Gas Detector
Filter
Showing 2131–2160 of 2974 results
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Model | AtmosFIRt |
| Instrument Principle | Infrared Absorption Spectroscopy |
| Type | Portable Multicomponent Gas Analyzer |
| Response Time (T90) | 120 s (at 1 cm⁻¹ resolution) |
| Repeatability | <1% of full scale |
| Spectral Resolution | Adjustable from 0.5 cm⁻¹ to 8 cm⁻¹ (standard: 1, 2, 4, 8 cm⁻¹) |
| Spectral Range | 485–8500 cm⁻¹ |
| Detection Limits | <0.2 ppm (gas-dependent) |
| Operating Temperature | Up to 180 °C (sample cell) |
| Weight | 21 kg (configurable) |
| Power | 100–250 V AC, 50–60 Hz, 250 W typical |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Model | ProtIR 204M |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Fourier Transform Infrared Spectroscopy (FTIR) |
| Accuracy (Relative Error) | <5% |
| Repeatability | <2% |
| Response Time | <30 s |
| Long-term Stability | <5% over 7 days |
| Measured Gases | SO₂, NO, NO₂, CO, CO₂, HCl, HF, NH₃, CH₄, N₂O, H₂O vapor, and >28 pre-calibrated VOCs & inorganic species |
| Spectral Resolution | 1–128 cm⁻¹ (selectable) |
| Wavenumber Range | 485–8500 cm⁻¹ |
| Optical Path Length | 6.4 m |
| Detector | DTGS |
| IR Source | Globar mid-IR source |
| Beamsplitter | ZnSe |
| Sample Cell Material | Nickel-plated aluminum with gold-coated mirrors & BaF₂ windows |
| Operating Temperature | 5–40 °C |
| Weight | 71 kg |
| Dimensions | 117 × 66.5 × 43 cm |
| Data Interface | Ethernet (OPC DA v3.0 compliant), 16 × 4–20 mA outputs (optional), 5 × digital I/O (optional) |
| Software Suite | PAS, PAS-Pro, Protea Spectrum Viewer |
| Calibration Support | Automated N₂ purge, real-time pressure & temperature compensation, built-in zirconia O₂ sensor (optional), dynamic dilution module (optional) |
| Compliance | UK MCerts certified, compatible with BS EN 14181, EN 15267, ISO 12039, and EPA Method 320 |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Solus NH3 |
| Instrument Type | Portable |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Gases | NH₃ and H₂O (simultaneous) |
| Detection Limit | Sub-ppm NH₃ |
| Response Time | ≤1 s |
| Tuning Range | 2–2.5 nm |
| Spectral Resolution | 0.1 nm |
| Optical Material | Zinc Selenide (ZnSe) |
| Detector | Photodiode |
| Optical Path Length | 0.4 m (standard) |
| Sample Volume | 15 mL |
| Measurement Chamber Temperature | 190 °C |
| Sample Flow Rate | 3 L·min⁻¹ |
| Integrated Sampling System | Heated inlet filter, mass flow controller, automated N₂ purge valve, programmable dilution module |
| Enclosure | Carbon-fiber reinforced composite |
| Weight | 10 kg |
| Dimensions | 46 cm × 35 cm × 17.8 cm (4U, 19″ rack-mountable) |
| Compliance | Designed for GLP/GMP-aligned operation |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SOLUS |
| Instrument Type | Online |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) in Near-Infrared (NIR) |
| Measurement Gases | HCl, NH₃, H₂O (simultaneous or configurable), optionally O₂ (with zirconia sensor) |
| Response Time | < 3 s |
| Sample Volume | 15 mL |
| Integrated Sampling System | Yes (heated filter, purge valve, mass flow control) |
| Housing Material | Carbon fiber composite with thermal insulation |
| Calibration | Zero-point drift-free |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Model | Solus |
| Gas Targets | HCl + H₂O, NH₃ + H₂O |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Form Factor | Portable |
| Sample Volume | 15 mL |
| Response Time | < 3 s |
| Optical Path | Near-Infrared (NIR) |
| Construction | Carbon-fiber chassis with thermal insulation |
| Integrated Components | Heated particulate filter, purge valve, mass flow controller, optional zirconia O₂ sensor and embedded PC |
| Calibration | Zero-point drift-free |
