Clinical Laboratory Instruments
Filter
Showing 181–210 of 243 results
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | RFL-1 |
| Dynamic Range | >6 orders of magnitude |
| PMT High-Voltage Supply | −100 V to −1000 V (stability ≤0.05%, current ≥5 mA) |
| Amplifier Gains | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Signal Noise | ≤0.5 mV (p-p, 1× gain) |
| Input Impedance | ≥10 MΩ |
| Integration Time | 0.01–1000 s |
| Sampling Rate | 1–1000 Hz |
| Spectral Response | 300–650 nm (λₘₐₓ = 420 nm) |
| Radiant Sensitivity | >1000 A/lm |
| Software Features | Real-time zero calibration, auto-gain control, peak/area quantitation, ASCII data export, serial communication interface |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Medical Instrument |
| Model | JANUS G3 Blood iQ |
| Pricing | Available Upon Request |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Model | RM6240T |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Pricing | Available Upon Request |
| Brand | Roche |
|---|---|
| Origin | Switzerland |
| Model | Cedex Bio / Cedex Bio HT |
| Principle | Continuous Flow (Channel-Based) Analysis |
| Reagents | Roche-Approved Only |
| Sample Type | Cell Culture Supernatant |
| Analyte Scope | Substrates, Metabolites, Products |
| Throughput | High (Cedex Bio HT), Standard (Cedex Bio) |
| Regulatory Context | Designed for GMP-aligned bioprocess monitoring and QC release testing |
| Brand | RWD |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | MP-500 |
| Pricing | Upon Request |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FMS |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECG Catheter |
| Pricing | Available Upon Request |
| Catheter Material | Polyimide Tubing |
| Effective Length | 15 cm (6") |
| Sizes | 1.1F (0.37 mm) and 2F (0.64 mm) |
| Electrode Material | Platinum |
| Electrode Length | 0.25 mm |
| Inter-Electrode Spacing | 0.5 mm and 1.0 mm (custom spacing available) |
| Electrode Configuration | Side-mounted at tip |
| Connector Type | Redel 14-pin |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FT111B (Mouse), FT211B (Rat) |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Scisense FV892 |
| Pricing | Upon Request |
| Pressure Output | 1 V/100 mmHg (custom output ranges available) |
| Power Supply | External AC adapter, ±12 VDC |
| Dimensions (H × W × L) | 16.8 cm × 22.6 cm × 6.9 cm |
| Calibration Control | 10-position output gain switch |
| Catheter Cable Length Options | 91 cm or 152 cm |
| Output Interface | Standard BNC analog output |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Scisense PV Catheter Series (3F, 5F, 7F) |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Scisense! |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VSL |
| Pricing | Available Upon Request |
| Brand | Selecta |
|---|---|
| Origin | Spain |
| Model | PhotometerS-2000 |
| Measurement Principle | Continuous Flow (Flow-Through Cuvette System) |
| Detection Reagents | Selecta-branded clinical reagent kits |
| Optical System | Dual-wavelength solid-state photodiode detector with 7 fixed interference filters (340, 405, 500, 546, 578, 620, 670 nm) |
| Bandwidth | 10 nm |
| Cuvette Volume | 30 µL |
| Absorbance Range | 0.000–2.500 ABS |
| Display Resolution | 0.001 ABS |
| Computational Resolution | 0.0001 ABS |
| Temperature Control | Peltier-heated sample holder (setpoints: 25 °C, 30 °C, 37 °C |
| Light Source | 6 V / 10 W tungsten-halogen lamp |
| Lamp Life-Saving Mode | Yes |
| Display | 640 × 240 pixel LCD, 256-color graphics |
| Data Interface | RS-232 serial port |
| Ambient Operating Conditions | 15–32 °C, ≤85% RH (non-condensing) |
| Internal Storage | Up to 134 assay methods, 1000 patient results |
| Preloaded Methods | 47 most common clinical assays (e.g., cholesterol, glucose, serum iron, LDH, AST, urea) |
| Curve Fitting Algorithms | Endpoint, Kinetic, Linear Regression, Multi-Point Calibration, Best-Fit Polynomial, Bichromatic Correction |
| Control Interface | Scroll wheel or external USB mouse |
| Dimensions (H×W×D) | 41.2 × 45.3 × 33 cm |
| Power Supply | 100–220 V AC, 50–60 Hz |
