| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-19216 |
| Compliance | GB/T 19216.11–2003, GB/T 19216.21–2003, GB/T 19216.23–2003, GB/T 19216.25–2003, GB/T 19216.12–2008, GB/T 19216.31–2008, IEC 60331-11:1999, IEC 60331-12:2002, IEC 60331-21:1999, IEC 60331-23:1999, BS 6387:1994 |
| Test Temperature | ≥750 °C (flame zone) |
| Voltage Rating | ≤450/750 V |
| Application Scope | Mineral insulated cables, power cables, control cables, optical fiber cables |
| Brand | Jiubin |
|---|---|
| Model | JB-2 |
| Origin | Taiwan |
| Compliance | GB/T 2406, GB/T 5454 |
| Oxygen Flow Range | 60–600 L/h |
| Flow Control Accuracy | ±5% |
| O₂ Supply Pressure | >0.25 MPa |
| N₂ Supply Pressure | >0.25 MPa |
| Operating Pressure (O₂/N₂ Mix) | 0.1 MPa |
| Test Gas | High-Purity O₂/N₂ Mixture |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-300F |
| Pricing | Upon Request |
| Chamber Dimensions | 300 × 1200 × 450 mm |
| Fuel Gas | High-Purity Propane or Liquefied Petroleum Gas (LPG) |
| Specimen Length | 600 ± 25 mm |
| Specimen Outer Diameter | 1–30 mm |
| Test Environment | Non-ventilated enclosure |
| Ignition Source | Calibrated propane burner with adjustable flow control (dual gas/air mass flow meters) |
| Operation Mode | Manual or Auto-select toggle switch |
| Compliance | GB/T 18380.1–2001, IEC 60332-1-2 (Ed. 3.0, 2021) |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | DIN 53438 |
| Compliance | DIN 53438, DIN 4102-B2 |
| Chamber Dimensions (W×H×D) | 730 × 950 × 450 mm |
| Weight | 65 kg |
| Sample Holder | Adjustable-angle stainless steel support with interchangeable fixtures |
| Burner | Tilt-adjustable Bunsen-type burner with calibrated flame height indicator |
| Gas Control | Precision mass-flow regulated propane/butane supply system |
| Viewing Window | Heat-resistant borosilicate glass front panel |
| Exhaust | Integrated axial exhaust fan with duct interface |
| Safety Features | Front-access design, thermal insulation, fail-safe gas shutoff |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | FMVSS 302 |
| Compliance | FMVSS 302, ISO 3795, DIN 75200 |
| Chamber Material | V4A Stainless Steel (1.4404 / AISI 316L) |
| Sample Holder | Type A & Type B Configurations |
| Flame Source | Adjustable Propane/Butane Burner with Precision Needle Valve |
| Viewing Window | Heat-Resistant Borosilicate Glass |
| Service Access | Side Maintenance Door |
| Optional Fixtures | VW TL 1010 & Porsche PTL 8501 Compliant Sample Clamps |
| Dimensions (W×H×D) | 500 × 385 × 245 mm |
| Weight | 22 kg |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | UL94 |
| Chamber Material | Polished Stainless Steel |
| Burner Adjustment | Horizontal travel 240 mm, angular tilt 0°/20°/45° |
| Specimen Holder Travel | Horizontal 840 mm, Vertical 730 mm |
| Specimen Holders | 5 types for multi-standard compliance |
| Timer Range | 0–100 s in 1-s increments |
| Airflow Control | Integrated mass-flow regulated exhaust system |
| Exhaust Fan | Variable-speed centrifugal fan |
| External Dimensions (W×H×D) | 1500 × 1500 × 600 mm |
| Net Weight | 200 kg |
| Applicable Standards | UL 94, ASTM D635, ASTM D3801, ASTM D4804, ASTM D5048, ASTM D4986, IEC 60695-11-10 (replaces ISO 1210), IEC 60695-11-20 (replaces ISO 10351), ISO 9772, ISO 9773 |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ISO 11925-2 |
| Airflow Velocity Range | 0–10 m/s |
| Timer Resolution | 0.1 s |
| Ignition Angle Options | 0° (vertical) and 45° |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | EngineMaster inspex |
| Application Domain | Internal Combustion Engine Research |
| Core Function | Crank-Angle-Synchronized Endoscopic Spray & Combustion Visualization with Quantitative Image-Based Diagnostics |
| Compliance Context | Designed for ASTM D7463, ISO 8178-4, and GLP/GMP-aligned R&D environments |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlameMaster inspex |
| Application | Optical diagnostics of combustion processes via chemiluminescence imaging, two-color pyrometry, Abel-inverted 2D reconstruction, endoscopic high-temperature imaging, and high-speed flame dynamics analysis |