| Compliance Context | Designed for EN 15267-3, MCERTS, EPA Method 320, ISO 14956, and WID (2010/75/EU) emission monitoring applications |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Model | SOLUS-NH3 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) in Near-Infrared (NIR) |
| Target Gases | NH₃, HCl (with H₂O compensation) |
| Response Time | < 3 s |
| Sample Volume | 15 mL |
| Integrated Sampling System | Yes (filter, purge valve, mass flow control) |
| Optional Integrated Zirconia O₂ Sensor | Yes |
| Optional Embedded PC | Yes |
| Construction | Carbon-fiber chassis with thermal insulation |
| Calibration | Zero-air–free operation |
| Compliance | Designed for continuous emissions monitoring (CEM) in accordance with EN 15267, MCERTS, and EPA Method 320 derivatives |
| Brand | PTI (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-780 |
| Measurement Principle | Thermal Conductivity Detection |
| H₂ Range Options | 0–1% |
| Accuracy | ±1% FS (air matrix), ±0.5% FS (CO₂ matrix), ±0.1% FS (CO₂ concentration mode) |
| Response Time | ≤10 s |
| Operating Pressure | 0–1.0 MPa |
| Ambient Temperature Range | −30 °C to +60 °C |
| Storage Temperature | −40 °C to +70 °C |
| Display | 800×480 true-color TFT touchscreen |
| Power Supply | 220 VAC ±10%, 50 Hz / Rechargeable Li-ion battery (≥8 h continuous operation) |
| Data Logging | 128 entries with timestamp, local storage & export capability |
| Calibration | Field-executable zero/span calibration |
| Brand | PULUODY |
|---|---|
| Model | DPC-2615 |
| Instrument Type | Handheld |
| Flow Rate | 1.0 L/min |
| Flow Accuracy | ≤ ±5% |
| Timing Accuracy | ≤ ±1 s |
| Repeatability | ≤ ±5% |
| Size Distribution Accuracy | ≤ ±5% |
| Indication Error | ≤ ±5% |
| PM Measurement Channels | PM1.0, PM2.5, PM10, TSP |
| Mass Concentration Range | 0–10 mg/m³ (extendable to 100 mg/m³) |
| Laser Source | IEC 60825-1 Class 2 |
| Response Time | 1 s |
| Data Storage Capacity | ≥ 7,000,000 records |
| Battery Life | ≥ 4.5 h @ 25°C, 50% RH |
| Operating Temperature | −20 to +60°C |
| Relative Humidity Range | 0–99% RH |
| Atmospheric Pressure Range | 86–110 kPa |
| Power Input | DC 16.8 V / 1 A |
| Rated Power | 4.1 W |
| Display | 3.5-inch touchscreen |
| Dimensions | 175 × 105 × 65 mm |
| Weight | 0.89 kg |
| Calibration Traceability | NIST-traceable standard particles |
| Compliance Standards | HJ 1263–2022, WS/T 206–2001, LD 98–1996, GB/T 45795–2025, AQ/T 4268–2015 |
| Brand | PULUODY |
|---|---|
| Model | DPC-2615A |
| Instrument Type | Handheld |
| Flow Rate | 1 L/min |
| Flow Accuracy | ≤±5% |
| Timing Error | ≤±1 s |
| Repeatability | ≤±5% |
| Size Distribution Error | ≤±5% |
| Indication Error | ≤±5% |
| PM1.0 Accuracy | ±9.5% or ±7.5 µg/m³ |
| TSP Accuracy | ±15% or ±25 µg/m³ |
| Operating Temperature | −20–60 °C |
| Relative Humidity Range | 0–99% RH |
| Atmospheric Pressure Range | 86–110 kPa |
| Response Time | 1 s |
| Data Storage Capacity | ≥7,000,000 records |
| Battery Life | ≥4 h (25 °C, 50% RH) |
| Laser Source | IEC 60825-1 Class 2 |
| Compliance Standards | HJ 1263–2022, WS/T 206–2001, LD 98–1996, GB/T 45795–2025, AQ/T 4268–2015 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | PULL-GP20-1000 |
| Instrument Type | Standard Gas Sampler |
| Configuration | Single-Port Sampling Cylinder |
| Flow Range | 0–20 L/min |
| Maximum Sampling Pressure | 0–20 MPa |
| Flow Stability | ±1% FS |
| Flowmeter Accuracy | ±1% FS |
| Service Life Under Max Flow & Backpressure | ≥100,000 cycles |
| Continuous Operation at Max Flow & Backpressure | 24 h |
| Working Pressure Range | 4–20 MPa |
| Burst Pressure Rating | 7–38 MPa |
| Operating Temperature Range | –60 °C to +80 °C |
| Cylinder Material | ASTM A240 UNS S31603 (316L stainless steel) or GB/T 1220 1Cr18Ni9Ti |
| Internal Coating (Optional) | PTFE lining |
| Pressure Gauge | Integrated bourdon-tube gauge with direct-read dial |
