Gas Detector
Filter
Showing 2161–2190 of 2974 results
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Model | MultiRAE 2 (PGM-62X8) |
| Sensor Compatibility | EC, LEL, TC, PID, IR, Radiation |
| Detection Channels | Simultaneous 6-parameter monitoring |
| Resolution | Down to 10 ppb (PID) |
| Certifications | ATEX, UL, CSA, IECEx, CMC |
| Operating Interface | Dual-language (English/Chinese) LCD with auto-layout |
| Input Power | Rechargeable Li-ion battery |
| Enclosure Rating | IP65 |
| Wireless Capability | Built-in 900 MHz / 4G LTE optional |
| Fall Detection | Integrated accelerometer-based fall alarm |
| User Interface | Three oversized tactile buttons, glove-compatible |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PGM-2400 |
| Price | Upon Request |
| Gas Options | H₂S, CO |
| Operating Life | Up to 36 months (24 months typical runtime) |
| Environmental Rating | Extended temperature range operation |
| Maintenance | Maintenance-free for full service life |
| Display | Real-time gas concentration, battery status |
| Diagnostics | Built-in self-test (C-Test), calibration due alert, sleep mode |
| Data Interface | Infrared port for event log retrieval |
| Calibration | Dedicated C-Test gas test and calibration station |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Instrument Type | Portable VOC Detector |
| Detection Principle | Photoionization Detection (PID) |
| Detection Range | 1 ppb – 10,000 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ±3% of reading |
| Response Time (T90) | 2 s |
| Sampling Method | Integrated high-flow pump with optional 30 m sampling hose |
| Calibration | Auto-zero and temperature/pressure/humidity compensated |
| Connectivity | Integrated Bluetooth and optional wireless module |
| Display | Backlit graphical LCD with multilingual UI (including Chinese) |
| Gas Library | Preloaded database for >1,000 VOCs |
| Compliance | Designed to support OSHA, NIOSH, and ACGIH exposure limit referencing |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Model | RAEGuard2 PID |
| Sensor Type | Third-Generation Intrinsically Safe PID |
| Detection Principle | Photoionization Detection (PID) |
| Measurement Range | 0–10,000 ppm (isobutylene-equivalent), extendable via range scaling |
| Resolution | 1 ppb (typical for low-concentration VOCs) |
| Response Time (T90) | <10 s (with integrated sampling pump) |
| Operating Temperature | –30 °C to +55 °C |
| Enclosure Rating | IP66 / NEMA 4X |
| Certification | ATEX II 1G Ex d [ia] IIC T4 Ga, UL 913 Class I, Div 1, Groups B, C, D |
| Output Signals | 4–20 mA (3-wire), RS485 Modbus RTU, 3 configurable relay outputs (NO/NC) |
| Display | Backlit dot-matrix LCD with multilingual support (English/Chinese) |
| Housing Material | 316 stainless steel |
| Sampling Method | Integrated intrinsically safe diaphragm pump (pump-suction) |
| Calibration | Zero & span calibration supported offline or in-situ via magnetic wand |
| Compliance | Designed for compliance with OSHA PELs, ACGIH TLVs®, EPA Method TO-15 & TO-17, and ISO 16000-6 for indoor air VOC screening |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RDK (Rapid Deployment Kit) |
| Pricing | Available Upon Request |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Model | PGM-1600 |
| Instrument Principle | Electrochemical Sensor (O₂, CO, H₂S), Catalytic Bead (LEL), Metal Oxide Semiconductor (MOS) |
| Type | Portable Multicomponent Gas Analyzer |
| Response Time | ≤15 s (T90) |
| Repeatability | ±2% of reading (O₂, LEL, CO, H₂S) |
| Sampling Pump | Integrated diaphragm pump, 30 m extendable sampling line |
| Power Supply | Rechargeable 3.7 V Li-ion battery or 4× AA alkaline batteries |
