| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH600-HSC |
| Salt Spray Deposition Rate | 0.5–3 mL/h·80 cm² |
| Temperature Range | Ambient to 70 °C |
| Chamber Capacity | 640 L |
| Humidity Control | Yes (RH 10–95% RH, ramp rate programmable) |
| Optional Features | Spray Module, Nozzle Auto-Cleaning System, Preconditioned Air Humidification |
| Compliance | ASTM B117, ISO 9227, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2027, GB/T 10125, ISO 16701, Prohesion™ |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CCT1100 |
| Chamber Type | Cyclic Corrosion Test Chamber |
| Core Functions | Salt Spray / Dry / High-Humidity (100% RH) Cycling |
| Compliance | ASTM B117, ASTM G85 Annex A5 (Prohesion), ISO 9227, ISO 11997, SAE J2334, GMW 14872, Ford CETP 00.00-L-467, VW PV1210 |
| Control System | Integrated Q-FOG Microprocessor Controller with Real-Time Display and Programmable Cycle Sequencing |
| Chamber Volume | 1100 L (Standard Configuration) |
| Construction | Fiberglass-Reinforced Polymer (FRP) Cabinet with Corrosion-Resistant Interior |
| Humidity Generation | Electric Steam Generator |
| Salt Fog Delivery | Compressed-Air-Driven Atomization via Bubble Tower (except Prohesion mode) |
| Temperature Control | Dual-Heater System (Chamber + Air Stream) |
| Viewing Window | Polycarbonate Side Window with Sealed Gasket |
| Data Logging | Onboard Event Timestamping (Start/Stop/Phase Transition), Optional USB Export |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT |
| Compliance | ASTM B117, ASTM G85, ISO 9227, BS 3900 F4/F9, DIN 50021 |
| Temperature Range | Ambient to 50°C (operational control stability ±2°C) |
| Salt Solution Delivery | Pneumatic air-assisted atomization with adjustable spray rate (typically 1.0–2.0 mL/80 cm²/h per ASTM B117) |
| Humidity Control | 100% RH capability (CCT-specific) |
| Chamber Volume | Standard 600 L (custom sizes available) |
| Construction | Fiberglass-reinforced polymer (FRP) chamber body with corrosion-resistant stainless steel hardware |
| Control System | 7-inch full-color touchscreen interface with programmable multi-step cycling logic |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT |
| Spray Mode | Continuous Spray |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| De-misting Method | Air-pressurized Exhaust |
| Temperature Range | 20–60 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | SSP Series |
| Compliance | ASTM B117, ASTM G85 (Prohesion™), ISO 9227, BS 3900-F4/F9, DIN 50021 |
| Temperature Range | Ambient to 50 °C (operational range for salt fog and dry-off cycles) |
| Salt Solution Delivery | Precision metered spray via pneumatic atomization |
| Chamber Capacity | Available in multiple standard sizes (e.g., SSP-600, SSP-1200) |
| Control System | Touchscreen PLC-based controller with cycle programming and real-time logging |
| Humidity Control | Not applicable (non-humidity-controlled |
| Salt Fog Deposition Rate | 1.0–2.0 mL/80 cm²/h (adjustable per ASTM B117) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | CRH600-HSC / CRH1100-HSC |
| Salt Fog Deposition Rate | Adjustable via precision peristaltic pump and air pressure regulation |
| Temperature Range | 10°C to 70°C (operational), with rapid transition capability |
| Relative Humidity Control | 10% to 95% RH, ±2% RH accuracy (at 25°C) |
| Chamber Capacity | 640 L (CRH600-HSC) or 1103 L (CRH1100-HSC) |
| Spray Nozzle System | Self-cleaning, modular, DI-water compatible |
| Internal Solution Reservoir | 120 L, with level sensor and particulate filtration |
| Compliance | Designed to meet GMW 14872, SAE J2334, ISO 11997, ASTM B117 (modified), VW PV1210, Ford CETP, Renault D17 2025, GB/T 24135–2009, and other automotive & industrial cyclic corrosion standards |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | SSP1100 |
| Salt Fog Deposition Rate | Compliant with ASTM B117 and ISO 9227 (adjustable via calibrated nozzles) |
| Temperature Range | 15–50 °C (operational stability ±1 °C) |
| Chamber Capacity | 1100 L (internal usable volume) |
| Compliance | ASTM B117, ISO 9227, JIS Z2371, DIN 50021, GB/T 10587 |
| Control System | Programmable touchscreen controller with audit trail capability |
| Humidity Control | 100% RH during wet/humid cycles (via steam generator) |
| Dry Cycle Capability | Down to ≤30% RH (forced-air heated drying) |
