| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-MET Series |
| Type | Motorized Piezoelectric Translation Stage |
| Motion Axes | 2-Axis (XY), 3-Axis (XYZ) |
| Control | Closed-Loop |
| Positioning Resolution | XY: 0.15 nm, Z: 0.005 nm |
| Position Noise | XY: <4 pm/√Hz, Z: <400 fm/√Hz |
| Resonant Frequency | XY: 1.0–1.4 kHz, Z: 13.5 kHz |
| Travel Range | XY: 75 µm, Z: 5 µm |
| Max Load | 100 g (horizontal/vertical) |
| Body Material | Aluminum |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-MET10 & Nano-MET20 |
| Motion Range | 10 µm (Nano-MET10), 20 µm (Nano-MET20) |
| Positioning Resolution | 0.01 nm (Nano-MET10), 0.02 nm (Nano-MET20) |
| Resonant Frequency | 4.6 kHz |
| Max. Load (Horizontal/Vertical) | 100 g |
| Sensor Technology | Integrated PicoQ® Absolute Encoder |
| Controller | Nano-Drive® |
| Body Material | Aluminum |
| Control Mode | Closed-Loop |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-METZ |
| Motion Range | 5 µm |
| Positioning Resolution | 0.005 nm |
| Resonant Frequency | 14.5 kHz |
| Position Noise Floor | < 400 fm/√Hz |
| Max. Load (Horizontal/Vertical) | 0.1 kg |
| Body Material | Aluminum or Titanium |
| Controller | Nano-Drive® |
| Product Type | Closed-Loop Electric Nanopositioning Stage |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-MTA Series |
| Type | Piezoelectric Single- and Dual-Axis Tip/Tilt Actuator |
| Motion Axes | 1 or 2 |
| Max Scan Frequency | 400 Hz |
| Tip/Tilt Range (standard) | ±2 mrad per axis |
| Tip/Tilt Range (extended) | ±5 mrad per axis |
| Resolution (standard) | 4 nm rad⁻¹ |
| Resolution (extended) | 10 nm rad⁻¹ |
| Resonant Frequency (X-axis, loaded) | 3.2 kHz (±2 mrad) / 2.8 kHz (±5 mrad) |
| Resonant Frequency (Y-axis, loaded) | 1.25 kHz (±2 mrad) / 800 Hz (±5 mrad) |
| Step Response Time | ≤2 ms |
| Controller Compatibility | Nano-Drive® or Nano-Drive®85 |
| Closed-Loop Position Sensing | Integrated PicoQ® capacitive sensor |
| Mirror Mounting Diameter | 25 mm |
| Body Materials | Aluminum, Invar, or Titanium |
| Compliance | Designed for ISO/IEC 17025-aligned optical alignment workflows and GLP/GMP-relevant active optics integration |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-MZ |
| Motion Axis | Z-only |
| Drive Type | Piezoelectric |
| Control Mode | Closed-loop with integrated PicoQ® position sensing |
| Travel Range (Z) | 25 µm |
| Resolution | 0.05 nm |
| Resonant Frequency | 1100 Hz ±20% |
| Stiffness | 1.0 N/µm |
| Max Horizontal Load | 0.5 kg |
| Center Aperture Diameter | 0.25" |
| Height (Low Profile) | 0.8" |
| Body Material | Aluminum |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-OP Series |
| Motion Range | 30 μm / 65 μm / 100 μm |
| Resolution | 0.06 nm / 0.13 nm / 0.2 nm |
| Resonant Frequency | 4 kHz (±20%) / 2 kHz (under 100 g load) |
| Stiffness | 3.0 N/μm (±20%) |
| Angular Deviation (Roll/Pitch) | ≤1 μrad |
| Angular Deviation (Yaw) | ≤2 μrad |
| Max Load (Horizontal) | 1.0 kg |
| Max Load (Vertical) | 0.5 kg |
| Body Material | Aluminum / Invar / Titanium |
| Control | Closed-loop with PicoQ® absolute position sensing |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Nano-OPH |
| Drive Type | Motorized (Piezo-Based Direct Drive) |
| Motion Range Options | 30 μm / 50 μm / 100 μm |
| Closed-Loop Resolution | 0.06 nm (OPH30) / 0.1 nm (OPH50) / 0.2 nm (OPH100) |
| Resonant Frequency | 3.5 kHz (unloaded) ±20% |
| Stiffness | 3.0 N/μm ±20% |
