| Brand | KRI (Kaufman & Robinson, Inc.) |
|---|---|
| Origin | USA |
| Model | RFICP 140 |
| Anode RF Power | 1 kW @ 1.8 MHz |
| Max. Beam Current | >500 mA |
| Acceleration Voltage Range | 100–1200 V |
| Ion Energy Range | 100–1200 eV |
| Beam Aperture Diameter | 14 cm |
| Grid Material | Molybdenum or Graphite |
| Gas Compatibility | Ar, O₂, N₂, and other process gases |
| Gas Flow Rate | 5–40 sccm |
| Operating Pressure | < 0.5 mTorr |
| Neutralizer | LFN 2000 |
| Dimensions (H × D) | 25.1 cm × 24.6 cm |
| Flange | 12″ Conflat (CF) |
| Brand | KRI (Kaufman) |
|---|---|
| Origin | USA |
| Model | RFICP 200 HO |
| Discharge Type | RF Inductive |
| Filamentless Operation | Yes |
| RF Power Input | >1 kW |
| Ion Optics | OptiBeam™ Grid Assembly |
| Grid Configuration | Application-Specific, Self-Aligning |
| Neutralizer | Integrated (Optional) |
| Cooling | Water-Cooled |
| Beam Options | Collimated, Convergent, Divergent |
| Compliance | Designed for UHV-compatible vacuum systems (≤1×10⁻⁷ Torr operating base pressure) |
| Brand | KRI (Kaufman & Robinson, Inc.) |
|---|---|
| Origin | USA |
| Model | RFICP 220 |
| Anode RF Power | 2 kW @ 2 MHz |
| Max. Beam Current | >1000 mA |
| Beam Energy Range | 100–1200 eV |
| Operating Gases | Ar, O₂, N₂, and other process gases |
| Gas Flow Rate | 5–50 sccm |
| Chamber Pressure | <0.5 mTorr |
| Grid Diameter | 22 cm |
| Grid Material | Molybdenum |
| Beam Optics | OptiBeam™ self-aligning ion optics |
| Neutralizer | LFN 2000 or MHC 1000 |
| Dimensions (H × D) | 30 cm × 41 cm |
| Flange | 10" ConFlat (CF) |
| Brand | Kaufman & Robinson, Inc. (KRI) |
|---|---|
| Origin | USA |
| Model | RFICP 325 |
| Type | RF Inductively Coupled Plasma Ion Source |
| Grid Configuration | E22 Gridded |
| Beam Coverage | Up to 1650 mm substrate holder diameter |
| Application | Ion Beam Assisted Deposition (IBAD) and Pre-deposition Substrate Cleaning |
| Brand | KRI (Kaufman & Robinson, Inc.) |
|---|---|
| Origin | USA |
| Model | RFICP40 |
| Ion Beam Current | Up to 1.2 A (typical, scalable by aperture and gas flow) |
| Operating Gases | Ar, O₂, N₂, Xe, or mixtures |
| RF Frequency | 13.56 MHz |
| Nominal Beam Energy Range | 50–1500 eV (adjustable via extraction voltage) |
| Extraction Aperture Diameter | 40 mm |
| Vacuum Compatibility | ≤5×10⁻⁴ Torr (base pressure), ≥1×10⁻³ Torr (operational) |
| Cooling | Water-cooled anode and cathode assembly |
| Compliance | CE-marked, RoHS-compliant, compatible with ISO 9001-certified vacuum integration workflows |
| Brand | KRK |
|---|---|
| Origin | Japan |
| Model | KRK-2500Ⅱ |
| Type | Single-Disk Refiner |
| Liquid-Wetted Material | SUS-316 Stainless Steel |
| Disc Diameter | 305 mm |
| Rotor Speed | 3,000 rpm (standard) |
| Motor Power | 22 kW / 30 kW |
| Feed Screw Speed | 30–300 rpm |
| Gap Resolution | 0.01 mm |
| Overall Dimensions | 1030 × 1440 × 1270 mm |
| Weight | 800 kg |
| Electrical Supply | 200/220 V, 3-phase DC, 50/60 Hz, 107 A |
| Cooling Water Required | Yes |
| Brand | KRK |
|---|---|
| Origin | Japan |
| Model | KRK-2511 |
| Power Supply | 380 V, 3-phase, 50/60 Hz |
| Net Weight | 450 kg |
| Gross Weight | 500 kg |
| Dimensions (W×D×H) | 780 × 550 × 1100 mm |
| Roll-to-Plate Linear Speed Differential | 6 ± 0.2 m/s |
| Compliance | ISO 5264-2:1979, QB/T 1463–1992 |
| Brand | KC Starlight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KS-9A |