| Prohesion™-Ready Configuration | Yes (dual-solution reservoirs, rapid transition logic) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP 1100 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Air Pressure | 0.7–1.0 kg/cm² |
| Fog Removal Method | Compressed-air-assisted雾 expulsion |
| Salt Fog Deposition Rate | 1–2 mL per 80 cm²·h |
| Temperature Range | 20–60 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor (not OEM) |
| Product Origin | Imported |
| Model | Q-FOG Series (e.g., Q-FOG CRH, Q-FOG SST, Q-FOG CCT) |
| Pricing | Available Upon Request |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP600 |
| Chamber Capacity | 640 L |
| Test Modes | ASTM B117 (Continuous Salt Fog), Prohesion™, and Custom Cyclic Corrosion Testing |
| Salt Solution Delivery | Precision-controlled via variable-speed peristaltic pump and regulated compressed air |
| Temperature Range | 25–50 °C (operational range during salt fog cycle) |
| Salt Deposit Rate | Adjustable and compliant with ASTM B117 (1.0–2.0 mL/80 cm²/h) |
| Internal Reservoir | 120 L with integrated salt solution filter and low-level alarm |
| Sample Capacity | 160 test panels (75 mm × 150 mm) |
| Compliance | ASTM B117, ASTM G85 (Annex A1–A5), ISO 9227, DIN 50021, BS EN ISO 9227, BS 3900-F4/F9 |
| Controller | Embedded microprocessor with full self-diagnostic suite, real-time status display, service alerts, and safety shutdown |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP |
| Compliance | ASTM B117, ASTM G85, ISO 9227, BS 3900 F4/F9, DIN 50021 |
| Cycle Capabilities | Salt Spray, Prohesion®, Dry-off, Optional Humidity (CCT only) |
| Control System | Microprocessor-based dual-line LCD interface with programmable multi-step cycling |
| Construction | Fiberglass-reinforced polymer (FRP) chamber body, corrosion-resistant stainless steel hardware |
| Temperature Range | Ambient to 50 °C (spray/dry modes), up to 60 °C (optional humidified mode in CCT models) |
| Solution Delivery | Pneumatic air-assisted atomization via adjustable nozzles, bubble-tower humidified air (except Prohesion®) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT-600 |
| Chamber Types | Salt Spray, Dry-off, 100% RH Humidity (CCT only), and Ambient Hold |
| Control System | Microprocessor-based Programmable Controller with Self-Diagnostic Functions |
| Internal Solution Reservoir | 120 L with Integrated Saltwater Filter and Low-Level Alarm |
| 雾 Dispersion | Variable-Speed Peristaltic Pump + Adjustable Air Pressure Regulator for Independent Control of Salt Spray Deposition Rate and Pattern |
| Temperature Transition Speed | Rapid due to In-Chamber Heaters and High-Capacity Cooling/Drying Blower |
| Water Requirement | Deionized or Distilled Water Only |
| Compliance Support | Designed to meet ASTM B117, ASTM G85 Annexes (A1–A5), ISO 9227, ISO 11997, VDA 621-415, GMW 14872, Ford CETP 00.00-L-467, SAE J2334, and other cyclic corrosion test standards |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH |
| Spray Mode | Continuous Spray |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| Fog Removal Method | Air-Pressure Exhaust |
| Salt Fog Deposition Rate | 1–2 mL / 80 cm²·h |
| Temperature Range | 20–60 °C |
| Humidity Control | Yes (via Air Pre-Conditioning System) |
| Optional Spray Module | Yes |
| Chamber Volumes | 640 L (CRH600), 1103 L (CRH1100) |
| Compliance | ASTM B117, ISO 9227, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2025, GB/T 10125, ISO 16701 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH 1100 |
| Capacity | 1100 L (internal chamber volume) |
| Humidity Control Range | 0–100% RH (programmable, pulse-fogging assisted) |
| Temperature Range | Ambient +10°C to 60°C (typical operational range per ASTM G85 Annexes and ISO 16701) |
| Spray Function | Adjustable flow rate, user-defined on/off timing, non-atomized liquid delivery |
| Compliance | Fully supports GMW 14872, SAE J2334, ISO 16701, ASTM G85 Annexes 1/2/3/5, ISO 9227, IEC 60068-2-52, MIL-STD-810G, and other cyclic corrosion standards requiring precise RH control |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP |
| Compliance | ASTM B117, ASTM G85 (Prohesion), ISO 9227, BS 3900 F4/F9, DIN 50021 |
| Chamber Volume | 640 L (SSP-600) or 1103 L (SSP-1100) |
| Temperature Range | Ambient to 50 °C (operational during salt fog cycle) |
| Salt Solution Delivery | Precision metered pneumatic spray system with adjustable nozzle pressure and calibrated collection rate (1.0–2.0 mL/80 cm²/h per ASTM B117) |