| Data Storage | Removable SD card, CSV/Excel-compatible export format |
| Display | Backlit graphical LCD with multilingual UI (including Chinese) |
| Sensor Slots | 3 configurable bays supporting interchangeable electrochemical, catalytic bead, TC, and MOS sensors |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Model | SP-1003 Plus-16 |
| Certifications | Compliant with GB 16808–2008 |
| Power Backup | ≥2 h (main power failure) |
| Alarm Sound Pressure Levels | 65 dB / 95 dB / 115 dB (user-selectable) |
| Analog Output | 4–20 mA (synchronized) |
| Digital Communication | RS485 Modbus RTU & RS232 |
| Relay Outputs | 8 programmable + 3 common (Level 1 alarm, Level 2 alarm, fault) with adjustable delay (0–60 s) |
| Event Log Capacity | ≥1,000 entries |
| Display | Main – large dot-matrix LCD (Chinese menu, real-time gas concentration, zone ID, system time) |
| Self-Test & Lock Display Functions | Yes |
| Standby Power Low-Voltage Alert | >1 h warning duration |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Model | SP-1102 |
| Explosion Protection | Ex d IIB T4 Gb |
| Output Signals | 4–20 mA (3-wire), Relay Output (SPDT) |
| Sensor Type | Pd/Pt Catalytic Bead (Pellistor) |
| Enclosure Rating | IP66/IP67 |
| Electrical Interfaces | 3/4" NPTF, 3/4" NPTM, 1/2" NPTF/M, G3/4F/M |
| Sensor Housing Material | 316 Stainless Steel |
| Compliance | UL 913, CSA C22.2 No. 152, ATEX 2G, IECEx, EN 60079-0, -1, -11, -26 |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SP-1104 Plus |
| Pricing | Upon Request |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Model | SP-1204A |
| Detection Principle | Electrochemical Sensor |
| Measurement Range | 0–1000 ppm CO |
| Resolution | 1 ppm |
| Accuracy | ±3% FS |
| Response Time (T90) | <30 s |
| Output Signals | 4–20 mA, RS485 Modbus RTU, Active Switch Output (0–300 s adjustable delay) |
| Data Logging | Up to 900 alarm events with timestamp |
| Display | High-brightness LED, 4-digit |
| Operating Temperature | –20 °C to +50 °C |
| Enclosure Rating | IP65 |
| Compliance | UL 2075, CE, RoHS, ATEX Zone 2 (non-incendive), IEC 61000-4 EMC series |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SP-3104 Plus |
| Pricing | Available Upon Request |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SP-3200 |
| Pricing | Available Upon Request |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Model | PGM-1700 |
| Protection Rating | IP67 |
| Alarm Types | High/Low Concentration, TWA, STEL, Over-range, Low Battery |
| Display | Backlit LCD |
| Alarm Outputs | 6 High-Brightness LEDs, 95 dB Audible, Vibration |
| Data Logging | Internal Memory with Infrared (IR) Data Transfer |
| Power | Replaceable Standard Lithium Battery (2-year typical runtime) |
| Calibration | Compatible with AutoRAELite Automated Calibration System |
| Certifications | ATEX, UL, CSA, IECEx, CMC |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PGM-1820 |
| Pricing | Upon Request |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Instrument Type | Portable VOC Detector |
| Detection Principle | Photoionization Detection (PID) |
| Measurement Range | 0–1000 ppm (standard), 0.1–2000 ppm (extended) |
| Resolution | 1 ppm / 0.1 ppm |
| Response Time | <15 s |
| Certifications | ATEX, UL, CSA, IECEx |
| IP Rating | IP65 |
| Battery Life | Up to 12 hours (rechargeable Li-ion) |
| Data Logging | Internal memory for ≥90 days of time-stamped measurements |
| Display | Backlit graphical LCD with multilingual menu support (including English) |
| Environmental Compensation | Intelligent temperature and zero-point compensation algorithms |
