| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K88539 |
| Product Type | Laboratory Instrument |
| Test Parameter | Air Release Time (ART) |
| Standards Compliance | ASTM D3427, IP 313, ISO 9120, DIN 51381, NF E 48-614, NF T 60-149, BS 2000 Part 313 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | K88629 |
| Measurement Parameters | Gasoline Octane Number, Diesel Cetane Number |
| Portability | Portable |
| Detection Principle | Near-Infrared (NIR) Transmission Spectroscopy |
| Measurement Range | Octane Number: 40–120 |
| Cetane Number | 20–100 |
| Accuracy | ±0.5 ON |
| Measurement Time | <20 s |
| Sample Volume | 225 mL |
| Repeatability | Equivalent to ASTM D2699 and D2700 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K92095 |
| Standard Compliance | ASTM D2509, ASTM D2782 |
| Rotational Speed Range | 100–800 rpm |
| Test Load Ramp Rate | 0.9–1.3 kg/s |
| Specimen Dimensions | 12.32 × 12.32 × 19.1 mm |
| Test Cup OD | 49.22 mm |
| Weight | 52 kg |
| Automatic Grease Feed Rate | 45 ± 10 g/min |
| Recirculating Fluid Reservoir Capacity | 3 L |
| Timer Range | 99 h : 59 min : 59 s |
| Loading Arm Ratio | 1:10 |
| Power Supply | 230 V, 50 Hz |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K93100 |
| Power Supply | 220 V / 60 Hz (3-phase) or 440 V / 50 Hz (3-phase) |
| Motor | 1.5 kW |
| Test Speeds | 1200, 1440, 1760 rpm (optional: 1000/3000 or 300/3000 rpm) |
| Test Duration Range | 1–9999 min |
| Ball Diameter | 12.7 mm |
| Transport Weight | 620 kg |
| Transport Volume | 1.27 m³ |
| Compliant Standards | ASTM D2266, D2596, D2783, D4172, D5183 |
| Includes | TriboDATA software, calibrated weights, ball holder assembly, ball cup, ball extractor, ball rack, ball clamp, base plate, hand tools, wrenches, electrical controller, interconnect cables, calibration & test report |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K93170 |
| Compliance | ASTM D2266, D4172, D5183, D2596, D2783 |
| Max Load | 1000 kg (servo-pneumatic closed-loop) |
| Speed Range | Up to 2000 rpm (AC servo-controlled) |
| Temperature Range | Ambient to 200 °C (integrated thermal module) |
| Friction Force Resolution | Digital load cell with real-time acquisition |
| Control Interface | 15″ multi-touch integrated panel |
| Data Interface | USB 3.0 |
| Dimensions (W×D×H) | 62.5 × 50 × 90 cm |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K94190 |
| Compliance | ASTM D5001 |
| Test Principle | Ball-on-Cylinder Lubricity Evaluation (BOCLE) |
| Sample Volume | 50 ± 1.0 mL |
| Test Temperature | 25 ± 1 °C |
| Regulated Air RH | 10 ± 0.2 % at 25 °C |
| Dry/Air Flow Rates | 0.5 L/min (through sample), 3.8 L/min (over test surface) |
| Load | 1000 g (±1 g) |
| Cylinder Speed | 240 ± 0.5 rpm |
| Test Duration | 30 ± 0.1 min |
| Test Ring | SAE 8720 steel, Ø49.10–49.25 mm × 13.0–13.11 mm, hardness 58–62 Rc, Rq 0.51–0.71 µm |
| Test Ball | AISI 52100 steel, Ø12.7 mm, hardness 64–66 Rc |
| Power Supply | 230 V AC, single-phase, 5 A |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K94454 |
| Compliance | ASTM D6138, ISO 11007, DIN 51802, BS 2000-220, IP 220, SIS 155130, NFT 60-135 |
| Test Positions | 4 |
| Rotational Speed | 80 rpm (adjustable) |
| Test Duration | 168 h (customizable) |
