Gas Chromatograph
Filter
Showing 421–450 of 614 results
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC70 |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmed Temperature Steps | Up to 99 |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 psi |
| Inlet Temperature Max | 450 °C |
| Inlet Pressure Setpoint Range | 0–1000 psi |
| Inlet Total Flow Setpoint Range | 0–1000 mL/min |
| EPC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Inlet Configurations | Up to 3 simultaneously installed, 6 optional inlet types |
| Detector Capacity | 1–4 modular detectors (FID, TCD, ECD, FPD, NPD) |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| TCD Sensitivity | ≥10,000 mV·mL/mg (n-hexadecane) |
| ECD Detection Limit | ≤1×10⁻¹⁴ g/mL (63Ni source) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC80 |
| Temperature Control Range | 20–450 °C |
| Maximum Ramp Rate | 0–60 °C/min |
| Cooling Rate | 1 °C/min (from 300 °C to 100 °C in ≤3.5 min at 25 °C ambient) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 psi |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1000 psi |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| EPC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Programmed Temperature Vaporizing (PTV) Support | Yes |
| Max Temperature Ramping Steps | 99 |
| Max Hold Time per Step | 6000 min |
| Temperature Stability | ±0.01 °C |
| Temperature Uniformity | ±1% (100–350 °C) |
| Brand | Lunan Ruihong |
|---|---|
| Model | GC-55 |
| Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 4 °C to 450 °C |
| Ramp Rate | 0.1–120 °C/min |
| Cool-down Time | ≤4 min (450 °C → 50 °C) |
| Carrier Gas Flow Range | 0–1000 mL/min |
| Carrier Gas Pressure Range | 0–100 psi |
| Injector Max Temp | 450 °C |
| Injector Pressure Setpoint Range | 0–100 psi |
| Injector Total Flow Setpoint Range | 0–500 mL/min |
| Temperature Zones | 8 independent zones |
| Programmed Temperature Steps | up to 100 steps |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| EPC/EFC Resolution | 0.001 psi / 0.001 mL/min |
| Maximum Split Ratio | 1:1000 |
| Detector Support | FID, TCD, ECD, FPD, NPD (up to 4 simultaneously) |
| Data Interface | Ethernet IEEE 802.3 (MODBUS/TCP compliant) |
| Display | 10.1″ capacitive color touchscreen |
| Brand | Lunan Ruihong |
|---|---|
| Model | GC-8850 |
| Origin | Shandong, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 4 °C to 450 °C |
| Ramp Rate | 0.1–60 °C/min |
| Cooling Rate | 300 °C to 50 °C in ~8 min |
| Carrier Gas Flow Range | 0–1000 mL/min |
| Carrier Gas Pressure Range | 0–400 kPa |
| Programmable Pressure/Flow Steps | 16 |
| Injector Max Temp | 420 °C |
| Injector Pressure Setpoint Range | 0–400 kPa |
| Injector Total Flow Setpoint Range | 0–1000 mL/min |
| Temperature Zones | 8 independent zones |
| Temperature Resolution | 0.5 °C |
| Temperature Accuracy | ±0.1 °C |
| Detector Options | FID, TCD, ECD, FPD, NPD (up to 3 simultaneously) |
| Data Interface | 10/100/1000BASE-T Ethernet (IEEE 802.3), MODBUS/TCP compliant |
| Display | 7-inch color capacitive touchscreen (hot-swappable, handheld-capable) |
| Analog-to-Digital | 24-bit low-noise ADC with baseline storage and subtraction |
| External Events | 8 inputs, 2 auxiliary outputs |
| Injection Modes | Packed column, capillary column, 6-port gas valve, optional autosampler |
| Brand | LuNan RuiHong |
|---|---|
| Model | QT-3000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petroleum & Petrochemical Industry |
| Column Oven Temperature Range | +5°C above ambient to 250°C |
| Temperature Control Accuracy | ±0.1°C (column oven), ±1°C (inlet/detector) |
