PULUODY
Filter
Showing 271–300 of 412 results
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Detection Range | 0.1–1.0 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Calibration Standards | ISO 21501, JJG 1061, NIST-Traceable Latex Spheres |
| Compliance | ChP 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alarm |
| Data Acquisition | iPad-integrated wireless acquisition |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + Embedded) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 contamination code |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 |
| Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Range | 0.03 µm – 3000 µm (sensor-configurable: 2–100 µm or 4–70 µm(c)) |
| Channel Count | 16 user-selectable size channels from 1000 total bins |
| Accuracy | <3% typical |
| Sampling Flow Rate | 10–60 mL/min |
| Online Pressure Range | 0–0.6 MPa (standard), up to 50 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Operating Temperature | Fluid 0–80 °C, Ambient −15–50 °C |
| Compliance Standards | ISO 4406, ISO 11171, ISO 11500, NAS 1638, GB/T 14039, DL/T 432, GJB 420B, MIL-STD-1246C |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 (1) |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (7th-Generation Dual-Laser Narrow-Beam Sensor) |
| Measurement Range | 0.03 µm to 3000 µm (sensor-configurable: 2–100 µm or 4–70 µm(c)) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Counting Channels | 1000 adjustable size bins (up to 16 user-defined channels) |
| Accuracy | <3% typical |
| Sampling Flow Rate | 10–60 mL/min |
| Cleaning Flow Rate | 20–150 mL/min |
| Operating Pressure (online) | 0–0.6 MPa (standard), 0–50 MPa (with pressure regulator) |
| Fluid Viscosity Range | Offline ≤99 mm²/s |
| Temperature Range | Fluid 0–80 °C |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Compliance Standards | ISO 4406, NAS 1638, SAE AS4059D, GB/T 14039, DL/T 432, GJB 420B, MIL-STD-1246, ISO 11500 |
| Software | P6.4 Integrated Analysis Suite (PC & embedded versions) |
| Interface | RS232 / RS485-to-USB / native USB |
| Output | 4–20 mA analog +超标 alarm (customizable) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Display | Color LCD touchscreen |
| Control | Integrated industrial PC or external IPC |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 |
| Sensor Technology | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Detection Range | 0.03–3000 µm (configurable sub-ranges: 1–100 µm, 4–70 µm(c), or 0.1 µm(c)) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501-2, NIST-traceable latex spheres |
| Output | 4–20 mA analog interface with customizable alarm thresholds |
| Data Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Analysis & Calibration Suite (PC + integrated touchscreen UI) |
| Compliance | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Plunger Pump + Ultra-Precise Electromagnetic Flow Regulation |
| Measurement Range | 0.03–3000 µm (configurable sub-ranges: 1–100 µm, 4–70 µm(c), 0.1 µm(c)) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Error | ≤2.5% at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501, Polystyrene Latex (PSL) Spheres |
| Compliance | SJ/T 11480–2014, FZ/T 64056–2015, IEST-RP-CC004.3 |
| Data Output | 4–20 mA Analog Interface with Customizable Threshold Alarm |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 Contamination Code |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + iPad-compatible) |
| Operating Interface | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Application Mode | Online Continuous Monitoring & Offline Portable/Fixed Sampling |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 72,800 (FOB Shanghai, ex-factory) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Detector |
| Flow Control | Precision Piston Pump + Ultra-Stable Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol IV, GB/T 18854-2015 |
| Measurement Range | 0.1–100 µm (user-configurable sub-ranges: 0.1–0.5 µm, 0.1–1.0 µm, 4–70 µm(c), or custom 1–100 µm) |
| Sample Volume Accuracy | ±1% |
| Counting Accuracy | ±3% typical (NIST-traceable latex standards) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Reporting Output | Particles/mL + ISO 4406 / NAS 1638 / SAE AS4059F contamination codes |
| Interface | 4–20 mA analog output,超标 alarm relay (customizable), iPad-compatible wireless data acquisition |
| Software | PULUODY V8.3 Analytical Suite (PC & tablet-native, 21 CFR Part 11-compliant audit trail, GLP/GMP-ready calibration logging) |
| Display | Color TFT touchscreen (7″) + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50/60 Hz |
| Compliance | Designed to meet IEST RP-CC004.3 Annex A (Wipe Cloth Extraction & Analysis Protocol), ASTM F3231-21, and JIS Z 8901 Class 5 particle counting requirements for cleanroom consumables validation |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measuring Range | 0.03–3000 µm (sensor-selectable) |
| Calibration Standards | JJG 1061, ISO 21501, Polystyrene Latex (PSL) Spheres |
| Compliance | SJ/T 11480–2014, FZ/T 64056–2015, IEST-RP-CC004.3 |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Sampling Accuracy | <±1% |
| Counting Accuracy | <±3% (typical) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog interface with customizable over-limit alarm |
