Industry-specific Instruments
Filter
Showing 4231–4260 of 6344 results
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | BOR-3000 |
| Application | Friction and Wear Testing |
| Compliance | ASTM D3704, D2509, D2782, D2981, G77, G176 |
| Max Load | 10,000 N |
| Max Speed | 5000 rpm |
| Temp Range | Up to 500 °C |
| Torque Measurement | In-line high-resolution |
| Test Modes | Continuous, Reciprocating, Stepped Load, Oscillatory |
| Sample Mounting | Modular block holder for shafts, bearings, seals, rings, thrust/conical rollers |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | FBT-1000 |
| Test Types | EP (Extreme Pressure) and Wear Testing |
| Temperature Range | –40 °C to 200 °C (optional up to 400 °C) |
| Maximum Load | 12,000 N |
| Rotational Speed | Up to 1800 rpm |
| Real-time Monitoring | Torque, Load, Temperature, Acoustic Emission, Friction Coefficient |
| Compliance | ISO 12583, ASTM D2266, D2596, D2783, D4172, DIN 51350, BS EN ISO 20623, CEC L-45-A-99 |
| Sample Compatibility | Lubricating oils, greases, additives, solid lubricants |
| Data Resolution | Sub-micron wear scar measurement via integrated 3D profilometry |
| Brand | Rtec |
|---|---|
| Origin | USA |
| Model | FBT-12000 |
| Load Capacity | Up to 12,000 N (closed-loop servo-controlled) |
| Torque Measurement Range | 0–20 N·m |
| Rotational Speed | 0–3000 rpm (0.1 rpm resolution) |
| Temperature Range | Ambient to +150 °C |
| Optional Low-Temperature Control | Ambient to –40 °C |
| Compliance | ASTM D2596, D2783, D2266, D4172, D5183 |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | FFT-M |
| Application | Lubricity & Wear Evaluation of Diesel/Gasoline Fuels |
| Standards Compliance | ASTM D6079, ISO 12156-1, SH/T 0765-2005 |
| Frequency Range | 0.1–300 Hz |
| Stroke | 10 µm–4.0 mm |
| Load Capacity | Up to 10 N or 300 N (configurable) |
| Temperature Range | −40 °C to +500 °C |
| Humidity Control | 5–95% RH (closed-loop) |
| Ball Diameter | Standard 6 mm (1.6–12.7 mm optional) |
| Disk Dimensions | 10 mm diameter × 3 mm thickness (custom sizes available) |
| Real-time Force Feedback | Piezoelectric load sensor |
| Friction & Wear Output | Dynamic coefficient of friction, total wear scar depth, acoustic emission, in-situ film formation monitoring |
| Environmental Control | Inert gas purge capability (N₂, Ar), programmable atmosphere management |
| Brand | Rtec |
|---|---|
| Origin | USA |
| Model | FFT-M1 |
| Application | Tribological Evaluation of Fuels and Lubricants |
| Compliance | ASTM D6079, ISO 12156-1, SH/T 0765, EN 590, JPI-5S-50-9, IP 450 |
| Load Range | 0–1.0 kg |
| Frequency Range | 1–300 Hz |
| Stroke Amplitude | 0.005–2 mm |
| Operating Temperature | Ambient to +200 °C |
| Test Mode | Boundary Lubrication Assessment under Oscillatory Sliding Conditions |
| Brand | Rtec |
|---|---|
| Origin | USA |
| Model | MFT-3000 |
| Load Range | 0–3000 N |
| Reciprocating Stroke | 0–30 mm |
| Frequency Range | 0–80 Hz |
| Temperature Control | Ambient to +500 °C (up to +1000 °C optional) |
| Low-Temperature Option | Ambient to –60 °C |
| Thermal Cycling Option | –40 °C to +180 °C |
| Rotational Mode (optional) | 0.1–5000 rpm, 0.1 rpm resolution |
| Compliance | ASTM G133, G181, G119, G174, D5706, D5707, SH/T 0784, SH/T 0721, DIN 51834 |
| Brand | Rtec |
|---|---|
| Origin | USA |
| Type | Electromagnetic Oscillating Tribometer |
| Load Range | 1–3000 N |
| Frequency Range | 1–500 Hz |
