BrandQ-Lab
OriginUSA
ModelCRH600-HSC
Salt Spray Deposition Rate0.5–3 mL/h·80 cm²
Temperature RangeAmbient to 70 °C
Chamber Capacity640 L
Humidity ControlYes (RH 10–95% RH, ramp rate programmable)
Optional FeaturesSpray Module, Nozzle Auto-Cleaning System, Preconditioned Air Humidification
ComplianceASTM B117, ISO 9227, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2027, GB/T 10125, ISO 16701, Prohesion™
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelCCT1100
Chamber TypeCyclic Corrosion Test Chamber
Core FunctionsSalt Spray / Dry / High-Humidity (100% RH) Cycling
ComplianceASTM B117, ASTM G85 Annex A5 (Prohesion), ISO 9227, ISO 11997, SAE J2334, GMW 14872, Ford CETP 00.00-L-467, VW PV1210
Control SystemIntegrated Q-FOG Microprocessor Controller with Real-Time Display and Programmable Cycle Sequencing
Chamber Volume1100 L (Standard Configuration)
ConstructionFiberglass-Reinforced Polymer (FRP) Cabinet with Corrosion-Resistant Interior
Humidity GenerationElectric Steam Generator
Salt Fog DeliveryCompressed-Air-Driven Atomization via Bubble Tower (except Prohesion mode)
Temperature ControlDual-Heater System (Chamber + Air Stream)
Viewing WindowPolycarbonate Side Window with Sealed Gasket
Data LoggingOnboard Event Timestamping (Start/Stop/Phase Transition), Optional USB Export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginUSA
ModelQ-FOG CCT
ComplianceASTM B117, ASTM G85, ISO 9227, BS 3900 F4/F9, DIN 50021
Temperature RangeAmbient to 50°C (operational control stability ±2°C)
Salt Solution DeliveryPneumatic air-assisted atomization with adjustable spray rate (typically 1.0–2.0 mL/80 cm²/h per ASTM B117)
Humidity Control100% RH capability (CCT-specific)
Chamber VolumeStandard 600 L (custom sizes available)
ConstructionFiberglass-reinforced polymer (FRP) chamber body with corrosion-resistant stainless steel hardware
Control System7-inch full-color touchscreen interface with programmable multi-step cycling logic
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQ-FOG CCT
Spray ModeContinuous Spray
Spray Rate1–5 L/h per 180 cm²
Nozzle Pressure0.7–1 kg/cm²
De-misting MethodAir-pressurized Exhaust
Temperature Range20–60 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginUSA
ModelSSP Series
ComplianceASTM B117, ASTM G85 (Prohesion™), ISO 9227, BS 3900-F4/F9, DIN 50021
Temperature RangeAmbient to 50 °C (operational range for salt fog and dry-off cycles)
Salt Solution DeliveryPrecision metered spray via pneumatic atomization
Chamber CapacityAvailable in multiple standard sizes (e.g., SSP-600, SSP-1200)
Control SystemTouchscreen PLC-based controller with cycle programming and real-time logging
Humidity ControlNot applicable (non-humidity-controlled
Salt Fog Deposition Rate1.0–2.0 mL/80 cm²/h (adjustable per ASTM B117)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginUSA
ModelCRH600-HSC / CRH1100-HSC
Salt Fog Deposition RateAdjustable via precision peristaltic pump and air pressure regulation
Temperature Range10°C to 70°C (operational), with rapid transition capability
Relative Humidity Control10% to 95% RH, ±2% RH accuracy (at 25°C)
Chamber Capacity640 L (CRH600-HSC) or 1103 L (CRH1100-HSC)
Spray Nozzle SystemSelf-cleaning, modular, DI-water compatible
Internal Solution Reservoir120 L, with level sensor and particulate filtration
ComplianceDesigned to meet GMW 14872, SAE J2334, ISO 11997, ASTM B117 (modified), VW PV1210, Ford CETP, Renault D17 2025, GB/T 24135–2009, and other automotive & industrial cyclic corrosion standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginUSA
ModelSSP1100
Salt Fog Deposition RateCompliant with ASTM B117 and ISO 9227 (adjustable via calibrated nozzles)
Temperature Range15–50 °C (operational stability ±1 °C)
Chamber Capacity1100 L (internal usable volume)
ComplianceASTM B117, ISO 9227, JIS Z2371, DIN 50021, GB/T 10587
Control SystemProgrammable touchscreen controller with audit trail capability
Humidity Control100% RH during wet/humid cycles (via steam generator)
Dry Cycle CapabilityDown to ≤30% RH (forced-air heated drying)
Prohesion™-Ready ConfigurationYes (dual-solution reservoirs, rapid transition logic)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQ-FOG SSP 1100
