Environmental Test Chamber
Filter
Showing 2941–2970 of 3644 results
| Brand | Qigao Instruments (SHQIGAO) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-510G-4 |
| Temperature Range | –50 °C (dual-bath isothermal operation), ±1 °C accuracy |
| Temperature Stability | ±0.5 °C |
| Temperature Uniformity | ≤2 °C across bath volume |
| Cooling Rate | 0.7–1 °C/min |
| Heating Rate | 1–3 °C/min |
| Temperature Resolution | 0.1 °C |
| Control Accuracy | ±0.1 °C (display), ±1 °C (setpoint maintenance) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 1500 W |
| Ambient Operating Conditions | ≤30 °C, ≤85% RH |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCK-350 |
| Temperature Range | -70°C to +150°C |
| Refrigeration Method | Compressor-based Cooling |
| Temperature Fluctuation | ±0.5°C |
| Temperature Uniformity | ±2.0°C |
| Temperature Deviation | ±2.0°C |
| Heating Rate | ≤60 min (-20°C to 100°C) |
| Cooling Rate | ≤45–80 min (20°C to -40°C) |
| Internal Chamber Dimensions | Customizable per test requirement |
| Humidity Range | 10%–99.9% RH |
| Humidity Resolution | 0.01% RH |
| Temperature Resolution | 0.01°C |
| Programmable Steps | 120 programs / 1200 segments |
| Humidity Accuracy | ±2.5% RH |
| Temperature Accuracy | ±0.5°C |
| Humidity Uniformity | ±3.0% RH |
| Power Supply | 220 V AC |
| Rated Power | 2.0 kW |
| Net Weight | ~180 kg |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCK-350 |
| Temperature Range | −40 °C to +150 °C |
| Humidity Range | 10 %RH to 99.9 %RH |
| Temperature Resolution | 0.01 °C |
| Humidity Resolution | 0.01 %RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 %RH |
| Temperature Accuracy | ±0.5 °C |
| Humidity Accuracy | ±2.5 %RH |
| Programmable Steps | 120 programs / 1200 segments |
| Internal Dimensions (H×W×D) | 450 × 400 × 350 mm |
| External Dimensions (H×W×D) | 1550 × 920 × 820 mm |
| Power Supply | 220 V AC |
| Rated Power | 2.0 kW |
| Net Weight | ~180 kg |
| Configuration | Vertical upright chamber |
| Compliance | Designed for ISO 5725 (accuracy & reproducibility), ASTM E145 (standard practice for gravity-convection and forced-ventilation ovens), and GB/T 2423.3–2016 (IEC 60068-2-78) for damp heat testing |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCK-350 |
| Temperature Range | −40 °C to +150 °C |
| Humidity Range | 10 %RH to 99.9 %RH |
| Temperature Resolution | 0.01 °C |
| Humidity Resolution | 0.01 %RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 %RH |
| Temperature Accuracy | ±0.5 °C |
| Humidity Accuracy | ±2.5 %RH |
| Ramp Rates | 30 min (−20 °C → 100 °C), 35 min (20 °C → −40 °C) |
| Interior Dimensions (H×W×D) | 450×400×350 mm |
| Exterior Dimensions (H×W×D) | 1550×920×820 mm |
| Power Supply | 220 V AC |
| Rated Power | 2.0 kW |
| Net Weight | ~180 kg |
| Programmable Cycles | 120 programs / 1200 segments |
| Compliance | Designed for ISO 17025-aligned laboratory environments |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCK-395A |
| Chamber Type | Integrated High-Low Temperature + Water Immersion (Cold/Hot Water Spray & Thermal Cycling) |
| Compliance | GB/T 28046.4–2011, VW 80000:2009–10 |
| Application Scope | Automotive Component Validation, Aerospace Sealing Integrity Testing, IPX9K-Grade Enclosure Evaluation, GLP/GMP-Compliant Environmental Reliability Assessment |
| Temperature Range | –40 °C to +150 °C (typical standard configuration) |
| Water Spray Parameters | Adjustable flow rate (14–16 L/min), nozzle pressure 8–10 MPa, water temperature controllable from 5 °C to 85 °C |
| Internal Volume | 395 L |
| Control Accuracy | ±0.5 °C (temperature), ±3% RH (when humidification enabled) |
| Cooling/Heating Rate | ≥3 °C/min (average, 25 °C to –40 °C), ≥2 °C/min (25 °C to +150 °C) |
| Structural Material | Inner chamber — SUS316L stainless steel |
