| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SpectraTrend-HT |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | In-Line |
| Optical Geometry | 0°/45° Integrating Sphere |
| Light Source | Full-Spectrum Balanced Solid-State LED Array |
| Spectral Range | 400–700 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability (ΔE*ab) | ≤0.03 |
| Measurement Distance | Up to 100 mm (4 in) |
| Measurement Speed | 5 Hz (non-contact) |
| IP Rating | NEMA 4 / IP56 |
| Interface | Standard Ethernet (TCP/IP), PLC-compatible |
| Software Platform | HunterLab EasyMatch QC v5.x or later |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | SpectraTrend-HT |
| Product Type | Spectrophotometric Color Measurement System |
| Instrument Type | In-line |
| Optical Geometry | 0°/45° Integrating Sphere |
| Light Source | Full-spectrum Balanced Solid-State LED Array |
| Spectral Range | 400–700 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability (ΔE*ab) | ≤ 0.03 |
| Measurement Distance | Up to 100 mm (4 in) |
| Measurement Speed | Up to 5 Hz |
| IP Rating | NEMA 4 / IP56 |
| Interface | Standard Ethernet (TCP/IP), PLC-compatible, No RS-232 Required |
| Software Platform | HunterLab EasyMatch QC v5.x or later |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SpectraTrend-HT Textile Inline Color Measurement System |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Inline |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Full-spectrum balanced solid-state LED system |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | STOL-M |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | In-Line |
| Optical Geometry | 0°/45° Integrating Sphere |
| Light Source | Full-Spectrum LED |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | STOL-M Series |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | In-Line |
| Optical Geometry | 0°/45° Integrating Sphere |
| Light Source | Full-Spectrum LED |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | STOL-M1 |
| Product Category | Spectrophotometric Colorimeter |
| Instrument Type | In-Line |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum LED |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | STOL-MG |
| Product Type | Spectrophotometric Color & Gloss Instrument |
| Instrument Type | In-Line |
| Optical Geometry | Multi-Angle (0°/30°) |
| Light Source | Full-Spectrum LED |
| Spectral Range | 400 nm – 700 nm |
| Spectral Bandwidth | 10 nm |
| Aperture | 1 inch |
| Repeatability | ΔE* < 0.03 (Avg), < 0.05 (Max) in CIE L*a*b* on White Tile (20 readings) |
| Gloss Measurement Angles | 20° and 60° |
| Gloss Range | 20°: 0–2,000 GU |
| 60° | 0–1,000 GU |
| Gloss Accuracy | ±0.1 GU (0–199.9 GU), ±0.1% (200–2,000 GU) |
| Gloss Reproducibility | ±0.5 GU (0–199.9 GU), ±0.4% (200–2,000 GU) |
| Measurement Speed | 20 readings/sec |
| Optical Design | Dual-Beam, Sealed Optics with 256-Pixel Diode Array & Concave Holographic Grating |
| Housing Rating | NEMA 4 / IP56 |
| Standoff Distance | 65 mm – 115 mm |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Product Type | Spectrophotometric Color & Gloss Measurement System |
| Instrument Type | In-Line |
| Optical Geometry | Multi-Angle (0°/30°) |
| Light Source | Full-Spectrum LED |
| Spectral Range | 400 nm – 700 nm |
| Spectral Bandwidth | 10 nm |
| Aperture Size | 1 inch |
| Repeatability | ΔE* < 0.05 (Max) / < 0.03 (Avg) in CIE L*a*b* on White Tile (20 readings) |
| Gloss Measurement Angles | 20° and 60° |
| Gloss Range | 20°: 0–2,000 GU |
| 60° | 0–1,000 GU |
| Gloss Accuracy | ±0.1 GU (0–199.9 GU), ±0.1% (200–2,000 GU) |
| Gloss Reproducibility | ±0.5 GU (0–199.9 GU), ±0.4% (200–2,000 GU) |