| Angular Errors (Roll/Pitch) | ≤1 μrad |
| (Yaw) | ≤2 μrad |
| Max Horizontal Load | 1.0 kg |
| Max Vertical Load | 0.5 kg |
| Body Materials | Aluminum, Invar, or Titanium |
| Position Sensing | Integrated PicoQ® Absolute Piezoresistive Sensor |
| Controller | Nano-Drive® Platform |
| Aperture Diameter | 1.3 in (33 mm) |
| Stackable Architecture | Yes, for XYZ, XYθ, or custom multi-axis configurations |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-P Series |
| Motion Range | 15/35/70 μm |
| Resolution | 0.03/0.07/0.14 nm |
| Resonant Frequency | 2.5 kHz ±20% |
| Max Load | 0.2 kg |
| Construction | Invar and Titanium |
| Control | Closed-loop with integrated PicoQ® position sensors |
| Actuation | Piezoelectric |
| Guiding Principle | Monolithic flexure hinge (no Belleville springs) |
| Compliance | Designed for ISO/IEC 17025-aligned metrology environments, compatible with GLP/GMP data integrity requirements via Nano-Drive® controller audit trail logging |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-PDQ Series |
| Type | Motorized Nanopositioning Stage |
| Motion Axes | 2 or 3 (X/Y or X/Y/Z) |
| Travel Range | 50 μm or 75 μm per axis |
| Resolution | 0.1 nm (50 μm range) / 0.15 nm (75 μm range) |
| Resonant Frequency (X) | 2.5 kHz ±20% |
| Resonant Frequency (Y) | 1.5 kHz ±20% |
| Resonant Frequency (Z) | 1.0 kHz ±20% |
| Max Scanning Speed | 400 Hz |
| Stiffness | 3.0 N/μm |
| Angular Deviation (Roll/Pitch) | ≤1 μrad |
| Angular Deviation (Yaw) | ≤3 μrad |
| Max Horizontal Load | 0.5 kg |
| Max Vertical Load | 0.2 kg |
| Body Materials | Aluminum, Invar, or Titanium |
| Controller Compatibility | Nano-Drive®85 (HS models required for sub-2 ms step response) |
| Closed-Loop Technology | Integrated PicoQ® capacitive sensors |
| Aperture | Large central aperture optimized for optical path integration |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Nano-Route®3D |
| Product Type | Motorized Translation Stage Control Software |
| Compatibility | LabVIEW-Based, USB-Enabled Nano-Drive® Controllers |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-SPM200 |
| Motion Range (XY) | 200 µm |
| Resolution | 0.4 nm |
| Resonant Frequency (X/Y) | 300 Hz ±20% |
| Stiffness | 1.0 N/µm |
| Max Horizontal Load | 0.5 kg |
| Max Vertical Load | 0.2 kg |
| Body Material | Aluminum |
| Controller | Nano-Drive® |
| Drive Type | Piezoelectric, Flexure-Guided, Closed-Loop |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-SPMZ |
| Product Type | Motorized Translation Stage |
| Coarse Travel | 25 mm |
| Fine Travel | 30 µm |
| Coarse Step Size | 95 nm |
| Encoder Resolution (optional) | 20 nm |
| Nanopositioning Resolution | 0.06 nm |
| Resonant Frequency (unloaded) | 4 kHz ±20% |
| Stiffness | 3.0 N/µm ±20% |
| Max Horizontal Load | 1.0 kg |
| Max Vertical Load | 0.5 kg |
| Body Material | Aluminum |
| Controller | MicroDrive™ & Nano-Drive® |
| Interface | Bidirectional USB |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-SPMZ |
| Product Type | Motorized Translation Stage |
| Motion Range (Coarse) | 25 mm |
| Coarse Step Size | 95 nm |
| Encoder Resolution (Optional) | 20 nm |
| Nanopositioning Range | 30 µm |
| Nanopositioning Resolution | 0.06 nm |
| Resonant Frequency (Unloaded) | 4 kHz ±20% |
| Resonant Frequency (100 g Load) | 2 kHz ±20% |
| Stiffness | 3.0 N/µm ±20% |
| Max Horizontal Load | 1.0 kg |
| Max Vertical Load | 0.5 kg |