| Safety Features | Over-temperature cut-off, high-pressure water leakage detection, emergency stop with mechanical interlock, dual-circuit water supply monitoring |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCK-395A |
| Temperature Range | −45 °C to +150 °C |
| Compliance | GB/T 28046.4–2011, VW 80000:2009-10 |
| Application Scope | Automotive, Aerospace, Electronics, Appliance Reliability Testing |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCK-562A |
| Chamber Type | Upright |
| Cooling Method | Air-cooled |
| Temperature Range | -40 °C to +150 °C |
| Humidity Range | 30–98 %RH |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ±1 °C (high temp), ±2 °C (low temp) |
| Humidity Uniformity | ≤ ±2 %RH |
| Humidity Fluctuation | ±2 %RH |
| Internal Dimensions (W×D×H) | 450×400×350 mm |
| Power Supply | 220 V AC |
| Rated Power | 2.0 kW |
| Net Weight | ~180 kg |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | QJXDW3541 |
| Price Range | USD 5,600 – 28,000 (FOB Shanghai) |
| Light Source | 6 kW Air-Cooled or Water-Cooled Xenon Arc Lamp |
| Spectral Range | 290–800 nm |
| Irradiance Control | Adjustable, Displayed in Real Time (300–800 nm @ 550 W/m² nominal) |
| Temperature Range | RT+10°C to 80°C ±1°C |
| Temp Uniformity | ≤2°C |
| Sample Rotation | 5 rpm, Dual-Radial Fixture (Inner Ø100 mm / Outer Ø220 mm), Center Distance 165 mm, Height 420 mm |
| Chamber Dimensions (W×D×H) | 500×500×600 mm (standard) |
| Rainfall Duration | 0–9999 min (adjustable) |
| Rainfall Cycle Interval | 0–240 min (adjustable) |
| Cooling Method | Air-cooled (3 kW) or Water-cooled (4.5 kW) |
| Lamp Lifetime | Approx. 2000 h |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJXDW3541 |
| Lamp Power | 6 kW |
| Temperature Range | RT+10°C to 80°C ±1°C (adjustable) |
| Humidity Range | RT+10°C to 80°C ±1°C (adjustable) |
| Spectral Range | 290–800 nm |
| Irradiance | 550 W/m² (300–800 nm) |
| Sample Rack Rotation Speed | 5 rpm |
| Interior Chamber Dimensions | 500 × 500 × 600 mm |
| Rainfall Duration | 0–9999 min (adjustable) |
| Rainfall Cycle Interval | 0–240 min (adjustable) |
| Lamp Life | ~2000 h |
| Cooling Method | Air-cooled (3 kW) / Water-cooled (4.5 kW) |
| Lamp Voltage/Current | 220 V ±5%, 20 A |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJYS-70 |
| Price | USD 2,800 (FOB Shanghai) |
| Internal Chamber Dimensions (Min–Max) | 600 × 450 × 400 mm to 1600 × 1000 × 500 mm |
| External Dimensions (Min–Max) | 1075 × 630 × 1185 mm to 2300 × 1200 × 1485 mm |
| Chamber Volume (Min–Max) | 108 L to 800 L |
| Salt Solution Reservoir Capacity (Min–Max) | 15 L to 40 L |
| Test Standards Compliance | GB/T 2423.17 (Neutral Salt Spray), GB/T 2423.18 (Acetic Acid Salt Spray), ASTM B117, ISO 9227, JIS Z2371 |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QUV1003 (Spray-type) |
| Illumination Temperature Range | 50, 60, 70 °C |
| Black Panel Temperature Range | 50, 60, 70 °C |
| UV Wavelength Range | 280–315 nm (UV-B) |
| Internal Chamber Dimensions (L×W×H) | 450 × 1165 × 500 mm |
| Temperature Uniformity | ±3 °C |
| Humidity During Condensation | ≥75 %RH |
| Cycle Options | 4 h UV irradiation + 4 h condensation or 8 h UV + 4 h condensation |
| Lamp Center-to-Center Spacing | 65–70 mm |
| Specimen-to-Lamp Distance | 55 mm |
| Standard Specimen Size | 75 × 150 mm |
| Water Consumption | 8 L/day (deionized or distilled water required) |
| External Dimensions (D×W×H) | 600 × 1325 × 1480 mm |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QUV1003 |
| Irradiance Range | 0.72 W/m² (at 313 nm) |
| Cycle Options | 4 h UV irradiation + 4 h condensation OR 8 h UV irradiation + 4 h condensation |
| Illumination Temperature Range | RT+10°C to 70°C |
| Black Panel Temperature Range | RT+10°C to 70°C |