| Price | USD 1,150 (FOB) |
| Temperature Range | 79 °C to 400 °C |
| Ignition Source | High-Stability Silicon Nitride Igniter |
| Repeatability | ≤4 °C |
| Applicable Standards | GB/T 3536, ASTM D92 |
| Accuracy | ±2 °C |
| Reproducibility | ≤8 °C |
| Heating Rate | Compliant with GB/T 3536 |
| Resolution | 0.1 °C |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤550 W |
| Dimensions (W×D×H) | 410 × 320 × 165 mm |
| Net Weight | 14.5 kg |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | Kubelka |
| Pricing | Upon Request |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-0125 |
| Price | Upon Request |
| Applicable Standard | ASTM D2420, SH/T 0125 |
| Heating Method | Electric Tubular Heater |
| Temperature Control | Digital PID Controller with PT100 Sensor |
| Flow Regulation | Adjustable Needle Valve with Flowmeter |
| Total Power | 1000 W |
| Power Supply | AC 220 V, 50 Hz |
| Detection Limit | 4 mg/m³ H₂S |
| Interference Profile | Methyl mercaptan causes transient yellow staining on lead acetate paper (<5 min fade) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | KY-0125 |
| Price | Upon Request |
| Applicable Standard | ASTM D2420, SH/T 0125 |
| Heating Method | Electric Tubular Heater |
| Temperature Control | Digital PID Controller with PT100 Sensor |
| Flow Regulation | Adjustable Needle Valve + Visual Flowmeter |
| Total Power | 1000 W |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Producer |
| Country of Origin | China |
| Model | KY-0231 |
| Quotation | Upon Request |
| Applicable Standard | SH/T 0231 |
| Wet Gas Meter Capacity | 2 L |
| Stainless Steel Hollow Needle | φ1 × 0.2 mm |
| Measurable H₂S Range | 5–500 mg/m³ |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | KY-102 |
| Measurement Principle | Infrared Absorption (CO₂ & SO₂) |
| Carbon Range | 0.005–10.0000% (extendable to 99.999%) |
| Sulfur Range | 0.0005–0.3500% (extendable to 99.999%) |
| Analysis Time | ~35 s (excluding sample weighing) |
| Detection Limit | 200 ppm |
| Sample Mass | 100 mg – 1 g |
| Repeatability | ±200 ppm (200–1000 ppm) |
| Weighing Capacity | 0–100 g |
| Readability | 0.001 g |
| Required Gas | O₂ at 0.5 MPa, ≥99.7% purity |
| Combustion Methods | Tube Furnace (for viscous samples), Arc Furnace (for solid samples) |
| Compliance Standards | GB/T 223.69–1997 (C), GB/T 223.68–1997 (S) |
| Interface | Windows-based GUI with real-time curve display |
| Data Acquisition | PCI-bus integrated control and acquisition system |
| Detector | Low-noise, high-sensitivity, anti-interference infrared detector |
| Channel Configuration | 16 independent channels for carbon, 16 for sulfur (32 total, user-configurable) |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Producer |
| Region Classification | Domestic (China) |
| Model | KY-104C |
| Pricing | Upon Request |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | KY-106 |
| Price | USD 7,400 (approx. based on ¥53,000 at 1 USD = ¥7.2) |
| Potential Range | −2.0 to +2.0 V |
| Potential Resolution | < 50 mV (peak separation) |
| Detection Limit | 1 × 10⁻⁷ mol/L |
| Supported Techniques | CV, SCV, LSV, CA, DPV, NPV, NEOP, SWV, i–t, CC |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-20 |
| Force Range Options | 0–100 N / 0–200 N / 0–500 N (user-selectable) |
| Sensitivity | 0.1 N |
| Accuracy | ≤0.5% F.S. ± 0.1 N |
