Carbon Dioxide Analyzer Carbon Monoxide Analyzer
Filter
Showing 91–120 of 210 results
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Detection Targets | NOx, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5 / 0–10 / 0–25 vol% (for CO₂ and O₂) |
| Repeatability | ±1.0% FS |
| Response Time (T90) | ≤45 s (all gases except SO₂: ≤180 s) |
| Zero/ Span Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Linearity Error | ±2.0% FS |
| Sample Flow Rate | ~0.5 L/min |
| Display | Color LCD touchscreen with real-time trend plotting |
| Data Storage | SD card (user-configurable interval) |
| Output | 4–20 mA analog, Ethernet |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 (PG-300 Series) |
| Instrument Type | Portable |
| Measured Gases | NOₓ, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5 / 10 / 25 vol% (CO₂, O₂) |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (±2.0% F.S./day for SO₂) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (all gases except SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Compliance | UK MCERTS, EU TÜV, US EPA ETV, China CMA, Korea KOLAS, Japan JIS/MI |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOx, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5 / 0–10 / 0–25 vol% (CO₂, O₂) |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (±2.0% F.S./day for SO₂) |
| Linearity | ±2.0% F.S. |
| Response Time (T90) | ≤45 s (all gases except SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Dimensions | 226 × 265 × 510 mm (W × H × D) |
| Weight | ~14 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Compliance | MCERTS (UK), TÜV (EU), GOST (Russia), ETV (US), China Metrology Certification, KOLAS (Korea), JIS (Japan) |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Preheat Time | 30 min (±2.0% F.S. stability achieved within 2 h) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOₓ, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5 / 0–10 / 0–25 vol% (CO₂, O₂) |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (all gases except SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W × H × D) |
| Weight | ~14 kg |
| Compliance | UK MCERTS, EU TÜV, US EPA ETV, China CMA, KR KOLAS, JP JIS/JCSS |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Detection Targets | NOₓ, SO₂, CO, CO₂, O₂ |
| Measurement Principle | Pulsed Flow Modulation Chemiluminescence (NOₓ), Pulsed Flow Modulation NDIR (SO₂, CO, CH₄), Broadband NDIR (CO₂), Galvanic Cell (O₂) |
| Range Options | NOₓ: 0–25 to 2500 ppm (7 ranges) |
| SO₂ | 0–200 to 3000 ppm (4 ranges) |
| CO | 0–200 to 5000 ppm (5 ranges) |
| CO₂ | 0–10 to 30 vol% |
| O₂ | 0–5 to 25 vol% |
| CH₄ | 0–2000/5000 ppm |
| Repeatability | ±1.0% FS |
| Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Linearity | ±2.0% FS |
| Response Time (T₉₀) | ≤45 s (SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Certifications | TÜV (EU), MCERTS (UK), GOST-R (Russia), ETV (USA), China Metrology Certification (CMC), Korea KOLAS, Japan JIS/JCSS |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOx, SO₂, CO, CO₂, O₂ |
| Range Options | NOx: 0–25/50/100/250/500/1000/2500 ppm (7 ranges) |
| SO₂ | 0–200/500/1000/3000 ppm (4 ranges) |
| CO | 0–200/500/1000/2000/5000 ppm (5 ranges) |
| CO₂ | 0–10/20/30 vol% (3 ranges) |
| O₂ | 0–5/10/25 vol% (3 ranges) |
| Repeatability | ±1.0% FS |
| Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Linearity | ±2.0% FS |
