| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3116 |
| Acceleration Range | 0.02–200 m/s² RMS |
| Velocity Range | 0.02–200 mm/s RMS |
| Displacement Range | 2–2000 µm EQp-p |
| Accuracy | ±5% |
| Acceleration Frequency Range | 3 Hz–10 kHz |
| Velocity Frequency Range | 10 Hz–1 kHz (compliant with JIS B 0907-1989) |
| Displacement Frequency Range | 10–400 Hz |
| AC Output | 1 Vrms (full scale) |
| Headphone Output | Yes, with volume control |
| Communication Interface | RS-232C |
| Power Supply | Two AAA batteries or optional AC adapter |
| Dimensions | 145 mm (H) × 48 mm (W) × 23 mm (D) |
| Weight | Approx. 130 g |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 20–85% RH |
| Temperature Compensation | Integrated circuit for enhanced accuracy within 10–40 °C |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 20–85% RH |
| Temperature Compensation | Active compensation circuit optimized for 10–40 °C range |
| Sensor Element | Platinum-wire hot-wire anemometer |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1°C (temperature) |
| Operating Temperature | −20–70°C (probe), 5–40°C (main unit) |
| Operating Humidity | 20–85% RH |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature) |
| Display | Dual-parameter (wind speed + temperature), 4-level battery indicator, FAST/SLOW averaging (1 s / 5 s), unit toggle (m/s/°C ↔ fpm/°F), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm tip) × 205 mm |
| Cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 30 mm |
| Weight | ~180 g (incl. batteries) |
| Compliance | Designed for ISO 7726-compliant thermal comfort and HVAC airflow verification |
| Brand | Kanomax |
|---|---|
| Origin | China (Liaoning) |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.01–20.0 m/s |
| Velocity Resolution & Accuracy | ±5% of reading |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±1.0 °C |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Operating Ambient Temperature | −20 to +70 °C |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China (Distributed by Authorized KANOMAX Representative) |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.01–20.0 m/s |
| Velocity Accuracy | ±5% of reading |
| Velocity Resolution | ±5% of reading |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±1.0 °C |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Operating Ambient Temperature | −20 to +70 °C |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1°C (temperature) |
| Operating Temperature | −20–70°C (probe), 5–40°C (main unit) |
| Operating Humidity | 20–85% RH |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature) |
| Display | Dual-parameter (wind speed & temperature), 4-segment battery indicator, FAST/SLOW averaging (1 s / 5 s), unit toggle (m/s/°C ↔ fpm/°F), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm at tip) × 205 mm |
| cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 30 mm |
| Weight | ~180 g (including batteries) |
| Storage Temperature | −10–50°C |
| Accessories | Instruction manual, carrying case |
| Optional Accessories | Extension rod, replacement probe |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s) |
| Accuracy | ±5% of reading (m/s) |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±1.0 °C |
| Relative Humidity Operating Range | 20–85% RH |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Hot-Wire Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s) |
| Accuracy | ±5% of reading (wind speed) |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 20–85% RH |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Hot-Wire Anemometer |
| Velocity Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s) |
| Accuracy | ±5% of reading |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±1.0 °C |
| Operating Humidity | 20–85% RH |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Hot-Wire Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s) |
| Accuracy | ±5% of reading (wind speed) |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 20–85% RH |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Hot-Wire Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s) |
| Accuracy | ±5% of reading (wind speed) |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Hot-wire Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1°C (temperature) |
| Operating Temperature | −20 to +70°C (air), 0 to +50°C (probe), +5 to +40°C (main unit) |
| Operating Humidity | 20–85% RH |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature at 1 m/s) |
| Display | Dual-parameter (wind speed + temperature), selectable units (m/s/°C or fpm/°F), FAST/SLOW averaging (1 s / 5 s), battery level indicator (4-segment), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm at sensor tip) × 205 mm |
| cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 34 mm |
| Weight | ~180 g (including batteries) |
| Storage Temperature | −10 to +50°C |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Accuracy | ±5% of reading (wind speed), ±1°C (temperature) |
| Operating Temperature | −20–70°C (probe), 5–40°C (main unit) |
| Operating Humidity | 20–85% RH |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature) |
| Display | Dual-parameter (wind speed & temperature), 4-level battery indicator, FAST/SLOW averaging (1 s / 5 s), unit toggle (m/s/°C ↔ fpm/°F), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm at tip) × 205 mm |
| Cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 30 mm |
| Weight | ~180 g (including batteries) |
| Compliance | Designed for ISO/IEC 17025-aligned field verification and HVAC commissioning workflows |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s) |
| Temperature Range | −20 to +70 °C (air), 0 to +50 °C (probe), +5 to +40 °C (body) |
| Accuracy | ±5% of reading (wind speed), ±1 °C (temperature) |
| Response Time | <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature at 1 m/s) |
| Display | Dual-parameter (wind speed + air temperature), unit switchable (m/s/°C ↔ fpm/°F), FAST/SLOW averaging (1 s / 5 s), battery level indicator (4-level), hold function |
| Probe Dimensions | Ø6.1 mm (Ø10.6 mm with sheath) × 205 mm |
| cable | Ø3.3 mm × ~1.5 m |
| Main Unit Dimensions | 60 × 120 × 34 mm |
| Weight | ~180 g (including batteries) |
| Storage Temp. | −10 to +50 °C |
| Compliance | Designed for laboratory, HVAC, and industrial airflow verification per ISO 16813, ASHRAE Guideline 12, and JIS B 7555 standards |
| Brand | Kanomax |
|---|---|
| Model | 6036-0C / 6036-BC |
| Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–30.0 m/s |
| Accuracy | ±3% of reading (wind speed), ±0.5 °C (temperature), ±3% of reading (pressure, –0.00 to ±5 kPa) |
| Operating Temperature | –20 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| Data Storage Capacity | 1500 records |
| Interface | USB |
| Dimensions | 66 × 51 × 188 mm |
| Weight | 400 g (without batteries) |
| Probe | Flexible and telescopic |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6036 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–30.0 m/s |
| Accuracy | ±3% of reading + 0.03 m/s |
| Resolution | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0 %RH |
| Data Storage Capacity | 1500 sets |
| Probe | Articulating and telescoping |
| Output | Real-time USB data streaming with PC software support |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6036 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–30.0 m/s |
| Accuracy | ±3% of reading or ±0.03 m/s (whichever is greater) |
| Resolution | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0 %RH |
| Data Storage Capacity | 1,500 measurement sets |
| Output Interface | USB for PC connectivity |
| Probe | Flexible, telescoping stainless-steel probe with integrated temperature sensor |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–30.0 m/s |
| Resolution | ±2% of reading |
| Accuracy | ±3% of reading (wind speed), ±0.5°C (temperature), ±3% of reading (pressure, -0.00 to ±5 kPa) |
| Operating Temperature | -20 to +70°C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | 1500 sets |
| Interface | USB |
| Dimensions | 66 × 51 × 188 mm |
| Weight | 400 g (without batteries) |
| Probe | Flexible and telescopic |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6036-0C / 6036-BC |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.01–30.0 m/s |
| Velocity Accuracy | ±3% of reading |
| Velocity Resolution | ±2% of reading |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C |
| Pressure Range | −5.0 to +5.0 kPa |
| Pressure Accuracy | ±3% of reading |
| Humidity Range | 2.0–98.0 %RH |
| Data Storage Capacity | 1,500 records |
| Interface | USB |
| Dimensions | 66 × 51 × 188 mm |
| Weight | 400 g (battery excluded) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–30.0 m/s |
| Accuracy | ±3% of reading (wind speed), ±0.5 °C (temperature), ±3% of reading (pressure, ±5 kPa full scale) |
| Resolution | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | 1500 records |
| Interface | USB |
| Dimensions | 66 × 51 × 188 mm |
| Weight | 400 g (without batteries) |
| Compliance | Designed for ISO 14644-1/3 cleanroom qualification, GMP-compliant environmental monitoring workflows |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.01–30.0 m/s |
| Accuracy | ±3% of reading (m/s) |
| Resolution | ±2% of reading |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C |
| Pressure Range (6036-BC only) | −5.0 to +5.0 kPa |
| Pressure Accuracy | ±3% of reading |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage Capacity | 1,500 records |
