Gas Chromatograph
Filter
Showing 391–420 of 614 results
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC9800 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry–Specific |
| Oven Temperature Range | Ambient + 8 °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | 400 °C → 50 °C in ≤4 min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–250 kPa |
| Injector Maximum Operating Temperature | 300 °C |
| Injector Pressure Setting Range | 0–250 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region Category | Domestic (China) |
| Model | GC9800 |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Quantitative Analysis |
| Oven Temperature Range | +5 °C above ambient to 400 °C |
| Maximum Ramp Rate | 0–40 °C/min |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC9800 (Network-Enabled) |
| Temperature Control Range | Ambient +3°C to 450°C |
| Maximum Ramp Rate | 0–40°C/min (adjustable in 0.1°C/min increments) |
| Cooling Rate | ≤5 min (350°C → 50°C with motorized back-opening door) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Temperature Range | 0–450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Total Injector Flow Setting Range | 5000–10,000 mV·mL/mg (benzene reference) |
| Detection Limits | TCD ≥6000 mV·mL/mg, FID ≤3.0×10⁻¹² g/s (n-hexadecane), ECD ≤10 fg/mL (lindane), FPD ≤1.0 pg/s (P), ≤10 pg/s (S) |
| Linearity | TCD 10⁵, FID 10⁷, ECD 10⁴, FPD 10⁴ |
| Retention Time RSD | <0.008%, Peak Area RSD: <1.0% |
| EPC/EFC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Column Oven Capacity | 305 × 160 × 278 mm (W×D×H) |
| Dimensions (W×D×H) | 530 × 570 × 506 mm |
| Weight | ≤50 kg |
| Power Consumption | ≤3000 W |
| Input Power | 220 V ±10%, 50 Hz ±5% |
| Operating Environment | 5–35°C, RH ≤85% |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Air Monitoring |
| Oven Temperature Range | Ambient +5°C to 400°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Oven Cooling Rate | 300°C → 50°C in ≤4 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–250 kPa |
| Injector Maximum Temperature | 400°C |
| Injector Pressure Setting Range | 0–250 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detection Method | Flame Ionization Detection (FID) |
| Sample Introduction | Dual-loop 10-port valve with parallel-packed column configuration |
| Detection Limit (1 mL air sample) | 0.04 mg/m³ for both CH₄ and NMHC |
| Compliance Standards | HJ 604-2011, HJ/T 38-1999 |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC9800N |
| Temperature Control Range | Ambient + 3 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min (adjustable in 0.1 °C increments) |
| Maximum Ramp Rate | >120 °C/min |
| Cooling Time | ≤5 min (350 °C → 50 °C, with motorized backdoor) |
| Carrier Gas Flow Range | 0–100 mL/min |
| Carrier Gas Pressure Range | 0–250 kPa |
| Injector Max Temp | 300 °C |
| Injector Pressure Setpoint Range | 0–250 kPa |
| Total Injector Flow Setpoint Range | 0–1200 mL/min |
| EPC/EFC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Retention Time RSD | <0.008% |
| Peak Area RSD | <1.0% |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC9800N/F |
| Temperature Control Range | Ambient + 3°C to 450°C |
| Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 350°C to 50°C in ≤5 min (with auto back-flush door) |
| Carrier Gas Flow Control Range | 0–100 mL/min |
| Carrier Gas Pressure Control Range | 0–250 kPa |
| Injector Max Temp | 300°C |
| Injector Pressure Set Range | 0–250 kPa |
| Total Injector Flow Set Range | 0–1200 mL/min |
| Detection Modes | TCD, FID, ECD, FPD (configurable) |
| Column Oven Programmable Stages | Up to 16 (expandable to unlimited) |
| EPC/EFC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Retention Time RSD | <0.008% |
| Peak Area RSD | <1.0% |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Dimensions (W×D×H) | 530 × 570 × 506 mm |
| Weight | ≤50 kg |
| [Brand | Kingpu |
|---|---|
| Origin | Shandong, China |
| Model | GC-8890 Dedicated for DME in LPG |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | Ambient + 8°C to 420°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Oven Cool-down | 450°C to 50°C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Range & Control | 0–970 kPa (7 programmable segments) |
| Injector Max Temp | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min] |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SP-7800 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical GC |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Time | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | Ambient + 4 °C to 450 °C |
| Injector Pressure Setting Range | 0–100 psi (optional 0–150 psi) |
| Injector Total Flow Setting Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | SP6890 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Rate | 450 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Control Channels | 4 independent zones |
