Chemical Analysis Instruments
Filter
Showing 4681–4710 of 10742 results
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Focus | VOC and Water Content Quantification in Paints, Coatings, and Related Polymer Formulations |
| Temperature Control Range | Ambient + 8 °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down | 400 °C → 50 °C in ≤4 min |
| Carrier Gas Flow Control Range | 0–100 mL/min (N₂, He, H₂) |
| Carrier Gas Pressure Control Range | 0–250 kPa |
| Injector Maximum Operating Temperature | 300 °C |
| Injector Pressure Setting Range | 0–250 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC2002 (New Version) |
| Price | USD 14,000 (approx.) |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Forensic Toxicology & Clinical Blood Alcohol Testing |
| Oven Temperature Range | Ambient + 5 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cool-down Time | ≤4 min (400 °C to 50 °C) |
| Carrier Gas Flow Range | 0–100 mL/min (inlet) |
| Carrier Gas Pressure Range | 0–250 kPa |
| Injector Max Temp | 300 °C |
| Injector Pressure Setpoint Range | 0–250 kPa |
| Inlet Total Flow Setpoint Range | 0–1200 mL/min |
| Detection Method | Headspace GC-FID with Internal Standard (tert-Butanol) |
| Compliant Standards | GA/T 105, GB 19522, SF/Z JD0107001-2016, DB31/205-2007 |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC2002 |
| Price Range | USD 21,000 – 42,000 (FOB Shanghai) |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | High-Purity Gas Analysis & Transformer Oil DGA |
| Oven Temperature Range | 8 °C above ambient to 400 °C |
| Temperature Stability | ≤ ±0.1 °C (programmed ramping) |
| Max Ramp Rate | 400 °C to 50 °C in 4 min |
| Cooling Rate | Ambient to 40 °C (forced air) |
| Carrier Gas Flow Range | 0–100 mL/min (digital mass flow control) |
| Carrier Gas Pressure Range | 0–250 kPa (electronic pressure control) |
| Injector Max Temp | 300 °C |
| Injector Pressure Setpoint Range | 0–250 kPa |
| Total Injector Flow Range | 0–1200 mL/min |
| Detection Limits | H₂ ≤ 2 µL/L, CO/CO₂ ≤ 3 µL/L, C₂H₂ ≤ 0.1 µL/L |
| TCD Baseline Noise | ≤ 0.01 mV |
| Drift | ≤ 0.06 mV/30 min |
| FID Baseline Noise | ≤ 1×10⁻¹³ A |
| Drift | ≤ 6×10⁻¹³ A/30 min |
| Retention Time RSD (n=6) | ≤ 2% |
| Peak Area RSD (n=6) | ≤ 3% |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Domain | Food Safety & Agricultural Residue Testing |
| Oven Temperature Range | +5 °C to 400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Time (from 400 °C to 50 °C) | ≤4 min |
| Carrier Gas Flow Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–100 psi |
| Injector Temperature Range | +5 °C to 400 °C |
| Injector Pressure Setting Range | 0–0.04 MPa |
| Total Injector Flow Setting Range | 0–1000 mL/min |
| Column Oven Dimensions | 280 × 280 × 180 mm |
| Weight | 56 kg |
| Power Consumption | 2000 W |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Gas Chromatograph |
| Model | GC2002 |
| Temperature Control Range | Ambient + 3 °C to 450 °C |
| Maximum Ramp Rate | 120 °C/min (adjustable in 0.1 °C/min increments) |
| Cooling Time | ≤5 min (350 °C → 50 °C) |
| Carrier Gas Flow Range | 0–100 mL/min |
| Carrier Gas Pressure Range | 0–100 psi (0–689 kPa) |
| Injector Temperature Max | 300 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Total Injector Flow Setting Range | 0–1200 mL/min |
| Detection Limits | FID ≤3.0×10⁻¹² g/s (n-hexadecane), TCD ≥3500 mV·mL/mg, ECD ≤10 fg/mL (lindane), FPD ≤1.0 pg/s (P) / ≤10.0 pg/s (S) |
| Retention Time RSD | <0.008% |
| Peak Area RSD | <1.0% |
| EPC/EFC Precision | ±0.001 psi / ±0.001 mL/min |
| Programmable Temperature Steps | Up to 16 stages (extendable to unlimited via firmware) |
| External Event Programs | 8 channels |
| Data Interface | RJ45 Ethernet (TCP/IP), native digital signal transmission |
| [Brand | KeChuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Dedicated to High-Purity Gas Analysis |