| Response Time (T90) | ≤45 s (SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Display | Color TFT LCD with touch interface |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Compliance | MCERTS (UK), TÜV (EU), GOST (Russia), ETV (US), China Metrology Certification, KOLAS (Korea), JIS (Japan) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Detection Targets | NOx, SO₂, CO, CO₂, O₂ (optional CH₄) |
| Range Options | 0–5 / 10 / 25 vol% (CO₂, O₂) |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Response Time (T90) | ≤45 s (all gases except SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Certifications | UK MCERTS, EU TÜV, US EPA ETV, China CMA, Korea KOLAS, Japan JIS/JCSS |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOx, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5 / 10 / 25 vol% (CO₂, O₂) |
| Repeatability | ±1.0% FS |
| Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Linearity | ±2.0% FS |
| Response Time (T90) | ≤45 s (all gases except SO₂: ≤180 s) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Weight | ~14 kg |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Compliance | UK MCERTS, EU TÜV, US EPA ETV, China CMA, KR KOLAS, JP JIS/JCSS |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOₓ, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5 / 0–10 / 0–25 vol% (CO₂, O₂) |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (±2.0% F.S./day for SO₂) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (all gases except SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Dimensions | 226 × 265 × 510 mm (W × H × D) |
| Weight | ~14 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 Series |
| Instrument Type | Portable |
| Measured Gases | NOx, SO₂, CO, CO₂, O₂ |
| Minimum Range | 0–5/10/25 vol% (O₂/CO₂) |
| Repeatability | ±1.0% F.S. |
| Response Time (T90) | ≤45 s (all gases except SO₂) |
| Zero/ Span Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity Error | ±2.0% F.S. |
| Sample Flow Rate | ~0.5 L/min |
| Display | Color TFT Touchscreen with Real-Time Trend Plotting |
| Data Storage | SD Card (User-Configurable Interval) |
| Output | 4–20 mA DC, Ethernet |
| Warm-up Time | ≤30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Certifications | TÜV (EU), MCERTS (UK), GOST-R (Russia), ETV (USA), CNAS/CMA (China), KOLAS (Korea), JIS (Japan) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOx, SO₂, CO, CO₂, O₂ |
| Range Options | 0–5/10/25 vol% (O₂, CO₂) |
| Repeatability | ±1.0% F.S. |
| Response Time (T90) | ≤45 s (all gases except SO₂) |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Sample Flow Rate | ~0.5 L/min |
| Display | Color TFT Touchscreen with Real-Time Trend Plotting |
| Data Storage | SD Card (User-Configurable Interval) |
| Output Interfaces | 4–20 mA DC, Ethernet |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Certifications | TÜV (EU), MCERTS (UK), GOST-R (Russia), ETV (USA), CNAS/CMA (China), KOLAS (Korea), JIS (Japan) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model Series | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOₓ, SO₂, CO, CO₂, O₂ (optional CH₄) |
| Range Options | NOₓ: 0–25 to 2500 ppm (7 ranges) |
| SO₂ | 0–200 to 3000 ppm (4 ranges) |
| CO | 0–200 to 5000 ppm (5 ranges) |
| CO₂ | 0–10 to 30 vol% |
| O₂ | 0–5 to 25 vol% |
| CH₄ | 0–2000/5000 ppm |
| Repeatability | ±1.0% F.S. |
| Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity | ±2.0% F.S. |
| Response Time (T₉₀) | ≤45 s (all gases except SO₂) |
| SO₂ | ≤180 s |
| Sample Flow Rate | ~0.5 L/min |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Compliance | MCERTS (UK), TÜV (EU), GOST (Russia), EPA ETV (US), CNAS/CMA (China), KOLAS (Korea), JIS/MLIT (Japan) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model Series | PG-350 |