| Temperature Stability | ±0.1 °C |
| FID Detection Limit | ≤5.0×10⁻¹¹ g/s (benzene/CS₂) |
| TCD Sensitivity | ≥2500 mV·mL/mg (benzene) |
| Dimensions | 470 × 430 × 455 mm |
| Weight | ~45 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SP6900 |
| Application Field | Petrochemical Industry |
| Temperature Control | 5 independent zones, 5-step programmable ramping |
| Column Oven Range | Ambient +15°C to 399°C |
| Temperature Stability | Better than ±0.1°C |
| Heating Rate | 0.1–40°C/min |
| Time Programming | 0–255 min per step |
| TCD Sensitivity | ≥3500 mV·mL/mg (benzene) |
| Baseline Noise | ≤0.02 mV |
| Drift | <0.1 mV/h |
| Weight | ~60 kg |
| Sample Introduction | 6-port gas sampling valve |
| Data Output | Real-time purity and component quantification via PC interface |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | SP7800 |
| Pricing | Available Upon Request |
| Brand | LABA |
|---|---|
| Origin | USA |
| Model | G5 GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal |
| Temperature Control Range | Ambient to 850 °C |
| Oven Ramp Rate | 0.01–500 °C/min |
| Oven Cool-down Rate | ~1 min (850 °C → 0 °C) |
| Carrier Gas Flow Range & Control | 0–25,000 mL/min |
| Carrier Gas Pressure Range & Control | 0.001–100,000 psi |
| Injector Maximum Operating Temperature | 850 °C |
| Injector Pressure Setting Range | 0.001–100,000 psi |
| Injector Total Flow Setting Range | 0.0001–10,000 mL/min |
| Detector Sensitivity (ECD) | ≤10⁻¹⁵ g/s (for γ-HCH) |
| Brand | Labthink |
|---|---|
| Model | EO Residual Detection System |
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose EO residue quantification in sterilized medical devices |
| Oven Temperature Range | Ambient +3 °C to 399 °C |
| Oven Ramp Rate | 1–30 °C/min |
| Oven Cool-down Rate | ≤4 °C/min |
| Carrier Gas Flow Control Range | 0.1–5.0 mL/min (N₂ or He) |
| Carrier Gas Pressure Control Range | 0–200 psi |
| Injector Maximum Operating Temperature | 350 °C |
| Injector Pressure Setting Range | 0–200 psi |
| Injector Total Flow Setting Range | 1–50 mL/min |
| Brand | Labthink |
|---|---|
| Model | GC-6890 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +3°C to 399°C |
| Oven Ramp Rate | 1–30°C/min |
| Cooling Rate | ≤15 min from 300°C to 50°C |
| Compliance | Designed for GB/T 14233.1–2008 and GB/T 16886.7–2001 EO residue testing protocols |
| Brand | Labthink |
|---|---|
| Model | GC-6890 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +3 °C to 399 °C |
| Heating Rate | 1–30 °C/min |
| Cooling Rate | ≤15 min (from 300 °C to 50 °C) |
| Detector | Flame Ionization Detector (FID) |
| Column Oven Temperature Stability | ±0.1 °C |
| FID Detection Limit | ≤5×10⁻¹¹ g/s (benzene) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 490 × 490 × 480 mm (L×W×H) |
| Weight | 45 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-6890 |
| Temperature Control Range | Ambient + 3°C to 399°C |
| Heating Rate | 0.1–30°C/min |
| Cooling Rate | ≤15 min (from 300°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–10 mL/min |
| Carrier Gas Pressure Range & Control | 0–10 kPa |
| Injector Maximum Operating Temperature | 200°C |
| Injector Pressure Setting Range | 0–10 kPa |
| Injector Total Flow Setting Range | 0–10 mL/min |
| Brand | Labthink |
|---|---|
| Model | GC-6890 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +10°C to 399°C |
| Column Oven Temperature Precision | Better than ±0.1°C |
| FID Detection Limit | ≤5×10⁻¹¹ g/s (benzene) |
| Noise | ≤1% of full-scale recorder |
| Drift | ≤3% of full-scale recorder per hour |
| Power Consumption | Max 2 kW |
| Dimensions (L×W×H) | 470×430×455 mm |
| Weight | 30 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Model | GC-7800 |
| Price Range | USD 7,000–14,000 (FOB) |
| Temperature Control Range | Ambient +15 °C to 200 °C |
| Heating Rate | 1–30 °C/min |
| Maximum Column Oven Temperature | 399 °C |
| Temperature Stability | ±0.1 °C |
| Programmed Temperature Ramping | 5-step linear |
| Detector Options | FID (detection limit ≤1×10⁻¹¹ g/s for benzene), TCD (sensitivity ≥3000 mV·mL/mg for benzene in H₂ carrier) |
| Column Compatibility | Packed & capillary columns (including dedicated water-content analysis column and solvent residue separation column) |
| Data System | Integrated Windows-based chromatography workstation with ASTM/ISO-compliant reporting, GLP audit trail, and 21 CFR Part 11-ready user access control |
| Brand | Labthink |
|---|---|
| Model | GC-7800 |
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Class | Benchtop Laboratory Gas Chromatograph |
| Detector Standard | Hydrogen Flame Ionization Detector (FID) |
| Temperature Control Precision | ±0.1 °C (RT+15 °C to 200 °C) |
| Column Oven Programmable Ramp | Up to 8 temperature steps |
| FID Detection Limit | ≤1×10⁻¹¹ g/s (benzene) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 635 × 490 × 470 mm (L×W×H) |
| Weight | 55 kg |
| Brand | Labthink |
|---|---|
| Model | GC-7800 |