| Interface | USB |
| Dimensions | 66 × 51 × 188 mm |
| Weight | 400 g (without batteries) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6036-0C / 6036P-BC |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.01–30.0 m/s |
| Accuracy | ±3% of reading (velocity), ±0.5 °C (temperature), ±3% of reading (pressure, 6036P-BC only) |
| Resolution | ±2% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 2.0–98.0% RH |
| Data Storage | 1500 measurement sets |
| Interface | USB |
| Dimensions | 66 × 51 × 188 mm |
| Weight | 400 g (without batteries) |
| Probe | Telescoping and flexible |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 6036-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–30.0 m/s |
| Accuracy | ±3% of reading |
| Operating Temperature | −20 to +70 °C |
| Operating Humidity | 0–100% RH |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±0.5 °C |
| Pressure Range | −5.0 to +5.0 kPa |
| Pressure Accuracy | ±3% of reading |
| Data Storage Capacity | 1500 records |
| Interface | USB |
| Dimensions | 66 × 51 × 188 mm |
| Weight | 400 g (without batteries) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6113 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.1–50.0 m/s |
| Velocity Resolution | 0.1 m/s |
| Velocity Accuracy | ±(3% of reading + 0.1) m/s |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1 °C |
| Pressure Range | –5 to +5 kPa |
| Pressure Accuracy | ±(3% of reading + 0.01) kPa |
| Humidity Operating Range | 5–80 %RH (for velocity measurement accuracy specification) |
| Communication Interface | RS-232C |
| Data Storage Capacity | 100 measurement sets |
| Statistical Functions | Max/Min/Average |
| Built-in Thermal Printer | Yes |
| Analog Output | 0–1 V |
| Power Supply | 6 × AA batteries |
| Dimensions | 210 × 120 × 133 mm |
| Weight | 1.0 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6113 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.1–50.0 m/s |
| Accuracy | ±(3% of reading + 0.1) m/s |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1 °C |
| Pressure Range | –5 to +5 kPa |
| Pressure Accuracy | ±(3% of reading + 0.01) kPa |
| Communication Interface | RS-232C |
| Data Storage Capacity | 100 sets |
| Analog Output | 0–1 V (optional) |
| Built-in Printer | Yes |
| Power Supply | 6 × AA batteries |
| Dimensions | 210 × 120 × 133 mm |
| Weight | 1.0 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6113 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.1–50.0 m/s |
| Resolution | 0.1 m/s |
| Accuracy | ±(3% of reading + 0.1) m/s |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1 °C |
| Pressure Range | −5 to +5 kPa |
| Pressure Accuracy | ±(3% of reading + 0.01) kPa |
| Humidity Operating Range | 5–80 %RH (for velocity measurement accuracy specification) |
| Communication Interface | RS-232C |
| Data Storage Capacity | 100 measurement sets |
| Statistical Functions | Max/Min/Average |
| Built-in Thermal Printer | Yes |
| Analog Output | 0–1 V |
| Power Supply | 6 × AA batteries |
| Dimensions | 210 × 120 × 133 mm |
| Weight | 1.0 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6113 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.1–50.0 m/s |
| Resolution | 0.1 m/s |
| Accuracy | ±(3% of reading + 0.1) m/s |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1 °C |
| Pressure Range | –5 to +5 kPa |
| Pressure Accuracy | ±(3% of reading + 0.01) kPa |
| Humidity Operating Range | 5–80 %RH (for velocity measurement accuracy specification) |
| Communication Interface | RS-232C |
| Data Storage Capacity | 100 measurement sets |
| Statistical Functions | Max/Min/Average |
| Built-in Thermal Printer | Yes |
| Analog Output | 0–1 V |
| Power Supply | 6 × AA batteries |
| Dimensions | 210 × 120 × 133 mm |
| Weight | 1.0 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6113 |
| Instrument Type | Thermal Anemometer |
| Velocity Range | 0.1–50.0 m/s |
| Accuracy | ±(3% of reading + 0.1) m/s |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1 °C |
| Pressure Range | −5 to +5 kPa |
| Pressure Accuracy | ±(3% of reading + 0.01) kPa |
| Communication Interface | RS-232C |
| Data Storage Capacity | 100 sets |
| Analog Output | 0–1 V (optional) |
| Built-in Thermal Printer | Yes |
| Power Supply | 6 × AA batteries |
| Dimensions | 210 × 120 × 133 mm |
| Weight | 1.0 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 6113 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.1 m/s |
| Measurement Range | 0.1–50.0 m/s |
| Accuracy | ±(3% of reading ± 0.1) m/s |
| Operating Temperature | 0–100 °C |
| Operating Humidity Range | 5–80 %RH (accuracy degrades outside this range) |
| Data Storage | 100 sets with min/max/avg statistics |
| Display | Large LCD |
| Interface | Standard RS-232C |
| Optional | Analog output module |