| Particle Diameter Capacity | 0–20 mm (granules) |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | KY-200 |
| Price | USD 1,700 (FOB Jiangsu) |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-200 Sulfur Analyzer |
| Price | USD 9,200 (FOB Jiangsu) |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Producer |
| Country of Origin | China |
| Model | KY-200A |
| Pricing | Upon Request |
| Measurement Principle | Microcoulometric Titration (ASTM D5808 / GB/T 18612) |
| Sample Forms | Liquid, Solid, Gas (with optional injectors) |
| Chlorine Range | 0.1–10,000 mg/L |
| Detection Limit | 0.1 mg/L |
| Precision | RSD ≤20% (≤1.0 mg/L), ≤8% (1.0–100 mg/L), ≤3% (>100 mg/L) |
| Temperature Control | Ambient to 1100 °C ±1 °C |
| Carrier Gases | Industrial-grade O₂ and N₂ |
| Cooling Method | Intelligent Fan-cooled Cracking Furnace |
| Power Consumption | 1.5 kW |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-3000S A |
| Detection Principle | UV Fluorescence (ASTM D5453, ISO 20846, UOP 971) |
| Sample Forms | Liquid, Solid, Gas (with optional dedicated injectors) |
| Sulfur Measurement Range | 0.2 mg/L to 100% w/w |
| LOD | 0.2 mg/L (as S) |
| Furnace Temperature Range | Ambient to 1100 °C |
| Temperature Control Accuracy | ±0.5% of setpoint or ±3 °C (whichever is greater) |
| Carrier Gas | High-purity Argon (≥99.98%) and Oxygen (≥99.98%) |
| Power Consumption | 2 kW |
| Dimensions (L×W×H) | 680 × 480 × ~520 mm |
| Data Acquisition | 24-bit ADC, USB 2.0 interface, minimum detectable signal < 1 µV |
| PMT Voltage | Adjustable, software-controlled |
| Calibration Options | Single-point or multi-point calibration using certified SRMs |
| Software Compatibility | Windows 10/11, 64-bit |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | KY-4 |
| Pricing | Upon Request |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | KY-403 |
| Measurement Range | ≥0.001 mg KOH/g |
| Potentiometric Range | −2000.0 to +2000.0 mV |
| Basic Electrical Error | ±0.1% F.S. + 0.1 mV |
| Input Impedance | ≥1 × 10¹² Ω |
| Burette Capacity | 10 mL |
| Minimum Dispensing Volume | 0.001 mL |
| Burette Accuracy | ±0.1% F.S. |
| Precision | Compliant with or Exceeding GB/T 18609 and GB/T 7304 |
| Operating Temperature | 0–35 °C |
| Power Supply | AC 220 V ± 22 V, 50 Hz |
| Brand | Keyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | KY-4S |
| Pricing | Upon Request |
| Sample Type | Liquid |
| Analytical Method | Potentiometric Titration |
| Detection Limit | ≥3 µg/g |
| Minimum Titrant Dispense Volume | 0.01 mL |
| Potentiometric Range | 0 to ±1999.5 mV |
| Burette Accuracy | ±0.1% F.S. |
| Electronic Unit Basic Error | ±0.1% of full scale + 0.5 mV |
| Relative Standard Deviation | ≤5% |
| Compliance Standard | GB/T 1792–1988 “Determination of Mercaptan Sulfur in Distillate Fuels” |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | KY-4Wa |
| Pricing | Upon Request |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | KY-104 |
| Price | USD 2,100 (FOB) |
| Measurement Range | 5–1000 mg/L COD (dilution required above 1000 mg/L) |
| Accuracy | ±5 mg/L (5–100 mg/L), ±5% RSD (100–1000 mg/L) |
| Chloride Interference Tolerance | <1000 mg/L Cl⁻ |
| Digestion Time | 10–120 min |
| Compliant Standards | APHA Standard Method 5220D, US EPA Method 410.4 |
| Light Source | Monochromatic Cold LED |
| Detection Principle | Fixed-Wavelength Colorimetry (610 nm typical) |
