Industry-specific Instruments
Filter
Showing 2851–2880 of 6535 results
| Brand | Kyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | KY-200 |
| Price | Upon Request |
| Principle | Microcoulometric Titration (Electrolytic Iodine Generation) |
| Sample Forms | Liquid, Solid, Gas (with optional injectors) |
| Analyte | Total Sulfur (S) |
| Detection Range | 0.1–10,000 mg/L |
| LOD | 0.1 mg/L (as S) |
| Repeatability | CV ≤3% (for x >10 mg/L), ±0.1 mg/L (0.5–1.0 mg/L), CV ≤8% (1.0–10 mg/L), <30% (x <0.5 mg/L) |
| Temperature Control | Ambient to 1100 °C, ±1 °C |
| Power Consumption | 1500 W |
| Carrier Gases | Industrial-grade N₂ and O₂ |
| Cooling | Air-cooled furnace with auto-start/stop fan |
| Compliance Standards | SH/T 0253, GB/T 11061.4, SH/T 0222, GB/T 3208, SH/T 1147 |
| Brand | Kyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-200 |
| Detection Target | Total Sulfur |
| Measurement Principle | Microcoulometric Titration (ASTM D3227, SH/T 0253, GB/T 11061.4, SH/T 0222) |
| Sample Forms | Liquid, Solid, Gas (with optional injectors) |
| Detection Range | 0.2–10,000 mg/L S |
| LOD | 0.2 mg/L S |
| Precision | CV ≤ 3% (for x > 10 mg/L S) |
| Temperature Control | Ambient to 1100 °C, ±1 °C |
| Power Requirement | 1500 W |
| Carrier Gases | Industrial-grade N₂ and O₂ |
| Cooling Method | Intelligent Fan-based Air Cooling |
| Compliance Standards | SH/T 0253, GB/T 11061.4, SH/T 0222 |
| Brand | Kyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KY-3000SA |
| Detection Principle | UV Fluorescence |
| Portability | Benchtop (Non-portable) |
| Analyte | Total Sulfur |
| Measurement Range | 0.2 mg/L to 5000 ppm to % (w/w) |
| Analysis Time | <10 min |
| Detection Limit | 0.2 mg/L |
| Accuracy | ±0.1 mg/L for 0.2 mg/L ≤ X < 1.0 mg/L |
| Repeatability | CV ≤10% (1.0–100 mg/L), CV ≤5% (100–10,000 mg/L) |
| Temperature Control Range | Ambient to 1300 °C |
| Temperature Stability | ±3 °C |
| Power Consumption | 2 kW |
| Gas Requirements | High-purity O₂ (≥99.98%), High-purity Ar (≥99.98%) |
| Data Acquisition | 24-bit ADC, USB Interface |
| PMT Voltage | Adjustable |
| Calibration Modes | Single-point or multi-point calibration |
| Compliance Standards | SH/T 0689, ASTM D5453, GB/T 34100–2017 |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | KY-4As |
| Pricing | Available Upon Request |
| Measurement Principle | Microcoulometric Titration |
| Sample Type | Liquid |
| Detection Method | Hydride Generation–Microcoulometric Detection |
| Bias Voltage Range | 0–500 mV |
| Measurement Range | 1 × 10⁻⁹ % (1 ppb) to % level |
| Input Impedance | ≥10⁶ Ω |
| Output Voltage | ±24 V |
| Baseline Drift | ≤5 µV / 20 min |
| Temperature Control Accuracy | ±0.5% or ±5 °C (whichever is greater) |
| Analysis Time (instrumental only) | 5–10 min |
| Detection Limit | 1 ppb As |
| Operating Humidity | <80% RH |
| Operating Temperature | 10–40 °C |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | KY-4Br |
| Pricing | Upon Request |
| Measurement Principle | Coulometric Titration (Microcoulometry) |
| Sample Type | Liquid Hydrocarbons |
| Method Standard Compliance | SH/T 0630–1996, SH/T 1551–2018, GB/T 11136–1989(2004), SH/T 1767–2008(2015), GB/T 1815–1997, ASTM D1492 |
| Detection Range | Bromine Number: 0–300 g Br/100 g oil |
| Bromine Index | 1–1000 mg Br/100 g oil |
| Resolution | 0.01 mg Br |
| Detection Limit | 0.1 mg Br |
| Accuracy | ±5% (for bromine index ≥1 mg Br/100 g oil) |
| Bias Voltage Range | 0–500 mV |
| Endpoint Detection | Dual Platinum Electrode Potentiometric Detection |
| Electrolytic Cell Volume | 150 mL |
| Stirring Mechanism | Magnetic Stirrer |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 20 W |