| Instrument Type | Portable |
| Measured Gases | NOₓ, SO₂, CO, CO₂, O₂ |
| Range Options | O₂: 0–5/10/25 vol% |
| CO₂ | 0–5/10/25 vol% |
| Repeatability | ±1.0% F.S. |
| Response Time (T₉₀) | ≤45 s (all gases except SO₂) |
| Zero/Span Drift | ±1.0% F.S./day (SO₂: ±2.0% F.S./day) |
| Linearity Error | ±2.0% F.S. |
| Sample Flow Rate | ~0.5 L/min |
| Display | Color TFT-LCD Touchscreen with Real-Time Trend Graphs |
| Data Storage | SD Card (User-Configurable Interval) |
| Output Interfaces | 4–20 mA Analog, Ethernet |
| Warm-up Time | ≤30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Compliance | MCERTS (UK), TÜV (EU), GOST-R (Russia), EPA ETV (US), CNAS/CMA (China), KOLAS (Korea), JIS (Japan) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PG-350 Series |
| Instrument Type | Portable |
| Measured Gases | NOₓ, SO₂, CO, CO₂, O₂ |
| Measurement Principles | Pulsed Chemiluminescence (NOₓ), Modulated NDIR (SO₂, CO, CH₄), Broadband NDIR (CO₂), Galvanic Cell (O₂) |
| Range Options | 0–5/10/25 vol% (O₂, CO₂) |
| Repeatability | ±1.0% FS |
| Drift | ±1.0% FS/day (SO₂: ±2.0% FS/day) |
| Linearity | ±2.0% FS |
| T₉₀ Response Time | ≤45 s (all gases except SO₂) |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | 30 min |
| Operating Environment | 5–40 °C, ≤85% RH |
| Dimensions | 226 × 265 × 510 mm (W×H×D) |
| Weight | ~14 kg |
| Data Storage | SD card (user-configurable interval) |
| Outputs | 4–20 mA analog, Ethernet |
| Certifications | TÜV (EU), MCERTS (UK), GOST-R (Russia), ETV (USA), CNAS/CMA (China), KOLAS (Korea), JIS (Japan) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PMA-51d |
| Explosion Protection | Ex d IIB+H2 T4 / Ex px d IIC T4X |
| Measurement Principle | Magnetic Mechanical (Magnetic Dumbbell Ball Method) |
| Target Gas | O₂ |
| Range Options | 0–5 vol% to 0–100 vol% O₂ |
| Repeatability | ±0.1 vol% O₂ (standard range) |
| Linearity | ±1.0% F.S. |
| Zero Drift | ±0.05 vol% O₂/week |
| Span Drift | ±0.05 vol% O₂/week |
| Response Time (T90) | ≤20 s |
| Sample Flow Rate | 300 mL/min |
| Sample Pressure | ≥1.98 kPa |
| Ambient Operating Temperature | –10 to +50 °C |
| Wetted Materials | SUS304, SUS316, Pt, Borosilicate Glass, FKM, SiO₂, Au |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | TIA-51d / TIA-51p |
| Explosion Protection | Ex d IIB+H2 T4 / Ex px d IIC T4X |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measured Gases | Carbon Dioxide (CO₂), Carbon Monoxide (CO) |
| Measurement Range (CO₂) | 0–10 vol% to 0–100 vol% (configurable) |
| Measurement Range (CO) | 0–50 ppm to 0–10,000 ppm (configurable) |
| Repeatability | ±0.5% FS (standard range) |
| Linearity | ±1.0% FS |
| Zero Drift | ±1.0% FS/week |
| Span Drift | ±2.0% FS/week |
| Response Time (T90) | ≤20 s |
| Sample Flow Rate | 500 mL/min (TIA-51d), 1.5 L/min (TIA-51p) |
| Sample Pressure | ≥1.98 kPa (TIA-51d), 14.7–24.5 kPa (TIA-51p) |
| Ambient Operating Temperature | –10 to +50 °C |
| Wetted Materials | SUS304, SUS316, FKM, fused silica, gold-coated optics |
| Compliance | IEC 60079-0, IEC 60079-1 (Ex d), IEC 60079-2 (Ex p), ATEX Directive 2014/34/EU, IECEx Scheme |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TIA-51d / TIA-51p |
| Pricing | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 / VS-3000 |
| Instrument Type | Online Gas Analyzer |
| Target Gases | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂ |
| Minimum Range | 1–5 ppm |
| Repeatability | ±0.5% of Full Scale |
