Empowering Scientific Discovery

Fischer Test Instruments (China) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelXDLM
Measurement PrincipleEnergy-Dispersive X-ray Fluorescence (EDXRF)
Sample PositioningMotorized Z-axis (standard)
Collimators4 interchangeable (diameters: 0.1, 0.2, 0.3, 0.5 mm)
Primary Filters3 interchangeable Al, Cu, Ti
DetectorProportional counter with high-count-rate capability
Measurement Distance0–80 mm (adjustable via motorized Z-axis)
Optical AlignmentIntegrated high-resolution color CCD camera with 10× digital zoom
Operating Temperature10–40 °C
Relative Humidity≤95% RH (non-condensing)
Instrument Weight100–120 kg
PC InterfacePCI/PCIe expansion slot required for spectrometer control and data acquisition
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelHM500
ComplianceDIN EN ISO 14577-1, DIN EN ISO 14577-2, DIN 50359
Measurement PrincipleContinuous Stiffness Measurement (CSM) & Depth-Sensing Indentation
Load Range0.1 mN – 1000 mN
Depth Resolution≤ 0.05 nm (sub-pm interpolation capability)
Load Resolution≤ 10 nN
Indenter TypesVickers (136° diamond pyramid), Berkovich (115.2° trihedral pyramid), spherical diamond (R = 1 µm to 100 µm)
Stiffness Measurement ModeEnhanced Stiffness Profiling (ESP)
Data Acquisition RateUp to 1 kHz
Environmental StabilityActive temperature compensation (±0.1 °C)
Software ComplianceFDA 21 CFR Part 11 ready, GLP/GMP audit trail enabled
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelMP0/MP0R
Measurement PrincipleDual-mode electromagnetic induction (for ferrous substrates) and eddy current (for non-ferrous substrates)
DisplayDual independent pivotable LCD screens with backlight
HousingIP65-rated ruggedized enclosure
ProbeWear-resistant integrated probe
Compliance ModesIMO PSPC, SSPC-PA2
Operating Temperature−10 °C to +50 °C
Battery LifeUp to 30,000 measurements per charge (standard alkaline AA batteries)
Data OutputUSB interface for PC transfer
CalibrationFactory-calibrated with traceable NIST-equivalent reference standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelXDLM Series
Measurement PrincipleEnergy-Dispersive X-Ray Fluorescence (ED-XRF)
Standards ComplianceDIN 50987, ISO 3497, ASTM B568
X-Ray TubeMicrofocus, adjustable high voltage (30/40/50 kV)
Collimator SetCircular (0.1 / 0.2 / 0.3 mm) and rectangular (0.05 × 0.3 mm)
Sample Chamber Dimensions (W×D×H)570 × 740 × 650 mm
Internal Chamber Volume (W×D×H)460 × 500 × 300 mm
Z-Axis Travel Range144 mm (motorized)
Camera SystemIntegrated color CCD camera with live imaging and on-screen crosshair overlay
Beam Spot VisualizationReal-time X-ray beam size indicator synchronized with focal distance
Distance Correction MethodDCM (Distance Control Measurement), effective up to 80 mm
Software PlatformWinFTM® v6 (Windows-based, 32-bit), multilingual UI (EN/DE/FR/IT/ES/ZH)
Data InterfaceRS-232, Ethernet-compatible remote command protocol
Reporting & SPCEmbedded statistical engine with control charts (X̄/R, X̄/S), probability plots, histogram analysis, and customizable PDF/Excel report generation
Regulatory SupportAudit trail, user access levels, electronic signature readiness per FDA 21 CFR Part 11 and GLP/GMP requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelRMP30-S
Measurement PrincipleMicro-resistive Method per EN 14571:2004
DisplayDual-line, 16-character LCD (2 × 16)
Memory CapacityUp to 100 application setups
Data StorageUp to 10,000 measurements across 1,000 data blocks with timestamp (date/time stamping)
InterfaceBidirectional RS232 port
Probe RecognitionAutomatic probe identification
Audio FeedbackAudible limit alarm
Statistical FunctionsMean, Std. Dev., Min/Max, Cp/Cpk, histogram generation
Compatible ProbesERCU-N, ERCU-D10
Power SupplyRechargeable battery or AC adapter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelXULM Series
Measurement PrincipleEnergy-Dispersive X-Ray Fluorescence (ED-XRF)
Standards ComplianceDIN 50987, ISO 3497, ASTM B568
X-Ray TubeMicrofocus, adjustable high voltage (30/40/50 kV)
Collimator OptionsØ0.1 mm / Ø0.2 mm circular
Sample Chamber Dimensions (W×D×H)375 × 580 × 480 mm