| Body Material | Aluminum |
| Controller | MicroDrive® + Nano-Drive® |
| Interface | Bidirectional USB |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Nano-T Series |
| Product Type | Motorized Nanopositioning Stage |
| Motion Axes | 2-Axis (XY) or 3-Axis (XYZ) |
| XY Travel Range | 100 μm / 200 μm |
| Z Travel Range | 20 μm / 50 μm |
| XY Resolution | 0.2 nm / 0.4 nm |
| Z Resolution | 0.04 nm / 0.1 nm |
| Closed-Loop Positioning Accuracy | Picometer-Level |
| Aperture | Large Central Opening for Optical Components |
| Control Architecture | Integrated PicoQ® Capacitive Sensing |
| Body Material | Aluminum or Invar |
| Max Horizontal Load | 0.5 kg |
| Max Vertical Load | 0.2 kg |
| Resonant Frequency (X) | 450 Hz / 400 Hz ±20% |
| Resonant Frequency (Y) | 250 Hz / 200 Hz ±20% |
| Resonant Frequency (Z) | 450 Hz / 350 Hz ±20% |
| Angular Deviation (Roll/Pitch) | ≤1 μrad |
| Angular Deviation (Yaw) | ≤3 μrad |
| Compatible Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-Theta |
| Product Type | Motorized Rotational Translation Stage |
| Motion Range | 2.0 mrad |
| Resolution | 4 nrad |
| Resonant Frequency (unloaded) | 2.0 kHz ±20% |
| Body Material | Aluminum or Invar |
| Control Architecture | Closed-loop with integrated PicoQ® position sensing |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-Theta/H |
| Product Type | Motorized Rotational Positioning Stage |
| Motion Range | ±2.5 mrad (total 5 mrad) |
| Resolution | 10 nrad |
| Repeatability | <20 nrad |
| Resonant Frequency (unloaded) | 300 Hz ±20% |
| Max Horizontal Load | 0.5 kg |
| Max Vertical Load | 0.2 kg |
| Body Materials | Aluminum, Invar, or Titanium |
| Control | Closed-loop via integrated PicoQ® capacitive sensors |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Nano-UHV100 |
| Product Type | Motorized Translation Stage |
| Motion Range (X/Y) | 100 µm × 100 µm |
| Resolution (XY) | 0.2 nm |
| Resonant Frequency (X) | 500 Hz ±20% |
| Resonant Frequency (Y) | 250 Hz ±20% |
| Stiffness | 1.0 N/µm |
| Angular Deviation (Roll/Pitch) | ≤1 µrad |
| Angular Deviation (Yaw) | ≤3 µrad |
| Max. Horizontal Load | 0.5 kg |
| Max. Vertical Load | 0.2 kg |
| Body Material | Invar or Titanium |
| Bakeout Temperature | 100 °C |
| Vacuum Compatibility | ≤10⁻¹⁰ Torr |
| Control | Closed-loop with PicoQ® position sensing |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | Canada |
| Model | Nano-UHV200 |
| Motion Range (X/Y/Z) | 200 µm × 200 µm × 200 µm |
| Resolution (XYZ) | 0.4 nm |
| Resonant Frequency (X) | 300 Hz ±20% |
| Resonant Frequency (Y) | 150 Hz ±20% |
| Resonant Frequency (Z) | 175 Hz ±20% |
| Stiffness | 2 N/µm |
| Angular Deviation (Roll/Pitch) | ≤1 µrad |
| Angular Deviation (Yaw) | ≤3 µrad |
| Max. Horizontal Load | 0.5 kg |
| Max. Vertical Load | 0.2 kg |
| Construction | Titanium & 316 Stainless Steel |
| UHV Compatibility | ≤1×10⁻¹⁰ Torr |
| Control | Closed-loop with PicoQ® absolute position sensing |
| Aperture | 2″ × 2″ center optical access |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-UHV50 |
| Motion Range (X/Y) | 50 µm × 50 µm |
| Resolution (XY) | 0.1 nm |
| Resonant Frequency (X) | 500 Hz ±20% |
| Resonant Frequency (Y) | 250 Hz ±20% |
| Stiffness | 0.5 N/µm |
| Angular Deviation (Roll/Pitch) | ≤1 µrad |
| Angular Deviation (Yaw) | ≤3 µrad |
| Max. Horizontal Load | 0.5 kg |
| Max. Vertical Load | 0.2 kg |
| Body Material | Invar or Titanium |