| Resolution | 0.1 ppm |
| Response Time (T90) | ≤30 s |
| Zero Drift | ±2.0% of Full Scale per Week |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 / VS-3000 |
| Instrument Type | In-situ Continuous Emission Monitoring (CEM) System |
| Detection Principle | Non-Dispersive Infrared (NDIR), Chemiluminescence (CLA), Magnetic Pressure (MPA), Electrochemical (Galvanic), Zirconia Oxide |
| Target Gases | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂ |
| Minimum Detectable Range | 1–5 ppm |
| Repeatability | ±0.5% FS |
| Linearity | ±1.0% FS (≤10× span) |
| Zero Drift | ±2.0% FS/week (NDIR/CLA/MPA/ZrO₂) |
| Span Drift | ±2.0% FS/week (NDIR/CLA/MPA/ZrO₂) |
| Response Time | T₉₀ ≤ 30 s (single-component mode, from analyzer inlet) |
| Resolution | 0.1 ppm (for ppm-range gases) |
| Analog Outputs | DC 0–1 V (non-isolated), DC 4–20 mA (optional) |
| Digital Interface | RS-232C |
| Sample Flow Rate | 0.5 L/min (analyzer) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Power Consumption | ~200 VA (VA-3000) |
| Dimensions (VA-3000) | 430 mm W × 132 mm H × 550 mm D |
| Weight (VA-3000) | ~20 kg |
| Enclosure | 19-inch rack-mountable chassis |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000, VS-3000 |
| Instrument Type | Portable & Rack-Mountable |
| Detection Targets | CO, CO₂, N₂O, CH₄, SO₂, NOₓ, O₂ (MPA/Galvanic/Zirconia), H₂ (MPA) |
| Minimum Range | 1–20 ppm |
| Repeatability | ±0.5% F.S. |
| Resolution | 0.1 ppm |
| Response Time (T90) | ≤30 sec |
| Zero Drift | ±2.0% F.S./week (excluding galvanic cells) |
| Span Drift | ±2.0% F.S./week (excluding galvanic cells) |
| Linearity Error | ±1.0% F.S. |
| Sampling Flow Rate | 0.5 L/min (analyzer), 1.5–5.0 L/min (preconditioning unit) |
| Warm-up Time | ~20 min (NDIR, galvanic), ~40 min (zirconia), ~60 min (CLA, MPA) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 100–450 VA |
| Display | 320 × 240 pixel LCD (111.2 mm × 89.38 mm) |
| Enclosure | 19-inch rack-mount chassis |
| Dimensions (VA-3000) | 430 mm (W) × 132 mm (H) × 500 mm (D) |
| (VS-3000) | 430 mm (W) × 221 mm (H) × 550 mm (D) |
| Weight | ~14–20 kg |
| Operating Environment | 0–40 °C, ≤90% RH |
| Sample Gas Requirements | Particulates ≤0.1 mg/m³, Dew Point ≤60 °C, Pressure Variation ±980 Pa |
| Wetted Materials | SUS, PP, PVC, PVDF, PTFE, FKM, CR, Glass |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000, VS-3000 |
| Instrument Type | Portable / Rack-Mountable |
| Detection Targets | Multi-component (CO, CO₂, N₂O, CH₄, SO₂, NOₓ, O₂, H₂, H₂S, etc.) |
| Minimum Range | 1–20 ppm |
| Repeatability | ±0.5% F.S. |
| Resolution | 0.1 ppm |
| Response Time | T90 ≤ 30 s |
| Zero Drift | ±2.0% F.S./week (excluding galvanic cells) |
| Span Drift | ±2.0% F.S./week (excluding galvanic cells) |
| Linearity Error | ±1.0% F.S. |
| Sampling Flow Rate | 0.5 L/min (analyzer), 1.5–5.0 L/min (preconditioning unit) |
| Warm-up Time | ~20 min (NDIR, galvanic), ~40 min (zirconia), ~60 min (CLA, MPA) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 100–450 VA |
| Display | 320 × 240 pixel LCD (111.2 mm × 89.38 mm) |
| Enclosure | 19-inch rack-mount chassis |
| Dimensions (VA-3000) | 430 mm (W) × 132 mm (H) × 500 mm (D) |
| Dimensions (VS-3000) | 430 mm (W) × 221 mm (H) × 550 mm (D) |
| Weight | ~14–20 kg |
| Operating Environment | 0–40 °C, ≤90% RH |
| Sample Gas Conditions | Particulates ≤0.1 mg/m³, Dew Point ≤60 °C, Pressure Fluctuation ±980 Pa |
| Wetted Materials | SUS, PP, PVC, PVDF, PTFE, FKM, CR, Glass |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 (Analyzer Unit) / VS-3000 (Sampling System) |