| Oscillation Amplitude | 0.005–4 mm |
| Temperature Range | Ambient to +400 °C (optional up to +1000 °C) |
| Force Sensing | High-accuracy piezoelectric tribosensors |
| Displacement Monitoring | LVDT-based real-time closed-loop control |
| Compliance Standards | ASTM D5706, D5707, D6425, D7421, D7594, E2789 |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | TTQ-1000 |
| Application | Tribological Evaluation of Cutting, Threading & Drilling Lubricants |
| Measurement Principle | In-situ Rotational Torque + Acoustic Emission + Electrical Contact Resistance + Environmental Temperature Monitoring |
| Sample Types | Aluminum, Steel, and Other Machinable Metals |
| Test Modes | Automated Multi-position Tapping, Drilling, and Milling Simulation |
| Compliance Context | Supports ASTM D3702, ISO 20623, and GLP-aligned data integrity requirements |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | RPA elite |
| Drive Type | Direct-drive motor with high-resolution strain control |
| Torque Sensor | Patented high-stiffness, wide-range sensor with low noise floor |
| Frame Stiffness | Ultra-rigid monolithic frame eliminating instrument compliance |
| Temperature Control | Integrated gas-cooling unit for rapid and stable thermal regulation |
| Pressure Control | Pneumatically actuated, user-adjustable die closure pressure |
| Automation | Optional robotic autosampler for unattended operation |
| Calibration | User-performed torque and geometry calibration |
| Compliance | Designed to support ASTM D6204, ISO 6673, and ISO 10985 test methods |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | RPA Flex |
| Drive Type | High-Resolution Direct-Drive Motor |
| Torque Sensor | Patented High-Stiffness, Wide-Range Transducer |
| Frame | Ultra-Rigid Monolithic Structure |
| Control | Fully Programmable Strain, Frequency, Temperature, Time, and Mold Closure Pressure |
| Automation | Integrated Robotic Sample Handler |
| Mold Closure | Pneumatically Actuated, Adjustable Pressure Disc |
| Calibration | User-Executable with Replaceable Die Plates |
| Upgrade Path | Field-Upgradeable to Extended Frequency and Strain Range |
| Brand | Rubolab |
|---|---|
| Model | Smart Filtration Kit |
| Origin | Spain |
| Instrument Type | Online Monitoring System |
| Measured Parameters | Foam Characteristics, Particle Count (ISO/NAS Code), Demulsibility Indicator (via OilWear Sensor Platform), Optional Water Content (ppm) |
| Flow Control | Integrated Flow Meter & Regulator |
| Compliance | ISO 4406, ISO 11171, ASTM D892, ASTM D2711, ISO 6247 |
| Software | Rubolab OilWear™ Cloud Platform with Audit Trail & Exportable CSV/Excel Reports |
| Certifications | CE, RoHS, Designed for GLP/GMP Environments |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-100C |
| Detection Method | Enzyme Inhibition (Test Strip-Based) |
| Measurement Range | 0–99.9% inhibition rate |
| Detection Limit | 0.05 ppm |
| Accuracy | ±10% |
| Repeatability | ≤5% |
| Channel Count | 1 |
| Display | Color LCD |
| Power Supply | Integrated Lithium Battery (8 h continuous operation) |
| Dimensions | 175 × 100 × 85 mm |
| Connectivity | Bluetooth 4.0 |
| Data Output | Wireless transmission to regulatory platforms & mobile app integration for traceability and certificate generation |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-1217C |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 12 |
| Measurement Error | ≤10% |