| Bakeout Temperature | 100 °C |
| UHV Compatibility | ≤1×10⁻¹⁰ Torr |
| Aperture | 25 mm (1 inch) |
| Position Sensing | PicoQ® closed-loop absolute sensing |
| Controller | Nano-Drive® |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-View® Series |
| Type | Motorized Translation Stage with Integrated Piezoelectric Nanopositioners |
| Travel (Micropositioning) | 25 mm per axis (X/Y) |
| Travel (Nanopositioning) | up to 300 µm per axis (X/Y/Z) |
| Micropositioner Step Size | 95 nm |
| Micropositioner Repeatability | 50 nm |
| Encoder Resolution (optional) | 20 nm |
| Nanopositioner Resolution | 0.2–0.6 nm (depending on range) |
| Closed-Loop Positioning Accuracy | Picometer-level (PicoQ® sensor technology) |
| Stiffness | 1.0 N/µm |
| Angular Deviation (Roll/Pitch) | ≤1 µrad |
| Angular Deviation (Yaw) | ≤3 µrad |
| Max Horizontal Load | 0.5 kg |
| Body Materials | Aluminum, Invar, or Titanium |
| Controllers | Nano-Drive® (nanopositioning) + Micro-Drive™ (micropositioning), USB interface |
| Software Compatibility | LabVIEW-ready, includes native motion control routines |
| Microscope Compatibility | Olympus IX/IX2, Nikon TE2000/Ti, Leica DMI, Zeiss Axiovert/Axio Observer, MCL RM21™ Platform |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-YT500 |
| Motion Axis | Single-axis (X) |
| Travel Range | 500 µm |
| Resolution | 1.0 nm |
| Resonant Frequency | 150 Hz ±20% |
| Stiffness | 0.8 N/µm |
| Max Horizontal Load | 0.5 kg |
| Max Vertical Load | 0.1 kg |
| Guiding Mechanism | Monolithic Flexure |
| Sensor Technology | PicoQ® Absolute Position Sensing |
| Control Architecture | Closed-loop with Nano-Drive® Controller |
| Body Material | Aluminum |
| Cycle Life | >1,000,000 full-range cycles |
| Aperture | Central rectangular optical pass-through |
| Orientation Independence | Yes |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Nano-Z Series |
| Product Type | Motorized Precision Translation Stage |
| Motion Axis | Single-Axis (Z) |
| Travel Range | 100 µm or 200 µm |
| Resolution | 0.2 nm (Nano-Z100) / 0.4 nm (Nano-Z200) |
| Resonant Frequency | 600 Hz ±20% (100 µm) / 450 Hz ±20% (200 µm) |
| Stiffness | 1.0 N/µm |
| Max Recommended Load (Horizontal) | 0.5 kg |
| Body Material | Aluminum or Invar |
| Control Mode | Closed-Loop with Integrated PicoQ® Position Sensing |
| Step Response Time | ≤4 ms (with Nano-Drive®85) |
| Aperture | 2.6" × 2.6" |
| Height | 0.8" |
| Software Compatibility | Nano-Control Suite, Third-Party LabVIEW/Python API Support |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-Z50HS |
| Motion Range | 50 µm |
| Resolution | 0.1 nm |
| Resonant Frequency | 1000 Hz ±20% |
| Stiffness | 1.0 N/µm |
| Max. Horizontal Load | 200 g |
| Body Material | Aluminum |
| Controller | Nano-Drive®85 |
| Control Mode | Closed-loop with PicoQ® position sensing |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Nano-ZL Series |
| Motion Range | 100 μm or 500 μm (Z-axis) |
| Position Resolution | 0.2 nm (Nano-ZL100) / 1 nm (Nano-ZL500) |
| Resonant Frequency | 250 Hz |
| Max. Horizontal Load | 0.5 kg |
| Body Material | Aluminum |
| Control | Closed-loop with integrated PicoQ® absolute position sensing |
| Software Compatibility | Nano-Drive® controller suite |
| Compliance | Designed for GLP-compliant optical microscopy workflows requiring traceable, reproducible Z-positioning |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Nano-ZS Series |