| Detection Principles | NDIR, CLA, MPA, Electrochemical, Zirconia |
| Measurable Gases | CO, CO₂, NOₓ, SO₂, CH₄, C₂H₄, N₂O, O₂ |
| Accuracy | ±0.5% F.S. (repeatability), ±1.0% F.S. (linearity), ±2.0% F.S./week (drift) |
| Response Time | T90 ≤ 30 s (single component) |
| Analog Outputs | 0–1 V DC, 4–20 mA (optional) |
| Communication | RS-232C |
| Operating Temperature | 0–40 °C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (VA-3000) | 430 × 132 × 550 mm (W×H×D) |
| Weight (VA-3000) | ~20 kg |
| Compliance | Designed for ISO/IEC 17025-aligned operation, compatible with EPA Method TO-15 & ASTM D6348 preconditions |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 / VS-3000 |
| Instrument Type | Online Continuous Emission Monitor (CEM) |
| Detection Principle | NDIR, CLA, MPA, Electrochemical, Zirconia |
| Measurable Gases | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂ |
| Minimum Detectable Range | 1–5 ppm |
| Repeatability | ±0.5% of Full Scale (FS) |
| Resolution | 0.1 ppm |
| Response Time (T90) | ≤30 s |
| Zero Drift | ±2.0% FS/week |
| Warm-up Time | 20–60 min (varies by sensor type) |
| Analog Output | DC 0–1 V / 4–20 mA |
| Digital Interface | RS-232C |
| Sample Flow Rate | ~0.5 L/min |
| Operating Environment | 0–40°C, RH <90%, non-condensing |
| Power Supply | AC 100–240 V, 50/60 Hz |
| VA-3000 Dimensions | 430 × 132 × 550 mm (W×H×D) |
| Weight | ~20 kg |
| VS-3000 Sampling Unit Options | VS-3001 to VS-3004 (modular configurations) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 / VS-3000 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | NDIR (CO, CO₂, CH₄, N₂O, SO₂), CLA (NOₓ), MPA (O₂), Electrochemical (O₂), Zirconia (O₂) |
| Minimum Detectable Range | 1–5 ppm |
| Repeatability | ±0.5% of Full Scale |
| Resolution | 0.1 ppm |
| Response Time (T90) | ≤30 s |
| Zero Drift | ±2.0% of Full Scale per week |
| Warm-up Time | 20–60 min depending on sensor type |
| Analog Output | DC 0–1 V or 4–20 mA (optional) |
| Communication Interface | RS-232C |
| Sample Flow Rate | ~0.5 L/min |
| Operating Temperature | 0–40 °C |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Weight (VA-3000) | ~20 kg |
| Enclosure | 19-inch rack-mount chassis (430 × 132 × 550 mm) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 / VS-3000 |
| Instrument Type | Online Analyzer |
| Detection Principle | NDIR, CLA, MPA, Electrochemical (Galvanic), Zirconia |
| Measurable Gases | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂ |
| Minimum Range | 1–5 ppm |
| Repeatability | ±0.5% F.S. |
| Resolution | 0.1 ppm |
| Response Time | T₉₀ ≤ 30 s |
| Zero Drift | ±2.0% F.S./week |
| Warm-up Time | 20–60 min (depending on sensor type) |
| Analog Output | 0–1 V DC or 4–20 mA (optional) |
| Communication Interface | RS-232C |
| Sample Flow Rate | ~0.5 L/min |
| Operating Environment | 0–40 °C, ≤90% RH |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Dimensions (VA-3000) | 430 × 132 × 550 mm (W×H×D) |
| Weight (VA-3000) | ~20 kg |
| Enclosure | 19-inch rack-mountable chassis |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 (Analyzer Unit) / VS-3000 (Sampling System) |
| Instrument Type | Online Continuous Gas Analyzer |
| Target Gases | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂ |
| Detection Principle | NDIR (CO, CO₂, CH₄, N₂O, SO₂), CLA (NOₓ), MPA (O₂), Electrochemical (O₂), Zirconia (O₂) |
| Minimum Detectable Range | 1–5 ppm |
| Full-Scale Repeatability | ±0.5% FS |