| Limit of Detection (LOD) | 0.3 ppm |
| Display | 7-inch color TFT touchscreen |
| Wavelength | 410 nm |
| Absorbance Range | 0.000–4.000 |
| Absorbance Resolution | 0.001 |
| Transmittance Range | 0.00–100.00% |
| Transmittance Resolution | 0.01% |
| Photometric Accuracy (Transmittance) | ≤2.0% |
| Photometric Repeatability (Transmittance) | ≤0.2% |
| Photocurrent Drift | ≤0.2% (within 3 min) |
| Inhibition Rate Accuracy | ±10% |
| Inhibition Rate Repeatability | ≤5% |
| Internal Data Storage Capacity | 10,000 test records |
| Communication Interfaces | RS-232 and USB |
| Power Supply | 220 V ±10% AC |
| Dimensions (W×D×H) | 410 × 290 × 150 mm |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | CNY-1217D |
| Detection Method | Spectrophotometric Colloidal Gold Immunoassay |
| Measurement Range | 0–100% inhibition |
| Number of Detection Channels | 12 |
| Measurement Error | <10% |
| Limit of Detection (LOD) | 0.2 ppm |
| Display | 10.1-inch color capacitive touchscreen |
| Operating System | Android |
| Data Storage | Internal + microSD expansion (up to 200,000 records) |
| Connectivity | Wi-Fi, optional 3G/4G/5G, GPS/AGPS interface |
| Printing | Thermal label printer (compliant with MOA’s “Edible Agricultural Products Certificate Management Measures”) |
| Optical Performance | Absorbance range 0.000–4.000 A |
| Power Supply | 220 V ±10% |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CNY-1217LS |
| Detection Method | Enzyme Inhibition (Spectrophotometric) |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 12 |
| Measurement Error | <10% |
| Limit of Detection (LOD) | 0.2 ppm |
| Display | 7-inch color TFT touchscreen |
| Wavelength | 410 nm |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy (T) | ±2.0% |
| Photometric Repeatability (T) | ≤0.2% |
| Photocurrent Drift (3 min) | ≤0.3% |
| Inhibition Rate Accuracy | ±10% |
| Inhibition Rate Repeatability | ≤5% |
| Interface | RS232 & USB |
| Power Supply | 220 V ±10% |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1218C |
| Detection Method | Enzyme Inhibition Rate (Spectrophotometric) |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 12 |
| Measurement Error | <10% |
| Limit of Detection (LOD) | 0.2 ppm |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy (T) | ±1.5% |
| Photometric Repeatability (T) | ≤0.2% |
| Photocurrent Drift | ≤0.2% (3 min) |
| Power Supply | AC 220 V ±10% |
| Display | 10.1-inch capacitive touchscreen (1024 × 600), IP65-rated front panel, 400 cd/m² brightness |
| OS | Android 7.0, quad-core 1.8 GHz CPU, 2 GB RAM, 16 GB internal storage + microSD expansion |
| Connectivity | Dual USB 2.0, Wi-Fi (802.11 b/g/n), RJ45 Ethernet, optional 3G/4G/5G module, GPS/AGPS |
| Data Export | Excel (.xlsx) via USB drive |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-1218CY |
| Function Type | Multi-analyte (Pesticide Residue Screening) |
| Sample Type | Single-sample dedicated platform |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per sample |
| Photometric Repeatability | ≤0.2% (T) |
| Optical Channels | 12 colorimetric + 3 colloidal gold lateral flow channels |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±2.0% T |
| Dark Current Drift | ≤0.2% over 3 min |
| Measurement Accuracy | ±5% (vs. reference standards) |
| Display | 10.1″ capacitive touch LCD (1024×600), IP65-rated front panel, 400 cd/m² brightness |
| OS | Android 7.0, Quad-core 1.8 GHz CPU, 2 GB RAM, 16 GB internal storage |