Internal Chamber Dimensions (W×D×H)360 × 460 × 240 mm
Manual X-Y Stage Travel50 mm (X) × 50 mm (Y)
Stage Platform Size360 × 240 mm
Viewing SystemIntegrated color CCD camera with real-time zoom and auto-focus
Beam AlignmentOn-screen calibrated crosshair + dynamic X-ray beam size indicator
Software PlatformWinFTM® v6 (Win32 native, multilingual UI)
ReportingEmbedded sample image capture, SPC charts (X̄/R, X̄/S), probability plots, histogram analysis
Regulatory SupportAudit trail, user access levels, electronic signature readiness per FDA 21 CFR Part 11 & GLP/GMP requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelHM2000S
Instrument TypeMicrohardness Tester
ComplianceDIN EN ISO 14577
Measurement PrincipleInstrumented Indentation Testing (IIT)
Key Output ParametersMartens Hardness (HM), Indentation Hardness (HIT), Indentation Modulus (EIT), Indentation Creep (CIT), Elastic Work Ratio (ηIT), Depth- and Load-Dependent Property Mapping via ESP Mode
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelXDV-SDD
Form FactorBenchtop
Elemental RangeAl (Z=13) to U (Z=92)
Detection Limit1 ppm
Quantification Range1 ppm – 100 wt%
Energy Resolution≤140 eV (Mn Kα)
Repeatability≤5% RSD
Sample StageMotorized XYZ with Programmable XY Translation and Z-Axis Lift
X-ray SourceMicrofocus Tungsten Anode Tube with Beryllium Window
High Voltage3-step Adjustable (up to 50 kV)
Filter Options6 Interchangeable Primary Filters
CollimatorsMotorized, Switchable Apertures
Optical AlignmentIntegrated HD Video System with 20× Digital Zoom, Crosshair Overlay, and Laser Spot Locator
Software PlatformWinFTM® v8.x (FDA 21 CFR Part 11 Compliant, Audit Trail Enabled, GLP/GMP-Ready)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelFMP100 / FMP150
Measurement PrincipleMagnetic Induction (for ferrous substrates) & Eddy Current (for non-ferrous substrates)
Operating SystemWindows CE
DisplayHigh-Resolution Graphical Touchscreen
Onboard MemorySupports >10,000 measurements
Compliance ModesIMO PSPC, SSPC-PA2, QUALANOD, QUALICOAT
Probe InterfaceInterchangeable probe design
Data ManagementCompatible with DataCenter IP inspection planning software
Regulatory ContextDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelSIGMASCOPE SMP350
Measurement PrinciplePhase-Sensitive Eddy Current Method
ComplianceDIN EN 2004-1, ASTM E1004
Frequency Range15 kHz to 1 MHz
Calibration StandardsTraceable to International Reference Standards (MS/m and %IACS)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelXUL220
Measurement PrincipleEnergy-Dispersive X-Ray Fluorescence (ED-XRF)
Detector TypeProportional Counter
Count Rate CapabilityHigh
Imaging SystemHigh-Resolution Color CCD Camera with Manual Focus and Adjustable LED Illumination
Sample Chamber DimensionsExtra-Large (Enabling Large-Part Measurement)
StageManual XY Translation Stage
Operating Temperature10–40 °C
Relative Humidity≤95% RH (Non-Condensing)
ComplianceDesigned for ISO 3497, ASTM B568, DIN 50982, and RoHS/WEEE Screening Applications
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelXDL-B Series
Measurement PrincipleEnergy-Dispersive X-Ray Fluorescence (ED-XRF)
Standards ComplianceDIN 50987, ISO 3497, ASTM B568
X-ray Tube VoltageAdjustable up to 50 kV
Collimator Options0.3 mm Ø standard
Measurement Chamber Dimensions (H×W×D)650 × 570 × 740 mm
Chamber Internal Dimensions (H×W×D)300 × 460 × 500 mm
Mass~105 kg
Viewing SystemIntegrated color CCD camera with real-time zoom and focus control
Distance Control MethodDCM (Distance Correction Method) for automated spectral intensity compensation across 3 fixed source-to-sample distances (standard: mid-position)
Sample Height AdjustmentFixed-height X-ray head with removable support plate for oversized parts
InterfaceRS-232, Ethernet-ready for remote command control
Software PlatformNative Win32 application for Windows 2000/XP
Language SupportEnglish, German, French, Italian, Spanish, Chinese
Reporting & SPCEmbedded statistical engine with SPC charts, probability plots, histogram analysis, and customizable report generation including annotated sample images