| Enclosure | Stainless steel housing with dust- and water-resistant design |
| Communication | Integrated wireless data transmission (2.4 GHz ISM band, optional Bluetooth or proprietary RF protocol) |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Instrument Type | Portable VOC Detector |
| Detection Principle | Photoionization Detection (PID) with 9.8 eV or 10.6 eV UV Lamp |
| Detection Range | 0.05–5000 ppm, 0.05–9999 ppm, 0.05–2000 ppm, 0.05–200 ppm |
| Resolution | 0.05 ppm, 0.1 ppm, 1 ppm, 0.05 ppm |
| Accuracy | ±3% of reading |
| Response Time | <3 s |
| Built-in Sampling Pump | Yes |
| IP Rating | IP67 |
| Compliance | ATEX II 2G Ex ib IIB T4 Gb, IECEx ib IIB T4 Gb, UL 913 Class I, Division 1, Groups B, C, D, CSA Class I, Division 1, Groups B, C, D |
| Brand | Ratfisch |
|---|---|
| Origin | Germany |
| Model | RS200 |
| Instrument Type | Online Analyzer |
| Typical Configuration | TVOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.01 ppm |
| Accuracy | < ±2% of full scale |
| Response Time (T90) | < 5 s |
| Brand | Ratfisch |
|---|---|
| Origin | Germany |
| Model | RS53-T |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | Flame Ionization Detection (FID) |
| Range | 0–10 / 100 / 1,000 / 10,000 / 100,000 ppm (as propane) |
| Accuracy | ≤ ±1% of reading |
| Repeatability | < ±2% of full scale |
| Response Time | ≤ 2 s (without sampling line) |
| Stability | < ±2% of full scale (zero & span drift over 7 days: < ±2% and < ±4%, respectively) |
| Linearity | ±2% of full scale up to 10,000 ppm |
| Cross-Sensitivity to O₂ | < ±2% of full scale |
| Detection Limit | < 2% of full scale |
| Zero Drift | < ±2% FS/week |
| Span Drift | < ±4% FS/week |
| Sample Flow Rate | ~90 L/h |
| Output Signals | 0–10 V or 0/4–20 mA |
| Operating Temperature | +5 °C to +35 °C |
| Power Supply | 230 V / 50 Hz |
| Dimensions | 360 mm × 200 mm × 500 mm |
| Weight | ~20 kg |
| Certification | TÜV-certified |
| Optional Features | ppb-range capability, heated sampling line, front-mounted particulate filter, integrated zero-air & combustion air supply, H₂ or He/H₂ fuel selector, onboard calibration gas cylinder, onboard fuel cylinder, PC communication software |
| Brand | Ratfisch |
|---|---|
| Origin | Germany |
| Model | RS 55-T |
| Instrument Type | Online Analyzer |
| Typical Configuration | TVOC Analyzer |
| Measurement Principle | Catalytic Combustion (Catalytic Bead) with Propane Calibration |
| Range | 0–10 / 100 / 1,000 / 10,000 / 100,000 ppm (propane) |
| Linearity | ±2% of full scale (up to 10,000 ppm) |
| Cross-Sensitivity | ±2% of full scale @ O₂ |
| Detection Limit | <2% of lowest full-scale range |
| Zero Drift | <2% FS/week |
| Span Drift | <4% FS/week |
| Response Time (T₉₀) | ~1–2 s (without sampling line) |
| Sample Flow Rate | ~220 L/h |
| Output Signals | 0–10 V or 0/4–20 mA |
| Alarm Contacts | Pre-alarm, Main Alarm, Range Identification, Flame-Out Indication, Status Recognition (Zero Gas, Calibration Gas), Pressure/Temperature/Flame Monitoring |
| Operating Ambient Temperature | +5 °C to +35 °C |
| Power Supply | 230 V / 50 Hz, 800 W |
| Dimensions (W×H×D) | 483 mm × 267 mm × 500 mm (19″ rack-mountable) |
| Weight | ~26.5 kg |
| Certification | TÜV-certified per German 17. BImSchV |
| Regulatory Compliance | EPA-compliant methodology for odor reduction quantification |
| Brand | Ratfisch |
|---|---|
| Origin | Germany |
| Model | RS55-T |
| Measurement Principle | Catalytic Combustion (Flame Ionization Detection alternative configuration available per customization) |
| Range | 0–10 / 100 / 1,000 / 10,000 / 100,000 ppm C₃H₈ (propane-equivalent) |
| Linearity | ±2% of full scale up to 10,000 ppm |
| Cross-sensitivity to O₂ | <±2% of full scale |