| Measurement Speed | 20 readings/sec |
| Sensor Configuration | Triple-sensor (color, height, gloss) |
| Enclosure Rating | NEMA 4 / IP56 |
| Scan Mechanism | Full-width automated traverse system (max speed 5 m/s, 10-position adjustable probe alignment) |
| Compliance | Supports LQM, PAT, Six Sigma, DMAIC, and GLP/GMP-aligned data integrity workflows |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | STOL-MG Series |
| Product Type | Spectrophotometric Color & Gloss Analyzer |
| Instrument Type | In-Line |
| Optical Geometry | Multi-Angle (0°/30°) |
| Light Source | Full-Spectrum LED |
| Spectral Range | 400 nm – 700 nm |
| Spectral Bandwidth | 10 nm |
| Aperture Size | 1 inch |
| Repeatability | ΔE* < 0.05 (Max) / < 0.03 (Avg) in CIE L*a*b* on White Tile (20 readings) |
| Gloss Measurement Angles | 20° and 60° |
| Gloss Range | 20°: 0–2,000 GU |
| 60° | 0–1,000 GU |
| Gloss Accuracy | ±0.1 GU (0–199.9 GU), ±0.1% (200–2,000 GU) |
| Gloss Reproducibility | ±0.5 GU (0–199.9 GU), ±0.4% (200–2,000 GU) |
| Measurement Speed | 20 readings/sec |
| Housing Rating | NEMA 4 / IP56 |
| Sensor Configuration | Triple-sensor (color, height, gloss) |
| LED Lifetime | ≥5 years continuous operation |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | STOL-S Series |
| Product Category | Spectrophotometric Colorimeter |
| Instrument Type | In-line |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-spectrum LED |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | STOL-S1 |
| Product Category | Spectrophotometric Colorimeter |
| Instrument Type | In-line |
| Optical Geometry | 0°/45° Integrating Sphere |
| Light Source | Full-spectrum LED |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | STOL-S2 |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | In-Line |
| Optical Geometry | 0/45° Integrating Sphere |
| Light Source | Full-Spectrum LED |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model Series | HunterLab Spectrophotometric Colorimeters |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere (UltraScan Pro, UltraScan VIS), 0°/45° (Agera), 45°/0° (ColorFlex EZ, MiniScan EZ), 0°/30° (Aeros, STHT), d/0° (Vista) |
| Light Source | Xenon Arc Lamp |
| Spectral Range | 360–780 nm (UltraScan VIS), 350–1050 nm (UltraScan Pro), 400–700 nm (select models) |
| Repeatability | ΔE*ab ≤ 0.03 (average, CIE Lab scale) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UltraScan PRO Accessory Kit |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 350–1050 nm |
| Repeatability (ΔE*ab) | ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan PRO |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 350–1050 nm |
| Wavelength Interval | 2 nm (acquisition), 5 nm (reporting) |
| Repeatability | ≤0.03 ΔE*ab (CIE Lab, 20 measurements on standard white tile) |
| Reflectance/Absorbance Measurement Modes | Specular Component Included/Excluded (SCI/SCE) Auto-Switchable |
| Aperture Sizes | 19 mm (1.00″), 9 mm (0.50″), 4 mm (0.25″) |
| Transmission Path Length | 80 mm |
| Integrating Sphere Diameter | 152 mm |
| Sphere Coating | Spectraflect™ |
| Mirror & Port Coating | Duraflect™ |
| Compliance | ASTM D2244, ASTM E308, ISO 7724, ISO 11664, CIE No. 15, AATCC Evaluation Procedure 1, USP <1061>, FDA 21 CFR Part 11 (with optional software configuration) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | UltraScan PRO Automotive Interior & Exterior Color Difference Meter |
| Product Category | Color Difference Meter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 350–1050 nm |
| Spectral Interval (Acquisition) | 2 nm |
| Reporting Interval | 5 nm |