| Power Supply | 110–230 V, 50/60 Hz, ≤150 W |
| Dimensions (Base Unit) | 480 × 250 × 200 mm (W × D × H) |
| Expansion Module Dimensions | 260 × 230 × 170 mm |
| Control Interface | PLC-based touchscreen panel |
| Sample Media | Grease, lubricating oil, or other test media in presence of distilled water, deionized water, NaCl solution, or synthetic seawater |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K95100 |
| Standards Compliance | ASTM D36, ISO 4625, EN 1427, DIN 52011, AFNOR T66-008, IP 58, NF EN 1427 |
| Heating Range | 30–157 °C (86–315 °F) |
| Media Options | Distilled water (30–80 °C), USP glycerin (80–157 °C), ethylene glycol (30–110 °C) |
| Power | 3000 W |
| Electrical | 110–240 VAC, 50/60 Hz, 1500 W (single-phase) |
| Dimensions | 39.1 × 43.7 × 62.0 cm (15.4 × 17.2 × 24.4 in) |
| Net Weight | 32.7 kg (72 lb) |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K95200 |
| Product Type | Laboratory Instrument |
| Test Parameter | Grease Adhesion Force |
| Accuracy | <0.1 N |
| Load System | Electromechanical Control |
| Sample Mass | 5 g |
| Test Duration | ~120 s |
| Result Units | N, N/mm², N/in² |
| Test Speed | 250 mm/s (standard) |
| PLC | Siemens S7-1200 + 7" HMI Touchscreen |
| Interface | Ethernet |
| Temperature Range | Ambient to 80 °C |
| Voltage | 110–230 V AC, 50–60 Hz |
| Dimensions (H×W×D) | 620 × 300 × 320 mm |
| Weight | 30 kg |
| Optional Accessory | K95200-1 Temperature-Controlled Test Chamber |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K95300 |
| Pressure Range | 0–3000 mBar |
| Pressure Resolution | <1 mBar |
| Temperature Range | Ambient to –50 °C |
| Temperature Resolution | <1 °C |
| Control System | Integrated Touchscreen PLC |
| Data Interface | Ethernet |
| Air Pressure Source | Internal Compressor |
| Power Supply | 110/230 V, 50–60 Hz |
| Dimensions (W×D×H) | 230 × 320 × 440 mm |
| Weight | 25 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K95400 |
| Product Type | Laboratory Instrument |
| Test Parameter | Grease Bleedability (Penetrability under Pressure) |
| Operating Temperatures | 0 °F, 30 °F, 75 °F |
| Dimensions | 38 × 15 × 13 cm |
| Weight | 5.4 kg |
| Power Requirement | None |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K95590 |
| Penetration Range | 0–62.0 mm (0–620 penetration units) |
| Resolution | 0.1 mm or 0.01 mm |
| Penetration Time | 0.1–9999.9 s (default: 5.0 s) |
| Dimensions | 31.7 × 35.6 × 45.7 cm |
| Weight | 9.5 kg |
| Power Supply | 220–240 V, 50/60 Hz |
| Compliance | ASTM D5, D217, D937, D1321, D1403, D2884, D4950 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | KLA-1-TS / KLA-2-TS / KLA-3-TS |
| Temperature Range | +80 °C to –80 °C |
| Resolution | 0.06 °C |
| Accuracy | ±0.1 °C |
| Repeatability | Compliant with or better than ASTM D2500, D97, D5771–D5773, D5853, D5950 |
| Cooling System | Dual-stage thermoelectric (Stage 1: –40 °C |
| Stage 2 | –80 °C) |
| Display | 6.4″ TFT/LCD touchscreen (640 × 480, 262K color) |
| Data Storage | >60,000 test records in Microsoft Excel-compatible format |
| Compliance | ASTM, ISO, DIN, IP standards per model configuration |
| Sample Detection Method | Coaxial fiber-optic pulse photometry (cloud point) |
| Max. Test Heads | 6 |