| Oven Temperature Range | 0–400 °C |
| Maximum Ramp Rate | 60 °C/min |
| Cooling Time (from 350 °C to 50 °C) | ≤4 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 300 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID)] |
| Brand | KeChuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC2002N/PDHID |
| Temperature Control Range | 0–400 °C |
| Oven Ramp Rate | up to 40 °C/min |
| Oven Cool-Down Rate | 60 °C/min (reaching ambient in ≤4 min) |
| Carrier Gas Flow Range | 0–500 mL/min |
| Carrier Gas Pressure Range | 0–0.4 MPa |
| Injector Maximum Temperature | 300 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Target Applications | High-purity helium (5N/6N) impurity profiling per GB/T 4844–2011 |
| Brand | KeChuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC2002N/PDHID |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Dedicated to High-Purity Gas Analysis |
| Oven Temperature Range | 0–400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Time (from 400 °C to 50 °C) | ≤4 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 300 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| [Brand | KeChuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Dedicated to High-Purity Gas Analysis |
| Oven Temperature Range | 0–400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Time (from 400 °C to 50 °C) | ≤4 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 300 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Minimum Detectable Concentration (CO₂) | 0.026 µL/L |
| RSD of Retention Time (n=7) | ≤0.29% |
| RSD of Peak Area (n=7) | ≤6.19% |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Power Industry–Specific DGA (Dissolved Gas Analysis) |
| Oven Temperature Range | Ambient + 3°C to 450°C |
| Maximum Ramp Rate | 0–120 °C/min (adjustable in 0.1 °C/min increments) |
| Cooling Rate | ≤5 min (from 350°C to 50°C with motorized back door) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (EFC, precision ±0.001 mL/min) |
| Carrier Gas Pressure Range & Control | 0–970 kPa (EPC, precision ±0.001 psi ≈ ±0.0069 kPa) |
| Injector Max Temp | 400°C |
| Injector Pressure Set Range | 0–970 kPa |
| Injector Total Flow Set Range | 0–1200 mL/min |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC910 |
| Price Range | USD 4,200–7,000 (FOB) |
| Temperature Control Range | Ambient + 3 °C to 450 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Time | ≤3.5 min (350 °C → 50 °C) |
| Carrier Gas Flow Range | 0–100 mL/min |
| Carrier Gas Pressure Range | 0–100 psi (0–689 kPa) |
| Injector Max Temp | 300 °C |
| Injector Pressure Setpoint Range | 0–100 psi |
| Total Injector Flow Setpoint Range | 0–1200 mL/min |
| Detector Options | TCD, FID, ECD, FPD |
| EPC/EFC Precision | ±0.001 psi / ±0.001 mL/min |
| Retention Time RSD | <0.008% |
| Peak Area RSD | <1.0% |
| Column Oven Volume | 165 × 135 × 92 mm |
| Dimensions (W×D×H) | 482 × 450/600 × 222 mm |
| Weight | ≤20 kg |
| Power | 220 V ±10%, 50 Hz ±5% |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC910 Mobile |
| Temperature Control Range | Ambient + 3 °C to 450 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Time | ≤3.5 min (350 °C → 50 °C) |
| Carrier Gas Flow Control | 0–1200 mL/min (EPC/EFC) |
| Carrier Gas Pressure Control | 0–100 psi (0–689 kPa) |
| Injector Max Temp | 300 °C |
| Detector Options | TCD, FID, ECD, FPD |
| Detection Limits | FID ≤3.0×10⁻¹² g/s (n-hexadecane), ECD ≤10 fg/mL (lindane), TCD ≥6000 mV·mL/mg |
| Baseline Noise | ≤10 µV (FID/TCD), ≤20 µV (ECD/FPD) |
| Linearity | FID 10⁷, TCD 10⁵, ECD/FPD 10⁴ |
| Retention Time RSD | <0.008% |
| Peak Area RSD | <1.0% |
| Dimensions (W×D×H) | 482×450×222 mm |
| Weight | ≤20 kg |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | GC910B |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Power Industry–Specific DGA |