| Valve Configuration | Dual-valve assembly — one standard needle valve, one pressure-relief safety valve with burst disc |
| Mounting Bracket | 304 stainless steel support stand (optional) |
| Volume Capacity | 1000 mL |
| Compliance | SH/T 0233–1992, SY/T ZJ1045 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PULL-GP20-300 |
| Instrument Type | Single-Channel Cryogenic Gas/Liquid Sampler |
| Flow Range | 0–20 L/min |
| Maximum Operating Pressure | 4–20 MPa |
| Flow Stability | ≤5% over 1 h |
| Flowmeter Accuracy | ≥±2.5% FS |
| Service Life at Max Flow & Backpressure | ≥5000 h |
| Continuous Operation Duration at Max Flow & Backpressure | 8 h |
| Construction Material | ASTM A240 316L Stainless Steel |
| Operating Temperature Range | –190 °C to +80 °C |
| Volumetric Capacity Options | 100 mL to 5000 mL |
| Compliance | SH/T 0233–1992 (Liquefied Petroleum Gas Sampling Method) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PULL-GP20-500 |
| Instrument Type | General-Purpose Gas Sampler |
| Configuration | Single-Channel Sampling System |
| Flow Rate Range | 0–0.5 L/min |
| Maximum Suction Pressure | 0–20 MPa |
| Flow Stability | ≤ ±5% |
| Flowmeter Accuracy | ≥ ±2.5% |
| Service Life at Max Flow & Backpressure | ≥ 5000 h |
| Drift Under Rated Load | ≤ ±5% |
| Material | 1Cr18Ni9Ti Stainless Steel (AISI 321 Equivalent) |
| Design Pressure | 20 MPa |
| Hydrostatic Test Pressure | 35 MPa |
| Operating Temperature Range | –60 °C to +80 °C |
| Available Volumes | 25 mL to 10,000 mL |
| Compliance | SH/T 0233, SY/T 1045 |
| Brand | PyroScience |
|---|---|
| Origin | Germany |
| Model | RF-O2 Environmental |
| Measurement Principle | Fluorescence Quenching of Oxygen-Sensitive Dyes |
| Optical Sensor Technology | REDFLASH (Rapid Excitation and Detection of Fluorescence) |
| Channel Options | 1-, 2-, or 4-Channel Configurations |
| Power Supply | USB 5V DC (20 mA) |
| Dimensions | 78 × 120 × 24 mm |
| Weight | 290 g |
| Operating Temperature | 0–50 °C, non-condensing |
| Integrated Sensors | Barometric pressure (300–1100 mbar, ±3 mbar accuracy), Relative humidity (0–100 %RH, ±0.2 %RH), Pt100 temperature input |
| Sampling Rate | 10–20 Hz per channel |
| Analog Output | 0–2.5 VDC |
| Interface | USB 2.0, UART serial |
| Software Suite | Pyro Workbench (device control & calibration), Pyro Data Inspector (respiration rate calculation, drift correction, TOU analysis) |
| Oxygen Ranges | Full-scale: 0–100 %O₂ (gas phase), 0–44 mg/L (dissolved O₂) |
| Trace | 0–21 %O₂ (gas), 0–9 mg/L (dissolved) |
| LOD | 0.02 %O₂ / 0.01 mg/L (full-scale), 0.005 %O₂ / 0.002 mg/L (trace) |
| Temperature Compensation | Real-time, integrated |
| Sensor Compatibility | Contact-type (probes, needles, bare fiber, solvent-resistant, insertion) and non-contact (optode films, flow cells, respirometry chambers) |
| Compliance | Designed for GLP-aligned workflows |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QC-1S |
| Price Range | USD 140–700 (FOB) |
| Instrument Type | Conventional Gas Sampler |
| Configuration | Single-Channel Sampling System |
| Flow Rate Range | 0.1–1.5 L/min |
| Maximum Vacuum Pressure | >26 kPa |
| Flow Stability | ≤±5% |
| Flowmeter Accuracy Class | 2.5 |
| Service Life (at Max Flow & Backpressure) | 5–10 Years |
| Continuous Operation Duration (at Max Flow & Rated Resistance) | 2–8 h |
| Load Capacity | >1 L/min at 4 kPa Backpressure |
| Timing Accuracy | <0.1% |
| Operating Temperature | −10 to +45 °C |
| Dimensions (W×H×D) | 100 × 150 × 52 mm |
| Net Weight (incl. Rechargeable Battery) | 550 g |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QC-2 |
| Pricing | Available Upon Request |
| Sampling Flow Rate | 0.1–1.5 L/min |
| Flow Stability | ≤5% |
| Flow Accuracy | ≤5% |
| Timing Range | 1–99 min |
| Timing Accuracy | <0.1% |
| Operating Temperature | −10 to 40 °C |