| Net Weight | ~1.6 kg |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | KY-200 |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Analyte Scope | Total Sulfur, Total Nitrogen, and Halides (Cl⁻, Br⁻, I⁻) |
| Measurement Principle | Microcoulometric Titration per ASTM D5808 & GB/T 18612 |
| Detection Range (Cl) | 0.05–10,000 mg/L |
| LOD (Cl) | 0.05 mg/L |
| Repeatability | ≤10% (≤1 mg/L), ≤8% (1–10 mg/L), ≤3% (>10 mg/L) |
| Sensitivity | 0.05 mg NaCl/L |
| Furnace Temp Control | Ambient to 1000 °C ±1 °C |
| Cooling Method | Intelligent Fan-Cooled |
| Analysis Time | ~3 min/sample (excluding sample prep) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | KY-202 |
| Price Range | USD 4,200 – 7,000 (FOB China) |
| Analyte | Total Sulfur |
| Measurement Principle | Microcoulometric Titration (ASTM D3227, SH/T 0222–1992, GB/T 11061–1997, SH/T 0253–1992) |
| Sample Types | Liquid & Gaseous Hydrocarbons (with optional gas/liquid autosamplers) |
| Detection Range | 0.2–10,000 mg/L S |
| LOD | 0.2 mg/L S |
| Repeatability | ≤30% RSD (at ≤1.0 mg/L), ≤10% RSD (1.0–100 mg/L), ≤5% RSD (>100 mg/L) |
| Furnace Temp Control | Ambient to 1100 °C, ±1 °C |
| Carrier Gases | Industrial-grade O₂ and N₂ |
| Cooling | Fan-cooled裂解炉 (Auto-start/stop) |
| Power | 1500 W |
| Brand | Kyuyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | KY-3000NS |
| Detection Principle | UV Fluorescence (S), Chemiluminescence (N) |
| Portability | Benchtop (Non-portable) |
| Analyte Types | Total Sulfur and Total Nitrogen |
| Measurement Range | 0.1–100,000 mg/L |
| Analysis Time | <10 min |
| LOD | 0.1 mg/L (N), 0.2 mg/L (S) |
| Accuracy | ±0.2 mg/L (at ≤1.0 mg/L) |
| Repeatability | CV ≤10% (1–100 mg/L), CV ≤5% (100–10,000 mg/L) |
| Furnace Temperature Range | Ambient to 1300 °C |
| Temperature Control Precision | ±1 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, 1500 W |
| Gas Requirements | Argon ≥99.98%, Oxygen ≥99.98% |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | KY-3000S |
| Price Range | USD 7,000–14,000 (FOB China) |
| Analyte | Total Sulfur |
| Detection Principle | UV Fluorescence (ASTM D5453 / SH/T 0689 / GB/T 34100-2017) |
| Sample Forms | Liquid, Solid, Gas (with optional injectors) |
| Detection Range | 0.2 mg/L to 5000 ppm (up to % level) |
| LOD | 0.2 mg/L (as S) |
| Repeatability | ≤±0.1 mg/L (0.2–1.0 mg/L) |
| Furnace Temp Control | RT–1300 °C, ±3 °C |
| Gas Requirements | ≥99.98% O₂ and ≥99.98% Ar |
| Data Acquisition | 24-bit USB interface, signal resolution <1 µV |
| PMT HV Adjustment | Continuously variable |
| Calibration | Single- or multi-point standard curve |
| Software Compatibility | Windows 10/11, macOS (via Wine), Linux (via VM) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | KY-4 |
| Price Range | USD 2,800 – 4,300 (FOB Jiangsu) |
| Measurement Principle | Coulometric Titration (Silver Nitrate Electrolysis) |
| Sample Type | Liquid |
| Method Standard Compliance | SY/T 0536–2008, GB/T 6532–2012, ASTM D3230–2013 |
| Bias Voltage Range | 0–500 mV (adjustable) |
| Salt Content Range | 0.2–10,000 mg/L as NaCl |
| Chloride Ion Range | 0.1 ppm to full percentage (w/w) |
| Accuracy | ±3% RSD |
| Sample Mass | 1.0 g ± 0.2 g |
| Power Consumption | 50 W |
| Operating Environment | 10–40 °C, ≤80% RH, low-EMI environment |
| Electrolytic Cell Design | Sintered Glass Frit (No Ion-Exchange Membrane) |
| Data Output | Real-time status monitoring, parameter logging, and result printing via integrated microcomputer interface |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | KY-403 |
| Pricing | Available Upon Request |
| Brand | Kyuyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | KY-403B |