| Max Heating Rate | 20°C/min |
| Cooling Time | ≤8 min (180°C → 35°C) |
| FID Detection Limit | ≤1×10⁻¹¹ g/s (benzene) |
| FID Drift | ≤0.5 mV/h |
| Maximum Temperature Program Steps | 4 |
| Injector | Water-Driven 6-Port Sampling Valve + Manual Syringe Port |
| Software | Dedicated Light Hydrocarbon Qualitative/Quantitative Data Processing Suite |
| Compliance | Designed for ASTM D1945, ASTM D1946, ISO 6974-1, and GB/T 13610-compliant light hydrocarbon analysis workflows |
| Brand | Lunan Ruihong |
|---|---|
| Origin | Shandong, China |
| Model | SP-6801A |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +3°C to 399°C |
| Temperature Stability | ±0.1°C |
| Temperature Accuracy | ±3% of setpoint |
| Oven Cooling Rate | ~8 minutes from 250°C to 50°C |
| FID Detection Limit | ≤5×10⁻¹¹ g/s (n-hexadecane in iso-octane) |
| FID Linear Range | ≥10⁶ |
| TCD Sensitivity | ≥2000 mV·mL/mg (benzene/toluene) |
| TCD Linear Range | ≥10⁴ |
| ECD Detection Limit | ≤5×10⁻¹³ g/mL (γ-HCH in iso-octane) |
| Brand | Lunan Ruihong |
|---|---|
| Origin | Shandong, China |
| Model | SP-7890Plus |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | 4°C above ambient to 450°C |
| Heating Rate | 0.1–80°C/min |
| Cooling Rate | ≤2 min from 200°C to 100°C |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi |
| Injector Maximum Operating Temperature | 450°C |
| Total Injector Flow Setting Range | 0–1000 mL/min |
| Brand | GAOMAI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MIDAC Dynamic Calibration System |
| Price Range | USD 42,000 – 70,000 (FOB) |
| Instrument Type | Laboratory Gas Chromatography Calibration Standard Generator |
| Application Scope | Universal Calibration for GC & FTIR |
| Gas Dilution Stages | Triple-stage |
| Mass Flow Controllers (MFCs) | Multi-channel digital MFC support |
| Corrosive Gas Compatibility | Yes (acidic, alkaline, organic) |
| Dilution Ratio Programmability | Yes, time-scheduled auto-run |
| Real-time Flow Monitoring | Yes |
| Repeatability | ≤ ±0.8% RSD (N₂ baseline, 10–1000 sccm) |
| Control Interface | PLC-based with 7″ TFT touchscreen (800×600) |
| PLC Cycle Time | Standard mode 160 µs |
| Onboard Memory | Display buffer 26 MB |
| Touchscreen Lifetime | ≥ 5 years (MTBF) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC-8810 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Coal Industry Specific |
| Detection Limits | Permanent Gases (N₂, CO₂, O₂) < 10 ppm |
| Analysis Time | ≤ 2 min (including backflush) |
| Modular Configuration | Up to 4 independent GC channels |
| Detector Technology | NEMS-based silicon micro-TCD |
| Flow Control | Electronic Pressure Control (EPC) per channel |
| Temperature Control | Independent oven and column-zone heating per module |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor & System Integrator |
| Regional Classification | Domestic (China-Made) |
| Model | GC7890B |
| Pricing | Upon Request |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC8800 (Dual-Detector) |
| Instrument Type | Laboratory Gas Chromatograph |
| Primary Application | High-Purity Gas Analysis |
| Detector Configuration | Pulsed Discharge Helium Ionization Detector (PDHID) + Secondary Detector (e.g., TCD or FID) |
| Carrier Gas | Ultra-High-Purity Helium Only |
| Linear Range | 10⁵ |
| Detection Limit | Sub-ppb for H₂, O₂, N₂, CO, CO₂, CH₄, C₂H₆, C₂H₄, C₂H₂, H₂S, C₃H₈, C₃H₆ |
| Regulatory Compliance | Designed to support GLP/GMP workflows |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC8800 Series |
| Instrument Type | Online Gas Chromatograph |
