Common Laboratory Equipment
Filter
Showing 15391–15420 of 17606 results
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Type | Box-Type Muffle Furnace |
| Model | 2.5-10T/TP |
| Maximum Temperature | 1200 °C |
| Temperature Control Accuracy | ±5 °C |
| Heating Element | Resistance Wire |
| Internal Chamber Dimensions | 300 × 200 × 120 mm |
| Rated Power | 2.5 kW |
| Ramp Time to 1200 °C | ≤30 min |
| Insulation Material | High-Purity Ceramic Fiber |
| External Surface Temperature at 1000 °C Hold | ≤50 °C |
| Compliance | Designed for ASTM E1112, ISO 8573-1 (thermal stability class), GLP-compliant operation |
| Brand | Truelab |
|---|---|
| Origin | Zhejiang, China |
| Pump Type | Oil-lubricated rotary vane |
| Models | 2XZ-1 / 2XZ-2 / 2XZ-4 |
| Ultimate Pressure | 6×10⁻² Pa |
| Pumping Speed | 1 / 2 / 4 L/s |
| Inlet Port Diameter | Φ16 mm (2XZ-1), Φ25 mm (2XZ-2 & 2XZ-4) |
| Motor Power | 0.25 kW (2XZ-1), 0.37 kW (2XZ-2), 0.55 kW (2XZ-4) |
| Net Weight | 19 kg (2XZ-1), 27 kg (2XZ-2), 30 kg (2XZ-4) |
| Dimensions (L×W×H) | 470×140×235 mm (2XZ-1), 480×140×255 mm (2XZ-2), 510×140×255 mm (2XZ-4) |
| Brand | Truelab |
|---|---|
| Model | 2Y1D |
| Type | Magnetic Stirrer |
| Max. Stirring Volume | 3 L |
| Speed Range | 300–1500 rpm |
| Heating Temperature Range | Ambient to 250 °C |
| Power Adjustment | 0–550 W |
| Temperature Sensing | External PT1000 Sensor |
| Temperature Display Range | 30–270 °C |
| Control Accuracy | ±1 °C |
| Dimensions | 196 × 196 × 118 mm |
| Input | 220 V, 50 Hz |
| Housing Material | Glass-Fiber-Reinforced Engineering Nylon |
| Heating Element | Carbon-Fiber Far-Infrared Tube |
| Display | 3.5-inch VA-LCD |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | 820B |
| Type | Compressor-based dehumidifier |
| Application | Industrial-grade laboratory environmental control |
| Dimensions (L×W×H) | 400 × 345 × 640 mm |
| Operating Temperature Range | up to 40°C |
| Recommended Coverage Area | 20–35 m² (at 2.6 m ceiling height) |
| Dehumidification Capacity | 20 L/day (at 30°C, 80% RH) |
| Air Circulation Rate | 20 m³/h |
| Water Tank Capacity | 4 L |
| Input Power | 390 W |
| Net Weight | 17 kg |
| Power Supply | 220 V / 50 Hz |
| Control Interface | Digital humidity display with auto-defrost function |
| Mobility | Equipped with four swivel casters |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | A15-290 |
| Humidity Control Range | 15–60% RH |
| Humidity Accuracy | ±3% RH |
| Temperature Accuracy | ±1°C |
| Control System | Humidity Manager V2 (digital logging & curve plotting) |
| Power Supply | 220 V AC |
| Internal Dimensions (W×D×H) | 598 × 645 × 524 mm |
| External Dimensions (W×D×H) | 600 × 695 × 642 mm |
| Capacity | 202 L |
| Shelf Quantity | 2 pcs |
| Shelf Size | 555 × 580 × 20 mm |
| Avg. Power Consumption | 5 W |
| Max. Power Consumption | 140 W |
| Compliance | Designed for GLP-compliant storage environments |
| Certifications | CE-marked per IEC 61000-6-3/6-4 (EMC), RoHS compliant |
| Brand | Truelab |
|---|---|
| Origin | Tianjin, China |
| Model | AMM-6/9/12 |
| Instrument Type | Magnetic Stirrer |
| Max. Stirring Volume per Position | 0.4 L |
| Speed Range | 0–1500 rpm |
| Temperature Control Range | Ambient to 120 °C |
| Heating Power | 240 W (AMM-6T), 360 W (AMM-9T), 480 W (AMM-12T) |
| Stirring Position Spacing | 90 mm |
| Positional Speed Accuracy | ±5% |
| Plate Material | Anodized Aluminum with PTFE (Teflon®) Coating |
| Dimensions (W×H×D, mm) | AMM-6T: 278×55×498 |
| AMM-9T | 278×55×388 |
| AMM-12T | 278×55×478 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Fed. Std. 209E Class 100 @ ≥0.5 µm) |
| Airflow Pattern | Vertical Downward Laminar Flow |
| User Capacity | Single-Person, Single-Face |