| Battery-Operated Continuous Runtime | >6 h |
| Dimensions (L×W×H) | 210 × 125 × 95 mm |
| Weight (incl. battery) | 2.8 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QC-2 / QC-2A |
| Price Range | USD 140–700 |
| Instrument Type | Conventional Gas Sampler |
| Configuration | Dual-Channel Portable Sampler |
| Flow Rate Range | 0.1–1.5 L/min |
| Maximum Vacuum Pressure | >26 kPa |
| Flow Stability | ≤5% fluctuation (under load) |
| Flowmeter Accuracy | Class 2.5 (per GB/T 1226–2017 / equivalent to ISO 5167 Class 2.5) |
| Service Life (at max flow & resistance) | 5–10 years |
| Continuous Operation Duration (at max flow & 4.5 kPa backpressure) | 2–8 h |
| Timer Range | 1–99 min, timing error <0.1% |
| Power Supply | AC/DC dual-mode |
| Dimensions | 210 × 125 × 95 mm |
| Weight | 2.9 kg |
| Pump Type | Diaphragm vacuum pump (QC-2A variant features high-torque diaphragm pump optimized for VOC sampling with elevated backpressure tolerance) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QC-2B |
| Price Range | USD 140–700 (FOB) |
| Instrument Type | Conventional Gas Sampler |
| Configuration | Dual-Independent-Channel Sampling System |
| Flow Range | 0.1–1.5 L/min |
| Maximum Vacuum Pressure | >26 kPa |
| Flow Stability | ≤5% |
| Flowmeter Accuracy Class | 2.5 |
| Service Life Under Max Load & Backpressure | 5–10 years |
| Continuous Operation Duration at Max Flow & Rated Resistance | 2–8 h |
| Rated Flow | 2.5 L/min @ 4.5 kPa Backpressure |
| Timing Range | 1–99 h (adjustable in 1-min increments) |
| Timing Accuracy | ≤0.01% (based on real-time clock) |
| Dimensions | 210 × 125 × 95 mm |
| Power Supply | AC/DC dual-mode (rechargeable Ni-MH battery included) |
| Battery Runtime | ≥6 h continuous operation |
| Operating Temperature | −10 °C to +40 °C |
| Net Weight | 2.8 kg (including battery) |
| Control Architecture | Dual-channel independent electronic timer with synchronized start/stop capability |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QC-2B |
| Pricing | Available Upon Request |
| Sampling Flow Rate | 0.1–1.5 L/min |
| Flow Stability | ≤5% |
| Flow Accuracy | ≤5% |
| Timing Range | 1–99 min per channel |
| Timing Accuracy | <0.1% |
| Operating Temperature | −10 to 40 °C |
| Battery Runtime | >6 hours |
| Dimensions (L×W×H) | 210 × 125 × 95 mm |
| Weight (incl. battery) | 2.8 kg |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QC-6H |
| Pricing | Available Upon Request |
| Flow Range | 0.4–0.6 L/min |
| Max. Negative Pressure | 20 kPa |
| Flow Stability | ≤5% |
| Flow Accuracy | ±5% (within −6 kPa) |
| Timer Range | 1–99 min (±0.1% error) |
| Power Supply | AC 220 V / 50 Hz or DC 7.4 V Li-ion battery |
| Continuous Operation | ≥6 h |
| Operating Temperature | −10 to +45 °C |
| Dimensions | 210 × 125 × 80 mm |
| Weight (incl. battery) | 1470 g |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | QCD Series |
| Pricing | Upon Request |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | QMG 250 |
| Detection Principle | Quadrupole Mass Spectrometry |
| Configuration | Online, Integrated Vacuum System |
| Mass Range | up to 300 amu |
| Repeatability | ≤ ±0.5% RSD (for masses < 300) |
| Response Time | < 1 s (typical for partial pressure monitoring) |
| System Includes | QMG 250 quadrupole mass spectrometer, HiCube 80 turbomolecular pump set, PKR 251 cold cathode vacuum gauge, and custom four-way stainless-steel chamber assembly |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | RA-915J |
| Pricing | Upon Request |
| Brand | RAE Systems Inc. (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PGM-5520 |
| Instrument Type | Portable |
| Detectable Gases | O₂, LEL (Combustible Gas), CO, H₂S |
| Response Time | ≤15 s |
| Measurement Resolution | 1 ppm |
| Measurement Ranges | O₂ (0–30% vol), LEL (0–100% LEL), CO (0–500 ppm), H₂S (0–100 ppm) |