| Pricing | Available Upon Request |
| Sample Type | Liquid |
| Sulfur Alcohol (Mercaptan Sulfur) Measurement Range | 0.0001–0.01 % (m/m) |
| Titration Method | Potentiometric Titration |
| Burette Volume | 10 mL |
| Minimum Dispensing Volume | 0.01 mL |
| Potential Measurement Range | −1999.5 to +1999.5 mV |
| Burette Accuracy | ±0.1 % of Full Scale |
| Electronic Unit Basic Error | ±0.1 % of full scale reading + 0.5 mV |
| Relative Error | ≤5 % |
| Input Impedance | ≥1 × 10¹² Ω |
| Compliance Standard | JJG 814–2015 Verification Regulation for Automated Potentiometric Titrators |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | KY-403B |
| Pricing | Available Upon Request |
| Sample Type | Liquid |
| Sulfur Alcohol (Mercaptan Sulfur) Measurement Range | 0.0001–0.01 % (m/m) |
| Titration Method | Potentiometric Titration |
| Burette Capacity | 10 mL |
| Minimum Dispensed Volume | 0.01 mL |
| Potential Measurement Range | ±1999.5 mV |
| Burette Accuracy | ±0.1 % F.S. |
| Electronic Unit Basic Error | ±0.1 % of full scale + 0.5 mV |
| Relative Error | ≤5 % |
| Input Impedance | ≥1 × 10¹² Ω |
| Compliance | JJG 814–2015 Verification Regulation for Automatic Potentiometric Titrators |
| Brand | Kyuyuan Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | KY-4As |
| Pricing | Available Upon Request |
| Measurement Principle | Microcoulometric Titration |
| Sample Form | Liquid |
| Detection Method | Hydride Generation–Microcoulometric Detection |
| Bias Voltage Range | 0–500 mV |
| Measurement Range | 1 × 10⁻⁹ % (1 ppb) to % (w/w) |
| Input Impedance | ≥10⁶ Ω |
| Output Voltage | ±24 V |
| Baseline Drift | ≤5 µV / 20 min |
| Temperature Control Accuracy | ±0.5% or ±5 °C (whichever is greater) |
| Analysis Time (excluding sample prep) | 5–10 min |
| Sensitivity | 1 ppb (as As) |
| Operating Humidity | <80% RH |
| Operating Temperature | 10–40 °C |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | KY-4D |
| Price Range | USD 4,200–7,000 |
| Detection Principle | Potentiometric Titration |
| Portability | Benchtop (Non-portable) |
| Analyte | Alkaline Nitrogen in Petroleum Products |
| Measurement Range | ≥3 µg/g |
| Analysis Time | <10 min |
| Detection Limit | ±0.1% F.S. |
| Indication Error | 0.1% F.S. ± 0.5 mV |
| Titration Resolution | 0.01 mL |
| Electrode Potential Range | 0 to ±1999.5 mV |
| Burette Accuracy | ±0.1% F.S. |
| Electronic Unit Basic Error | 0.1% of full scale ± 0.5 mV |
| Relative Error | ≤5% |
| Compliance Standard | SH/T 0162–1992 |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | KY-4S |
| Pricing | Available Upon Request |
| Sample Type | Liquid |
| Analytical Method | Potentiometric Titration |
| Detection Limit | ≥3 µg/g |
| Minimum Titrant Dispense Volume | 0.01 mL |
| Electrode Potential Range | 0 to ±1999.5 mV |
| Burette Accuracy | ±0.1% F.S. |
| Electronic Unit Basic Error | ±0.1% of full scale + 0.5 mV |
| Relative Standard Deviation | ≤5% |
| Compliance Standard | GB/T 1792–1988 “Determination of Mercaptan Sulfur in Distillate Fuels” |
| (Manufacturer | LOOP |
|---|---|
| Model | CF121 |
| Type | Benchtop Carbonation & Filling System for R&D) |
| [Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | CF121 |
| Quotation | Available Upon Request |
| Capacity | 25 L/h |
| CO₂ Saturation Range | 5.0–10.0 g/L (adjustable in 0.5 g/L increments) |
| Cooling Temperature | 6 °C |
| Operating Pressure | 20–100 PSI |
| Power Supply | 220 V, 50 Hz, 2.5 kW |
| Dimensions | 520 × 580 × 950 mm |
| Weight | 90 kg |
| Bottle Compatibility | Up to 1.5 L, PET/glass, standard neck profiles |
| CO₂ Purge & Pre-pressurization | Yes |