| Average Air Velocity | 0.1–0.6 m/s (infinitely adjustable) |
| Microbial Contamination | ≤0.5 CFU/plate·hr (φ90 mm Petri dish) |
| Noise Level | ≤62 dB(A) |
| Illumination | ≥300 lux |
| Vibration Half-Peak Amplitude | ≤0.3 µm (X/Y/Z axes) |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 0.3 kW |
| Net Weight | 200 kg |
| Work Area Dimensions | 1570 × 480 × 570 mm (W×D×H) |
| Overall Dimensions | 1570 × 790 × 1380 mm (W×D×H) |
| HEPA Filter Specification | 549 × 1236 × 50 mm (1 unit) |
| Lighting | 30 W Fluorescent Lamp ×1 |
| UV Lamp | 40 W ×1 |
| Control Interface | LCD Display with Real-Time Parameter Monitoring (air velocity, filter status, timer, differential pressure) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | BM-400 |
| Instrument Type | Stomacher-type |
| Dimensions (W×D×H) | 390 × 220 × 310 mm |
| Sample Volume Range | 10–400 mL |
| Control Method | Digital Microprocessor |
| Display | Large LCD Screen |
| Timer Range | 0–100.0 min (or continuous mode) |
| Pulsing Frequency | 3.0–12.0 cycles/sec (adjustable) |
| Stroke Length | 0–40 mm (adjustable) |
| UV Sterilization | 254 nm, 5 min per cycle (BM-400P & BM-400HP only) |
| Temperature Control Range | Ambient to 50 °C (BM-400HP only) |
| Program Storage | 10 user-defined protocols |
| Power Consumption | 300 W |
| Electrical Supply | 220 V / 50 Hz |
| Net Weight | 21 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | BM-400HP |
| Instrument Type | Pulsed-Action (Stomacher-Type) Homogenizer |
| Dimensions (W×D×H) | 390 × 220 × 310 mm |
| Sample Volume Range | 10–400 mL |
| Temperature Control Range | Ambient to 50 °C |
| Pulsing Frequency | 3–12 pulses/s (adjustable in 0.1 increments) |
| Stroke Length | 0–40 mm (adjustable) |
| Timer Range | 0–100 min (0.1-min resolution) or Continuous Mode |
| UV Sterilization | 254 nm, 5 min per cycle |
| Display | Large LCD with Digital Keypad Interface |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 300 W |
| Net Weight | 21 kg |
| Program Memory | 10 user-defined protocols |
| Safety Features | Auto-stop door interlock, tempered glass viewing window, integrated waste collection tray |
| Construction | Full stainless-steel housing |
| Compliance | Designed for ISO 6887-1, ASTM D5659, and USP <61> microbiological sample preparation workflows |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | BPG-9070A |
| Temperature Range | RT+10°C to 300°C |
| Temperature Uniformity | ±0.5°C |
| Interior Dimensions (W×D×H) | 400×425×445 mm |
| Exterior Dimensions (W×D×H) | 545×580×800 mm |
| Interior Material | Mirror-Finish Stainless Steel |
| Heating Method | Calibrated Nichrome Wire Heater |
| Power Supply | AC 220 V, 50 Hz |
| Input Power | 1100 W |
| Volume | 80 L |
| Standard Shelves | 2 pcs |
| Timer Range | 1–9999 min |
| Temperature Resolution | 0.1°C |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model Variants | BT-100, BT-100B, BT-100D, BT-100SD, BT-200B, BT-200D, BT-200SD, D100B, D200B, BT-1FJ, BT-4F, BT-100-4, BT-100-8 |
| Flow Rate Range | 0.3–27,000 mL/h (model-dependent) |
| Maximum Output Pressure | ≥2.0–3.0 kg/cm² |
| Speed Control | 0–155 rpm (digital display, stepless adjustment) |
| Channel Configuration | 1–8 independent channels |
| Timing Function | Run/Standby timer from 1 sec to 9 h 59 min 59 sec |
| Communication Interface | RS232 (BT-100SD & select models) |
| Drive Technology | Microcontroller-based细分 drive circuitry for low noise and stable operation |
| Compliance | Designed for general laboratory fluid handling per ISO 8573-1 (compressed air purity class not applicable), compatible with GLP/GMP environments when integrated into validated systems |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | C12 / C20 / C30 |