| Detector Configurability | Up to three simultaneous detectors (TCD, uTCD, FID, FPD, ECD, NPD, PDHID) |
| Injection Options | Packed column, split/splitless capillary, valve injection, 6-/12-position liquid auto-sampler, headspace autosampler, pyrolysis injector |
| Oven Temperature Range | +4 °C above ambient to 450 °C (1 °C increment) |
| Oven Temperature Stability | ±0.1 °C at 200 °C |
| Oven Programmable Stages | 16 temperature ramps |
| Cooling Rate | 260 °C to 50 °C in ~6 min |
| Temperature Zones | 8 independently controlled zones |
| Carrier Gas Control | Electronic Pressure Control (EPC), pressure resolution 0.01 kPa, flow resolution 0.01 sccm |
| Display | 5.7-inch color TFT touchscreen |
| Data Interface | Ethernet (IEEE 802.3), PC-controlled operation or standalone mode |
| Remote Capability | Network-enabled remote monitoring, unattended operation, distributed acquisition, centralized control |
| Multidimensional GC Support | Center-cutting and valve-switching configurations enabled |
| Software | Method-driven acquisition with full parameter storage and recall |
| Compliance | Designed for GLP/GMP environments |
| Brand | MNK |
|---|---|
| Model | GC8800-II |
| Origin | Beijing, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Focus | High-Purity Gas Analysis |
| Control Interface | IEEE 802.3 Ethernet |
| EPC Module | Integrated Electronic Pressure Control (EPC) and Electronic Flow Control (EFC) |
| Autosampler Compatibility | Dual-tower 24-position liquid autosampler |
| Optional Gas Autosampling | MNK Cylinder & Gas-Phase Autosampler |
| Ancillary Module Support | MNK Flash Vaporizer for LPG, Butadiene, and 1-Butene analysis |
| Data System | Multi-instrument data aggregation |
| Regulatory Alignment | Designed to support GLP-compliant workflows and 21 CFR Part 11–ready audit trail configuration (when paired with validated software) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC8810 |
| Instrument Type | Online Gas Chromatograph |
| Application Focus | High-Purity Gas Analysis |
| Detector Configuration | Up to 3 Simultaneous Detectors (PDHID, TCD, FID, FPD) |
| Communication Interface | Ethernet-enabled Industrial Bus Architecture |
| Compliance Context | Designed for GLP/GMP-aligned environments with audit-ready data handling capabilities |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | M8880 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | High-Purity Gas Analysis |
| Carrier Gas Options | Single selectable gas (e.g., He, H₂, or Ar) |
| Detector Configuration | Dual-detector, multi-column parallel architecture |
| Temperature Control | 8 independent zones, 20-step programmable ramping |
| Advanced Functionality | Built-in back-flush module enabling heart-cutting and column switching |
| Data System | Dedicated GC workstation with automated flammability triangle (CH₄–O₂–N₂) explosion hazard assessment |
| Detection Limits (v/v) | PDHID — H₂ (0.06 µL/L), CH₄ (0.08 µL/L), CO (0.08 µL/L), C₂H₆ (0.01 µL/L), CO₂ (0.09 µL/L), C₂H₄ (0.01 µL/L), C₂H₂ (0.01 µL/L), C₃H₈ (0.01 µL/L), H₂S (0.01 µL/L), C₃H₆ (0.01 µL/L), SO₂ (0.23 µL/L) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | M8880 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Gas Analysis |
| Carrier Gas Options | Single selectable gas (e.g., He, H₂, or Ar) |
| Dual-Detector Configuration | PDHID + TCD |
| Independent Temperature Zones | 8 |
| Oven Programmed Ramps | 20-step |
| Back-Flush & Heart-Cut Capability | Integrated |