| UV Spectrum | UV-B, 280–315 nm |
| Chamber Internal Dimensions (L×W×H) | 450 × 1165 × 500 mm |
| Temperature Uniformity | ±3°C |
| Relative Humidity During Condensation | ≥75% RH |
| Specimen-to-Lamp Distance | 55 mm |
| Lamp Center Spacing | 65–70 mm |
| Standard Specimen Size | 75 × 150 mm |
| Water Consumption | ~8 L/day (deionized or distilled water required) |
| External Dimensions (D×W×H) | 600 × 1325 × 1480 mm |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QUV1003 (Spray-Type) |
| Temperature Range | RT+10°C to 70°C |
| Temperature Uniformity | ±3°C |
| Humidity Range | ≥75% RH |
| Irradiation Cycle Options | 4h UV / 4h Condensation or 8h UV / 4h Condensation |
| UV Lamp Type | UV-B (280–315 nm) |
| Lamp Center-to-Center Spacing | 65–70 mm |
| Sample-to-Lamp Distance | 55 mm |
| Standard Specimen Size | 75 × 150 mm |
| Water Consumption | 8 L/day (deionized or distilled water required) |
| Internal Chamber Dimensions (D×W×H) | 450 × 1165 × 500 mm |
| Overall Dimensions (D×W×H) | 600 × 1325 × 1480 mm |
| Compliance | GB/T 14522–1993 |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QUV1003 |
| Illumination Temperature Range | RT+10°C to 70°C |
| Black Panel Temperature Range | RT+10°C to 70°C |
| UV Wavelength Range | 280–315 nm (UV-B) |
| Chamber Internal Dimensions (L×W×H) | 450 × 1165 × 500 mm |
| Temperature Uniformity | ±3°C |
| Humidity During Condensation | ≥75% RH |
| Cycle Options | 4 h UV irradiation + 4 h condensation or 8 h UV + 4 h condensation |
| Lamp Center-to-Center Spacing | 65–70 mm |
| Specimen-to-Lamp Distance | 55 mm |
| Standard Specimen Size | 75 × 150 mm |
| Water Consumption | ~8 L/day (deionized or distilled water required) |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QUV1003 (Spray-type) |
| Illumination Temperature Range | RT+10°C to 70°C |
| Black Panel Temperature Range | RT+10°C to 70°C |
| UV Wavelength | 280–315 nm (UV-B) |
| Chamber Internal Dimensions (L×W×H) | 450 × 1165 × 500 mm |
| Temperature Uniformity | ±3°C |
| Humidity During Condensation | ≥75% RH |
| Cycle Options | 4h UV irradiation / 4h condensation or 8h UV / 4h condensation |
| Lamp Center-to-Center Spacing | 65–70 mm |
| Specimen-to-Lamp Distance | 55 mm |
| Standard Specimen Size | 75 × 150 mm |
| Water Consumption | 8 L/day (deionized or distilled water required) |
| External Dimensions (D×W×H) | 600 × 1325 × 1480 mm |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Qingji SCY-1215 |
| Price | USD 7,800 (FOB Shanghai) |
| Compliance | GB/T 4208–2017, GB/T 4942.1–1993, IEC 60529:2013 (equivalent) |
| Chamber Interior Dimensions | 800 × 800 × 800 mm (D×W×H) |
| External Dimensions | 1100 × 1300 × 1700 mm (D×W×H) |
| Oscillating Pipe Radius | 400 mm |
| Nozzle Quantity | 25 |
| Nozzle Diameter | Ø0.4 mm |
| Nozzle Spacing | 50 mm |
| Pipe Diameter | Ø16 mm |
| Water Flow Rate per Nozzle | 0.07 L/min |
| Total Flow Rate | ~1.8 L/min |
| Oscillation Angle | ±60° (120° total sweep) |
| Cycle Time per Full Oscillation | ~12 s |
| Timer Range | 00:00:00 to 99:59:59 (h:mm:ss) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Interior Material | SUS304 2B stainless steel |
| Exterior Enclosure | Cold-rolled steel with anti-rust pretreatment and electrostatic powder coating |
| Sample Tray | Custom stainless steel tray with precision-drilled drainage holes |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ-AGE Series |
| Temperature Range | RT+20°C to 300°C |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Heating Rate | ≤60 min (from RT+20°C to 200°C) |
| Total Power Consumption | 6.7 kW (Heating: 6 kW |
| Auxiliary Systems | 0.7 kW) |
| Noise Level | ≤65 dB(A) |
| Compliance | IEC 60540 (Ed. 2.0, 2019), ASTM D573, ISO 188, GB/T 2951.12–2008 |
| Control System | Imported Digital PID Controller with Dual-Air-Channel Circulation Architecture |