| Power Supply | 220 V ±15%, 50–60 Hz |
| Dimensions | 66 × 60 × 80 cm |
| Weight | 80 kg |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OIL-1 |
| Pricing | Upon Request |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K18200 Series Oxidation Stability Tester |
| Standards Compliance | ASTM D2112, D2272, D4742 |
| Operating Pressure | 90 psi (620 kPa) initial, up to 500 psi (3450 kPa) burst rating |
| Temperature Range | Ambient to 200 °C |
| Control Stability | ±0.02 °C |
| Rotation Speed | 100 rpm ± 1 rpm |
| Bath Capacity | 68 L (2-cell), 95 L (3-cell), 121 L (4-cell) |
| Heating Power | 0–2750 W (2/3-cell), 0–3750 W (4-cell) |
| Drive Motor | 0.5 hp continuous-duty, spherical bearing, integrated gear reduction |
| Bearing Type | PTFE-coated carbon fluoropolymer |
| Pressure Sensing | Direct-mount transducer on oxygen bomb |
| Safety | Auto-shutdown at >177 °C or >16.7 °C above setpoint |
| Software | Oxidata™ v5.x (Windows-based, FDA 21 CFR Part 11–ready audit trail, GLP-compliant data archiving) |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Koenen Test Apparatus |
| Price Range | USD 27,000 – 68,000 |
| Brand | SMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Koenen |
| Price Range | USD 14,000 – 70,000 |
| Sample Tube Dimensions | 75 mm length × 25 mm OD |
| Sample Tube Mass | 25.5 ± 1.0 g |
| Orifice Diameters | 1.0, 1.5, 2.0, 2.5, 3.0, 5.0, 8.0, 12.0, 20.0 mm |
| Heating Rate | 3.3 ± 0.3 K/s |
| Propane Supply | 500 mbar regulated |
| Ignition System | Remote Electronic Controller |
| Power Supply | 110 V / 60 Hz or 220 V / 50 Hz |
| Compliance | ASTM E681, UN Manual of Tests and Criteria Part I, Section 15, ISO 8767 |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HT-201 |
| Price | Upon Request |
| Brand | Korno |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GT-903-H2 |
| Price Range | USD 270 – 1,100 (FOB) |
| Detection Principle | Electrochemical / Thermal Conductivity |
| Gas Detected | H₂ |
| Range Options | 0–100 / 500 / 1,000 / 2,000 / 5,000 / 10,000 / 40,000 ppm |
| Resolution | 0.1 ppm (≤1,000 ppm), 1 ppm (≤40,000 ppm), 0.01% vol |
| T90 Response Time | ≤20 s |
| Accuracy | ≤±3% FS |
| Linearity Error | ≤±2% FS |
| Zero Drift | ≤±2% FS |
| Recovery Time | ≤20 s |
| Sensor Channels | 1–4 configurable |
| Explosion Protection | Ex ib IIC T4 Gb (per GB/T 3836.4–2021) |
| Ingress Protection | IP67 |
| Operating Temp | −20 °C to +50 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Pressure Range | 88–112 kPa |
| Battery | 3800 mAh rechargeable polymer Li-ion |
| Display | 2.4″ industrial-grade color LCD |
| Data Storage | 120,000 records (on-device review & USB export) |
| Sampling Method | Built-in micro-diaphragm pump |
| Compliance | GB/T 3836.1–2021, GB/T 3836.4–2021 |
| Brand | Korno |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | MOT500-H2-A |
| Price | Upon Request |
| Detection Gas | Hydrogen (H₂) |
| Sensor Type | Imported High-Performance Electrochemical Sensor |
| Measurement Ranges | 0–100, 1000, 5000, 20,000, 40,000, or 50,000 ppm (selectable) |
| Resolution | 0.01 ppm (0–100 ppm) |
| Response Time (T90) | ≤20 s |
| Accuracy | ≤±3% FS (sensor-dependent) |
| Linearity Error | ≤±2% FS |
| Zero Drift | ≤±2% FS |