| Power | 800 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Temperature Range | 40–120 °C |
| Temperature Accuracy | ±5 °C |
| Number of Air Jets | 12 / 20 / 30 |
| Jet Length | 170 mm / 220 mm (adjustable) |
| Dimensions (W × H) | 400 × 40 mm |
| Weight | 7–8 kg |
| Housing Material | Stainless Steel (Type C) |
| Compliance | CE-marked for laboratory use under IEC 61010-1 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | CFZ-820 |
| Type | Compressor-driven dehumidifier |
| Application | Laboratory environmental control |
| Cabinet material | Reinforced plastic housing |
| Air outlet orientation | Left-side discharge |
| Inlet | Front intake |
| Humidity control | Digital PID-based automatic humidity regulation with real-time RH display |
| Setpoint range | 30–80% RH (adjustable in 1% increments) |
| Defrost function | Automatic hot-gas defrost below 18°C ambient |
| Mobility | Four swivel casters with locking brakes |
| Safety feature | Full-tank auto-shutoff with audible/visual alarm |
| Rated dehumidification capacity | 20 L/day at 30°C / 80% RH |
| Recommended coverage | 25–35 m² (ceiling height 2.6 m) |
| Compliance | CE-marked, RoHS-compliant, meets IEC 60335-1 safety standard |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | CFZ8120 |
| Type | Compressor-Based Industrial Dehumidifier |
| Application | Laboratory Environmental Control |
| Rated Dehumidification Capacity | 120 L/day (at 30°C, 80% RH) |
| Air Circulation Rate | 120 m³/h |
| Recommended Coverage Area | 100–160 m² (ceiling height ≤ 2.6 m) |
| Operating Temperature Range | 5–40°C |
| Power Supply | 220 V / 50 Hz |
| Input Power | 1850 W |
| Dimensions (L×W×H) | 540 × 460 × 1115 mm |
| Net Weight | 60 kg |
| Compressor Type | Rotary |
| Control Method | Digital Humidity Setpoint with Real-Time Display |
| Defrost Function | Automatic (activated below 18°C ambient) |
| Drainage | Continuous via gravity hose or internal tank with auto-shutoff and audible alarm |
| Mobility | Equipped with four swivel casters (two with brakes) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | CFZ850 |
| Type | Compressor-Based Desiccant-Enhanced Laboratory Dehumidifier |
| Application | Controlled-Environment Lab Humidity Management |
| Rated Dehumidification Capacity | 50 L/day (at 30°C, 80% RH) |
| Power Input | 850 W (220 V / 50 Hz) |
| Airflow Rate | 50 m³/h |
| Tank Capacity | 8 L |
| Operating Temperature Range | 5–40°C |
| Recommended Coverage Area | 40–60 m² (with ceiling height ≤ 2.6 m) |
| Dimensions (L×W×H) | 549 × 411 × 697 mm |
| Net Weight | 31.5 kg |
| Compressor Type | Rotary |
| Control Interface | Digital Hygrostat with Real-Time RH Display & Adjustable Setpoint |
| Defrost Mode | Automatic (activated below 18°C ambient) |
| Mobility | Four Swivel Casters with Locking Brakes |
| Safety Features | Full-Tank Auto-Shutoff, Overheat Protection, Low-Temperature Defrost Logic |
| Brand | Truelab |
|---|---|
| Origin | Taiwan |
| Model | CH936B |
| Dehumidification Capacity | 36 L/day |
| Energy Efficiency Ratio | 16% above China National Standard (GB/T 2421.2–2012) |
| Operating Temperature Range | 5–35 °C |
| Applicable Area | 30 m² |
| Air Circulation Rate | 36 m³/min |
| Dimensions (L×W×H) | 650 × 350 × 600 mm |
| Water Tank Capacity | 7 L |
| Certifications | CCC (No. 2003010703054833), Performance Verification by National Household Appliance Quality Supervision & Inspection Center (No. WTS2004-1581) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | CHR-1 |
| Humidity Control Range | 20–90 %RH (±3 %RH accuracy) |
| Humidity Display Resolution | 0.1 %RH |
| Humidity Stability | ±3 %RH |
| Dual-layer Condenser Tube | Ø150 mm × 200 mm effective length |