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelXAN500
Detector TypeSilicon Drift Detector (SDD)
Measurement PrincipleEnergy-Dispersive X-ray Fluorescence (ED-XRF)
PortabilityHandheld & Benchtop-Convertible Configuration
ComplianceCE, RoHS, ISO 3497, ASTM B568, DIN EN ISO 3497, ISO 2178 (for magnetic substrates), ISO 2360 (for non-magnetic substrates)
SoftwareWinFTM® v8.x with GLP/GMP-compliant audit trail, FDA 21 CFR Part 11 optional module
Price RangeUSD 25,000 – 65,000 (FOB Hamburg)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelMP10E
Measurement PrincipleElectromagnetic Induction (DIN EN ISO 2178, ASTM B499)
Display60 × 30 mm LCD, dual-line alphanumeric (16 characters per line)
Probe InterfacePlug-in connector supporting up to 30 probe types (E- and VxE-series, e.g., EGAB1.3)
Auto-Probe RecognitionYes
Data StorageNone
ConnectivityNone
Power SupplyReplaceable or rechargeable batteries
ComplianceDIN EN ISO 2178, ASTM B499
Included AccessoriesProtective cap, carrying case, batteries, operating manual
ExcludedProbes, calibration standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelXDVM-W
Measurement PrincipleX-ray fluorescence (XRF)
Standards ComplianceDIN 50987, ISO 3497, ASTM B568
Cabinet Dimensions (H×W×D)720 × 660 × 950 mm
Weight~135 kg
Internal Chamber (H×W×D)160 × 560 × 530 mm
X-ray TubeAdjustable high voltage (30/40/50 kV), current up to 0.8 mA
DetectorXenon-filled proportional counter with 4096-channel ADC (displayed as 256-channel spectrum)
Collimator OptionsStandard Set I (0.1 mm, 0.2 mm, 0.05×0.05 mm², 0.03×0.2 mm² slot), optional Sets II & III
XY Stage Travel250 × 250 mm (XDVM-W standard configuration)
Z-axis Travel145 mm
CameraHigh-resolution color CCD with dual magnification (×40 / ×80), crosshair + metric grid + spot size indicator
Software PlatformNative Win32 application for Windows 2000 and later
Language SupportEnglish, German, French, Italian, Spanish, Chinese, Japanese
Data InterfaceRS-232 serial port, remote command control via script files or network environment
CalibrationAutomated beam centering, “Application Toolbox” with calibration standards and parameter disk
ReportingUser-defined report editor with embedded images (BMP), company logos, charts, font selection
Statistical ToolsSPC charts, probability plots, histogram analysis
SecurityCustomizable “short menu” lockout for critical system functions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelFERITSCOPE FMP30
Measurement PrincipleMagnetic Induction (Ferrite-Specific Permeability Detection)
DisplayBacklit LCD, 128 × 64 pixels
Probe InterfaceInterchangeable modular probe connector
CalibrationSingle-point calibration across full measurement range
Units% Fe (ferrite number equivalent) and vol.% Fe
ComplianceDesigned per ISO 8249:2017, ASTM A802, EN 17068
Operating Temperature0 °C to 50 °C
IP RatingIP65 (dust- and water-resistant)
Power SupplyRechargeable Li-ion battery (≥10 h continuous operation)
Data OutputUSB 2.0, optional Bluetooth 4.2 module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelHM2000
Instrument TypeNanoindentation Tester
Max Indentation Depth500 µm
Effective Load Range0.1–2000 mN
Load Resolution150 nN
Displacement Range130 mm
Displacement Resolution0.01 nm
Max Friction Force50 N
Indenter TypesVickers, Berkovich, Tungsten Carbide Sphere
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelHM500 LIGHT
ComplianceDIN EN ISO 14577-1, DIN EN ISO 14577-2, DIN 50359
Measurement PrincipleContinuous Stiffness Measurement (CSM) & Depth-Sensing Indentation
Load Range0.1 mN – 500 mN
Depth Resolution≤ 0.05 nm (50 pm)
Load Resolution≤ 0.01 mN
Indenter TypesVickers (136° diamond pyramid), Berkovich (115.2° tri-pyramid), spherical WC or diamond
Stiffness Measurement ModeEnhanced Stiffness Profiling (ESP)
Data Acquisition RateUp to 1 kHz
Zero-Point DetectionCapacitive contact sensing with sub-nm repeatability
Environmental StabilityActive thermal drift compensation (< 0.05 nm/s)
Software PlatformFISCHER FISCHERWIN v8.x (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelXAN-DPP