| Weight | 15 kg |
| Optional Accessory | BIO-BATH metal dry-block incubator (37 °C, 8-position, for 75 × 13 mm test tubes) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SN-01 |
| Pricing | Upon Request |
| Brand | SOOHOW INSTRUMENT |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | STS-A200 |
| Pricing Range | USD 14,000–21,000 |
| Architecture | Discrete Analytical System |
| Instrument Class | Low-Speed Fully Automated (0–400 rpm equivalent throughput logic) |
| Sample Types | Whole Blood, Serum, Plasma, Urine, Cerebrospinal Fluid (CSF) |
| Analyte Class | Specific Proteins (e.g., CRP, IgG, IgA, IgM, C3, C4, ASO, RF, HbA1c, etc.) |
| Throughput | 180 Tests per Hour |
| Optical Principle | Rate Nephelometry and/or Turbidimetry |
| Light Source | 12 V Long-Life Halogen Lamp |
| Wavelength Range | 340–700 nm (8 Fixed Wavelengths) |
| Reaction Temperature Control | 37.0 ± 0.1 °C via Solid-State Direct-Heating with Full-Circumference Thermal Sensors |
| Reaction Vessels | 40 UV-Transparent Cuvettes |
| Sample Capacity | 25 Tubes on 5-Position Rack-Based Continuous Feed |
| Dispensing Accuracy | ±5% at 3–30 µL (Sample), ±5% at 20–200 µL (Reagent) |
| Precision (CV) | ≤5% |
| Carryover | <1% |
| Stability (4h/8h) | Deviation (B) ≤ ±5% vs. Calibrator Assigned Values |
| Compliance | GB/T 14710–2009 (Environmental & Mechanical Robustness), GB 4793.1–2007 / GB 4793.9–2013 / YY 0648–2008 (Electrical Safety), GB/T 18268.1–2010 / GB/T 18268.26–2010 (EMC) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Spin DIALYZER™ and Fast Spin DIALYZER™ |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SpinColumnTM 96-Well and 384-Well |
| Pricing | Available Upon Request |
| Sample Volume (384-well) | 10–25 µL |
| Binding Capacity (384-well) | 3–30 µg/tip |
| Sample Volume (96-well Micro) | 25–100 µL |
| Binding Capacity (96-well Micro) | 10–100 µg/tip |
| Sample Volume (96-well Macro) | 25–150 µL |
| Binding Capacity (96-well Macro) | 30–275 µg/tip |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SSI-Human |
| Pricing | Upon Request |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BV-10 |
| Pricing | Upon Request |
| Heating Elements | Platinum-Iridium Wire & Tin-Lead Alloy Wire |
| Minimum Tip Diameter Achievable | < 0.3 µm |
| Control | Digital Precision Control of Heat and Tension (3 Independent Channels) |
| Construction | Corrosion-Resistant Housing |
| Footprint | Compact Benchtop Design |
| Primary Application | Patch-Clamp Electrophysiology, Intracellular Microinjection, Single-Cell Physiology |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | BV-10 |
| Heating Elements | Platinum/Iridium wire and Tin-Lead alloy wire |
| Precision Control | Triple independent digital controllers for heat, pull force, and timing |
| Microscope Integration | Dual-objective stereo microscope (low- and high-magnification objectives for coating and polishing) |
| Construction | Corrosion-resistant chassis |
| Footprint | Compact design for benchtop integration in electrophysiology rigs |
| Application Focus | Patch-clamp electrode conditioning, intracellular microinjection, sharp electrode preparation |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | EG-400 |
| Motor Speed | 50–2000 rpm |
| Electrode Manipulator Travel | 47 mm (vertical) |
| Microscope Travel | X: 7 mm, Y: 30 mm, Z: 8 mm |
| Magnification | 30× (10× eyepiece × 3× objective) |
| Capillary Outer Diameter Range | 1.0–1.5 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PMP-100D |
| Pricing | Upon Request |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | M3301 |
| Weight | 550 g |
| Transport Weight | 1.4 kg |
| X-Axis Travel | 10 mm & 37 mm (dual-range configuration) |
| Y-Axis Travel | 25 mm |
| Z-Axis Travel | 25 mm |
| X-Axis Resolution | 0.01 mm (fine) / 0.1 mm (coarse) |
| Y/Z-Axis Resolution | 0.1 mm |
| Mounting Interface | Standard 12 mm clamp & Electrode Holder M3301EH |
| Handedness | Left- and Right-Hand Configurations Available |
| Guidance System | Precision V-groove rails with roller bearings |
| Structural Material | Stainless steel moving components |