Spray ModeContinuous Atomization
Spray Rate1–5 L/h per 180 cm²
Nozzle Air Pressure0.7–1.0 kg/cm²
Fog Removal MethodCompressed-air-assisted雾 expulsion
Salt Fog Deposition Rate1–2 mL per 80 cm²·h
Temperature Range20–60 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginUSA
Manufacturer TypeAuthorized Distributor (not OEM)
Product OriginImported
ModelQ-FOG Series (e.g., Q-FOG CRH, Q-FOG SST, Q-FOG CCT)
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginUSA
ModelQ-FOG SSP600
Chamber Capacity640 L
Test ModesASTM B117 (Continuous Salt Fog), Prohesion™, and Custom Cyclic Corrosion Testing
Salt Solution DeliveryPrecision-controlled via variable-speed peristaltic pump and regulated compressed air
Temperature Range25–50 °C (operational range during salt fog cycle)
Salt Deposit RateAdjustable and compliant with ASTM B117 (1.0–2.0 mL/80 cm²/h)
Internal Reservoir120 L with integrated salt solution filter and low-level alarm
Sample Capacity160 test panels (75 mm × 150 mm)
ComplianceASTM B117, ASTM G85 (Annex A1–A5), ISO 9227, DIN 50021, BS EN ISO 9227, BS 3900-F4/F9
ControllerEmbedded microprocessor with full self-diagnostic suite, real-time status display, service alerts, and safety shutdown
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginUSA
ModelQ-FOG SSP
ComplianceASTM B117, ASTM G85, ISO 9227, BS 3900 F4/F9, DIN 50021
Cycle CapabilitiesSalt Spray, Prohesion®, Dry-off, Optional Humidity (CCT only)
Control SystemMicroprocessor-based dual-line LCD interface with programmable multi-step cycling
ConstructionFiberglass-reinforced polymer (FRP) chamber body, corrosion-resistant stainless steel hardware
Temperature RangeAmbient to 50 °C (spray/dry modes), up to 60 °C (optional humidified mode in CCT models)
Solution DeliveryPneumatic air-assisted atomization via adjustable nozzles, bubble-tower humidified air (except Prohesion®)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQ-FOG CCT-600
Chamber TypesSalt Spray, Dry-off, 100% RH Humidity (CCT only), and Ambient Hold
Control SystemMicroprocessor-based Programmable Controller with Self-Diagnostic Functions
Internal Solution Reservoir120 L with Integrated Saltwater Filter and Low-Level Alarm
雾 DispersionVariable-Speed Peristaltic Pump + Adjustable Air Pressure Regulator for Independent Control of Salt Spray Deposition Rate and Pattern
Temperature Transition SpeedRapid due to In-Chamber Heaters and High-Capacity Cooling/Drying Blower
Water RequirementDeionized or Distilled Water Only
Compliance SupportDesigned to meet ASTM B117, ASTM G85 Annexes (A1–A5), ISO 9227, ISO 11997, VDA 621-415, GMW 14872, Ford CETP 00.00-L-467, SAE J2334, and other cyclic corrosion test standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQ-FOG CRH
Spray ModeContinuous Spray
Spray Rate1–5 L/h per 180 cm²
Nozzle Pressure0.7–1 kg/cm²
Fog Removal MethodAir-Pressure Exhaust
Salt Fog Deposition Rate1–2 mL / 80 cm²·h
Temperature Range20–60 °C
Humidity ControlYes (via Air Pre-Conditioning System)
Optional Spray ModuleYes
Chamber Volumes640 L (CRH600), 1103 L (CRH1100)
ComplianceASTM B117, ISO 9227, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2025, GB/T 10125, ISO 16701
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelCRH 1100
Capacity1100 L (internal chamber volume)
Humidity Control Range0–100% RH (programmable, pulse-fogging assisted)
Temperature RangeAmbient +10°C to 60°C (typical operational range per ASTM G85 Annexes and ISO 16701)
Spray FunctionAdjustable flow rate, user-defined on/off timing, non-atomized liquid delivery
ComplianceFully supports GMW 14872, SAE J2334, ISO 16701, ASTM G85 Annexes 1/2/3/5, ISO 9227, IEC 60068-2-52, MIL-STD-810G, and other cyclic corrosion standards requiring precise RH control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQ-FOG SSP
ComplianceASTM B117, ASTM G85 (Prohesion), ISO 9227, BS 3900 F4/F9, DIN 50021
Chamber Volume640 L (SSP-600) or 1103 L (SSP-1100)
Temperature RangeAmbient to 50 °C (operational during salt fog cycle)
Salt Solution DeliveryPrecision metered pneumatic spray system with adjustable nozzle pressure and calibrated collection rate (1.0–2.0 mL/80 cm²/h per ASTM B117)