| Data Interface | iPad-compatible wireless acquisition |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + Standalone Mode) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 / SAE AS4059 contamination codes |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-1 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Measuring Range | 0.5–5.0 µm (standard) |
| Sampling Method | Precision Metering Piston Pump + Electromagnetic Flow Control |
| Sample Volume Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable超标 alarm |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Compliance Standards | USP <788>, EP 2.9.19, BP, ChP 2015/2020, GB 8368, ISO 21501-4, JJG 1061 |
| Calibration Reference | NIST-traceable latex spheres or ISO 21501-4 compliant standards |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + iPad-compatible data acquisition) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Application Scope | Semiconductor process chemicals, ultrapure water (UPW), electronic cleaning agents, flat-panel display etchants, silicon wafers, optical glass, nanofiltration permeates, polymer solutions, injectables, and insoluble particle analysis in organic solvents |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Seventh-Generation Dual-Laser Narrow-Beam Technology |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Measurement Range | 2–100 µm or 4–70 µm(c) |
| Channel Count | 1000 adjustable size channels (up to 16 user-defined bins) |
| Accuracy | <3% typical |
| Sample Flow Rate | 10–60 mL/min |
| Cleaning Flow Rate | 20–150 mL/min |
| Operating Pressure (Online) | 0–50 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Temperature Range | Fluid 0–80°C |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Compliance | ISO 4406, NAS 1638, SAE AS4059D, GB/T 14039, DL/T 432, GJB 420B, MIL-STD-1246C |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-11 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Piston Pump + Ultra-Precise Electromagnetic Flow Control System |
| Detection Range | 0.1–0.5 µm, 0.2–2.0 µm (standard) |
| Customizable | 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Accuracy | < ±1% |
| Measurement Accuracy | < ±5% (typical) |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Threshold-based particle count alarm (customizable) |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination等级 |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, ISO 21501-2 compliant |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC & touchscreen versions) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Application Scope | Ultrapure water (UPW), semiconductor process chemicals, electronic cleaning agents, silicon wafers, flat-panel display substrates, optical lenses, nanofiltration membranes, microfiltration systems, polymer solutions, and insoluble particulate analysis in organic solvents |
| Brand | PULUODY |
|---|---|
| Model | PMT-2-12 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.1–0.5 µm and 0.2–2.0 µm (standard) |
| minimum detectable size | 0.1 µm(c) |
| Sampling Method | Precision Piston Pump with Electromagnetic Flow Control |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | ±5% typical |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Output | 4–20 mA analog signal with configurable超标 alarm |
| Data Interface | iPad-compatible wireless acquisition system |
| Calibration Standards | JJG 1061, ISO 21501-2, or NIST-traceable latex sphere reference |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen version) |
| Display | Color LCD touch interface + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2-13 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | JJG 1061, ISO 21501-2, Polystyrene Latex (PSL) Reference Spheres |
| Detection Range | 0.1–0.5 µm & 0.2–2.0 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-stage electromagnetic + mechanical precision regulation |
| Sample Volume Accuracy | < ±1% |
| Counting Accuracy | ±5% typical (NIST-traceable validation) |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 / SAE AS4059 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC + embedded touchscreen UI) |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2-14 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Plunger Pump + High-Accuracy Electromagnetic Flow Regulation |
| Calibration Standards | JJG 1061, ISO 21501-2, Polystyrene Latex (PSL) Reference Spheres |
| Measurement Range | 0.1–0.5 µm, 0.2–2.0 µm |
| Customizable Ranges | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | ±5% typical |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Reporting Modes | Particles per mL & ISO 4406 / NAS 1638 contamination code |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software Platform | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + Embedded Touch UI) |
| Operating Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Brand | PULUODY |
|---|---|
| Model | PMT-2-2 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.5–5.0 µm (standard) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | ISO 21501, JJG 1061, NIST-traceable latex spheres |
| Compliance | ChP 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog output with configurable alarm triggers |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Control Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC & embedded) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-3 |