| Connectivity | Dual-band Wi-Fi, RJ45 Ethernet, Bluetooth 4.2, optional 3G/4G/5G module |
| Integrated Thermal Printer | Label & A4 report output |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-1218D |
| Detection Method | Enzyme Inhibition Rate (Spectrophotometric) |
| Measurement Range | 0–100% inhibition |
| Number of Spectrophotometric Channels | 12 |
| Number of Colloidal Gold Lateral Flow Channels | 3 (expandable to 10) |
| Measurement Accuracy | ±5% |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy (T) | ±2.0% |
| Photometric Repeatability (T) | ≤0.2% |
| Photocurrent Drift | ≤0.2% (over 3 min) |
| LOD for Organophosphates & Carbamates | 0.2 ppm |
| Display | 10.1-inch capacitive touchscreen (Android OS) |
| Connectivity | Dual USB, Wi-Fi, RJ45 Ethernet, optional 3G/4G/5G module |
| Power Supply | 220 V ±10% |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1218DJ |
| Detection Methods | Spectrophotometry & Colloidal Gold Immunochromatography |
| Measurement Range | 0–100% (Relative Inhibition or Signal Intensity) |
| Number of Channels | 12 (Spectrophotometric) + 3 (Colloidal Gold, expandable to 10) |
| Measurement Accuracy | ±5% |
| Absorbance Resolution | 0.001 A |
| Transmittance Resolution | 0.01% T |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Photocurrent Drift | ≤0.2% (within 3 min) |
| Detection Limit | 0.2 ppm (for representative organophosphates and carbamates) |
| Display | 10.1-inch TFT-LCD touchscreen (1024 × 600), IP65-rated front panel, 400 cd/m² brightness |
| Operating System | Android 7.0, Quad-core 1.8 GHz CPU, 2 GB RAM, 16 GB internal storage |
| Connectivity | Dual-band Wi-Fi, RJ45 Ethernet, Bluetooth 4.2, optional 3G/4G/5G module |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Data Export | USB 2.0 ×2, Cloud API support for real-time upload and traceability |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CNY-1218LS |
| Function Type | Multi-analyte (Pesticide Residues, Mycotoxins, Heavy Metals) |
| Sample Compatibility | Universal for Grains and Cereals |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min per assay |
| Photometric Repeatability | ≤0.2% T |
| Absorbance Repeatability | ≤0.3% |
| Optical Channels | 12 photometric + 3 colloidal gold (expandable to 10) |
| Display | 10.1″ TFT-LCD, 1024×600, IP65-rated front panel |
| Operating System | Android 7.0 (Quad-core, 1.8 GHz, 2 GB RAM, 16 GB storage) |
| Data Connectivity | Wi-Fi, RJ45 Ethernet, optional 3G/4G/5G module |
| Power Supply | AC 220 V ±10% |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CNY-1218NS |
| Price | USD 5,300 (FOB Shanghai) |
| Function Type | Multi-analyte (Pesticide, Veterinary Drug, Mycotoxin & Heavy Metal Residues) |
| Sample Compatibility | Universal for Solid & Liquid Food Matrices |
| Wavelength Range | 380–680 nm |
| Detection Time per Sample | ≤ 180 s |
| Photometric Repeatability | ≤ 0.2% T |
| Absorbance Repeatability | ≤ 0.3% |
| Optical Channels | 12 photometric + 3 colloidal gold lateral flow readers |
| Display | 10.1″ capacitive touchscreen (Android OS) |
| Data Connectivity | Wi-Fi, RJ45 Ethernet, optional 4G LTE module |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1218ZF |
| Detection Method | Enzyme Inhibition Assay (Spectrophotometric) |
| Measurement Range | 0–100% Inhibition |
| Number of Spectrophotometric Channels | 12 |
| Number of Colloidal Gold Lateral Flow Channels | 3 |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy (Transmittance) | ±2.0% T |