Control SystemTouchscreen programmable controller with multi-step cycling capability, real-time logging, and audit-trail-ready event history
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginUSA
ModelCCT-600
Chamber Capacity640 L
Cycle ModesSalt Spray, Dry, 100% RH Humidity, and Hold (Static)
ComplianceASTM B117, ISO 9227, ASTM G85 Annex A5 (Prohesion), SAE J2334, GMW 14872, Ford APGE, VW PV1210, Renault D17 2028
Water RequirementDeionized or purified water only
Internal Solution Reservoir120 L with level sensor and saltwater filter
ControllerIntegrated microprocessor-based system with self-diagnostic functions, service alerts, and safety shutdown
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQ-FOG CRH1100
Spray ModeContinuous Atomization
Fog Output1–5 L/h per 180 cm²
Nozzle Pressure0.7–1.0 kg/cm²
De-fogging MethodAir-pressurized Exhaust
Salt Fog Deposition Rate1–2 mL per 80 cm²·h
Temperature Range20–60 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginUSA
ModelQ-FOG CCT
Chamber Volume Options600 L / 1100 L
Temperature RangeAmbient to 50°C (typical operational range for cyclic corrosion testing)
Salt Solution DeliveryPneumatic atomization via saturated compressed air and adjustable peristaltic pump
Humidity Control100% RH via steam generator (CCT-specific)
Dry CycleForced-air convection heating with dual heater control (chamber + air heater)
ComplianceASTM B117, ISO 9227, ASTM G85 Annex A1–A5 (Prohesion), SAE J2334, GMW 14872, Ford CETP 00.00-L-467, VDA 621-415, DIN 50017, JIS Z2371
Software InterfaceQ-FOG Touchscreen Controller with programmable multi-step cyclic profiles, real-time monitoring, data logging, and audit-ready event history
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQ-FOG
Spray ModeContinuous Spray
Spray Rate1–5 L/h per 180 cm²
Nozzle Pressure0.7–1 kg/cm²
Fog Removal MethodAir-Compression Exhaust
Salt Fog Deposition Rate0.5–3 mL/h·80 cm²
Temperature RangeAmbient to 70 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginUSA
ModelQ-FOG CRH600
Spray ModeContinuous Atomization
Spray Rate1–5 L/h per 180 cm²
Nozzle Pressure0.7–1 kg/cm²
Fog Removal MethodAir-Driven Mechanical Exhaust
Salt Deposit Rate1–2 mL / 80 cm²·h
Temperature Range20–60 °C
Humidity ControlIntegrated Preconditioned Air System with Adjustable RH (20–95% RH, typical operating range)
Chamber Volume640 L
ComplianceASTM B117, ISO 9227, ISO 11997-1/2, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Volvo VCS 1027,000, Renault D17 2020, GB/T 10125
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginUSA
ModelSSP
Salt Fog Deposition Rate0.5–3 mL/h·80 cm²
Temperature RangeAmbient to 70°C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelCCT1100
Salt Spray Deposition Rate1.0–2.0 mL/80 cm²/h (ASTM B117 compliant range)
Temperature Range10–50 °C (Salt Fog), 25–70 °C (Dry), 25–60 °C (Humid)
Humidity Control95–100% RH (Condensation Humidity Mode)
Chamber Volume1100 L
Power Supply220–240 V, 50/60 Hz, Single Phase, Max 4.2 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-LAB
OriginUSA
ModelQ-LAB CCT600
Chamber Capacity640 L
Sample Capacity160 panels (75 mm × 150 mm)
Operating EnvironmentsSalt Fog / Dry / 100% RH Humidity / Ambient Hold
Temperature RangeAmbient to 50 °C (typical operational range for cyclic corrosion testing)
Salt Solution DeliveryPrecision-controlled via variable-speed peristaltic pump and regulated air pressure
Internal Solution Reservoir120 L with level sensor and filtration
ComplianceDesigned to support ASTM B117, ISO 9227, ASTM G85 Annexes (A1–A5), SAE J2334, GMW 14872, Ford CETP 00.00-L-467, VDA 621-415, and other internationally recognized cyclic corrosion standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelCRH600-HSC
Chamber Capacity640 L
Humidity Control Range10–95% RH (±2% RH typical accuracy)
Temperature RangeAmbient +10°C to 70°C
Salt Fog Deposition Rate1.0–2.0 mL/80 cm²/h (adjustable per ASTM B117)
Heating MethodForced-air convection (no steam generation)
ComplianceASTM B117, ISO 9227, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2025, GB/T 10125, ISO 16701, Prohesion™ protocol