ConfigurationBenchtop/Free-standing
Excitation SourceRhodium anode X-ray tube
DetectorPeltier-cooled Si-PIN diode (≈ −30 °C)
Energy Resolution180 eV (Mn Kα)
Elemental RangeAl (Z=13) to U (Z=92)
CollimatorsMotorized, programmable: Ø0.2 mm, Ø0.6 mm, Ø1.0 mm, Ø2.0 mm
Measurement Chamber Internal Dimensions (incl. sloped door)W 318 mm × D 307 mm × H 29–86 mm
Usable Height Zone (full-height region)W 318 mm × D 203 mm × H 86 mm
Distance CompensationPatented DCM (Distance Controlled Measurement) algorithm
CalibrationStandardless quantitative analysis enabled via fundamental parameters method
Simultaneous OutputElemental concentration (ppm–wt%) and substrate thickness (µm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelXDVM-u
Measurement PrincipleX-ray Fluorescence (XRF)
ComplianceDIN 50987, ISO 3497, ASTM B568
Max. Measurable Layers23
Elements AnalyzedCl (Z=17) to U (Z=92)
Element Quantification Rangex ppm to 100%
Spectral Channels1024 (raw: 4096)
Minimum Spot Size50 × 100 µm
Focal Depth Range2.5 mm
X-ray TubeAdjustable HV (30/40/50 kV), Current up to 0.8 mA
DetectorPeltier-cooled semiconductor with high energy resolution
XY Stage TravelX=250 mm, Y=220 mm, Positioning Accuracy: ±0.005 mm
Z-Axis Travel95 mm
Camera Magnification30×–1108× with crosshair & scale grid
SoftwareWinFTM® V6 with PDM (Product Data Management)
InterfaceRS232, Ethernet, removable storage
LanguagesEnglish, German, French, Italian, Spanish, Chinese
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelSIGMASCOPE® GOLD
Measurement PrincipleEddy Current Conductivity Testing per ASTM E 1004
ApplicationNon-Destructive Authentication of Gold, Silver, and Other Noble Metal Coins & Bullion
Penetration Depth Adjustable (Mup to ~8 mm
Bup to ~17 mm)
ComplianceASTM E 1004, ISO 2360, EN 10045-1
Sample HandlingSurface measurement through non-conductive coatings (e.g., plastic encapsulation films)
DisplayHigh-resolution color touchscreen with real-time phase-angle analysis
Data OutputCSV export, GLP-compliant audit trail (optional), USB & Bluetooth connectivity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelXUL Series
Measurement PrincipleEnergy-Dispersive X-Ray Fluorescence (ED-XRF)
Standards ComplianceDIN 50987, ISO 3497, ASTM B568
X-ray Tube VoltageAdjustable to 30 kV / 40 kV / 50 kV
Collimator OptionsØ0.3 mm circular or 0.05 × 0.3 mm rectangular (optional)
Sample Chamber Dimensions (W×D×H)455 × 580 × 510 mm
Internal Chamber Dimensions (W×D×H)360 × 380 × 240 mm
Manual X-Y Stage Travel50 mm (X) × 50 mm (Y)
Imaging SystemIntegrated color CCD camera with real-time magnified view and auto-focus
Beam IndicatorOn-screen X-ray beam size overlay synchronized with focal distance
Software PlatformWinFTM® v6 (base) or Super WinFTM® (optional, order no. 602-950)
Language SupportEnglish, German, French, Italian, Spanish, Chinese
ReportingGraphical reports with embedded sample images, SPC charts, probability plots, histogram analysis
Regulatory ReadinessSupports GLP/GMP documentation workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelPMP10
Measurement PrinciplePhase-Sensitive Eddy Current
Operating Frequencies60 kHz / 240 kHz / 1.25 MHz
Probe CompatibilityESD20Cu, ESD20Ni, ESD20Zn, ESD2.4, ESL080
Max Data Storage20,000 measurements across 4,000 data groups
Applications100 user-defined programs
Display Resolution3-level precision
Measurement ModesAutomatic, Continuous, External Trigger
Analysis ModesScientific, Statistical, Limit (Hi/Lo), Analog Simulation
SecurityPassword protection & key lock
Power ManagementAuto-off
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFischer
OriginGermany
ModelFMP10–FMP40
Measurement PrinciplesMagnetic Induction (for ferrous substrates) & Eddy Current (for non-ferrous conductive substrates)
Compliance ModesIMO PSPC, SSPC-PA2, QUALANOD, QUALICOAT
Memory CapacityThousands of measurement records
Probe InterfaceInterchangeable probe system
Operating PrincipleDual-method substrate-agnostic thickness quantification via calibrated electromagnetic field perturbation analysis
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0