| Recovery Time | ≤30 s |
| Sensor Expansion | Up to 6 sensors (optional) |
| Repeatability | ≤±2% FS |
| Explosion Protection Certification | CCRI24.8021X |
| Ingress Protection Rating | IP66 |
| Temperature & Humidity Sensing (optional) | -20–50 °C |
| Sampling Method | Diffusion, Pipe-Insertion, Flow-Through, or Pump-Suction (selectable) |
| Mounting Options | Wall-Mount, Pipe-Mount (M40×1.5 mm thread), Flow-Through |
| Output Signals | 4–20 mA (16-bit, up to 1 km) |
| Transmission Modes | Shielded cable (3–4 core) |
| Compatible Receivers | PC, PLC, DCS, alarm controllers, smartphones, tablets |
| Alarm Types | Local audible/visual alarm |
| Alarm Configuration | Dual-level standard (tripoint optional) |
| Housing Material | Die-cast aluminum with sandblasted anodizing or fluorocarbon coating |
| Operating Environment | -20–50 °C |
| Power Supply | 24 VDC (12–30 VDC) |
| Electrical Interface | 3/4″ NPT internal thread + G1/2″ internal thread (dual compatibility) |
| Dimensions & Weight | 226 × 215 × 85 mm (L×W×H) |
| Standard Accessories | User manual, calibration hood, certificate of conformity |
| Optional Accessories | IR remote control, DC12/24V adapter, USB/RS232 converter, RS485/RS232 adapter, sampling pump, flow meter, flow cell, mounting bracket |
| Compliance Standards | GB/T 3836.1–2021, GB/T 3836.2–2021, GB/T 3836.31–2021 |
| Brand | Koyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | FRL-3000 |
| Quotation | Upon Request |
| Heat Capacity (Water Equivalent) | ~10,500 J/K (≈2,500 cal/K) |
| Oxygen Bomb Working Pressure | 2.8–3.0 MPa (max 3.2 MPa) |
| Oxygen Bomb Hydrostatic Test Pressure | 20 MPa |
| Oxygen Bomb Volume | 300 mL |
| Oxygen Bomb Mass | 50 kg |
| Inner Bucket Water Volume | ~2,100 mL |
| Outer Jacket Water Volume | ~40 L |
| Precision | ≤0.1% |
| Temperature Measurement Range | 5–40 °C |
| Temperature Resolution | 0.001 K |
| Brand | Koyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | KY-200 Microcoulometric Sulfur Analyzer |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Analyte | Total Sulfur |
| Measurement Principle | Microcoulometric Titration (ASTM D3229 / SH/T 0253-92 / GB/T 11061-1997 / SH/T 0222-1992) |
| Sample Forms | Liquid, Solid, Gas (with optional injectors) |
| Detection Range | 0.2–10,000 mg/L S |
| LOD | 0.2 mg/L S |
| Repeatability | ±0.1 mg/L (0.5–1.0 mg/L) |
| Furnace Temp Control | Ambient to 1100 °C, ±1 °C |
| Carrier Gases | Technical-grade O₂ and N₂ |
| Cooling | Air-cooled裂解 furnace with auto-start/stop fan |
| Power Requirement | 1500 W |
| Brand | KPM Analytics |
|---|---|
| Origin | Italy |
| Model | EyePro Q-Bake |
| Detection Speed | Up to 100 objects/sec |
| Integration | Inline conveyor-compatible |
| Camera Options | Top, side, and optional bottom imaging |
| Measurement Capability | 2D & 3D morphological analysis |
| Predefined Metrics Library | >100 configurable parameters |
| Output Data | Real-time OEE metrics (uptime, throughput, rejection rate), audit-ready CSV/Excel reports |
| Compliance Support | Designed for food industry traceability requirements (aligned with ISO 22000, BRCGS Food Safety Issue 9, and FDA FSMA §117.135) |
| Brand | KPM CHOPIN |
|---|---|
| Origin | France |
| Model | AlveoPC |