| Linearity | ±1.0% FS (≤10× range), ±1.5% FS (>10× range) |
| Zero Drift | ±2.0% FS/week (NDIR/CLA/MPA/ZrO₂), ±1.0% FS/day (Electrochemical O₂) |
| Response Time | T₉₀ ≤ 30 s (single-component mode) |
| Resolution | 0.1 ppm (ppm-range gases) |
| Analog Outputs | DC 0–1 V / 4–20 mA (isolated optional) |
| Digital Interface | RS-232C |
| Sample Flow Rate | 0.5 L/min |
| Operating Temperature | 0–40 °C |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Dimensions (VA-3000) | 430 × 132 × 550 mm (W×H×D) |
| Weight (VA-3000) | ~20 kg |
| Compliance | Designed for ISO/IEC 17025-aligned operation |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 / VS-3000 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | NDIR (CO, CO₂, CH₄, N₂O, SO₂), CLA (NOₓ), MPA (O₂), Electrochemical (O₂), Zirconia (O₂) |
| Repeatability | ±0.5% F.S. |
| Response Time (T90) | ≤30 s |
| Zero & Span Drift | ±2.0% F.S./week |
| Linearity | ±1.0% F.S. |
| Analog Output | 0–1 V DC / 4–20 mA DC |
| Communication Interface | RS-232C |
| Operating Temperature | 0–40 °C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Weight (VA-3000) | ~20 kg |
| Enclosure | 19-inch rack-mount (430 × 132 × 550 mm) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 / VS-3000 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | NDIR (CO, CO₂, CH₄, N₂O, SO₂), CLA (NOₓ), MPA / Electrochemical / Zirconia (O₂) |
| Measuring Range | 1–5 ppm (minimum span) to 100 vol% (max, gas-dependent) |
| Repeatability | ±0.5% FS |
| Resolution | 0.1 ppm |
| Response Time | T90 ≤ 30 s |
| Zero Drift | ±2.0% FS/week |
| Span Drift | ±2.0% FS/week |
| Warm-up Time | 20–60 min (sensor-dependent) |
| Analog Output | DC 0–1 V / 4–20 mA (optional) |
| Digital Interface | RS-232C |
| Sample Flow Rate | ~0.5 L/min |
| Operating Environment | 0–40 °C, RH < 90% |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Weight | ~20 kg (VA-3000), ~14–20 kg (VS-3001–VS-3004) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 / VS-3000 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) and Chemiluminescence (CLA) |
| Target Gases | CO, CO₂, CH₄, NOₓ, SO₂, N₂O, O₂, C₂H₄ |
| Minimum Range | CH₄ 0–5 ppm |
| Repeatability | ±0.5% of Full Scale |
| Resolution | 0.01 ppm |
| Response Time | T₉₀ ≤ 30 s |
| Zero Drift | ±2.0% of Full Scale per week |
| Warm-up Time | ~20 min (NDIR), ~60 min (CLA/MPA) |
| Analog Output | 0–1 V DC or 4–20 mA (optional) |
| Communication Interface | RS-232C |
| Sample Flow Rate | 0.5 L/min |
| Operating Environment | 0–40 °C, RH ≤ 90% |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Dimensions (VA-3000) | 430 mm W × 132 mm H × 550 mm D |
| Weight (VA-3000) | ~20 kg |
| Enclosure | 19-inch rack-mountable chassis |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000/VS-3000 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) and Chemiluminescence (CLA) |
| Measurable Gases | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂ |
| Minimum Range | 1–5 ppm |
| Repeatability | ±0.5% F.S. |
| Linearity | ±1.0% F.S. (±1.5% F.S. beyond 10× range) |
| Zero Drift | ±2.0% F.S./week (±1.0% F.S./day for electrochemical O₂) |
| Span Drift | ±2.0% F.S./week |
| Response Time | T₉₀ ≤ 30 s (single-component mode) |
| Resolution | 0.1 ppm |
| Warm-up Time | 20–60 min (dependent on sensor type) |
| Analog Output | DC 0–1 V or 4–20 mA (optional) |
| Digital Interface | RS-232C |
| Sample Flow Rate | 0.5 L/min |
| Operating Environment | 0–40 °C, ≤90% RH |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Weight | ~20 kg (VA-3000), ~14–20 kg (VS-3001–VS-3004) |