| Control System | Touchscreen programmable controller with multi-step cycling capability, real-time logging, and audit-trail-ready event history |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | CCT-600 |
| Chamber Capacity | 640 L |
| Cycle Modes | Salt Spray, Dry, 100% RH Humidity, and Hold (Static) |
| Compliance | ASTM B117, ISO 9227, ASTM G85 Annex A5 (Prohesion), SAE J2334, GMW 14872, Ford APGE, VW PV1210, Renault D17 2028 |
| Water Requirement | Deionized or purified water only |
| Internal Solution Reservoir | 120 L with level sensor and saltwater filter |
| Controller | Integrated microprocessor-based system with self-diagnostic functions, service alerts, and safety shutdown |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH1100 |
| Spray Mode | Continuous Atomization |
| Fog Output | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1.0 kg/cm² |
| De-fogging Method | Air-pressurized Exhaust |
| Salt Fog Deposition Rate | 1–2 mL per 80 cm²·h |
| Temperature Range | 20–60 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT |
| Chamber Volume Options | 600 L / 1100 L |
| Temperature Range | Ambient to 50°C (typical operational range for cyclic corrosion testing) |
| Salt Solution Delivery | Pneumatic atomization via saturated compressed air and adjustable peristaltic pump |
| Humidity Control | 100% RH via steam generator (CCT-specific) |
| Dry Cycle | Forced-air convection heating with dual heater control (chamber + air heater) |
| Compliance | ASTM B117, ISO 9227, ASTM G85 Annex A1–A5 (Prohesion), SAE J2334, GMW 14872, Ford CETP 00.00-L-467, VDA 621-415, DIN 50017, JIS Z2371 |
| Software Interface | Q-FOG Touchscreen Controller with programmable multi-step cyclic profiles, real-time monitoring, data logging, and audit-ready event history |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG |
| Spray Mode | Continuous Spray |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| Fog Removal Method | Air-Compression Exhaust |
| Salt Fog Deposition Rate | 0.5–3 mL/h·80 cm² |
| Temperature Range | Ambient to 70 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH600 |
| Spray Mode | Continuous Atomization |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| Fog Removal Method | Air-Driven Mechanical Exhaust |
| Salt Deposit Rate | 1–2 mL / 80 cm²·h |
| Temperature Range | 20–60 °C |
| Humidity Control | Integrated Preconditioned Air System with Adjustable RH (20–95% RH, typical operating range) |
| Chamber Volume | 640 L |
| Compliance | ASTM B117, ISO 9227, ISO 11997-1/2, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Volvo VCS 1027,000, Renault D17 2020, GB/T 10125 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | SSP |
| Salt Fog Deposition Rate | 0.5–3 mL/h·80 cm² |
| Temperature Range | Ambient to 70°C |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CCT1100 |
| Salt Spray Deposition Rate | 1.0–2.0 mL/80 cm²/h (ASTM B117 compliant range) |
| Temperature Range | 10–50 °C (Salt Fog), 25–70 °C (Dry), 25–60 °C (Humid) |
| Humidity Control | 95–100% RH (Condensation Humidity Mode) |
| Chamber Volume | 1100 L |
| Power Supply | 220–240 V, 50/60 Hz, Single Phase, Max 4.2 kW |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB CCT600 |
| Chamber Capacity | 640 L |
| Sample Capacity | 160 panels (75 mm × 150 mm) |
| Operating Environments | Salt Fog / Dry / 100% RH Humidity / Ambient Hold |
| Temperature Range | Ambient to 50 °C (typical operational range for cyclic corrosion testing) |
| Salt Solution Delivery | Precision-controlled via variable-speed peristaltic pump and regulated air pressure |
| Internal Solution Reservoir | 120 L with level sensor and filtration |
| Compliance | Designed to support ASTM B117, ISO 9227, ASTM G85 Annexes (A1–A5), SAE J2334, GMW 14872, Ford CETP 00.00-L-467, VDA 621-415, and other internationally recognized cyclic corrosion standards |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH600-HSC |
| Chamber Capacity | 640 L |
| Humidity Control Range | 10–95% RH (±2% RH typical accuracy) |
| Temperature Range | Ambient +10°C to 70°C |
| Salt Fog Deposition Rate | 1.0–2.0 mL/80 cm²/h (adjustable per ASTM B117) |
| Heating Method | Forced-air convection (no steam generation) |
| Compliance | ASTM B117, ISO 9227, GMW 14872, SAE J2334, Ford CETP, VW PV1210, Renault D17 2025, GB/T 10125, ISO 16701, Prohesion™ protocol |