| Detection Limits (v/v) | PDHID — H₂: 0.06 µL/L, CH₄: 0.08 µL/L, CO: 0.08 µL/L, C₂H₆: 0.01 µL/L, CO₂: 0.09 µL/L, C₂H₄: 0.01 µL/L, C₂H₂: 0.01 µL/L, C₃H₈: 0.01 µL/L, H₂S: 0.01 µL/L, C₃H₆: 0.01 µL/L, SO₂: 0.23 µL/L |
| TCD — O₂ | 49 µL/L, N₂: 70 µL/L |
| PDHID Specifications | Pulsed Discharge Helium Ionization Detector |
| TCD Specifications | Baseline Noise ≤ 20 µV |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | PGC-8800 |
| Instrument Type | Online Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Detectors | PDHID, TCD, FID |
| Detection Limits (ppb) | H₂ (5), He (5), O₂ (10), N₂ (10), Ar (10), Ne (10), CO (25), CO₂ (5), CH₄ (5), CF₄ (10), C₂F₆ (20), SO₂ (20), F₂ (20), C₃F₈ (20) |
| Temperature Control Accuracy | ±0.01°C |
| Baseline Noise | ≤0.1 mV |
| Analog Outputs | 5–12 channels of 4–20 mA |
| Communication Interfaces | 1× Ethernet, 1× RS-232 (expandable) |
| Display | 10.1″ high-resolution capacitive touchscreen |
| Enclosure | Standard 5U rack-mount chassis (482 × 432 × 222 mm) |
| Brand | MNK |
|---|---|
| Model | PGC-8800 |
| Type | Online Gas Chromatograph |
| Primary Application | High-Purity Gas Analysis |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Detection Limits (PDHID) | H₂ (5 ppb), He (5 ppb), O₂ (10 ppb), N₂ (10 ppb), Ar (10 ppb), Ne (500 ppb), CO (25 ppb), CO₂ (5 ppb), CH₄ (5 ppb), CF₄ (10 ppb), C₂F₆ (20 ppb), SO₂F₂ (20 ppb), C₃F₈ (20 ppb) |
| Complementary Detectors | TCD, FID |
| Sample Phase | Gaseous |
| Operating Mode | Continuous Unattended Online Monitoring |
| Origin | Beijing, China |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NBGC-60 |
| Instrument Type | Online Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Brand | North Branch Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | GC-8000 |
| Pricing | Available Upon Request |
| Brand | North分Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | AHS-610 Headspace Autosampler + Thermo TRACE 1300 GC |
| Temperature Control Range | 400 °C |
| Heating Rate | 40 °C/min |
| Cooling Rate | from 450 °C to 50 °C in ~5 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–16 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Model | OG-2000V |
| Instrument Type | Laboratory Gas Chromatograph for Geochemical Pyrolysis |
| Application Domain | Petroleum & Petrochemical Industry |
| Temperature Control Range | 360 ± 0.5 °C (FID), 600 ± 0.5 °C (Pyrolysis Furnace & Oxidation Furnace) |
| Ramp Rate | < 0.5 °C/min |
| Maximum Injector Temperature | 800 °C |
| Detection Principle | Flame Ionization Detection (FID) |
| Minimum Hydrocarbon Detection | 0.001 mg HC/g rock |
| Baseline Drift | < 0.1 mV/30 min |
| Linear Dynamic Range | 10⁶ |
| Analysis Cycle Time (Full Pyrolysis–Residual Carbon) | 14.5 min |
| Number of Predefined Thermal Programs | 4 (Source Rock, Reservoir Rock, Thermal Simulation, User-Defined) |
| Temperature Linearity Deviation | < 0.5 °C/min |
| Interface | USB 2.0 (Direct Signal Output to PC) |
| Brand | Ontech |
|---|---|
| Model | Ontech610 |
| Type | Online Gas Chromatograph |
| Application | Environmental Emission Monitoring |
| Compliance | HJ 38-2017, HJ 212-2017 |
| Sampling Method | Quantitative Loop Injection |
| Valve Configuration | 12-Position Multiport Valve |
| Column Technology | Dual-Column System with Heart-Cut and Back-Flush |
| Pressure Control | Electronic Pressure Control (EPC) |
| Detection | FID (Flame Ionization Detector) |
| Target Analytes | Total Hydrocarbons (THC), Methane (CH₄), Non-Methane Hydrocarbons (NMHC), BTEX (Benzene, Toluene, Ethylbenzene, Xylenes) |
| Enclosure Rating | IP54 |
| Operating Temperature Range | 5–40 °C |
| Power Supply | 220 V AC, 50 Hz |