| Oven Temperature Range | Ambient + 8 °C to 400 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-Down Rate | 400 °C to 50 °C in ≤4 min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–250 kPa |
| Injector Max Operating Temperature | 300 °C |
| Injector Pressure Setting Range | 0–250 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC9800 (New Generation) |
| Price Range | USD 4,200 – 7,000 |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GC9800 |
| Price | USD 5,600 (approx.) |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Dedicated to High-Purity Gas Analysis |
| Oven Temperature Range | 8 °C above ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down | 400 °C to 50 °C in ≤4 min |
| Carrier Gas Flow Control Range | 0–100 mL/min |
| Carrier Gas Pressure Control Range | 0–250 kPa |
| Injector Maximum Operating Temperature | 300 °C |
| Injector Pressure Setting Range | 0–250 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | TC-1H Thermal Conductivity Detector (TCD) |
| TCD Sensitivity | ≥5000–10000 mV·mL/mg (benzene) |
| Baseline Noise | ≤0.01 mV |
| Baseline Drift | ≤0.1 mV/30 min |
| Linear Dynamic Range | 10⁵ |
| Minimum Detectable Concentration | H₂: 0.5 ppm, O₂: 1.5 ppm, N₂: 2 ppm |
| Temperature Control Accuracy | ±0.5% of setpoint |
| Programmable Temperature Steps | 8 |
| Temperature Program Reproducibility | ≤1% |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC9800 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry–Specific |
| Oven Temperature Range | Ambient + 8 °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | 400 °C → 50 °C in ≤4 min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–250 kPa |
| Injector Maximum Operating Temperature | 300 °C |
| Injector Pressure Setting Range | 0–250 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region Category | Domestic (China) |
| Model | GC9800 |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Quantitative Analysis |
| Oven Temperature Range | +5 °C above ambient to 400 °C |
| Maximum Ramp Rate | 0–40 °C/min |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC9800 (Network-Enabled) |
| Temperature Control Range | Ambient +3°C to 450°C |
| Maximum Ramp Rate | 0–40°C/min (adjustable in 0.1°C/min increments) |
| Cooling Rate | ≤5 min (350°C → 50°C with motorized back-opening door) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Temperature Range | 0–450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Total Injector Flow Setting Range | 5000–10,000 mV·mL/mg (benzene reference) |
| Detection Limits | TCD ≥6000 mV·mL/mg, FID ≤3.0×10⁻¹² g/s (n-hexadecane), ECD ≤10 fg/mL (lindane), FPD ≤1.0 pg/s (P), ≤10 pg/s (S) |
| Linearity | TCD 10⁵, FID 10⁷, ECD 10⁴, FPD 10⁴ |
| Retention Time RSD | <0.008%, Peak Area RSD: <1.0% |
| EPC/EFC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Column Oven Capacity | 305 × 160 × 278 mm (W×D×H) |
| Dimensions (W×D×H) | 530 × 570 × 506 mm |
| Weight | ≤50 kg |
| Power Consumption | ≤3000 W |
| Input Power | 220 V ±10%, 50 Hz ±5% |
| Operating Environment | 5–35°C, RH ≤85% |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Air Monitoring |
| Oven Temperature Range | Ambient +5°C to 400°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Oven Cooling Rate | 300°C → 50°C in ≤4 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–250 kPa |
| Injector Maximum Temperature | 400°C |
| Injector Pressure Setting Range | 0–250 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detection Method | Flame Ionization Detection (FID) |
| Sample Introduction | Dual-loop 10-port valve with parallel-packed column configuration |
| Detection Limit (1 mL air sample) | 0.04 mg/m³ for both CH₄ and NMHC |
| Compliance Standards | HJ 604-2011, HJ/T 38-1999 |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC9800N |
| Temperature Control Range | Ambient + 3 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min (adjustable in 0.1 °C increments) |
| Maximum Ramp Rate | >120 °C/min |