| Wireless Frequency | 915 MHz |
| Integrated Sampling Pump | Yes |
| IP Rating | IP67 (per ASTM E2782 & IEC 60529) |
| Battery Life | Up to 24 h (typical, with Li-ion battery) |
| Data Logging Capacity | ≥100,000 data points |
| Simultaneous Monitoring Channels | Up to 32 units per base station |
| Mounting | Bi-Pod stand (50 cm elevation, tool-free attachment) |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FMC 2000 |
| Pricing | Upon Request |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | MeshGuard Wireless Gas Detector |
| Pricing | Available Upon Request |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MeshGuard |
| Pricing | Upon Request |
| Brand | RAE Systems Inc. (USA) |
|---|---|
| Origin | USA |
| Model | MicroRAE |
| Detection Principle | Electrochemical (CO, H₂S), Catalytic Bead (LEL), Galvanic Cell (O₂) |
| Form Factor | Portable |
| Response Time (T₉₀) | ≤30 s |
| Repeatability | ±2% of reading (O₂, LEL, CO, H₂S) |
| IP Rating | IP67 |
| Operating Temperature | −40 °C to +70 °C (2 h at extremes) |
| Battery Life | 15 h (non-wireless), 11 h (wireless enabled, 20 °C) |
| Wireless Protocols | Proprietary RAE Mesh (up to 200 m), Bluetooth Low Energy (up to 5 m) |
| Certifications | IECEx Ex ia d IIIC T4 Gb, China Ex d ia IIIC T4 Gb, CMC, CCCF |
| Sensor Configuration | O₂ (0–30.0% vol, 0.1% vol res.), LEL (0–100% LEL, 1% LEL res.), CO (0–1000 ppm, dual-range: 0–250 ppm @ 1 ppm |
| 250–1000 ppm @ 3 ppm), H₂S (0–100 ppm, dual-range | 0–50 ppm @ 0.1 ppm |
| Data Logging | Continuous 6-month storage (1-min interval, 4 sensors) |
| Alarm Types | Audible (100 dB @ 30 cm, multi-tone), visual (tricolor LED, monochrome display with dual-color backlight), vibratory, remote (via ConneXt Plus/Pro/Loneworker, Safety Communicator), fall detection with pre-alarm and real-time transmission |
| Calibration | Two-point (manual or AutoRAE 2 automated) |
| Dimensions | 117 × 76 × 24 mm (H×W×D) |
| Weight | 206 g (incl. Li-ion battery & belt clip) |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Instrument Type | Portable Gas Detector |
| Detection Principle | Photoionization Detection (PID) |
| Detection Range | 0.1–15,000 ppm (isobutylene-equivalent) |
| Resolution | 0.1 ppm |
| Accuracy | ±3% of reading |
| Response Time (T90) | <2 s |
| Sampling Method | Integrated high-performance pump with optional 30 m sampling hose |
| Environmental Compensation | Integrated temperature, humidity, and barometric pressure sensors with auto-compensation algorithm |
| Communication | Built-in Bluetooth 4.0 or optional 802.11 Wi-Fi module |
| Display | Backlit graphical LCD with multilingual UI (including English, Spanish, French, German, Chinese) |
| Gas Library | Preloaded database covering >2,000 VOCs and selected inorganic compounds |
| Certifications | ATEX II 2G Ex ib IIB T4 Gb, IECEx ib IIB T4 Gb, UL 913 Class I, Division 1, Groups B, C, D, CSA C/US Class I, Div. 1, Groups B, C, D |
| Brand | RAE Systems Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PGM-7300 |
| Detection Principle | Photoionization Detection (PID) |
| Instrument Type | Portable |
| Configuration | Multi-gas VOC Detector |
| Detection Range | 0.1–5000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±3% of reading |
| Response Time | T90 ≤ 2 s |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PGM6208 |
| Instrument Type | Portable |
| Detection Targets | Multi-component (EC, LEL, TC, PID, IR, Gamma) |
| Measurement Range | 0–1 ppm (select sensors) |
| Repeatability | ≤1% FS |
| Resolution | 0.1 ppm (standard) |
| Response Time (T90) | ≤60 s |
| Zero Drift | ≤±5% FS (per 8 h) |
| Span Drift | ≤±1% FS (per 8 h) |
| Linearity Error | ≤±2% FS |
| Certifications | ATEX II 1G Ex ia IIC T4 Ga, UL 913 Class I Div 1 Groups A–D, CSA C22.2 No. 152, IECEx, CMC |