| Data Output | RS485, Ethernet, 4–20 mA Analog Outputs |
| Communication Protocol | HJ 212-2017 Compliant Data Transmission |
| Brand | Ontech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Ontech710 |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Online Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | GC8800 |
| Instrument Type | Online Gas Chromatograph |
| Application Domain | Ultra-High-Purity (UHP) Gas Impurity Analysis |
| Detector Type | Pulsed Discharge Helium Ionization Detector (PDHID) |
| Carrier Gas | Ultra-High-Purity Helium (≥99.999%, purified to ≤10 ppb total impurities) |
| Baseline Noise | ≤0.1 mV |
| Baseline Drift | ≤0.5 mV/30 min |
| Detection Limit | ≤1.0 × 10⁻¹⁰ g/mL |
| Gas Control Options | Manual Valving & Electronic Pressure Control (EPC) |
| Data Transmission | Ethernet-enabled Remote Monitoring & Unattended Operation |
| Regulatory Compliance Support | ASTM D7622, ISO 8573-8, SEMI F57, IEC 60400, USP <621>, FDA 21 CFR Part 11-ready audit trail capability |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 500 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Time | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Clarus 580 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | Not Specified |
| Oven Ramp Rate | Not Specified |
| Cooling Rate | Not Specified |
| Carrier Gas Flow Range & Control | Not Specified |
| Carrier Gas Pressure Range & Control | Not Specified |
| Injector Maximum Operating Temperature | Not Specified |
| Injector Pressure Setting Range | Not Specified |
| Injector Total Flow Setting Range | Not Specified |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 580 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Temperature Control Range | Ambient to 450 °C (oven) |
| Ramp Rate | Up to 120 °C/min |
| Cooling Rate | Down to ambient in <3.5 min (with optional cryo-cooling) |
| Carrier Gas Flow Range | 0–100 mL/min (He, H₂, N₂), electronic pressure/flow control (EPC) |
| Inlet Pressure Range | 0–100 psi |
| Total Inlet Flow Range | 0–120 mL/min |
| Inlet Operating Temperature | Up to 450 °C |
| Compliance | ASTM D3606, D1319, D5186 |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Clarus 590 / Clarus 690 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal (Food, Pharmaceuticals, Petrochemicals, Environmental Analysis) |
| Software Platform | TotalChrom™ Chromatography Data System (CDS) |
| Regulatory Compliance Support | 21 CFR Part 11, GLP/GMP Audit Trail Capabilities |
| Automation Platform | TurboMatrix™ MultiPrep Autosampler (Liquid, Headspace, SPME) |
| Flow Control Technology | Swafer™ Micro-Channel Pneumatic Control |
| Detector Options | FID, TCD, ECD, NPD, FPD, PID |
| Inlet Types | Split/Splitless, PTV, Cold On-Column, Packed Column |
| Column Oven | Patented concentric exhaust design (Clarus 690) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 600 |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient to 450 °C |
| Maximum Ramp Rate | 140 °C/min (programmable up to 160 °C/min) |
| Cooling Rate | 450 °C to 50 °C in <2 min |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Max Temp | 450 °C (PSS injector up to 500 °C) |
| Injector Pressure Range | 0–970 kPa |
| Injector Total Flow Range | 0–1200 mL/min |
| FID Detection Limit | <3×10⁻¹² g C/sec (n-nonane, S/N = 2:1) |
| Oven Operating Range (with cryogenic cooling) | –90 °C to 450 °C |
| Temperature Programming | 9 ramps / 10 steps |
| Injector Types Supported | Packed Column (PKD), Split/Splitless Capillary (CAP), Programmable Temperature Vaporization (PSS) |