PULUODY
Filter
Showing 241–270 of 412 results
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-MPCS2.0-A |
| Microscope Type | Upright |
| Image Analysis System | Integrated |
| Total Magnification Range | 40× to 1000× |
| Detection Range | 1 μm – 500 μm |
| Resolution | 0.1 μm |
| Repeatability Error | < 5% (excluding sample preparation variability) |
| CCD Camera | 3 MP |
| Calibration Accuracy | ±3% (typical) |
| Particle Segmentation Speed | < 1 s |
| Segmentation Success Rate | > 93% |
| Software Platform | Windows 2000 / XP |
| Interface | RS232 or USB |
| Compliance Standards | USP <788>, USP <789>, EP, JP, ChP 2020, GB/T 11446.9-2013, ISO 21501, ISO 21510, ASTM F312, ISO 4406 (adapted) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PLD-MPCS2.0-B |
| Price | USD 53,800 (approx.) |
| Microscope Configuration | Upright |
| Integrated Image Analysis System | Yes |
| Total Magnification Range | 40× to 1000× |
| Eyepiece | 10× |
| Objective Lenses | 10× (standard), with optional 4×, 20×, 40×, 100× oil immersion |
| Camera Resolution | 3 MP CCD |
| Optical Resolution | 0.1 µm |
| Measurement Accuracy | ±3% (typical) |
| Repeatability Error | <5% (excluding sample preparation variability) |
| Particle Detection Resolution | >95% (calibrated per ChP 2020) |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Image Segmentation Speed | <1 sec per frame |
| Segmentation Success Rate | >93% |
| Calibration Validation | Certified by Northwest National Metrology & Testing Center (Civil Products) |
| Software Compatibility | Windows 2000/XP (legacy support) |
| Analytical Outputs | Particle size distribution (1–500 µm), aspect ratio distribution, circularity distribution, particle count per volume, length-weighted mean diameter, projected area equivalent diameter |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-MPCS2.0-C |
| Microscope Type | Upright Metallurgical Microscope |
| Image Analysis System | Integrated |
| Total Magnification Range | 40× to 1000× |
| Eyepiece | 10× |
| Objective Lenses | 20× (standard), with full parfocal objective set supporting 4×, 10×, 40×, 100× oil immersion |
| Resolution | 0.1 µm |
| Measurement Accuracy | ±3% (typical, per ChP 2020 calibration) |
| Repeatability Error | <5% (excluding sample preparation variability) |
| Digital CCD Camera | 3 MP |
| Particle Detection Efficiency | >95% (per ChP 2020) |
| Particle Concentration Limit | Up to 10,000 particles/mL (5% coincidence error threshold) |
| Automatic Segmentation Speed | <1 s per field-of-view |
| Segmentation Success Rate | >93% |
| Calibration Standard Traceability | Certified by Northwest National Metrology & Testing Center (Civil Products) |
| Compliance Standards | ChP 0903 (2015/2020), USP <788>, <789>, EP 6.0–8.0, BP 2009–2013, JP 14–16, IP 2010, WHO IntPh V, GB/T 11446.9–2013, ISO 21510, ISO 11171, GB 8368 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | PLD-MPCS2.0A |
| Price | USD 42,000 (approx.) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-VZ6.0 |
| Price Range | USD 7,000 – 14,000 |
| Power Supply | 220 V ±10%, 50 Hz |
| Total Power Consumption | 2.0 kW |
| Temperature Control Range | 20 °C to 100 °C |
| Temperature Stability | ±0.01 °C |
| Sample Capacity | 2 × 12 positions |
| Timing Resolution | 0.01 s |
| Display | 10.4″ LCD touchscreen |
| Control System | Microcontroller-based digital PID control |
| Relative Humidity Limit | <85% RH |
| Compliance Standards | ASTM D445, ISO 3104, GB/T 265 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMF-2801.1 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Measurement Range | 0.1–1.0 µm (standard), customizable 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368, JJG 1061 |
| Software | V8.3 Integrated Analysis & Calibration Software (PC & Standalone Touch Interface) |
| Output | 4–20 mA Analog Signal, Optional Alarm Relay, iPad-Compatible Data Acquisition |
| Compliance Mode | Separated Civil/Military Standard Configuration |
| Display | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 Contamination Code |
| Brand | PULUODY |
|---|---|
| Model | PMT |
| Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Principle | Seventh-Generation Dual-Laser Narrow-Beam Light Obscuration |
| Measurement Standards | ISO 4406, NAS 1638, ISO 11171, ISO 11500, GB/T 14039, DL/T 432, GJB 420B |
| Particle Size Range | 2–100 µm or 4–70 µm(c) |
| Calibration Standards | ISO 4402 (ACFTD), ISO 11171 (MTD), GB/T 18854 |
| Accuracy | <3% typical |
| Channel Count | 1000 configurable size bins |
| Sample Flow Rate | 10–60 mL/min |
| Rinse Flow Rate | 20–150 mL/min |
| Operating Pressure (Online) | 0–50 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Temperature Range (Fluid) | 0–80 °C |
| Ambient Temperature | −15–50 °C |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Interface | RS232 / RS485-to-USB / native USB |
| Analog Output | 4–20 mA with programmable contamination alarm |
| Power Input | 100–265 VAC, 50–60 Hz |