| Condensing Surface Area | ~0.23 m² |
| Solvent Recovery Flask | 1000 mL, standard taper joint (24/29) |
| Humidifier Water Reservoir | 0.6 L |
| Humidifier Heating Power | 250 W |
| Humidifier Temperature Range | Ambient to 90 °C |
| Humidifier Temp. Display Resolution | 0.1 °C |
| Humidifier Temp. Stability | ±1 °C |
| Gas Inlet/Outlet | 1 × 8 mm barbed fitting each |
| Chilled Fluid Inlet/Outlet | 1 × 8 mm barbed fitting each |
| Communication Interface | 1 × GX16-3 connector |
| Dimensions (W×D×H) | 300 × 320 × 745 mm |
| Weight | 22.5 kg |
| Warranty | 12 months labor and parts |
| Brand | Truelab |
|---|---|
| Origin | Beijing, China |
| Model | D1008E ZeeMini |
| Instrument Type | Palm-Sized Centrifuge |
| Max. Speed | 5000 rpm |
| Max. RCF | 2680 × g |
| Capacity | 8 × 2 mL tubes |
| Rotor Type | Fixed-angle rotor |
| Motor | Brushless DC motor |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Noise Level | ≤45 dB(A) |
| Dimensions (D×W×H) | 150 × 150 × 117 mm |
| Weight | 0.5 kg |
| Safety Certification | TÜV Rheinland certified for low-voltage safety and EMC compliance |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | DB-1A / DB-2A / DB-3A / DB-1B / DB-2B / DB-3B |
| Heating Power | 600 W / 800 W / 1000 W (model-dependent) |
| Max. Operating Temperature | 250 °C |
| Temperature Uniformity | ±2 °C |
| Heating Surface Area | 300 cm² / 600 cm² / 770 cm² |
| Dimensions (L×W×H) | 200×150×100 mm / 300×200×100 mm / 350×220×100 mm |
| Control Type | Analog (A-series) or Digital LED (B-series) |
| Panel Material | 304 Stainless Steel |
| Display | LED (B-series), Mechanical Dial (A-series) |
| Brand | Truelab |
|---|---|
| Model | DK-2 |
| Power Rating | 2 kW |
| Internal Chamber Dimensions | 450 × 350 × 70 mm |
| Construction | Stainless Steel Inner Bath & Lid, Electrostatically Powder-Coated Exterior |
| Internal Recirculation | None (Dry Heat Transfer via Sand Medium) |
| Compliance | Designed for General Laboratory Use per GB/T 28961–2012 (Laboratory Equipment — Safety Requirements) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | DL-1 |
| Power Options | 1 kW (Single Station), 2 kW (Single Station), 2×1 kW (Dual Station), 4×1 kW (Quad Station), 6×1 kW (Hex Station) |
| Heating Power | 1000 W / 2000 W / 2000 W / 4000 W / 6000 W |
| Max Operating Temperature | 300 °C |
| Temperature Uniformity | ±10 °C |
| Plate Surface Dimensions | 200 mm × 200 mm |
| Heating Zone Diameter | 100 mm |
| Display Type | Analog Dial Gauge |
| Construction | Cold-Rolled Steel Housing with Electrostatic Powder Coating |
| Heating Element Type | Enclosed Resistive Coil |
| Control Method | Phase-Angle SCR Power Regulation |
| Voltage | 220 V AC, 50 Hz |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Drum Collector 300–3600 rpm |
| Motor | Brushless DC High-Speed Motor |
| Speed Range | 300–3600 rpm ±20 rpm |
| Drum Material | AISI 304 Stainless Steel |
| Drum Dimensions | Ø102 mm × L200 mm |
| Base Material | Phenolic Resin (Bakelite), Electrically Insulated |
| Base Dimensions | W520 × D388 × H20 mm |
| Overall Dimensions | W520 × D388 × H135 mm |
| Weight | 18 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | DZKW-D-1 (Single-Well, Single-Row) |
| Rated Power | 300 W |
| Heating Power | 2000 W |
| Temperature Range | RT+10°C to 100°C |
| Temperature Uniformity | ≤ ±1°C |
| Temperature Fluctuation | ≤ ±1°C |
| Control Accuracy | ±2°C |
| Display Error | ≤ ±2°C |
| Bath Volume | 2 L |
| Tank Dimensions (W×D×H) | 160 × 170 × 90 mm |
| External Dimensions (W×D×H) | Not specified |
| Voltage/Frequency | 220 V / 50 Hz |
| Construction | Stainless steel inner tank and lid, electrostatically sprayed exterior |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model Range | 100 mL – 20 L capacities |