| Detection Limit | <2% of lowest full-scale range |
| Zero Drift | <2% FS/week |
| Span Drift | <4% FS/week |
| Response Time (T₉₀) | ~1–2 s (sample line excluded) |
| Sample Flow Rate | ~220 L/h |
| Operating Temperature | +5 °C to +35 °C |
| Power Supply | 230 V / 50 Hz, 800 W |
| Dimensions | 483 mm (W) × 267 mm (H) × 500 mm (D) |
| Weight | ~26.5 kg |
| Certified Compliance | TÜV-certified per German 17. BImSchV |
| EPA Method Compatibility | Compliant with EPA Method 25A and 25B requirements for THC monitoring |
| Output Signals | 0–10 V analog, 0/4–20 mA isolated current loop |
| Status Contacts | Pre-alarm, Alarm, Range Identification, Flame-Out Indication, Calibration Mode (Zero/Gas), System Health (Pressure/Temperature/Flame Monitoring) |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | RS-ZSYC-3S-G |
| Instrument Type | Online |
| Measured Parameters | PM2.5, PM10, Sound Pressure Level (Noise) |
| Measurement Principle | Laser Scattering |
| Measurement Range | 0–1000 µg/m³ (PM) |
| Sampling Flow Rate | 16.67 L/min |
| Detection Limit | 1 µg/m³ |
| Temperature Sensor Range | −30 to +70 °C |
| Humidity Sensor Range | 0–99 %RH |
| Wind Speed Range | 0–60 m/s |
| Wind Direction | 8-Point Cardinal |
| Noise Range | 30–130 dB(A) |
| LED Display Size | 57 cm × 105 cm |
| Communication | GPRS |
| Power Supply | AC 220 V |
| Brand | Restek |
|---|---|
| Origin | USA |
| Model | SilcoCan |
| Capacity Options | 1 L, 3 L, 6 L, 15 L |
| Surface Treatment | Siltek®-coated interior and all wetted surfaces |
| Valve Options | Parker diaphragm valve (standard or Siltek®-treated), with or without integrated pressure gauge |
| Compliance | Designed for EPA TO-14A and TO-15 compliance |
| Application Focus | Ultra-trace sulfur compound sampling (1–20 ppb) |
| Key | Brand: Restek |
|---|---|
| Origin | USA |
| Material | Electropolished Stainless Steel (316L) |
| Valve Type | Parker Hannifin Metal-to-Metal Sealed Diaphragm Valve (2/3-turn) |
| Volume Options | 1 L, 3 L, 6 L, 15 L |
| Operating Temperature | Up to 250 °C |
| Internal Surface Treatment | Electropolishing + Ultrasonic Cleaning + Passivation |
| Leak Integrity | Helium-leak tested (<1×10⁻⁹ atm·mL/s) |
| Pressure Rating | 60 psig / Vacuum Range: –30" Hg |
| Compliance | EPA TO-14A, TO-15A, ASTM D5466, USP <661> |
| Brand | Riken |
|---|---|
| Origin | Japan |
| Model | FP-30MK2(C) |
| Detection Principle | Photometric Colorimetry (based on acetylacetone reaction) |
| Measurement Range | 0.000–0.50 mg/m³ (TAB No.008) |
| Resolution | 0.01 mg/m³ (TAB No.008) |
| Repeatability | ≤ ±7% of reading |
| Sampling Method | Pump-aspirated |
| Response Time | 900 s (15 min) for TAB No.009 |
| Operating Temperature | −10 to +40 °C |
| Operating Humidity | ≤90% RH (non-condensing) |
| Flow Rate | 0.5 L/min |
| Data Storage | 99 measurement records with timestamp |
| Power Supply | 4 × AA alkaline batteries |
| Battery Life | Approx. 12 h (at 20 °C, no backlight, no alarm) |
| Dimensions | 80 × 150 × 40 mm (W×H×D, excluding protrusions) |
| Weight | ~250 g (excluding batteries) |
| Brand | Riken Keiki |
|---|---|
| Origin | Japan |
| Model | FP-30MK2(C) |
| Principle | Photometric Colorimetry |
| Measurement Range | 0–0.4 ppm / 0–1.0 ppm (equivalent to 0–0.50 mg/m³ / 0–1.250 mg/m³) |
| Resolution | 0.01 mg/m³ (low range) / 0.025 mg/m³ (high range) |
| Repeatability | ±5% of reading (typical, per JIS B 7981 and GB/T 18204.2–2014) |
| Sampling Method | Pump-aspirated |
| Response Time | t₉₅% ≤ 180 s |
| Operating Temperature | −10 °C to +40 °C |
| Operating Humidity | ≤90% RH, non-condensing |
| Flow Rate | 0.5 L/min |
| Data Storage | 99 auto-saved records |