| Display | Color LCD touchscreen |
| Compliance | Meets requirements for GLP/GMP traceability, FDA 21 CFR Part 11-ready software architecture (audit trail, electronic signature support in P6.4 software) |
| Brand | PULUODY |
|---|---|
| Model | PMT |
| Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Principle | Seventh-Generation Dual-Laser Narrow-Beam Light Obscuration |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Particle Size Range | 2–100 µm (or 4–70 µm(c)) |
| Channel Count | 1000 adjustable size channels (user-definable 16 channels) |
| Accuracy | <3% typical |
| Sampling Flow Rate | 10–60 mL/min |
| Cleaning Flow Rate | 20–150 mL/min |
| Max Online Pressure | 0–50 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Operating Temperature | Fluid 0–80 °C |
| Interface | RS232 / RS485 / USB |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Compliance | ISO 4406, NAS 1638, SAE AS4059D, GB/T 14039, DL/T 432, GJB 420B, MIL-STD-1246C |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.03–3000 µm (configurable sensor modules) |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368 |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Counting Resolution | Customizable channels (e.g., 1–100 µm, 4–70 µm(c), 0.1 µm(c)) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Sampling Precision | <±1% |
| Output | 4–20 mA analog signal |
| Alarm | Configurable particle concentration threshold alert |
| Data Interface | iPad-compatible wireless acquisition |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC & touchscreen) |
| Compliance | Supports 21 CFR Part 11 audit trail (optional configuration), GLP/GMP traceability mode |
| Power Input | 100–265 VAC, 50–60 Hz |
| Application Mode | Online continuous monitoring & offline portable/fixed sampling |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.03–3000 µm (sensor-configurable) |
| Calibration Standards | JJG 1061, ISO 21501, Polystyrene Latex (PSL) Spheres |
| Compliance | SJ/T 11480–2014, FZ/T 64056–2015, IEST-RP-CC004.3 |
| Sampling System | Precision Metering Piston Pump + Electromagnetic Flow Control |
| Accuracy | <±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog signal with customizable over-limit alarm |
| Data Interface | iPad-compatible wireless acquisition |
| Software | V8.3 Integrated Analysis & Calibration Separation Architecture |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-laser light scattering with narrow-beam geometry |
| Measuring Range | 0.03–3000 µm (sensor-configurable) |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368, JJG 1061 |
| Flow Control | Precision piston pump + electromagnetic flow regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog interface with customizable alarm logic |
| Data Interface | iPad-compatible wireless acquisition |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Separation Platform |
| Compliance Architecture | Dual-mode (civil/military standard support) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Measurement Range | 0.03–3000 µm (configurable sub-ranges: 1–100 µm, 4–70 µm(c), or 0.1 µm(c)) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | <±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Calibration Standards | ISO 21501-4, JJG 1061, Polystyrene Latex (PSL) Spheres |
| Compliance | SJ/T 11480–2014, FZ/T 64056–2015, IEST-RP-CC004.3 |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC & Touchscreen) |
| Data Output | Particle count per mL + ISO 4406 / NAS 1638 / SAE AS4059 contamination grading |
| Analog Output | 4–20 mA with configurable alarm threshold |
| Power Input | 100–265 VAC, 50–60 Hz |
| Interface | Color TFT LCD touchscreen + optional wireless keyboard/mouse |
| Data Acquisition | iPad-compatible real-time streaming |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 72,500 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Piston Pump + Ultra-Stable Electromagnetic Flow Regulation |
| Detection Range | 0.5–5.0 µm (standard) |
| Customizable | 1–100 µm or 4–70 µm(c) |
| Extended Sensitivity | Down to 0.1 µm(c) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368, JJG 1061 |
| Software | PULUODY V8.3 Analysis & Calibration Separation Architecture (PC & Touchscreen Integrated) |
| Interface | 4–20 mA Analog Output, Alarm Relay (Configurable) |
| Display | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Data Output | Particle Count per mL & ISO 4406 / NAS 1638 Contamination Code |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software architecture |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.03–3000 µm (configurable sub-ranges: 1–100 µm, 4–70 µm(c), or 0.1 µm(c)) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Regulation |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable Latex Spheres |
| Output | 4–20 mA analog signal,超标 alarm (customizable) |