| Compliance | Designed for research-grade combustion laboratories compliant with ISO/IEC 17025-aligned measurement traceability and compatible with GLP/GMP-relevant data integrity frameworks (e.g., audit-trail-enabled software logging) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlameMaster Multi-Parameter |
| Application Domain | In-situ, quantitative, multi-parameter laser diagnostics in reactive flows |
| Core Modalities | OH-LIF, CH-LIF, C₂-LIF, NO-LIF, PLIF (fuel), Mie scattering, Rayleigh scattering, thermographic phosphor imaging (TPI), particle image velocimetry (PIV), stereo-PIV, tomographic PIV (Tomo-PIV), dual-plane PIV, simultaneous multi-modal acquisition |
| Spatial Resolution | Sub-pixel (typically ≤ 10 µm/pixel with optimized optics) |
| Temporal Resolution | Up to 10 kHz (with high-speed CMOS cameras) |
| Laser Sources | Nd:YAG (266–1064 nm), OPO/OPA tunable systems (210–2000 nm), pulsed diode lasers |
| Detection | Intensified CCD (ICCD), scientific CMOS (sCMOS), EMCCD, stereo/tomographic camera configurations |
| Software Platform | DaVis 10.3+ with FlameMaster-specific modules (FlameAnalysis, ChemiLum, TempMap, VelocityEngine) |
| Compliance | Fully compatible with ISO/IEC 17025 laboratory accreditation workflows |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlameMaster Multifunctional |
| Pricing | Available Upon Request |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlameMaster Tunable LIF |
| Application | Planar Laser-Induced Fluorescence (PLIF) imaging of diatomic flame species and radicals |
| Laser Type | Tunable pulsed dye laser integrated with Nd:YAG pump laser |
| Wavelength Range | Typically 210–800 nm (dependent on dye and harmonics) |
| Control Interface | Fully integrated with DaVis 10+ software platform |
| Calibration | Automated spectral calibration via LIF-excitation scan |
| Quantification Support | Reference burner-based concentration calibration |
| System Mounting | Modular rail-mounted configuration for flexible optical alignment |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlameMaster-PIV |
| Application Domain | Simultaneous PIV and OH-PLIF in reactive flows |
| Platform Integration | DaVis v10+ Synchronized Acquisition & Processing |
| Compliance Framework | ASTM E2912, ISO 20486 (Optical Diagnostics in Combustion), GLP-aligned Data Audit Trail |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlameMaster3D |
| Type | Tomographic Laser-Induced Fluorescence (LIF) and Chemiluminescence Imaging System |
| Configuration | Multi-camera or single-camera time-averaged volumetric acquisition |
| Compatible with | OH*, CH*, C₂*, and other flame radical emissions |
| Integrated with | FlowMaster Tomo PIV for concurrent 3D flow–flame coupling |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | ICOS |
| Application | In-cylinder crank-angle-resolved optical sensing for air/fuel ratio, EGR rate, CO₂ concentration, gas temperature, and H₂O concentration |
| Probe Integration | Spark plug–, glow plug–, or M5-threaded mounting |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) with wavelength modulation spectroscopy (WMS) |
| Data Resolution | Crank-angle-resolved (≤0.1° CA), single-cycle capable |
| Response Time | <10 µs |
| Compatibility | Gasoline, Diesel, CNG, and multi-fuel engines |
| Certification Compliance | Designed for ISO 8178, ASTM D975/D3606, and EU Stage V R96-compliant test bed environments |
| Software Interface | Compatible with LaVision DaVis and third-party DAQ systems (e.g., NI VeriStand, dSPACE SCALEXIO) via TTL/encoder synchronization |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | PLIF-HS |
| Camera Frame Rate | Up to 10 kHz |
| Laser Repetition Rate | ≥10 kHz |
| Imaging Modality | Planar Laser-Induced Fluorescence (PLIF) |
| Target Species | OH, CH, NO, acetone, ketones, hydrocarbons |
| Synchronization Precision | <1 ns jitter (PTU X timing unit) |