| Cooling Time | ≤5 min (350 °C → 50 °C, with motorized backdoor) |
| Carrier Gas Flow Range | 0–100 mL/min |
| Carrier Gas Pressure Range | 0–250 kPa |
| Injector Max Temp | 300 °C |
| Injector Pressure Setpoint Range | 0–250 kPa |
| Total Injector Flow Setpoint Range | 0–1200 mL/min |
| EPC/EFC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Retention Time RSD | <0.008% |
| Peak Area RSD | <1.0% |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC9800N/F |
| Temperature Control Range | Ambient + 3°C to 450°C |
| Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 350°C to 50°C in ≤5 min (with auto back-flush door) |
| Carrier Gas Flow Control Range | 0–100 mL/min |
| Carrier Gas Pressure Control Range | 0–250 kPa |
| Injector Max Temp | 300°C |
| Injector Pressure Set Range | 0–250 kPa |
| Total Injector Flow Set Range | 0–1200 mL/min |
| Detection Modes | TCD, FID, ECD, FPD (configurable) |
| Column Oven Programmable Stages | Up to 16 (expandable to unlimited) |
| EPC/EFC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Retention Time RSD | <0.008% |
| Peak Area RSD | <1.0% |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Dimensions (W×D×H) | 530 × 570 × 506 mm |
| Weight | ≤50 kg |
| Brand | KEGUO |
|---|---|
| Origin | Shanghai, China |
| Model | ONH-506S |
| Instrument Type | O/N/H Elemental Analyzer |
| Hydrogen Detector | Thermal Conductivity Detector (TCD) |
| Analytical Range | O: 0.1 ppm – 20 wt% |
| N | 0.1 ppm – 50 wt% |
| H | 0.01 ppm – 2.0 wt% |
| Precision | O: ±1 ppm or RSD ≤ 1.0% |
| N | ±1 ppm or RSD ≤ 1.0% |
| H | ±0.2 ppm or RSD ≤ 2.0% |
| Sensitivity | 0.001 ppm |
| Analysis Time | 120–240 s |
| Pulse Furnace Power | 8.5 kVA |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Nova 9600 |
| Pricing | Available Upon Request |
| Brand | KEJING |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MgO |
| Price | Upon Request |
| Crystal Structure | Cubic |
| Lattice Constant | a = 4.216 Å |
| Growth Method | Arc Melting |
| Melting Point | 2850 °C |
| Density | 3.58 g/cm³ |
| Mohs Hardness | 5.5 |
| Thermal Expansion Coefficient | 12.8 × 10⁻⁶ /°C |
| Dielectric Constant | 9.8 |
| Optical Transmission | >90% @ 200–400 nm, >98% @ 500–1000 nm |
| Cleavage Plane | <100> |
| Standard Orientations | <100>, <110>, <111> |
| Orientation Tolerance | ±0.5° |
| Surface Roughness | Ra < 5 Å (<100> & <110>), Ra < 15 Å (<111>) |
| Polishing | Single-Side or Double-Side CMP |
| Available Sizes | 10 × 10 × 0.5 mm, 5 × 5 × 0.5 mm, Ø1″ × 0.5 mm, Ø2″ × 0.5 mm |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-344 |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer Accessory |
| Measurement Resolution | 0.005 mL |
| Moisture Range | 10 ppm to 100% H₂O |
| Burette Accuracy (10 mL) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 of burette volume |
| Titration Control Precision | ±0.5% |
| Heating Method | Surround-type heating of titration cell |
| Temperature Range | Ambient to 60 °C |
| Temperature Stability | ±3 °C |
| Power Supply | AC 100 V, 50/60 Hz, ~55 W |
| Dimensions (W×D×H) | 100 × 150 × 133 mm |
| Weight | 1.8 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-512 |
| Titration Mode | Fully Automatic |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg – 300 mg H₂O |
| Accuracy | ≤0.3% |
| Minimum Dispensing Increment | 0.1 µg |
| Titration Control Precision | ±0.3% |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-512S |
| Titration Mode | Fully Automatic |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg – 300 mg H₂O |
| Accuracy | ≤0.3% |
| Minimum Dispensing Volume | 0.1 µg |
| Titration Control Precision | ±0.3% |
| Power Supply | AC 100–240 V, 50/60 Hz, ~600 W |
| Heating Temperature Range | 50–1000 °C |
| Evaporation Tube Material | Quartz |
| Sample Boat Material | Quartz |
| Sample Capacity | 10 mL |
| Dimensions | 835(W) × 340(D) × 345(H) mm |
| Weight | 18 kg |