| Safety Features | Dual Independent Overtemperature Cut-off (Electrical & Optical), Redundant Thermal Fuse Protection |
| Brand | Qinji |
|---|---|
| Model | QJ-CK |
| Origin | Shanghai, China |
| Temperature Range | −40 °C to +150 °C |
| Humidity Range | 10 %RH to 99.9 %RH |
| Temperature Uniformity | ±2.0 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Uniformity | ±3.0 %RH |
| Humidity Accuracy | ±2.5 %RH |
| Resolution | 0.01 °C / 0.01 %RH |
| Programmable Steps | 120 programs, up to 1200 segments |
| Internal Chamber Dimensions (H×W×D) | 450 × 400 × 350 mm |
| External Dimensions (H×W×D) | 1550 × 920 × 820 mm |
| Power Supply | 220 V AC |
| Rated Power | 2.0 kW |
| Net Weight | ~180 kg |
| Cooling Method | Mechanical compression refrigeration |
| Heating/Cooling Rate | 30 min (−20 °C → +100 °C), 35 min (+20 °C → −40 °C) |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ-YS |
| Spray Mode | Continuous Atomization |
| Chamber Volume Range | 108–800 L |
| Salt Solution Tank Capacity | 15–40 L |
| Operating Temperature Range | Ambient to ≥65 °C |
| Compliance | GB/T 2423.17 (Neutral Salt Spray), ASTM B117, ISO 9227 (Acetic Acid Salt Spray option available) |
| Manufacturer Status | Domestic OEM Manufacturer |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCK395A |
| Type | Integrated Ice-Water Immersion / Temperature-Humidity Cycling Chamber |
| Compliance | GB/T 28046.4–2011, VW 80000:2009-10 |
| Application Scope | Automotive components, aerospace hardware, consumer electronics, and industrial electrical enclosures |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCLR8731 |
| High-Temperature Zone Range | 60–200 °C |
| Low-Temperature Zone Range | −10 to −65 °C (standard), optional −75 °C |
| Test Chamber Operating Range | −10 to −60 °C (standard), optional −50 °C or −60 °C |
| Temperature Stability | ±1 °C |
| Temperature Uniformity | ±2 °C |
| Recovery Time | ≤5 min |
| Heating Rate (typical) | 40 min (from −65 °C to +200 °C) |
| Cooling Rate (typical) | 60–90 min (from +200 °C to −65 °C) |
| Controller | 7.5″ color LCD touchscreen with bilingual (English/Chinese) interface, 256-color display, adjustable backlight, direct-key operation |
| Safety Protections | Fuseless circuit breaker, compressor high-pressure/overheat/overcurrent protection, chamber overtemperature protection, fan overload protection |
| Standard Accessories | Two sample racks, one 50 mm diameter cable port |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCLR8731 |
| High-Temperature Range | +80 °C to +200 °C |
| Low-Temperature Range | −10 °C to −70 °C (optional: −65 °C or −75 °C) |
| Thermal Shock Zone | +60 °C to +150 °C (hot zone), −10 °C to −40 °C (cold zone) |
| Temperature Stability | ±2 °C |
| Temperature Uniformity | ±2 °C |
| Recovery Time | 5 min |
| Heating Time | 40 min |
| Cooling Time | 60–90 min |
| Controller | 7.5″ color LCD touchscreen with bilingual (Chinese/English) interface |
| Safety Protections | Fuseless circuit breaker, compressor high-pressure/overheat/overcurrent protection, overtemperature cutoff, fan overload protection |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCXS-43 |
| Test Temperature Range | −70 °C to 0 °C |
| Impact Velocity | 2 m/s ±0.2 m/s |
| Temperature Stability During Test (3 min) | ±0.5 °C |
| Impact Head to Clamp Distance | 11 mm ±0.5 mm |
| Dimensions (W×D×H) | 700 mm × 700 mm × 1300 mm |
| Power Consumption | 1100 W |
| Compliance | GB/T 1682–2014 (revised edition of GB 1682–1982) |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJCYX-54 |
| Price Range | USD 4,900 – 7,000 |
| Temperature Range | 0°C to 60°C |
| Humidity Range | 40–98% RH (at 30–60°C) |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Stability | ≤ ±0.5°C |