| Heating Power | 150–2500 W (model-dependent) |
| Max Operating Temperature | 200 °C |
| Temperature Uniformity | ±0.1 °C |
| Heating Surface Diameter | 100 mm |
| Heating Zone Diameter | 100 mm |
| Display Type | Analog Dial Thermometer |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | ER-30 / ER-30F / ER-35F |
| Heating Power | 1200 W (ER-30/ER-30F), 2400 W (ER-35F) |
| Max. Operating Temperature | 450 °C (ER-30, 30 s transient), 400 °C (ER-30F, continuous) |
| Heating Surface Dimensions | 300 × 300 mm (ER-30/ER-30F), 300 × 500 mm (ER-35F) |
| Overall Dimensions (W×D×H) | 300 × 355 × 125 mm (ER-30/ER-30F), 500 × 355 × 125 mm (ER-35F) |
| Temperature Display | Digital LED |
| Construction | Microcrystalline glass top plate, 316L stainless steel housing, ceramic fiber insulation |
| Temp. Uniformity | ±5 °C across heating surface (at 400 °C, steady state) |
| Input Voltage | AC 220 V, 50 Hz |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | FD-1A-50 |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application | Laboratory-Scale Lyophilization |
| Freeze-Drying Area | 0.12 m² |
| Ultimate Vacuum | < 20 Pa |
| Condenser Temperature | −50 °C |
| Water Capture Capacity | 3 kg/24 h |
| Condenser Dimensions | Stainless Steel, Open-Top Design with Pre-Freezing Capability |
| Shelf Configuration | 4 Adjustable Stainless Steel Trays (Φ200 mm) |
| Tray Capacity | ~1.2 L (at 10 mm sample depth) |
| Power Supply | 220 V, 50 Hz, 850 W |
| Unit Dimensions | 380 × 600 × 345 mm |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Software Interface | Digital Vacuum & Temperature Display (Optional Sample Temperature Monitoring) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | FD-1B-50 / FD-1B-80 |
| Type | Stoppering Benchtop Freeze Dryer |
| Application | Laboratory-Scale Lyophilization |
| Shelf Area | 0.07 m² |
| Ultimate Vacuum | < 20 Pa |
| Condenser Temperature | −50 °C (FD-1B-50) / −80 °C (FD-1B-80) |
| Ice Capacity | 3 kg/24 h (FD-1B-50) / 4 kg/24 h (FD-1B-80) |
| Sample Tray | Φ180 mm × 3 layers |
| Dimensions (W×D×H) | 380×600×345 mm (FD-1B-50) / 492×540×800 mm (FD-1B-80) |
| Power Supply | 220 V, 50 Hz, 850 W (FD-1B-50) / 1300 W (FD-1B-80) |
| Standard Configuration | Benchtop主机, 2 L Domestic Vacuum Pump, Stoppering Drying Chamber with Three Φ180 mm Stainless Steel Trays |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Fine-Rod Collector |
| Rotational Speed Range | 0–1000 rpm ±1 rpm |
| Motor | 57-step Hybrid Stepper Motor |
| Rod Material | AISI 304 Stainless Steel |
| Standard Rod Dimensions | Ø2.5 mm × L100 mm (customizable in diameter and length) |
| Base Material | Phenolic Resin (Bakelite) |
| Base Dimensions | 450 mm W × 200 mm D × 20 mm H |
| Overall Dimensions | 450 mm W × 200 mm D × 135 mm H |
| Weight | 10 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | FP-25 |
| Chamber Dimensions | 200 × 120 × 80 mm |
| Max Temperature | 1000 °C |
| Temperature Uniformity | ±2.5 °C |
| Rated Power | 2.5 kW |
| Voltage/Frequency | 220 V / 50 Hz |
| Heating Method | Ceramic Fiber Insulation |
| Weight | Lightweight Design |
| Compliance | CE-marked per IEC 61000-6-3 & IEC 61000-6-4 (EMC), EN 60519-1 (Electrical Safety for Industrial Electroheating Equipment) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FP-40 |
| Chamber Dimensions (W×D×H) | 300 × 200 × 120 mm |
| Internal Volume | 7.2 L |
| Max Operating Temperature | 1000 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Power | 4 kW |
| Heating Method | Ceramic Fiber Insulation |
| Power Supply | 220 V / 50 Hz |
| Furnace Type | Box-Type Muffle Furnace |
| Weight | Lightweight Design for Mobility |