weight | 115 g |
| Injection Volume Control via Interchangeable Syringes (Bore Diameter | 5–10 mm) |
| Accuracy | ±0.5% |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IMS-30 |
| Drive Motor | 5-phase stepper motor |
| Stroke Range | 60 mm |
| Operating Voltage | AC 100–240 V, 50/60 Hz |
| Power Consumption | 15 W |
| Dimensions (Driver Unit) | 47.5 × 82.5 × 156.5 mm, 456 g |
| Dimensions (Control Unit) | 180 × 260 × 95 mm, 2.5 kg |
| Included Accessories | 1.5-m power cord, 1.5-m connection cable, dedicated mounting screws, two hex wrenches, spare fuses (installed in fuse holder) |
| Syringe Compatibility | Pre-programmed Hamilton syringe codes (e.g., 7001/7101 for 1 µL, 7002/7102 for 2 µL, 702/1702 for 25 µL, etc.), inner diameter range: 0.103–2.304 mm, volume range: 0.5–250 µL |
| Mounting Options | Direct screw-in or bracket-mounted integration with stereotactic micromanipulators |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IP |
| Dimensions | 250 × 200 × 6 mm |
| Weight | 2.4 kg |
| Material | Steel with white or beige anti-corrosive coating |
| Compatible Accessories | GJ-1, GJ-8 magnetic stands |
| Includes | 4 non-slip adhesive labels |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IP-5 |
| Dimensions | 150 mm (W) × 60 mm (D) × 5 mm (H) |
| Weight | 345 g |
| Surface Finish | Passivated stainless steel with anti-slip coating |
| Compliance | Designed for integration with NARISHIGE micromanipulators and microinjection systems |
| Accessories | Four (4) IP-series non-slip adhesive labels |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | JCM-7000 |
| Instrument Type | Desktop SEM |
| Magnification Range | 10×–100,000× (print output: 128 mm × 96 mm) |
| 24×–202,168× (on-screen display | 280 mm × 210 mm) |
| Accelerating Voltage | 5 kV, 10 kV, or 15 kV (software-selectable constant-voltage mode) |
| BSE Image Resolution | Not specified (system optimized for compositional and topographic contrast) |
| Specimen Dimensions | Ø80 mm × 50 mm (without stage夹具) |
| Detector Types | Everhart-Thornley secondary electron detector |
| Stage Motion | Motorized X/Y = ±40 mm each |
| Tilt | −15° to +45° |
| Rotation | 360° continuous |
| Vacuum Modes | High Vacuum (HV) and Low Vacuum (LV) |
| Operating System | Windows 10 |
| Data Formats | TIFF, BMP, JPEG, PNG (still) |
| Electron Source | Tungsten filament with integrated Wehnelt cap |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | M-10 |
| Manipulator Type | Pencil-style hydraulic micromanipulator |
| Fine Adjustment Travel | 10 mm |
| Coarse Adjustment Travel | 21 mm |
| Dimensions (W×D×H) | 57 × 15 × 30 mm |
| Weight | 50 g |
| Compatible Accessories | UPN-1 Pipette Holder, Universal Wrench |
| Mounting | Standard dovetail or threaded base (M3/M4) |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | M-152 |
| Coarse Travel (X/Y/Z) | 25 mm / 20 mm / 25 mm |
| Fine Adjustment Resolution | Sub-micrometer (via optional single-axis micrometer drive) |
| Dimensions (W×D×H) | 95 × 36 × 135 mm |
| Weight | 320 g |
| Standard Accessory | B-8B Spherical Joint |
| Optional Upgrade | Uniaxial Micrometer Drive (pipette-aligned axis) |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | M-3333 |
| Coarse Travel (X/Y/Z) | 40 mm / 12 mm / 30 mm |
| Fine Travel (X) | 7 mm |
| Fine Adjustment Resolution | 10 µm per division |
| Full Rotation Displacement (X-axis knob) | 250 µm |
| Dimensions (W×D×H) | 126 × 43 × 145 mm |
| Weight | 340 g |
| Included Accessories | H-13 Electrode Holder, Universal Wrench |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | M-3333 |
| Dimensions (W×D×H) | 126 × 43 × 145 mm |
| Weight | 340 g |
| Coarse Motion Range (X/Y/Z) | 40 / 12 / 30 mm |
| Fine Motion Range (X) | 7 mm |
| Minimum Step Size | 10 µm |
| Maximum Step Size | 250 µm |
| Compatible Electrode Holder | H-1 |
| Drive Mechanism | X-4 Rotational X-Block |
| Construction | Compact, Low-Profile Monoblock Design |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | M-40 |
| Travel Range (Coarse) | X 22 mm, Y 20 mm, Z 22 mm |
| Dimensions | 100 × 55 × 85 mm |
| Weight | 550 g |
| Base Type | Integrated Magnetic Mount |
| Standard Accessories | UPN-1 Pipette Holder, Universal Wrench |
| Compatibility | Universal Microscope Stage & Metallic Surgical Platforms |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | M-40B |
| Gross Travel (Coarse) | X: 22 mm, Y: 20 mm, Z: 22 mm |
| Dimensions (W × D × H) | 80 × 30 × 105 mm |
| Weight | 230 g |
| Accessories | UPN-1 Capillary Holder, Universal Wrench |
| Type | Manual Mechanical Micromanipulator |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | M-44 |
| Gross Travel (Coarse Adjustment) | 22 mm |
| Y-axis Pivot Motion | Yes |
| Z-axis Tilt Motion | Yes |
| Mounting Interface | Ø4 mm Rod |
| Compatible Accessories | H-7C Pipette Holder, UPN-1 Capillary Stand, Hex Key Wrench |
| Dimensions (W×D×H) | 65 × 25 × 50 mm |
| Weight | 70 g |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | M-44 |
| Mounting Interface | Ø4 mm rod |
| Gross Adjustment Range | 22 mm |
| Pivot Motion Axis | Y-axis |
| Tilt Motion Axis | Z-axis |
| Dimensions (W×D×H) | 65 × 25 × 50 mm |
| Weight | 70 g |
| Standard Accessories | H-7C Pipette Holder, Allen Wrench |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | M-5 |
| Travel Range (Coarse) | 45 mm |
| Dimensions (W×D×H) | 60 × 46 × 55 mm |
| Weight | 220 g |
| Included Accessory | Hex Key |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | M-5/6 |
| Z-Axis Coarse Travel | M-5: 45 mm, M-6: 80 mm |
| Dimensions (M-5) | 60 × 46 × 55 mm |
| Weight (M-5) | 220 g |
| Dimensions (M-6) | 100 × 52 × 74 mm |
| Weight (M-6) | 500 g |
| Compatible Rod Diameter | Ø10 mm or Ø12 mm |
| Included Accessory | Hex Wrench |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | MA-1 |
| Dimensions | 275 × 175 × 85 mm (W × D × H) |
| Weight | 2.8 kg |
| Distribution Type | Authorized Distributor |
| Import Status | Imported Instrument |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | MA-1 |
| Dimensions | 275 × 175 × 85 mm |
| Weight | 2.8 kg |
| Device Type | Electrode Position Calibration Instrument |
| Compliance | Designed for electrophysiology and microinjection lab environments |