| Brand | SITA |
|---|---|
| Origin | Germany |
| Model | Clean Line CI |
| Enclosure | Anodized Aluminum IP51 |
| Interface | RS-485 / Bus or PTP |
| Measurement Principle | UV-Induced Fluorescence (Excitation: 365 nm, Emission Detection: 460 nm) |
| Measurement Spot Diameter | 1 mm |
| Working Distance | 4 mm |
| Cleanliness Scale | 0–100% (calibrated to reference “100% clean” standard) |
| Fluorescence Intensity Range | 0–1,000 RFU (SITA Fluorescence Standard N1 = 100 RFU) |
| Resolution | 0.1% (cleanliness), 0.1 RFU (fluorescence) |
| Max. Measurement Rate | 100 points/s (100 Hz) |
| Max. Surface Speed | 10 m/s |
| Dimensions (W×H×D) | 50 × 95 × 30 mm |
| Weight | 200 g |
| Operating Temperature | 10–50 °C |
| Relative Humidity | ≤70% RH |
| Compliance | Designed for industrial integration in ISO/TS 16949, IATF 16949, and ISO 14644 cleanroom-adjacent environments |
| Scan Modes | Linear (single/multi-sensor), Surface (X-Y stage), Freeform (3D coordinate-driven) |
| Brand | SITA |
|---|---|
| Origin | Germany |
| Model | SurfaSpector |
| Instrument Type | Portable Dynamic Contact Angle Analyzer |
| Contact Angle Range | 5°–175° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Size | 5 × 5 mm |
| Optical Magnification | 100× |
| Surface/Interfacial Tension Range | 0–100 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Measurement Method | Optical Sessile Drop with Shadow Projection & Perspective-Corrected Image Analysis |
| Minimum Sample Area | 5 × 5 mm |
| Test Liquid | Ultra-Pure Water (5 mL internal reservoir, ~5,000 measurements per fill) |
| Power | Rechargeable Battery (≥6 h continuous operation) |
| Interface | USB (data transfer & charging) |
| Display | 5" TFT Touchscreen (800 × 480 px) |
| Brand | SITA |
|---|---|
| Origin | Germany |
| Model | FoamTester R-2000 |
| Air Intake Control | Patented Rotor System |
| Foam Volume Measurement Range | 0–2000 mL |
| Resolution | 1 mL |
| Agitation Time | 10–600 s (1 s increments) |
| Rotor Speed | 50–2000 rpm |
| Temperature Control | 0–80 °C (via liquid thermostat, ±1 K accuracy) |
| Sample Volume | 250–1500 mL |
| Sample Reservoir Capacity | 2 L |
| Automatic Rinse Cycle | Deionized or tap water |
| Power Supply | 100–240 V, 50–60 Hz |
| Power Consumption | 150 W |
| Ingress Protection | IP42 |
| Operating Ambient | 10–40 °C |
| Dimensions (W×D×H) | 280 × 400 × 700 mm |
| Weight | 18 kg |
| Brand | SITA |
|---|---|
| Origin | Germany |
| Model | CleanoSpector, Clean Line CI |
| Measurement Principle | UV-Induced Fluorescence (Confocal Detection) |
| Compliance | Designed for ISO 14644-1 cleanroom-adjacent process control, GLP-aligned data traceability, compatible with FDA 21 CFR Part 11–enabled software environments |
| Application Focus | Real-time quantification of organic residues (e.g., drawing lubricants, oils, surfactants) on steel wire substrates prior to electroplating |
| Brand | SITA |
|---|---|
| Origin | Germany |
| Model | t100 |
| Surface Tension Range | 10–100 mN/m |
| Resolution | 0.1 mN/m |
| Repeatability | ±0.5 mN/m |
| Bubble Lifetime Range | 15–100,000 ms |
| Temperature Control Range | −20 to +125 °C |
| Display | Color LCD |
| Power | USB 5 V/500 mA + Integrated Rechargeable Battery |
| Dimensions (Main Unit) | 200 × 140 × 60 mm |
| Weight | 1.87 kg |
| Brand | SITA |
|---|---|
| Origin | Germany |
| Model | Pro Line t15 / Science Line t100 |
| Measurement Range | 10–100 mN/m |
| Measurement Accuracy | ±0.1 mN/m |
| Repeatability | ±0.5 mN/m |
| Bubble Lifetime Control | 15 ms – 20 s (1 ms resolution) |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±0.1 °C (max deviation: 0.3 K) |
| Measurement Principle | Maximum Bubble Pressure Method (MBP) |
| Capillary Material | PEEK |
| Capillary Length | 68 mm |
| Sample Viscosity Limit | ≤2000 cP |
| Data Storage | 25 internal measurements |
| Interface | USB |
| Software | Included for real-time plotting, comparative analysis, and export (CSV/PDF) |
| Calibration | Automated with distilled water |
| Housing | Splash-proof, chemically resistant enclosure |
| Dimensions | 75 × 168 × 35 mm |
| Weight | 270 g |
| Brand | SITA |
|---|---|
| Origin | Germany |
| Model | DynoTester+ |
| Surface Tension Range | 15–100 mN/m |
| Accuracy | ±0.1 mN/m |
| Repeatability | ±0.5 mN/m |
| Bubble Time Adjustment | 15–15000 ms (3 preset values) |
| Max System Deviation | 5% |
| Temperature Measurement Range | 0–100 °C |
| Temp. Accuracy | ±0.3 K |
| Data Storage | 25 measurements (incl. surface tension, temperature, bubble time, timestamp) |
| Power | Rechargeable battery (≥10 h continuous use) + USB-powered operation |
| Interface | USB for data export and firmware update |
| Dimensions (W×H×D) | 75 × 168 × 35 mm |
| Sensor Length | 68 mm |
| Weight | 250 g |
| Enclosure | Splash-proof, acid- and alkali-resistant housing |
| Display | Backlit LCD |
| Keypad | 3 dedicated buttons for rapid bubble time selection |
| Brand | SITA |
|---|---|
| Origin | Germany |
| Model | CleanoSpector* |
| Measurement Principle | UV-Induced Fluorescence |
| Detection Target | Hydrocarbon-based contaminants (oils, greases, coolants, cleaning agents, fingerprints) |
| Output Unit | % Cleanliness (relative to calibrated clean reference surface) |
| Calibration | Auto-calibration on certified clean metal surface |
| Reference Surfaces | Steel, aluminum, copper, brass, gold, glass |
| Spot Diameter | 1 mm |
| Optimal Working Distance | 4 mm |
| Power Supply | Rechargeable Li-ion battery or AC adapter |
| Weight | 320 g (including probe and handle) |
| Compliance | Designed for ISO 8502-3, ASTM D7417, VDA 19.1, and GLP-aligned process validation |
| Brand | SITA |
|---|---|
| Origin | Germany |
| Model | CleanoSpector |
| Measurement Principle | UV-induced fluorescence (confocal detection) |
| Measurable Contaminants | Oils, greases, coolants, waxes, organic particulates |
| Output Unit | % cleanliness (0–100%, referenced to optically clean metal surface) |
| Calibration | Auto-calibration on clean reference metal surface (steel, copper, aluminum, gold, etc.) |
| Measurement Spot Distance | 4 mm |
| Power Supply | Rechargeable battery or AC adapter |
| Weight | 320 g (including sensor and handheld housing) |
| Environmental Robustness | Immune to ambient light, surface temperature variation, and surface roughness (within typical industrial metal finish ranges) |
| Compliance | Designed for ISO 8502-3, ASTM D7496, and VDA 19.1-aligned workflows |