| Optical Bandwidth | 5 nm |
| Repeatability | ≤ 0.03 ΔE*ab (Mean, CIE Lab, White Tile) |
| Detector | 512-Element Silicon Photodiode Array |
| UV Calibration | D65 with Fluorescence Correction |
| Reflectance Measurement Areas | LAV (25 mm), SAV (13 mm), XSAV (7 mm) |
| Minimum Liquid Volume | 0.4 mL |
| UV Transmission Capability | Down to 350 nm |
| Compliance | CIE No. 15, ASTM E308, ASTM D2244, ASTM E2539, USP <1061>, ISO 7724, ISO 11664, GLP/GMP-Ready Data Integrity Features |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan PRO |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 350–1050 nm |
| Wavelength Accuracy | ±5 nm |
| Repeatability (ΔE*ab) | ≤0.03 |
| Measurement Apertures | 19 mm, 9 mm, 4 mm |
| Transmission Path Length | 80 mm |
| UV Calibration & Control | Automatic |
| Specular Component | Include/Exclude (SCI/SCE) Auto-Switching |
| Lamp Lifetime | ≥1,000,000 flashes |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan PRO |
| Instrument Type | Benchtop |
| Optical Geometry | 8°/diffuse (d/8°) with integrated sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 350 nm – 1050 nm |
| Spectral Interval | 2 nm (acquisition), 5 nm (reporting) |
| Optical Bandwidth | 5 nm |
| Repeatability | ΔE*₀₀ ≤ 0.03 |
| Detector | 512-element silicon photodiode array with extended NIR sensitivity |
| Compliance | CIE No. 15, ASTM E308, ASTM D2244, ASTM D6290, USP <631>, ISO 7724, ISO 11664, FDA 21 CFR Part 11 (via EasyMatch QC software) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Product Type | Benchtop Spectrophotometer |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 350–1050 nm |
| Spectral Resolution | 1.37 nm |
| Data Interval | 5 nm |
| Repeatability (ΔE*ab) | ≤ 0.03 |
| Compliance | CIE, ASTM D2244/D6290/D313/D5386, ISO 7724/1, DIN 5033, JIS Z 8722, USP <1061>, FDA 21 CFR Part 11 (with audit trail enabled in EasyMatch QC) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan PRO |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 350–1050 nm |
| Wavelength Interval | 5 nm |
| Spectral Bandwidth (FWHM) | 5 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Resolution | <2 nm (1.37 nm) |
| Reflectance/Transmittance Range | 0–200% |
| Photometric Resolution | 0.003% (displayed as 0.01%) |
| Repeatability (ΔE*ab, white tile) | ≤0.03 |
| Measurement Time | ≤2 s |
| Aperture Options | 19 mm (LAV), 9 mm (MAV), 4 mm (SAV) |
| Transmission Chamber | Up to 80 mm path length |
| Interface | USB or RS-232C |
| Compliance | ASTM E308, ISO 11664, CIE No. 15, USP <1061>, FDA 21 CFR Part 11 (via EasyMatch-QC) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan PRO |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 350–1050 nm |
| Wavelength Reporting Interval | 5 nm |
| Spectral Resolution | <2 nm (1.37 nm) |
| Wavelength Accuracy | ±0.1 nm |
| Photometric Range | 0–200% |
| Photometric Repeatability | 0.03 ΔE*ab (std dev) |
| Measurement Time | ≤2 s |
| Aperture Options | 19 mm (LAV), 9 mm (MAV), 4 mm (SAV) |
| Compliance | CIE, ASTM E308, ASTM D2244, ASTM D6290, DIN 5033, JIS Z 8722, USP <1061>, FDA 21 CFR Part 11 (with EasyMatch-QC software) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan PRO |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Compliance | ASTM E308, ISO 11664-4, CIE No. 15, USP <1061>, FDA 21 CFR Part 11 (with optional audit trail module) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UltraScan Pro |
| Pricing | Upon Request |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan Pro Food Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 350–1050 nm |
| Spectral Resolution | <2 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Interval | 5 nm |