| Price | USD 31,800 (FOB) |
| Detection Principle | Light Obscuration (LO) per ISO 11500 & ASTM F312-22 |
| Laser Sensor | 7th-generation dual-laser narrow-beam photodetector |
| Calibration Standards | ISO 4402 (ACFTD), ISO 11171 (MTD), GB/T 18854 |
| Measuring Range | 0.03 µm to 3000 µm (with selectable channels: 2–100 µm or 4–70 µm(c)) |
| Accuracy | <3% typical |
| Channel Count | 1000 configurable size bins |
| Sample Flow Rate | 10–60 mL/min |
| Cleaning Flow Rate | 20–150 mL/min |
| Operating Pressure (Online) | 0–50 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Fluid Temperature | 0–80 °C |
| Ambient Temperature | −15–50 °C |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Compliance | ISO 4406:1999/2017, NAS 1638, SAE AS4059D, GB/T 14039, DL/T 432, GJB 420B, MIL-STD-1246C, ISO 11171, ISO 11500 |
| Software | P6.4 Analytical Testing Suite (Integrated Industrial PC & Standalone PC Edition) |
| Interface | RS232 / RS485-to-USB / Native USB |
| Output | 4–20 mA analog +超标 alarm relay (customizable) |
| Display | Color LCD touchscreen |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-31 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Measuring Range | 0.1–1.0 µm & 0.2–2.0 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-stage electromagnetic + precision piston pump |
| Accuracy | ±5% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Output | 4–20 mA analog interface with configurable particle exceedance alarm |
| Reporting | Particles per mL and ISO 4406 / NAS 1638 / SAE AS4059 contamination codes |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, ISO 21501-2 compliant |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | PMT-2-33 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Detector |
| Measurement Range | 0.1–1.0 µm & 0.2–2.0 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Piston Pump Regulation |
| Accuracy | ±5% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Calibration Standards | JJG 1061, ISO 21501-2, NIST-traceable latex spheres |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + touchscreen UI) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance Support | GLP/GMP audit trail capability, FDA 21 CFR Part 11–ready software architecture (user roles, electronic signatures, data integrity logging) |
| Brand | PULUODY |
|---|---|
| Model | PMT-2-4 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–100 µm (configurable sub-ranges: 0.1–1.0 µm, 0.2–2.0 µm, 0.5–5.0 µm, 0.5–20.0 µm, 4–70 µm(c)) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501, JJG 1061, NIST-traceable Latex Spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog output,超标 alarm (customizable) |
| Data Acquisition | iPad-integrated wireless acquisition |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Application Domain | High-purity acidic/alkaline process liquids, semiconductor CMP slurries, ultrapure water (UPW), electronic cleaning agents, photovoltaic etchants, TFT-LCD rinse solutions |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2-41 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | JJG 1061, ISO 21501-2, Polystyrene Latex (PSL) Spheres |
| Measurement Range | 0.1–1.0 µm, 0.2–2.0 µm, 0.5–5.0 µm (customizable from 1–100 µm or 4–70 µm(c) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | ±5% typical |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Output Interface | 4–20 mA analog output with customizable alarm trigger |
| Data Acquisition | iPad-integrated real-time acquisition |
| Software | V8.3 Integrated Analysis & Calibration Software (PC & Standalone Mode) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 / SAE AS4059 contamination grade classification |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-8 |
| Price | USD 31,500 (FOB) |
| Detection Principle | Light Obscuration (7th-Generation Dual-Laser Narrow-Beam Sensor) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Measurement Range | 0.03 µm – 3000 µm (with configurable channels: 2–100 µm or 4–70 µm(c)) |
| Channel Count | 1000 adjustable size bins |
| Accuracy | <3% typical |
| Sample Flow Rate | 10–60 mL/min |
| Cleaning Flow Rate | 20–150 mL/min |
| Operating Pressure (Online) | 0–50 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Temperature Range | Fluid 0–80 °C |
| Data Storage | ≥20,000 test records (expandable via USB drive) |
| Compliance | ISO 4406, NAS 1638, SAE AS4059D, DL/T 432, GB/T 14039, GJB 420B, MIL-STD-1246C |
| Software | P6.4 Integrated Analysis Suite (PC & embedded versions) |
| Interface | RS232 / RS485-to-USB / native USB |
| Output | 4–20 mA analog +超标 alarm (customizable) |
| Display | Color TFT touchscreen (integrated industrial PC or external IPC option) |
| Brand | PULUODY |
|---|---|
| Model | PMT-2-C |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Measuring Range | 0.05–0.2 µm, 0.1–0.5 µm (standard) |
| Sampling Method | Precision Metering Piston Pump + Electromagnetic Flow Control |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Data Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination code |
| Compliance Standards | JJG 1061, ISO 21501-4, USP <788>, EP 2.9.19 |