| Humidity Stability | +2 / −3% RH |
| Heating Rate | 0.7–1.0°C/min |
| Cooling Rate | ≤20 min (from ambient to 10°C, non-restricted) |
| Ozone Concentration Range | 10–1,000 pphm |
| Gas Flow Velocity | 12–16 mm/s |
| Sample Mounting | Static Rack |
| Compliance | GB/T 7762–2003, GB/T 3642–1992 |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCYX-542 |
| Temperature Range | 0–60 °C |
| Humidity Range | 40–98% RH (at 30–60 °C) |
| Temperature Uniformity | ≤±2 °C |
| Temperature Stability | ≤±0.5 °C |
| Humidity Stability | +2 / −3% RH |
| Heating Rate | 0.7–1.0 °C/min |
| Cooling Rate | ≤20 min (from ambient to 10 °C, non-restricted) |
| Ozone Concentration Range | 10–1000 pphm |
| Gas Flow Velocity | 12–16 mm/s |
| Compliance | GB/T 7762–2003, GB/T 3642–1992 |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJSE-1 |
| Temperature Range | RT+20°C to 300°C |
| Max Operating Temperature | 400°C (short-term) |
| Temperature Uniformity | ≤±2.0°C (within 60 min at 200°C) |
| Temperature Fluctuation | ≤±0.5°C |
| Temperature Deviation | ≤±2.0°C |
| Heating Rate | RT+20°C → 200°C in ≤60 min |
| Total Power Consumption | 6.7 kW (Heating: 6.0 kW |
| Auxiliary Systems | 0.7 kW) |
| Internal Chamber Dimensions (W×H×D) | 500×500×600 mm |
| Noise Level | ≤65 dB(A) |
| Compliance | IEC 60540 (formerly IEC 540), ASTM D3045, ISO 188, UL 1581 Section 1000 |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJSE-1 |
| Temperature Range | RT+20 °C to 300 °C |
| Temperature Uniformity | ≤±2 °C (at steady state) |
| Temperature Fluctuation | ≤±0.5 °C |
| Heating Rate | RT+20 °C to 200 °C in ≤60 min |
| Air Exchange Rate | Adjustable, compliant with IEC 60540 requirements |
| Chamber Dimensions | Customizable (W×H×D) |
| Total Power Consumption | ~6.7 kW (Heating: 6 kW |
| Auxiliary Systems | 0.7 kW) |
| Noise Level | ≤65 dB(A) |
| Compliance | IEC 60540, ASTM D573, ISO 188, GB/T 3512 |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | QJXDW3541 |
| Price | Upon Request |
| Light Source | 6 kW Air-Cooled/Water-Cooled Xenon Arc Lamp |
| Spectral Range | 290–800 nm |
| Irradiance (300–800 nm) | 550 W/m² |
| Temperature Range | RT+10°C to 80°C ±1°C |
| Temp. Uniformity | ≤2°C |
| Sample Rack Radius (inner/outer) | 100/220 mm |
| Rack Rotation Speed | 5 rpm |
| Center Distance to Lamp | 165 mm |
| Rack Height | 420 mm |
| Chamber Dimensions (W×D×H) | 500×500×600 mm |
| Rainfall Duration | 0–9999 min (adjustable) |
| Rainfall Cycle Interval | 0–240 min (adjustable) |
| Irradiance Monitoring & Integrated Dose Display | Yes |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJXDW3541 |
| Lamp Power | 4.5 kW (water-cooled) |
| Temperature Range | RT+10°C to 80°C ±1°C |
| Humidity Range | Not specified (condensation-based humidity simulation only) |
| Spectral Range | 290–800 nm |
| Radiant Intensity | 550 W/m² (300–800 nm) |
| Sample Rotation Speed | 5 rpm |
| Chamber Interior Dimensions | 500 × 500 × 600 mm |
| Rainfall Duration | 0–9999 min (adjustable) |
| Rainfall Cycle Interval | 0–240 min (adjustable) |
| Lamp Lifetime | ~2000 h |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QUV1003 (Spray-Type) |
| Temperature Range | RT+10°C to 70°C |
| Temperature Uniformity | ±3°C |
| Humidity Range | ≥75% RH |
| Illumination Temperatures | 50°C / 60°C / 70°C (60°C recommended) |
| Condensation Temperature | 50°C (±3°C) |
| Cycle Options | 4h UV / 4h Condensation or 8h UV / 4h Condensation |
| UV Lamp Type | UV-B (280–315 nm) |
| Lamp Center-to-Center Spacing | 65–70 mm |
| Specimen-to-Lamp Distance | 55 mm |
| Standard Specimen Size | 75 × 150 mm |
| Water Consumption | 8 L/day (deionized or distilled water required) |
| Interior Dimensions (D×W×H) | 450 × 1165 × 500 mm |
| External Dimensions (D×W×H) | 600 × 1325 × 1480 mm |