| Product Type | Motorized Precision Translation Stage |
| Motion Axis | Single-Axis (Z) |
| Travel Range | 100 μm or 200 μm |
| Resolution | 0.2 nm (Nano-ZS100) / 0.4 nm (Nano-ZS200) |
| Resonant Frequency | 450 Hz (100 μm) / 250 Hz (200 μm) |
| Stiffness | 1.0 N/μm |
| Max Recommended Load (Horizontal) | 0.5 kg |
| Body Material | Aluminum or Invar |
| Control Mode | Closed-Loop |
| Sensor Technology | PicoQ® Absolute Position Sensing |
| Controller Compatibility | Nano-Drive® and Nano-Drive®85 |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Nanopositioning and Micropositioning Accessories |
| Product Type | Motorized Translation Stage |
| Compatibility | Nano-BioS, Nano-LPS, Nano-Z500, Motorized MicroStage, Manual MicroStage-LT |
| Mounting Standards | RMS (Olympus/Zeiss/Leica), M25-0.75 (Nikon) |
| Rack Format | 2U (3.47 in height), Full-width & Half-width options |
| Control Interface | USB |
| Software | NanoControl & MicroControl (LabVIEW-based, Windows-compatible, free with USB-enabled systems) |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | OEM Nano-Drive® Series |
| Product Type | Motorized Translation Stage |
| Compliance | RoHS, CE (2004/108/EC, 2006/95/EC) |
| Power Input | 12 W @ 24 VDC |
| Amplifier Output Voltage Range | −20 V to +165 V |
| Continuous Power Output | 10 W |
| Max Continuous Drive Current | 50 mA |
| Feedback Sensor | PicoQ® capacitive position sensor |
| Control Loop | Proportional-Integral (PI) closed-loop servo |
| Analog Input | 0–10 V (configurable), BNC interface |
| Sensor Output | 0–10 V, BNC interface |
| USB Interface Option | 16-bit or 20-bit digital daughter board |
| Operating Temperature | 5–40 °C |
| Dimensions | 193.68 × 171.45 × 63.5 mm |
| Steady-State Power Consumption | <0.5 W |
| Input Impedance | 10 kΩ |
| Short-Circuit Protection | Yes |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | PZT1 / PZT2 / PZT3 / PZT4 |
| Actuator Type | Low-Voltage Multilayer Piezoelectric Actuator |
| Max. Displacement | 4.6–17.4 µm |
| Max. Driving Voltage | 150 VDC |
| Capacitance | 0.10–0.75 µF ±20% |
| Resonant Frequency | 69–276 kHz |
| Blocking Force | 200–850 N |
| Operating Temperature Range | −25 to +85 °C |
| Cross Section | 3.5×4.5 mm or 6.5×6.5 mm |
| Young’s Modulus | 4.4×10¹⁰ N/m² |
| Tensile Strength | 20–85 MPa |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | SPM-M Kit |
| Detection Noise | <0.15 nm RMS |
| Sample Size | <15 mm |
| XY Scan Range | 200 × 200 µm |
| Z Positioning | Nano-OP30 (closed-loop optional) |
| Controller | 3-Axis Nano-Drive® with PicoQ® sensors |
| Probe Options | Quartz tuning forks (5 included), Akiyama probe boards, tungsten tip etching compatibility |
| Software | AFMView™ with automated PLL control |
| Compliance | Designed for GLP/GMP-aligned research environments |
| Brand | MCL Think Nano |
|---|---|
| Origin | USA |
| Model | Tuning Forks |
| Center Frequency | 32.768 kHz |
| Oscillation Mode | Fundamental |
| Series Resistance (max.) | 30 kΩ |
| Tolerance (at 25 °C) | ±18 ppm |
| Operating Temperature Range | −10 °C to +60 °C |
| Frequency Stability Over Temperature | −0.038 ppm/°C |
| Drive Level | 10 µW |
| Shunt Capacitance (max.) | 1.7 pF |
| Motional Capacitance | 2.5 fF |
| Load Capacitance | 12.5 pF |
| Aging (max.) | ±3 ppm/year |
| Packaging | Pre-cleaned, “out-of-the-can” ready-to-mount configuration |
| Available Sizes | Medium and Large |