| Battery Life | ~12 h (4 × AA alkaline, 20 °C, no backlight/alarm) |
| Dimensions | 80 × 150 × 40 mm (W×H×D) |
| Weight | ~250 g (excl. batteries) |
| Certifications | CPA (China Metrology Accreditation), compliant with GB/T 18204.2–2014 and JIS B 7981 |
| Brand | RIKEN KEIKI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TAB-008 / TAB-009 |
| Pricing | Upon Request |
| Detection Principle | Photometric Colorimetry |
| Sampling Method | Pump-Driven Active Inhalation |
| Flow Rate | 0.5 L/min |
| Measurement Range | 0.000–0.500 mg/m³ (TAB-008) |
| Display Resolution | 0.01 mg/m³ (TAB-008) |
| Integration Time | 1800 s (30 min) for TAB-008 |
| Pack Size | 20 strips per pack |
| Brand | RIKEN KEIKI |
|---|---|
| Origin | Japan |
| Model | RX-8500 |
| Type | Portable Multicomponent Gas Detector |
| Detection Principles | NDIR (CH₄, CO₂), Galvanic Cell (O₂), Electrochemical (CO) |
| Response Time | ≤15 s |
| Detection Ranges | CH₄: 0–100% LEL / 5–100 vol% (auto-ranging) |
| O₂ | 0–25 vol% |
| CO | 0–1000 ppm |
| CO₂ | 0–20 vol% |
| Sampling Method | Pump-aspirated |
| Power Supply | Rechargeable Li-ion battery (≈15 h) or 3×AA alkaline batteries (≈8 h) |
| Dimensions | 154(W) × 81(H) × 163(D) mm (excl. protrusions) |
| Weight | ≈1.2 kg (Li-ion), ≈1.1 kg (AA) |
| Operating Environment | −20 to +50 °C, ≤95% RH (non-condensing) |
| Intrinsic Safety Rating | Ex ia II CT4X |
| Certifications | TIIS, ATEX, CE, SOLAS-compliant |
| Brand | Ruinen Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Type | Online Gas Analyzer |
| Model | GC3900N |
| Detection Targets | Total Hydrocarbons (THC), Methane (CH₄), Non-Methane Hydrocarbons (NMHC) |
| Measurement Range | CH₄ (0.1–10,000 ppm), NMHC (0.05–10,000 ppm) |
| LOD | ≤0.1 ppm (CH₄), ≤0.05 ppm (NMHC) |
| Repeatability | RSD ≤2% |
| Cycle Time | ≤40 s (single-channel), ≤20 s (dual-channel) |
| Detector | FID (Flame Ionization Detector) |
| Carrier Gas | Ultra-High-Purity Nitrogen or Zero-Air (≥99.999%) |
| Fuel Gas | Ultra-High-Purity Hydrogen (≥99.999%) |
| Make-up/Support Air | Zero-Air (hydrocarbon <20 ppb) |
| Sampling | Automated Six-Port Valve with Fixed-Volume Loop |
| Sample Temp. Range | Ambient to 180 °C |
| Sample Flow Rate | ≥0.5 L/min or Pressure ≥0.1 MPa |
| Particle-Free Requirement | Yes |
| Form Factor | 6U 19″ Rack-Mount Chassis |
| Power | <400 W, 220 V AC / 50 Hz |
| Analog Output | 4–20 mA |
| Digital Interface | RS232 / RS485 |
| Operating Environment | –10 to +50 °C, 10–100% RH |
| Brand | Ruinen Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Model | RNZ-1000Z |
| Zero Air Purity | NO < 0.1 ppb |
| Flow Rate | 1000 mL/min |
| Output Pressure Range | 0–0.6 MPa |
| Dew Point | −20 °C |
| Hydrocarbon Content (Output) | < 0.1 ppm |
| Max. Inlet Hydrocarbon Concentration | < 100 ppm |
| Inlet Pressure Range | 0–0.6 MPa |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Power Consumption | 350 W |
| Catalyst Operating Temperature | 350–400 °C |
| Ambient Operating Temperature | 0–40 °C |
| Ambient Humidity | < 85 % RH |
| Required Inlet Air | Clean, Dry Compressed Air |
| Communication Interface | RS-485 |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | PG Series |
| Detection Principle | Electrochemical Sensors (H₂S, NH₃, CH₃SH, (CH₃)₂S, CH₃SSCH₃, CS₂, C₈H₈, (CH₃)₃N, NOₓ, O₃) + Optional PID for VOCs |
| Form Factor | Portable |
| Response Time | < 30 s (typical for electrochemical sensors) |
| Repeatability | ±2% FS (for calibrated target gases) |
| Communication Protocols | Modbus RTU/TCP, RS485, Bluetooth/Wi-Fi optional |
| Sensor Interface | Hot-swappable intelligent electrochemical & PID modules |
| Compliance | CE-marked |