| Software Platform | V8.3 Integrated Analysis & Calibration Software (PC + touchscreen UI) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-D |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.5–20.0 µm (standard) |
| Sampling Method | Precision Piston Pump with Electromagnetic Flow Control |
| Accuracy | <±1% volumetric sampling error |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368, JJG 1061 |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + Standalone Touch Interface) |
| Output | 4–20 mA analog signal,超标 alarm relay (customizable), iPad-compatible data acquisition |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 contamination codes |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-E |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Sensor |
| Measurement Range | 0.1–1.0 µm (standard), customizable 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501, JJG 1061, Latex Sphere Reference, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368 |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + Touchscreen GUI) |
| Data Output | iPad-compatible Wireless Acquisition, 4–20 mA Analog Output, Real-time Alert Interface |
| Compliance Support | FDA 21 CFR Part 11 Audit Trail Ready (via optional software module), GLP/GMP Traceable Reporting |
| Power Input | 100–265 VAC, 50–60 Hz |
| Key | Brand: PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory Laser Particle Counter |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1–1.0 µm |
| Repeatability | ±3% |
| Measurement Time | 60 s |
| Sensor Generation | 8th-Gen Dual-Laser Narrow-Beam Detector |
| Calibration Standards | ISO 21501-2, USP <788>, EP 2.9.19, ChP 2020, GB 8368 |
| Data Output | Particles/mL & ISO 4406 / NAS 1638 Contamination Codes |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | 10,000 particles/mL (2.5% coincidence error) |
| Analog Output | 4–20 mA with customizable alarm threshold |
| Operating Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis Suite (PC & embedded) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2-H |
| Price | USD 72,800 (approx.) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Counter |
| Measurement Range | 0.5–5.0 µm |
| Repeatability | ≤3% RSD |
| Measurement Time | 60 s per sample |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368 |
| Flow Control | Precision Metering Plunger Pump + Ultra-Stable Electromagnetic Flow Regulation |
| Sample Interface | 4–20 mA Analog Output |
| Data Acquisition | iPad-Compatible Wireless Interface |
| Operating Interface | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Reporting Units | Particles/mL & ISO 4406 / NAS 1638 Contamination Codes |
| Voltage Input | 100–265 VAC, 50–60 Hz |
| Counting Accuracy | <±1% volumetric error |
| coincidence limit | 1000 particles/mL (≤2.5% coincidence error) |
| Brand | PULUODY |
|---|---|
| Model | PMT-2-J |
| Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.065–0.2 µm & 0.1–0.5 µm (customizable to 1–100 µm or 4–70 µm(c)) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 10,000 particles/mL (2.5% coincidence error) |
| Calibration Standards | ISO 21501-2, JJG 1061, Latex Spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP, BP, GB 8368 |
| Output Interface | 4–20 mA analog output with configurable alarm trigger |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + touchscreen GUI) |
| Operation | 7-inch color LCD touchscreen + optional wireless keyboard/mouse |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2-K |
| Price | USD 34,800 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Counter |
| Measurement Range | 2–750 µm |
| Repeatability | ≤5% RSD |
| Measurement Time | 60 s per sample |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Software Version | V8.3 Integrated Analysis & Calibration Suite (PC + Touchscreen) |
| Sampling Accuracy | <±1% |
| Size Accuracy | <±3% (typ.) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output with customizable over-limit alarm |
| Reporting | Particles/mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Model | PMT-2-O |
| Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Measurement Range | 0.05–0.2 µm, 0.1–0.5 µm, 0.2–2.0 µm (customizable from 0.1 µm to 100 µm) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±5% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Output | 4–20 mA analog signal with configurable alarm thresholds |
| Calibration Standards | JJG 1061, ISO 21501-2, NIST-traceable latex spheres |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO 14644-1/2 cleanroom water monitoring, SEMI F57/F63, ASTM D6978, USP <788> & <789>, and GLP/GMP-aligned data integrity workflows |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-r |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.5–5.0 µm (standard) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501, JJG 1061, Latex Spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog output with configurable alarm triggers |
| Data Acquisition | iPad-integrated wireless collection |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC version) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PMT-2-S |
| Price | USD 53,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Counter |
| Measurement Range | 1–450 µm |
| Repeatability | ≤5% RSD |
| Measurement Time | ≤60 s |