| Photometric Repeatability (Transmittance) | ≤0.2% T |
| Photocurrent Drift | ≤0.2% (over 3 min) |
| Measurement Accuracy | ±5% |
| LOD for Organophosphates & Carbamates | 0.2 ppm |
| Power Supply | AC 220 V ±10% |
| Display | 10.1-inch Capacitive Touchscreen (Android OS) |
| Connectivity | Dual USB, Wi-Fi, RJ45 Ethernet, Optional 4G LTE Module |
| Internal Storage | ≥32 GB |
| Battery | Integrated Rechargeable Li-ion (up to 6 h operation) |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1218ZY |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤3 min |
| Repeatability | ≤0.2% (T) |
| Optical Channels | 12 (spectrophotometric) + 3 (colloidal gold, expandable to 10) |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±2.0% T |
| Photocurrent Drift | ≤0.2% (3 min) |
| Measurement Accuracy | ±5% |
| Display | 10.1-inch Android touchscreen |
| Connectivity | Dual USB, Wi-Fi, RJ45, optional 3G/4G/5G |
| Power Supply | 220 V ±10% AC |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-12K |
| Detection Method | Enzyme Inhibition Rate Method |
| Measurement Range | 0–100% |
| Number of Channels | 12 |
| Measurement Error | ≤10% |
| Limit of Detection (LOD) | 0.3 ppm |
| Temperature Control Range | 30–50 °C ±0.5 °C |
| Preheating Time Setting | 1–99 min |
| Reaction Time Setting | 1–99 min |
| Power Supply | AC 220 V / DC 12 V / Internal Rechargeable Battery (3.6 V / 1400 mAh) |
| Dimensions | 325 × 100 × 40 mm |
| Weight | ~600 g |
| Carrying Case Dimensions | 400 × 290 × 120 mm |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-1617C |
| Price | USD 2,500 (FOB Shanghai) |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% Inhibition Rate |
| Number of Channels | 16 |
| Measurement Error | ≤ ±10% |
| Limit of Detection (LOD) | 0.3 ppm for organophosphates and carbamates |
| Wavelength | 410 nm |
| Absorbance Range | 0.000–4.000 |
| Absorbance Resolution | 0.001 |
| Transmittance Range | 0.00–99.99% |
| Transmittance Resolution | 0.01% |
| Photometric Accuracy (Transmittance) | ≤ ±2.0% |
| Photometric Repeatability (Transmittance) | ≤ ±0.2% |
| Photocurrent Drift | ≤ ±0.2% (within 3 min) |
| Inhibition Rate Display Range | 0.00–99.99% |
| Inhibition Rate Repeatability | ≤ ±5% |
| Internal Data Storage Capacity | 10,000 test records |
| Communication Interface | USB |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Dimensions (W×D×H) | 410 × 290 × 150 mm |
| Display | 7-inch color TFT LCD touchscreen with full Chinese GUI |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1618 |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% Inhibition |
| Number of Channels | 16 |
| Measurement Error | ±10% |
| Limit of Detection (LOD) | 5% Inhibition |
| Display | 10.1-inch TFT LCD Touchscreen (1024×600) |
| Absorbance Range | 0.000–4.000 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Absorbance Resolution | 0.001 A |
| Photometric Accuracy | ±1.5% T |
| Photometric Repeatability | ≤0.2% T |
| Dark Current Drift | ≤0.2% (3 min) |
| Power Supply | AC 220 V ±10% |
| Connectivity | Dual USB, Wi-Fi, RJ45 Ethernet, Optional 3G/4G/5G Module, GPS/AGPS |
| Operating System | Android 7.0 (Quad-Core, 1.8 GHz, 2 GB RAM, 16 GB Storage) |
| IP Rating | IP65 (Front Panel) |
| Data Export | Excel via USB or SD card |
| Throughput | Up to 180 samples/hour |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-1618C |