| Software Platform | FlameMaster v5.x with real-time acquisition & post-processing modules |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-FHB08 |
| Price | USD 495 (FOB Qingdao) |
| Compliance | MEP “Guidelines for Standardization of Comprehensive Ecological and Environmental Protection Law Enforcement Equipment (Standard Configuration, 2020 Edition)” |
| Construction | Anodized aluminum frame chassis |
| Configuration Flexibility | Modular slot-based layout for field-customizable PPE integration |
| Transport Form Factor | Dual-option — rugged wheeled trolley case or ergonomic dual-shoulder backpack |
| Brand | Makewave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HXO-T60 Series |
| Application Field | Radioisotope Sample Preparation & Environmental Radiometric Analysis |
| Measurement Target | Organic ³H and ¹⁴C in biological, environmental, and combustible matrices (e.g., plant/animal tissues, soils, polymers, fuels) |
| Operating Temperature | Up to 1200 °C (standard operation at 1000 °C) |
| Thermal Zones | Three independently controlled zones (combustion, buffer, reduction) |
| Gas Control | Dual O₂/N₂ supply with mass flow regulation |
| Water Collection | Dual-stage chilled condensation (recirculating chiller + secondary cold trap) |
| CO₂ Capture | Tandem absorption bottles with high-efficiency bubbling design |
| Reactor Tube | Custom quartz tubing (replaceable, low-memory, low-background) |
| Sample Vessels | Boat-type ceramic crucibles with optimized gas-path geometry for complete secondary combustion |
| Control System | PLC-based automation with HMI touchscreen interface (real-time temperature profiling, data logging, alarm history) |
| Safety | Independent over-temperature protection per zone |
| Chamber Access | Top-hinged dual-door configuration for maintenance and visual inspection |
| Brand | Marlin Engineering (MEI) |
|---|---|
| Origin | USA |
| Model | ME 1200-1 |
| Compliance | FAA-Approved OSU Apparatus |
| Standards | FAR Part 25 Appendix F Part IV, Airbus AITM 2.0006, Boeing BSS 7322, ASTM E906 |
| Sample Size | 15 cm × 15 cm (vertical orientation) |
| Radiant Heat Flux | 35 kW/m² (adjustable: 20–50 kW/m²) |
| Test Duration | Up to 15 min |
| Output Metrics | Peak Heat Release Rate (PHRR), Total Heat Release at 15 min (THR₁₅), Time-to-Flashover Estimation |
| Calibration | Water-cooled thermopile with mass flow-controlled calibration burner |
| Airflow Control | Orifice plate flowmeter + PID-regulated constant-temperature/constant-flow supply |
| Data Acquisition | Integrated high-speed DAQ system with NIST-traceable thermal sensors |
| Brand | Marlin Engineering (MEI) |
|---|---|
| Origin | USA |
| Model | ME1100-1 |
| Compliance | FAA-recognized NBS-type smoke density chamber |
| Standards | FAA AC 20-135, BSS 7238, BSS 7239, AITM 2.0007, AITM 3.0005, HB 6577 |
| Temperature Control | PID-regulated radiant heating system |
| Optical Path | Fixed optical platform with calibrated photometric assembly |
| Light Source | Stable tungsten-halogen lamp with collimated beam |
| Transmittance Measurement Range | 0–100% (logarithmic smoke density scale: 0–1000 Ds) |
| Gas Sampling Interface | Four Swagelok® ports on chamber ceiling |
| Heat Flux Capability | 0–50 kW/m² (with traceable heat flux meter) |
| Sample Handling | Pneumatic specimen insertion mechanism |
| Ignition | Electronic spark ignition burner |
| Calibration | Three neutral density filters (certified OD values), stainless steel specimen holders (3× standard + 1 blank), gas flow and pressure regulation for controlled flaming combustion |
| Ancillary | Integrated smoke toxicity test kit (portable sampling pump, colorimetric detector tubes), real-time data acquisition system with ASTM/ISO-compliant reporting engine |
| Brand | Marlin Engineering (MEI) |
|---|---|
| Origin | USA |
| Model | ME1300-3 |
| Compliance | FAR Part 25 Appendix F Part VI, Airbus AITM 2.0053, Boeing BSS 7365, MH/T 6042-2006 |
| Radiation Panel Angle | 30° to horizontal |
| Radiant Heat Source | 400 VAC 3-phase resistive panel with six 76 mm-wide heating strips |