| Data Processing | Embedded MCU with Linear Regression Algorithm |
| Sample Introduction | Pneumatic Pressure-Driven Auto-Sampling |
| Temperature Control | PID-Regulated Heating Block (±0.5 °C) |
| Output | Thermal Printer Integration, USB Data Export |
| Brand | Kyoyuan |
|---|---|
| Model | KY-2000 |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Pricing | Upon Request |
| Measurement Principle | Thermogravimetric Analysis (TGA) |
| Analysis Time | < 20 min per sample |
| Moisture Accuracy | ±0.5% |
| Volatile Matter Accuracy | ±0.5–1.5% |
| Ash Content Accuracy | ±0.3–0.7% |
| Higher Heating Value Accuracy | ±0.5–1.5 MJ/kg |
| Lower Heating Value Accuracy | ±0.5–1.5 MJ/kg |
| Operating System | Windows-based control software (Chinese UI) |
| Optional Modules | Unburned Carbon in Fly Ash (Loss on Ignition for ash residue) |
| Brand | Kyoyuan |
|---|---|
| Model | KY-200AOX |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance | HJ 1214–2021, GB/T 22904–2008 |
| Temperature Range | 100–1150 °C |
| Temperature Control Accuracy | ±1 °C |
| Detection Range | 0.028–1000 mg/L (100 mL sample volume) |
| LOD | 0.007 mg/L as Cl⁻ |
| Analysis Time | 3–10 min (excluding sample pretreatment) |
| Carrier Gas | O₂ ≥99.9% |
| Sample Introduction | Modified quartz boat with direct liquid/solid injection capability |
| Sample Mass | 50 mg |
| Power Consumption | 1.5 kW |
| Electrical Supply | 220 V, 50 Hz |
| Net Weight | ~15 kg |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-200S |
| Detection Target | Total Sulfur |
| Measurement Principle | Microcoulometric Titration (ASTM D3227, SH/T 0253, GB/T 11061.4, SH/T 0222, GB/T 3208) |
| Sample Forms | Liquid, Solid, Gas (with optional injectors) |
| Sulfur Range | 0.1 mg/L to 10,000 mg/L |
| Detection Limit | 0.1 mg/L (as S) |
| Repeatability | ≤30% RSD (x < 0.5 mg/L) |
| Temperature Control Range | Ambient to 1100 °C |
| Temperature Stability | ±1 °C |
| Power Requirement | 1500 W |
| Carrier Gases | Industrial-grade N₂ and O₂ |
| Cooling Method | Intelligent Fan-based Air Cooling |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | KY-202 |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Analyte | Total Sulfur |
| Principle | Microcoulometric Titration (ASTM D3227, SH/T 0253, GB/T 11061.4, SH/T 0222) |
| Sample Forms | Liquid, Solid, Gas (with optional injectors) |
| Detection Range | 0.2 mg/L – 10,000 mg/L (S) |
| LOD | 0.2 mg/L (S) |
| Repeatability | As per SH/T 0253 specifications (Cv ≤ 3% for [S] > 10 mg/L |
| Temperature Control | Ambient to 1100 °C, ±1 °C |
| Power | 1500 W |
| Carrier Gases | Technical-grade O₂ and N₂ |
| Cooling | Air-cooled pyrolysis furnace with auto-controlled fan |
| Brand | Kyoyuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | KY-300 |
| Price | USD 9,500 (FOB Jiangsu) |
| Measurement Principle | Coulometric Titration |
| Carbon Range | 1–99 wt% |
| Hydrogen Range | 0.1–99.9 wt% |
| Carbon Repeatability | ≤0.50% RSD |
| Hydrogen Repeatability | ≤0.15% RSD |
| Combustion Furnace Temp Range | Ambient to 1000 °C |
| Conversion Furnace Temp Range | Ambient to 500 °C |
| Temperature Control Accuracy | ±10 °C of setpoint |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 3200 W |
| Dimensions (L×W×H) | 780 × 430 × 310 mm |
| Cooling | External electrolytic cell cooling system required |