| Detection Method | Enzyme Inhibition (Spectrophotometric) |
| Measurement Range | 0–100% Inhibition |
| Number of Channels | 16 |
| Measurement Error | <10% |
| Limit of Detection (LOD) | 0.2 ppm |
| Display | 10.1-inch TFT LCD Touchscreen (1024×600), IP65-rated front panel |
| Operating System | Android 7.0 (Quad-core, 1.8 GHz, 2 GB RAM, 16 GB internal storage + microSD expansion) |
| Optical Performance | Absorbance range 0.000–4.000 A |
| Throughput | Up to 180 samples/hour |
| Connectivity | Dual USB 2.0 ports, Wi-Fi (802.11 b/g/n), RJ45 Ethernet, optional 3G/4G/5G module, GPS/AGPS |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Compliance | Designed per GB 5009.199–2003 and NY/T 448–2001 |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | CNY-1618NS |
| Function Type | Multi-analyte (pesticide, veterinary drug, mycotoxin & heavy metal residues) |
| Sample Compatibility | Universal for agricultural commodities (fruits, vegetables, grains, tea, aquatic products, livestock tissues, eggs) |
| Wavelength Range | 400–680 nm |
| Detection Time | ≤10 min per sample |
| Repeatability (CV) | <5% |
| Optical Channels | 12 independent photometric channels |
| Absorbance Range | 0.000–4.000 A |
| Absorbance Resolution | 0.001 A |
| Transmittance Range | 0.00–100.00% T |
| Transmittance Resolution | 0.01% T |
| Photometric Accuracy (T) | ±2.0% |
| Photometric Repeatability (T) | ≤0.2% |
| Dark Current Drift | ≤0.2% (3 min) |
| Measurement Accuracy | ±5% |
| Integrated Lateral Flow Immunoassay (LFIA) Module | 3 strips |
| Display | 10.1-inch capacitive touchscreen (Android OS) |
| Data Connectivity | Wi-Fi, RJ45 Ethernet, optional 3G/4G/5G module |
| Storage | Internal high-capacity flash memory + dual USB ports |
| Database | Preloaded Chinese national standard sample library (>1,000 entries) with pinyin-based search |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-16ZD |
| Price Range | USD 7,000–14,000 (FOB) |
| Function Type | Multi-analyte Detection Platform |
| Sample Applicability | Broad-spectrum for fruits, vegetables, and aqueous extracts |
| Wavelength Range | 380–680 nm (Primary Detection at 412 nm) |
| Assay Time per Sample Batch | ≤3 min |
| Photometric Repeatability | ≤0.3% CV |
| Detection Channels | 16 independent optical channels |
| Incubation Temperature Control | 37.0 °C ±0.5 °C |
| Operating System | Android-based embedded UI |
| Display | 7-inch capacitive color touchscreen |
| Data Storage Capacity | ≥10,000 assay records (1,000 visible on-screen) |
| Connectivity | Wi-Fi, dual USB 2.0 ports, RJ45 Ethernet |
| Power Supply | AC 220 V / DC 12 V |
| Net Weight | 7 kg |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CNY-2417C |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 24 |
| Measurement Error | ≤10% |
| Limit of Detection (LOD) | 0.3 ppm |
| Display | 7-inch color TFT touchscreen |
| Wavelength | 410 nm |
| Absorbance Range | 0.000–4.000 |
| Absorbance Resolution | 0.001 |
| Transmittance Range | 0.00–99.00% |
| Transmittance Resolution | 0.01% |
| Photometric Accuracy (Transmittance) | ≤2.0% |
| Photometric Repeatability (Transmittance) | ≤0.2% |
| Photocurrent Drift | ≤0.2% (within 3 min) |
| Inhibition Rate Accuracy | ±10% |
| Inhibition Rate Repeatability | ≤5% |
| Internal Data Storage Capacity | 10,000 test records |
| Communication Interface | USB |
| Power Supply | 220 V ±10% AC |
| Dimensions (L×W×H) | 410 × 290 × 150 mm |