| Data Interface | iPad-compatible wireless acquisition, PC-based V8.3 Analysis & Calibration Software Suite |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance Context | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PMT-2 |
| Price | USD 72,800 (approx. based on ¥520,000 @ 1 USD = ¥7.15) |
| Sensor Generation | 8th-generation dual-laser narrow-beam optical sensor |
| Detection Range | 0.1–0.5 µm (standard) |
| Sampling Method | Precision metering piston pump |
| Flow Control | Dual-stage — high-accuracy piston pump + ultra-precise electromagnetic flow regulator |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Error | ≤2.5% at 1000 particles/mL |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-traceable latex spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle threshold alert |
| Data Acquisition | iPad-integrated real-time acquisition |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen version) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 contamination codes |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.065–0.2 µm and 0.1–0.5 µm (standard) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 10,000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Compliance | USP <788>, USP <789>, EP 2.9.19, BP 2.9.19, ChP 2015/2020, GB 8368, ISO 21501-2, JJG 1061 |
| Output Interface | 4–20 mA analog output with configurable alarm thresholds |
| Data Acquisition | iPad-integrated wireless acquisition & PC-based V8.3 Analysis Software Suite |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Application Domain | Semiconductor photoresist, ultrapure water (UPW), electronic cleaning agents, silicon wafers, flat-panel glass, microelectronics components, nanofiltration, and polymer solutions |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 |
| Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.1–100 µm (customizable sub-ranges: 0.1 µm(c), 4–70 µm(c)) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Compliance | USP <788>, USP <789>, EP 2.9.19, BP 2.9.19, ChP 2015/2020, GB 8368, ISO 21501-4, JJG 1061 |
| Data Output | 4–20 mA analog interface, iPad-compatible wireless acquisition |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC & embedded) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | ISO 21501-2, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368 |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Measurement Range | 0.065–0.2 µm and 0.1–0.5 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±3% typical |
| Volume Accuracy | ±1% |
| Coincidence Limit | 10,000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output with configurable particle-count alarm |
| Data Acquisition | iPad-integrated wireless acquisition system |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + touchscreen GUI) |
| Display | Color LCD touch interface with optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance Mode | Separated civilian/military standard configuration |
| Regulatory Alignment | Supports 21 CFR Part 11 audit trail (software-configurable), GLP/GMP-compliant reporting templates |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.03–3000 µm (configurable) |
| Calibration Standards | JJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Reference Spheres |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Options | 4–20 mA analog signal,超标 alarm (customizable) |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC & Touchscreen GUI) |
| Compliance | Supports GLP/GMP audit trails, FDA 21 CFR Part 11–ready configuration (optional), ISO/IEC 17025 traceable calibration workflows |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | JJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Reference Spheres |
| Measurement Range | 0.1–100 µm (configurable sub-ranges: 0.1–1.0 µm, 4–70 µm(c), or user-defined 1–100 µm) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog signal + digital alarm trigger |
| Data Interface | iPad-compatible wireless acquisition |
| Software | PULUODY V8.3 Particle Analysis Suite (PC & embedded touchscreen version) |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Compliance | Supports GLP audit trails, configurable report generation per ISO 4406, NAS 1638, and SAE AS4059D |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368 |
| Measurement Range | 0.1–1.0 µm (standard), customizable 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sample Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog signal,超标 alarm (customizable) |
| Data Interface | iPad-compatible wireless acquisition |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen) |
| Compliance | Supports 21 CFR Part 11 audit trail (via optional software module), GLP/GMP-ready reporting |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 67,500 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368-2018 |
| Measurement Range | 0.1–1.0 µm (standard), customizable 1–100 µm or 4–70 µm(c) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Data Acquisition | iPad-compatible wireless telemetry & local touchscreen (color LCD) |