| Optical Compatibility | Designed for integration with upright/inverted microscopes up to 250× magnification |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MF-900 |
| Heating Stage Travel (X/Y/Z) | 14 mm / 14 mm / 14 mm |
| Micropipette Manipulator Travel (X/Z) | 12 mm / 28 mm |
| Microscope Stage Travel (X/Y/Z) | ~7 mm / 30 mm / ~8 mm |
| Microscope Magnification | 50× / 100× (10× eyepiece, 5× & 10× objectives) |
| Capillary Outer Diameter | 1.0 mm |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MM-33 |
| Control Type | Manual |
| Coarse Adjustment Range (X/Y/Z) | 37 mm / 20 mm / 20 mm |
| Coarse Resolution | 0.1 mm per axis |
| Fine Adjustment Range (X) | 10 mm |
| Fine Resolution | 0.01 mm |
| Rotational Base | Lockable, Dual-Axis (Horizontal & Vertical) |
| Mounting Compatibility | Magnetic base, standard dovetail or clamp-style stage adapters |
| Intended Use | Electrophysiology, patch-clamp, microinjection, and extracellular stimulation |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MP-285 |
| Drive Type | Motorized (DC stepper motor) |
| Axes | 4-axis (X, Y, Z, Oblique) |
| Travel Range | 25 mm per axis |
| Minimum Step Resolution | 0.04 µm (high-res mode) / 0.2 µm (low-res mode) |
| Maximum Speed | 2.9 mm/sec |
| Drift | ≤10 nm/hr at 24°C |
| Position Display | LCD with real-time X/Y/Z coordinate readout (µm resolution) |
| Control Modes | Continuous motion and discrete step motion |
| Programmability | RS-232 and USB interface for external computer control |
| Homing Function | Yes (user-defined HOME position) |
| Microscope Compatibility | Universal mounting (standard dovetail and adapter plates) |
| Compliance | Designed for GLP-compliant electrophysiology workflows |
| Software Integration | Compatible with SutterPatch, PatchMaster, and third-party acquisition platforms (e.g., Axon pCLAMP, HEKA PatchMaster) |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MP-85 |
| Axes | XYZ motorized with manual coarse/fine/ultra-fine adjustment |
| X-axis rotation | 0–45° in 15° increments |
| Coarse resolution (XYZ) | 0.1 mm |
| Fine resolution (X-axis) | 0.01 mm |
| Ultra-fine resolution (X-axis) | 0.2 µm |
| Dimensions | 25 mm × 25 mm × 25 mm |
| Compliance | Designed for electrophysiology, patch-clamp, and intracellular injection workflows under GLP-aligned laboratory practices |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MP225 |
| Movement Axes | X, Y, Z, and Oblique (4-axis) |
| Resolution | 0.0625–2.0 µm/step (selectable) |
| Maximum Travel | 25.4 mm per axis |
| Minimum Step Size | 0.04 µm (high-resolution mode) |
| Maximum Speed | ≥ 2.9 mm/sec |
| Thermal Drift Stability | ≤ 10 nm/h at 24°C |
| Drive Mechanism | Precision Lead-Screw Actuation |
| Position Display | Real-time LCD readout in micrometers |
| Return-to-Home Function | Yes |
| Motion Modes | Continuous, Stepped, Joystick, FSR Piezo Assist, ROE200 Rotary Encoder Control |
| Programmability | Multi-step motion sequences supported |
| Compatibility | Universal mounting for upright & inverted microscopes |
| Compliance | Designed for GLP/GMP-aligned electrophysiology workflows requiring traceable positioning and audit-ready operation |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MPC-385-2 |
| Controller | MPC-200 |
| Manipulators | (2) MP-285 |
| Rotary Encoder Module | ROE-200 |
| Axes | X, Y, Z, Oblique |
| Travel Range | 25 mm per axis |
| Max Speed | 5 mm/s |
| Resolution | 0.04 µm (high), 0.2 µm (low) |
| Drift | ≤10 nm/hr at 24°C |
| Motion Modes | Continuous & Step |
| Programmable | Yes, via RS-232/USB |
| Homing Function | Yes |
| Compatibility | Universal microscope mounting |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MPC325-2 |
| Axes | X, Y, Z, and Oblique (4-axis) |
| Travel Range | 25.4 mm per axis |
| Step Resolution | 0.0625–2.0 µm |
| Maximum Speed | 3 mm/s |
| Thermal Drift | ≤10 nm/h at 24°C |
| Drive Mechanism | Precision Lead-Screw |
| Position Display | LCD (µm resolution) |
| Control Modes | ROE200 Rotary Encoder, FSR Piezo Controller, Joystick |
| Repeatability Function | Yes |
| Compatibility | Universal Microscope Mounting |