| Reflectance/Transmittance Range | 0–200% |
| Spectral Data Resolution | 0.01% |
| Repeatability (ΔE* CIELab, LAV) | ≤0.03 |
| Lamp Lifetime | >500,000 flashes |
| Measurement Time | <1.5 s |
| Minimum Inter-Measurement Interval | <2.0 s |
| Port Sizes | 19 mm (0.75″), 9 mm (0.35″), 4 mm (0.16″) |
| UV Calibration | Automatic D65 UV-Visible Control for Fluorescent Samples |
| Compliance | NPL-traceable calibration, ASTM E308, ISO 7724, CIE No. 15, USP <1061>, FDA 21 CFR Part 11 (via optional software module) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan PRO Pharmaceutical Color Measurement Instrument |
| Type | Benchtop Colorimeter |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 350 nm – 1050 nm |
| Spectral Interval (Acquisition) | 2 nm |
| Reporting Interval | 5 nm |
| Repeatability | ≤ 0.03 ΔE*ab (Average, CIE Lab) |
| Optical Bandwidth | 5 nm |
| Detector | 512-element Silicon Photodiode Array with Extended NIR Response |
| Mirror Finish Compensation | Automated Specular Component Included/Excluded (SCI/SCE) |
| Reflectance/Transmittance Measurement Modes | Yes |
| Sample Port Coating | Spectrally Neutral Barium Sulfate-Based Diffuse Coating |
| Compliance | ASTM E308, ISO/CIE 11664, USP <1061>, FDA 21 CFR Part 11 Ready (with optional audit trail module) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UltraScan PRO Short-Fiber |
| Product Type | Color Difference Meter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Xenon Flash Lamp |
| Spectral Range | 350–1050 nm |
| Repeatability | ΔE*ab ≤ 0.03 (average, CIE Lab) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan PRO |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 350–1050 nm |
| Repeatability (ΔE*ab) | ≤0.03 |
| Measurement Apertures | 19 mm, 9 mm, 4 mm |
| UV Calibration | Automatic |
| Mirror Mode | Auto-Included / Auto-Excluded |
| Transmission Path Length | 80 mm |
| Viewing Mirror | Integrated Real-Time Sample Coverage Indicator |
| Flash Lamp Lifetime | ≥1,000,000 flashes |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan PRO |
| Product Type | Benchtop Spectrophotometric Color Measurement Instrument |
| Optical Geometry | d/8° Integrating Sphere (with Specular Component Included or Excluded) |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 350 nm – 1050 nm |
| Wavelength Accuracy | ±5 nm |
| Repeatability (ΔE*ab, White Tile) | ≤0.03 |
| Aperture Sizes | 19 mm, 9 mm, 4 mm |
| Transmission Path Length | 80 mm |
| UV Calibration & Control | Automatic Real-Time UV Intensity Adjustment for Fluorescent Sample Measurement |
| Compliance | ASTM E308, ISO/CIE 11664 (CIE S 014), ISO 7724, USP <1061>, FDA 21 CFR Part 11 Ready (with optional software configuration) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | UltraScan PRO |
| Product Category | Spectrophotometric Colorimeter |
| Instrument Form Factor | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE*ab ≤ 0.03 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan PRO |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed xenon lamp |
| Spectral Range | 350 nm – 1050 nm |
| Spectral Interval (Acquisition) | 2 nm |
| Reporting Interval | 5 nm |
| Optical Bandwidth | 5 nm |
| Repeatability | < 0.03 ΔE* |
| Detector | 512-element diode array with extended IR sensitivity |
| Mirror Finish Options | Specular Component Included/Excluded (SCI/SCE) |
| Aperture Sizes | LAV (25 mm), SAV (13 mm), XSAV (7 mm) |
| Minimum Liquid Volume | 0.4 mL |
| Compliance | CIE No. 15, ASTM E308, ASTM D2244, ASTM E2539, USP <631>, ISO 7724, ISO 11664, FDA 21 CFR Part 11 (via EasyMatch QC software) |