| Software | PULUODY V8.3 Particle Analysis Suite (PC & embedded integrated edition) |
| Compliance | Supports 21 CFR Part 11 audit trail, GLP/GMP-compliant reporting modules |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 67,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Online Laser Particle Counter |
| Measurement Range | 0.1–1.0 µm |
| Repeatability | ≤5% RSD |
| Measurement Time | 60 s per sample |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368 |
| Sample Flow Control | Precision Metering Plunger Pump + Electromagnetic Flow Regulation |
| Counting Resolution | 0.1 µm (c) minimum detectable threshold |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Analog Output | 4–20 mA |
| Data Interface | IPAD-compatible wireless acquisition system |
| Operating Voltage | 100–265 VAC, 50–60 Hz |
| Display | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 72,800 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368 |
| Measurement Range | 0.1–1.0 µm (standard), customizable 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output,超标 alarm relay (customizable) |
| Data Output | iPad-compatible wireless acquisition, touchscreen GUI + optional PC software (V8.3 Integrated Edition) |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Compliance Architecture | Separated analytical testing & metrological calibration modules |
| Regulatory Alignment | Supports FDA 21 CFR Part 11 audit trail configuration (via optional software license), GLP/GMP-compliant reporting templates |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 67,500 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Piston Pump + High-Accuracy Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368-2018 |
| Measurement Range | 0.1–0.5 µm and 0.1–1.0 µm (standard) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Interface | 4–20 mA analog output with programmable alarm thresholds |
| Data Acquisition | Integrated iPad-compatible wireless data capture |
| Software | PULUODY V8.3 Particle Analysis & Calibration Separation Platform (PC + embedded GUI) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 |
| Origin | Shaanxi, China |
| Sensor | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Detection Range | 0.1–1.0 µm & 0.1–0.5 µm |
| Customizable Range | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | <±1% |
| Measurement Accuracy | <±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output | 4–20 mA analog interface with configurable超标 alarm |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368, JJG 1061, ISO 21501-4 |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + Touchscreen UI) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.03–3000 µm (sensor-selectable) |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368, JJG 1061 |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Options | 4–20 mA analog signal,超标 alarm (customizable) |
| Data Interface | iPad-compatible wireless acquisition |
| Software | V8.3 Integrated Analysis & Calibration Separation Platform |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance Mode | Civil & Military Standard Separation Architecture |
| Application Modes | Online continuous monitoring & offline portable/fixed measurement |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Measurement Range | 0.5–5.0 µm (standard) |
| Customizable | 1–100 µm or 4–70 µm(c) |
| Extended Sensitivity | Down to 0.1 µm(c) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Calibration Standards | ISO 21501, JJG 1061, Polystyrene Latex (PSL) Spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Data Output | IPAD-based acquisition system, 4–20 mA analog interface with configurable alarm triggers |
| Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Operation Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC & embedded) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.03–3000 µm (sensor-configurable) |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368 |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog signal with customizable alarm threshold |
| Data Interface | iPad-compatible wireless acquisition |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen) |
| Compliance Support | FDA 21 CFR Part 11 audit trail ready (optional), GLP/GMP reporting modules |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.1–0.5 µm (standard) |
| Accuracy | <±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Calibration Standards | JJG 1061, ISO 21501, NIST-traceable latex spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog output with configurable alarm thresholds |
| Data Acquisition | iPad-compatible wireless data capture |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen version) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Regulatory Alignment | Supports GLP/GMP audit trails, FDA 21 CFR Part 11-compliant user authentication and electronic signature options (via software configuration) |