| Origin | Shandong, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Oven Temperature Range | Ambient +3°C to 399°C |
| Temperature Ramp Rate | 1–30°C/min |
| Cooling Rate | ≤15 min from 300°C to 50°C |
| Oven Temperature Stability | ±0.1°C (typical) |
| Programmed Temperature Ramping | Up to 5 steps |
| FID Detection Limit | ≤1×10⁻¹¹ g/s (benzene) |
| TCD Sensitivity | ≥3000 mV·mL/mg (benzene with H₂ carrier) |
| Dimensions | 635 × 490 × 480 mm (L×W×H) |
| Weight | 55 kg |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Imported Instrument |
| Model | GCxGC |
| Application Scope | General-Purpose |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | LPG-Analyzer GC Series |
| Price | Available Upon Request |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | 0–450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 300 °C to 100 °C in ≤3.5 min (at 25 °C ambient) |
| Carrier Gas Flow Range | 0–1200 mL/min (7-program segments) |
| Carrier Gas Pressure Range | 0–970 kPa (7-program segments) |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmable Temperature Steps | Up to 99 |
| Oven Time Setting Range | 0–9999 min |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 psi |
| Injector Max Temp | 450 °C |
| Injector Pressure Set Range | 0–1000 psi |
| Injector Total Flow Set Range | 0–1200 mL/min |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Simultaneous Detectors | Up to 4 |
| Injector Ports | Up to 3 configurable ports |
| Available Injector Types | 6 modular configurations |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9870 TVOC |
| Temperature Control Range | 25–450 °C |
| Maximum Ramp Rate | 60 °C/min |
| Cooling Rate | 1 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–1000 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1000 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient + 6 °C to 399 °C |
| Temperature Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 300 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range | 0–600 mL/min |
| Carrier Gas Pressure Range | 0–0.4 MPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Total Injector Flow Setting Range | 0–600 mL/min |
| Column Oven Dimensions | 260 × 250 × 150 mm (L×H×D) |
| Weight | 50 kg |
| Power Consumption | 2500 W |
| Display | 5.7″ LCD (320 × 240), Bilingual (English/Chinese) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Power Industry – Transformer Oil Dissolved Gas Analysis (DGA) |
| Oven Temperature Range | Ambient +4°C to 450°C |
| Maximum Ramp Rate | 0.1–50°C/min |
| Cooling Time | ~3 min (200°C to 100°C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control Range | 0–970 kPa (7 programmable segments) |
| Injector Max Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Stability | ±0.02°C |
| Programmable Temperature Steps | Up to 32 oven ramps |
| EPC Precision | Pressure ±0.001 psi |
| Dimensions | 400 mm × 300 mm × 400 mm (L×W×H) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Coal Mining Industry |
| Temperature Control Range | Ambient +4°C to 450°C |
| Maximum Ramp Rate | 0–60°C/min |
| Cooling Rate | 200°C → 100°C in ~3 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Range & Control | 0–970 kPa (7 programmable segments) |
| Injector Max Operating Temperature | 450°C |
| Injector Pressure Setting Range | Up to 450°C |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven | Supports up to four packed columns |
| Detector Compatibility | FID, TCD, FPD, methanizer, optional MS interface |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9870T |
| Temperature Control Range | Ambient + 6°C to 399°C |
| Ramp Rate | 0.1–40°C/min |
| Cooling Time | ~6 min (300°C to 50°C) |
| Carrier Gas Flow Range | 0–600 mL/min |
| Carrier Gas Pressure Range | 0–0.4 MPa |
| Injector Maximum Temperature | 400°C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–600 mL/min |
| Column Oven Dimensions | 260 × 250 × 150 mm (L×H×D) |
| Weight | 50 kg |
| Power Consumption | 2500 W |
| Voltage | 220 V ±10% |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| TCD Sensitivity | ≥10,000 mV·mL/mg (n-hexadecane) |
| ECD Detection Limit | ≤1×10⁻¹⁴ g/mL (⁶³Ni source) |
| Max Operating Temperature (FID) | ≤450°C |
| Programmed Temperature Ramping | 8-step linear |
| Temperature Stability | ±0.1°C |
| Temperature Gradient Uniformity | ±1% (100–350°C) |
| Data Storage Capacity | 20 chromatographic methods |
| Display | 10-inch LCD with bilingual (Chinese/English) interface |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC60 |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Max Ramp Rate | 65 °C/min |
| Cool-down Time | ≤3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmed Temperature Steps | Up to 99 |
| Inlet Max Temp | 450 °C |
| Inlet Pressure Range | 0–1000 kPa |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 kPa |
| Detector Compatibility | FID, TCD, ECD, FPD, NPD (up to 4 detectors simultaneously) |