| Max Operating Temperature | ≥704 °C |
| Temperature Control Accuracy | ±0.1 °C (PID) |
| Ignition Source | Propane Wurster burner, 0.15 mm orifice |
| Flame Height Adjustment | ≥51 mm above specimen plane |
| Laser Distance Monitoring System | For real-time flame front tracking |
| Water-Cooled Heat Flux Sensor | ≥60 kW/m² range, integrated recirculating coolant loop |
| Heat Flux Sensor Mounting | 3.2 mm steel bracket with three 25.4 mm-diameter mounting holes (center-to-center spacing: 51 mm |
| Specimen Holder Options | Standard and short hook-and-loop test fixture (dual-position) |
| Data Acquisition | Automated time-stamped logging, stop-on-criterion, timing resolution: 0.1 s |
| Thermal Monitoring | Calibrated thermocouple positioned 279 mm from rear wall, 292 mm from right wall, and 51 mm below radiant panel (accuracy: ±2 °C) |
| Actuation | Pneumatic sliding drawer for specimen insertion/retraction |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ME 1300-3 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | ME1200 |
| Pricing | Available Upon Request |
| Brand | MEI / Marlin Engineering |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ME1500-3 + ME1900-5 |
| Pricing | Available Upon Request |
| Brand | MEI / Marlin Engineering |
|---|---|
| Origin | USA |
| Supplier Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ME 1500-3 + ME 2000-1 |
| Pricing | Available Upon Request |
| Brand | MEI / Marlin Engineering |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ME1500-3 + ME2100-1 |
| Pricing | Upon Request |
| Brand | MEI / Marlin Engineering |
|---|---|
| Origin | USA |
| Model | ME1200-1 |
| Compliance | FAR 25 Appendix F Part IV, Airbus AITM 2.0006, Boeing BSS 7322 |
| Radiant Flux | 35 kW/m² |
| Heating Source | Four glow bars |
| Temperature Control | Dual independent PID controllers |
| Sample Introduction | Pneumatic actuated pusher with shielded access door |
| Burner Configuration | Fixed upper burner + movable lower burner |
| Calibration System | Movable T-type calibration burner with mass flow controller |
| Heat Flux Measurement | Water-cooled thermopile with active cooling circuit |
| Airflow Control | Regulated isothermal and isovolumetric supply via orifice flow meter |
| Data Acquisition | Integrated DAQ system with ASTM/ISO-compliant heat release rate test software |
| Brand | MEI/Marlin Engineering |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ME1500-3 + ME1700-3 |
| Pricing | Available Upon Request |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | 3MC |
| Chamber Volume | 27 m³ (3000 mm × 3000 mm × 3000 mm) |
| Compliance | IEC 61034, BS 6853, GB/T 17651.1–2 |
| Light Source | 2896 K tungsten halogen lamp with constant-current driver |
| Detector | Cosine-corrected silicon photodiode with color filter |
| Optical Resolution | 0.01% transmittance |
| Exhaust | Top-mounted centrifugal fan |
| Ignition | Remote-controlled surface igniter |
| Sample Support | Stainless steel alcohol tray and adjustable cable test stand |
| Data System | Integrated industrial touchscreen PC with thermal printer |
| Chamber Lining | PTFE-coated SUS 304 stainless steel interior |
| Viewing | Dual-side tempered glass ports and front observation window |
| Air Balance | Bottom perimeter ventilation openings |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | BCC |
| Internal Chamber Dimensions | 1350 × 800 × 800 mm |
| Overall Height | 3.2 m |
| Grating Aperture | 30 × 30 mm, Height: 30 mm |
| Airflow Velocity Range | 0–10 m/s, Accuracy: ±0.1 m/s |
| Exhaust Duct Thermocouples | 3 × K-type, Range: 0–300 °C, Accuracy: ±0.1 °C |
| Calibration Plate Thermocouples | 3 × K-type, Range: 0–900 °C, Accuracy: ±0.1 °C |
| Light Source | Tungsten filament lamp, CCT: 2896 K |
| Photodetector | Cosine-corrected silicon photodiode with spectral filter for CIE photopic luminosity match |
| Data Interface | RS-232 |
| Timer Resolution | 0.1 s across 6 independent channels |
| Compliance | DIN 54837:2007, DIN 5510-2:2007, DIN 50055:1989 |