| Fill Method | Continuous, pressure-assisted pre-fill saturation |
| Refrigeration | Integrated single-stage chiller |
| Control | Digital PID-based CO₂ dosing and pressure regulation] |
| Brand | LABC |
|---|---|
| Origin | Germany |
| Model | DN120 |
| Cell Volume | ~200 mL |
| Single-Side Contact Area | ~1.00 dm² |
| Double-Side Contact Area | ~2.00 dm² |
| Construction | Stainless Steel Body |
| Cap Thread | GL14 |
| Cap Material | PBT Housing with PTFE/Silicone Seal |
| Sealing Elements | Two FEP/Silicone O-Rings (Top & Bottom Grooves) |
| Compliance | EU Regulation No. 10/2011, EN 13130, ISO 21768, GB 5009.156–2016 |
| Brand | LABC |
|---|---|
| Origin | Germany |
| Model | Sieg-Mi-Flex A |
| Material | 316L stainless steel (body & center ring), FDA-compliant FKM O-rings |
| Temperature Range | −15 °C to +180 °C |
| Compliance | EN 1186-1 to -14, ISO 17790, GB 5009.156–2016, Regulation (EU) No 10/2011 |
| Center Ring Options | DN30 to DN120 (7 standard sizes) |
| Surface Area (single-sided) | 0.05–2.00 dm² |
| Approx. Volume Range | 10–200 mL |
| Sealing | Dual FKM O-ring compression seal with torque-controlled clamping mechanism |
| Configurations | Single-sided exposure, double-sided exposure, and inverted orientation support |
| Brand | LABC |
|---|---|
| Origin | Germany |
| Model | Sieg-Mi-Flex B |
| Construction Material | Chemically inert polymer composite (PEEK, PTFE, and fluorinated ethylene propylene—FEP) |
| Compliance | EN 1186-1 to -14, ISO 10993-12, GB 5009.156–2016 |
| Sealing | Dual O-ring (FEP-coated silicone), validated for static and dynamic migration testing up to 100 °C |
| Sample Exposure Configuration | Single-sided or double-sided contact mode |
| Volume Range | 10–200 mL |
| Surface Area Range | 0.05–2.0 dm² (single-sided) |
| Temperature Stability | ±0.5 °C over 24 h at 40 °C, 70 °C, and 100 °C |
| Pressure Rating | Ambient to 0.2 bar (non-pressurized design |
| Brand | LABC |
|---|---|
| Origin | Germany |
| Model | Sieg-Mi-Flex C |
| Material | Chemically Resistant Optical-Grade Polymer (e.g., Fluorinated Acrylic or ETFE) |
| Temperature Range | −15 °C to +130 °C |
| Seal Type | Dual O-Ring Compression Seal (FKM or FFKM Elastomer) |
| Surface Contact Options | Single-Sided or Double-Sided Exposure |
| Compliance Standards | EN 1186 Parts 1–15, GB 5009.156–2016, FDA 21 CFR §170–189, ISO 10993-12 |
| Center Ring Configurations | 8 Standard DN30–DN120 Sizes with Defined Contact Area & Nominal Volume (10–200 mL) |
| Max. Pressure Rating | 0.3 bar (gauge) at 130 °C |
| Optical Clarity | >92% Transmittance (400–800 nm) |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | AST-20R |
| Pricing | Upon Request |
| Temperature Range | −73 °C to +200 °C |
| Thermal Ramp Rate | >50 °C/min |
| Vibration Platform | 30″ × 30″ × 40″ (76 cm × 76 cm × 101 cm) |
| Vibration Performance | Up to 50 g<sub>rms</sub> |
| Vibration Axes | Multi-axis electrodynamic shaker with programmable waveform synthesis |
| Monitoring Channels | Up to 16 vibration & 8 thermocouple inputs |
| Cooling Method | Mechanical refrigeration (compressor-based), optional LN₂ assist |
| Compliance | Designed to support ASTM E1820, IEC 61508, MIL-STD-810H, ISO 16750-4, and HALT/HASS protocol development per Telcordia GR-1089-CORE |
| Brand | LabCompanion |
|---|---|
| Model | LC-225A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Power Supply | AC 220V±10% / 50Hz or AC 380V±10% / 50Hz |
| Temperature Range | −40°C to +100°C (optional +150°C) |
| Temperature Uniformity | ≤2°C |
| Temperature Fluctuation | ±0.5°C (high-temp), ±1.0°C (low-temp) |
| Heating Rate | ≥2–3°C/min |
| Cooling Rate | ≤1°C/min |
| Internal Dimensions (W×H×D) | 500×600×500 mm |