| Compliance | AACC 54-30.02, ICC 121, NF EN ISO 27971, GB/T 14614.4 |
| Application Domain | Wheat breeding, flour milling, grain procurement, food processing, official quality inspection |
| Brand | KPM CHOPIN |
|---|---|
| Origin | France |
| Model | CD1 |
| Type | Laboratory-scale roller mill for wheat flour milling simulation |
| Application | Flour yield determination, short-patent milling flow optimization, millability assessment |
| Compliance | Designed per ISO 27990 (Cereal and cereal products — Determination of flour yield), aligned with AACC Method 26–50A and ICC Standard No. 171 |
| Brand | KPM CHOPIN |
|---|---|
| Origin | France |
| Model | Mixolab 2 |
| Compliance | ISO 17718:2013, AACC 54-60-01, ICC 173-1, GOST R 54498-2011, GOST R ISO 17718-2015, GB/T 37511-2019 |
| Brand | KPM CHOPIN |
|---|---|
| Origin | France |
| Model | Rheo F4 |
| Application | Fermentation & Dough Rheology Analysis for Gluten-Free, Whole Wheat, and Pre-Fermented Products |
| Category | Food-Specific Quality Instrumentation |
| Compliance Context | Designed for ISO 21502, AACC Method 54-10A, and ASTM D7908 (Rheological Characterization of Leavened Dough Systems) |
| Brand | KPM CHOPIN |
|---|---|
| Origin | France |
| Model | SDmatic 2 |
| Measurement Principle | Amperometric iodine binding assay (Medcalf & Gilles method) |
| Compliance | NF EN ISO 17715:2015, ICC 172, AACC 76-33.01, GB/T 31577-2015 |
| Sample Requirement | 1 g flour |
| Analysis Time | <10 min per test |
| Display | 7-inch color touchscreen |
| Data Storage | Internal database + USB export |
| Connectivity | Ethernet/LAN for LIMS integration |
| Electrode Maintenance | User-replaceable |
| Firmware Update | Online (via network) or offline (via USB drive) |
| Software Features | Protocol customization (flour mass, iodine reaction time, measurement duration), unit selection, guided workflow, learning mode, timer |
| Brand | Kaufman & Robinson, Inc. (KRi) |
|---|---|
| Origin | USA |
| Model | EH200 |
| Type | End-Hall Ion Source |
| Application | Ion Beam Etching (IBE), Pre-deposition Substrate Cleaning, Ion-Assisted Deposition (IBAD), Ion Beam Sputtering (IBS), Direct Ion Plating (DIP) |
| Operating Gas | Argon (Ar), Oxygen (O₂), Nitrogen (N₂), or mixtures |
| Typical Beam Voltage | 50–1,200 V |
| Typical Beam Current | 0.1–4.0 A |
| Nominal Beam Power | Up to 3.5 kW |
| Ion Beam Diameter (at 10 cm) | ~80–120 mm |
| Cooling | Conduction-cooled (water-cooled optional) |
| Interface | CF-63 or CF-100 flange mount |
| Control | Analog 0–10 V / 4–20 mA or RS-232/RS-485 (with optional digital controller) |
| Compliance | CE-marked |
| Brand | KRI (Kaufman & Robinson, Inc.) |
|---|---|
| Origin | USA |
| Model | EH1020F |
| Type | End-Hall Ion Source (Ungridded Hall-Effect Ion Source) |
| Beam Current Range | 0.1–2.5 A (adjustable) |
| Operating Voltage | 50–150 V (DC) |
| Gas Compatibility | Ar, O₂, N₂, Xe, or mixed gases |
| Typical Anode Power | 50–300 W |
| Cooling | Conduction-cooled (water-cooling optional) |
| Flange Interface | CF-63 or CF-100 (customizable) |
| Lifetime | >10,000 hours (under nominal operating conditions) |
| Compliance | CE-marked, RoHS-compliant, compatible with UHV and HV vacuum systems (≤1×10⁻⁷ mbar base pressure) |