Specim
Filter
Showing all 10 results
| Brand | Specim |
|---|---|
| Origin | Finland |
| Model | AISA |
| Imaging Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based and airborne (fixed-wing, rotary-wing, manned & unmanned aircraft) |
| Spectral Range | 400–1000 nm (VNIR), 600–1600 nm (VNIR-SWIR overlap), 400–2500 nm (full VNIR-SWIR), 7.7–12.3 µm (LWIR) |
| Spectral Resolution | 1.75 nm / 3.5 nm / 7 nm (VNIR), 10 nm / 15 nm (SWIR), 100 nm (LWIR) |
| Spatial Pixels | 2048 (VNIR), 384–1024 (SWIR variants), 616 (LWIR) |
| Field of View (TFOV) | 32° |
| Instantaneous Field of View (IFOV) | Height-dependent |
| Frame Rate | ≥100 fps |
| Brand | SPECIM |
|---|---|
| Origin | Finland |
| Model | ArtScanner |
| Spectral Ranges | VNIR (400–1000 nm), NIR (900–1700 nm), SWIR (1000–2500 nm) |
| Maximum Scan Length | 190 cm |
| Illumination Source | Broadband Halogen Lamp (400–2500 nm) |
| Camera Mounting | Easy-Lock Modular Interface |
| Compatible Platform | Fully Interoperable with SisuCHEMA Hyperspectral Data Acquisition Suite |
| Brand | SPECIM |
|---|---|
| Origin | Finland |
| Camera Type | Push-broom imaging spectrometer |
| Optical Design | Dispersive (transmissive prism-grating) |
| Mounting Flexibility | Ground-based & airborne deployment |
| Spectral Ranges | 400–1000 nm (FX10), 900–1700 nm (FX17), 960–2500 nm (SX25), 2.7–5.3 µm (FX50), 7.7–12.3 µm (FX120) |
| Spectral Resolution | 5.5 nm (FX10), 8 nm (FX17, SX25), 35 nm (FX10 – alternate specification) |
| Spatial Pixel Count | 1024 (FX10), 640 (FX17, FX50, SX25), 616 (FX120) |
| Pixel Size | 8 × 8 µm (FX10), 15 × 15 µm (FX17) |
| Field of View (TFOV) | 38° |
| Instantaneous Field of View (IFOV) | Configurable per lens |
| Frame Rate | 330 Hz (FX10 full spectrum), 670 Hz (FX17 full spectrum), 380 Hz (FX50), 162 Hz (SX25), 240 Hz (FX120) |
| Interface | GigE Vision & Camera Link |
| Calibration | Factory-applied spectral and radiometric calibration traceable to NIST standards |
| Operating Temperature | Thermally stabilized optics with internal non-uniformity correction |
| Brand | SPECIM |
|---|---|
| Origin | Finland |
| Model | FX50 |
| Operating Principle | Push-broom |
| Imaging Optics | Binary optical elements |
| Deployment | Ground-based |
| Spectral Range | 2.7–5.3 µm |
| Spectral Resolution | 35 nm |
| Field of View (TFOV) | 24°, 45°, or 60° |
| Frame Rate | 380 fps |
| Interface | GigE Vision |
| Calibration | Factory-performed spectral and radiometric calibration |
| Thermal Stability | Actively temperature-stabilized optics |
| Spatial Resolution | Not specified (system-dependent on lens and working distance) |
| Compliance | Designed for industrial automation environments |
| Brand | SPECIM |
|---|---|
| Country of Origin | Finland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Range | Multiple Models (IQ, FX10/FX17/SX25/FX50/FX120, SWIR) |
| Price Range | USD 42,000 – 70,000 (approx.) |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive (prism/grating-based) |
| Deployment Modes | Ground-based & Airborne |
| Spectral Coverage | UV to LWIR (200 nm – 12.3 µm) |
| Spectral Resolution | 5.5 nm – 100 nm |
| Spatial Pixels | 384 – 1024 px |
| Frame Rate | 162 Hz – 670 Hz |
| FOV | Model-dependent |
| IFOV | Configurable via lens selection |
| Cooling | Thermoelectric (SWIR, MWIR, LWIR models) |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Specim |
|---|---|
| Origin | Finland |
| Model | SPECIM IQ |
| Working Principle | Push-broom |
| Imaging Method | Dispersive |
| Operational Mode | Ground-based & Airborne Compatible |
| Spectral Range | VNIR 400–1000 nm (CMOS sensor) |
| Spectral Resolution | 3 nm |
| Field of View (TFOV) | 0.5 × 0.5 m at 1 m distance |
| Instantaneous Field of View (IFOV) | 512 pixels |
| Weight | 1.3 kg |
| Integrated Components | Onboard touchscreen, rechargeable battery, SD card storage, embedded acquisition & processing software |
| Brand | SPECIM |
|---|---|
| Origin | Finland |
| Model | SisuCHEMA |
| Imaging Principle | Pushbroom |
| Imaging Method | Dispersive |
| Operational Mode | Ground-based |
| Spectral Ranges | 400–1000 nm, 900–1700 nm, 1000–2500 nm |
| Spectral Resolution | ≥1 nm |
| Spatial Resolution Options | 1024 × n, 2048 × n pixels |
| Field of View (TFOV) | 23°, 32°, 40° |
| Instantaneous Field of View (IFOV) | Configurable per lens (e.g., 0.1–0.5 mrad) |
| Frame Rate | >100 fps |
| Brand | SPECIM |
|---|---|
| Origin | Finland |
| Model | SisuROCK |
| Imaging Principle | Push-broom |
| Imaging Type | Dispersive |
| Operational Mode | Ground-based |
| Spectral Range | 100–1000 nm (VNIR), 1000–2500 nm (SWIR), 3–5 µm (MWIR), 8–12 µm (LWIR) |
| Spectral Resolution | ≥1 nm |
| Spatial Resolution | 1024 × 1024 or 2048 × 2048 pixels |
| Field of View (TFOV) | 23° or 32° |
| Instantaneous Field of View (IFOV) | Height-dependent |
| Frame Rate | >1000 fps |
| Brand | SPECIM |
|---|---|
| Country of Origin | Finland |
| Model | SpecimONE |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Deployment | Ground-based |
| Spectral Range | 400–1000 nm (FX10) |
| Spectral Resolution | 35 nm (FX10) |
| Spatial Resolution | 8 × 8 µm (FX10) |
| Field of View (TFOV) | 38° |
| Instantaneous Field of View (IFOV) | 640 pixels (FX50) |
| Frame Rate | 380 Hz (FX50, full spectrum) |
| Camera Interface | CameraLink (SDR) |
| Real-time Processing Unit | SpecimCUBE (NVIDIA Jetson AGX Xavier) |
| Data Output | GigE Vision (RGB8, Mono12, Mono12Packed) |
| Compliance | CE, FCC, RoHS 3 |
| Operating Temperature | −10 °C to +60 °C |
| Humidity | 95% RH at 40 °C (non-condensing) |
| Power Input | 9–36 V DC |
| Dimensions (W × L × H) | 190 × 300 × 90 mm |
| Weight | 4.6 kg |
| Brand | Specim |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Specim SWIR |
| Pricing | Upon Request |
| Operating Principle | Push-broom |
| Imaging Mode | 3D (hyperspectral data cube) |
| Deployment | Ground-based |
| Spectral Range | 1000–2500 nm |
| Spectral Resolution | 10 nm (with 30 µm slit) |