| Insulation Material | High-Density Micronized Mineral Wool |
| Air Circulation | Stainless Steel Impeller, Single-Cycle Forced Convection |
| Safety Protections | Leakage Current Protection, Compressor High-Pressure & Overheat Protection, Motor Overcurrent & Thermal Cut-off, Fuse-Based Overload Protection, Audible Alarm |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TMJ-9729 |
| Light Irradiance at 340 nm | 0.5 ± 0.05 W/m² |
| Broadband Irradiance (300–800 nm) | 60 ± 6 W/m² |
| Lamp Type | 6500 W Water-Cooled Xenon Arc Lamp |
| Filter Options | Borosilicate (267–800 nm) or Soda-Lime (300–800 nm) |
| Chamber Interior | SUS#304 Stainless Steel, Matte Finish |
| Airflow Velocity in Test Chamber | 1.5 m/s |
| Sample Capacity | ≥76 Standard Specimens (38 Aluminum Test Racks × 2 Layers) |
| Black Panel Temperature Range | 0.0–120.0 °C |
| UV/VIS Radiometer | ELSEC UV/VIS Transducer (290–400 nm, 0–200 W/m²) |
| Brand | LabCompanion |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ZD-300 |
| Price | Upon Request |
| Speed Range | 150–300 rpm |
| Amplitude (Peak-to-Peak) | 25.4 mm (1 in) ±15% |
| Load Capacity | 136 kg (300 lb) |
| Test Table Dimensions (Standard) | 1.2 m × 1.0 m |
| Optional Table Sizes | Up to 3.0 m × 3.0 m (Customizable) |
| Timer Resolution | 0.1 s |
| Start Delay Accuracy | ±0.15 s |
| Motor Power | 2.24 kW (3 HP) |
| Drive System | DC speed control or AC variable-frequency drive |
| Supply Voltage | 220 V, 50/60 Hz |
| Compliance | ASTM D999, ASTM D3580, ISO 2247, ISTA 1A/2A/3A |
| Brand | Labman |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AutoResist Pro |
| Pricing | Available Upon Request |
| Brand | Labman |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Basic Coating Dispensing System |
| Pricing | Upon Request |
| Brand | Labman |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HTF-1000 |
| Pricing | Available Upon Request |
| Brand | KPM-CHOPIN |
|---|---|
| Origin | USA |
| Model | LabMill |
| Compliance | ISO 27971:2008 |
| Patent | FR 0905572 / US 9,067,210 |
| Feed Capacity | 50 g – 2,000 g per run |
| Roller Configuration | 2-break, 1-scratch, 2-heart passages |
| Feed Control | Integrated precision balance with constant-rate gravimetric feeding |
| Roller Adjustment | Eccentric shaft-mounted rollers with user-defined gap calibration |
| Sieving System | Multi-stage cascade sieving (defined mesh sizes per passage) |
| Construction | Industrial-grade stainless steel and hardened alloy components |
| Operating Principle | Simulated industrial roller milling using sequential break–scratch–heart grinding and fractionated sifting |
| Brand | Labonce |
|---|---|
| Model | Labonce-1000CT |
| Category | Pharmaceutical Stability Testing Chamber |
| Internal Volume | 1000 L |
| Internal Dimensions (W×D×H) | 1400×510×1400 mm |
| External Dimensions (W×D×H) | 1620×930×1980 mm |
| Temperature Range | 0–85 °C |
| Temperature Uniformity | ≤2.0 °C |
| Temperature Fluctuation | <±0.5 °C |
| Temperature Deviation | <±1.0 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 3.0 kW |
| Standard Shelves | 4 pcs (adjustable, total 8 positions) |
| Refrigeration System | Imported inverter compressor |
| Control System | Programmable color touchscreen controller with 3-tier user permissions and audit trail capability |
| Data Storage | Internal electronic logging + USB export |
| Safety | Independent over-temperature protection circuit |
| Door Structure | Dual-door design — outer insulated solid door + inner tempered glass door |
| Construction | Exterior — powder-coated steel |
| Compliance Reference | GB/T 10586–2006 “Technical Specifications for Damp Heat Test Chambers” |