Other Environmental Monitoring Instruments
Filter
Showing 541–570 of 1326 results
| Brand | JRY |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Z06 |
| Price | ¥26,000 |
| Oscillation Frequency | 0–60 rpm (adjustable) |
| Timer Range | 0–99 h |
| Sample Bottle Capacity | 6 / 8 / 10 / 12 positions (2 L per bottle) |
| Temperature Range | Ambient to 65 °C |
| Temperature Control Accuracy | ±1 °C |
| Brand | JUDEEY |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VOC |
| Pricing | Available Upon Request |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZR-3900 |
| Pricing | Upon Request |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ZR-D05DT |
| Pricing | Upon Request |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ZR-D05G |
| Pricing | Available Upon Request |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ZR-D17BT |
| Pricing | Upon Request |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZR-F02G |
| Instrument Type | Portable Weather Station |
| Measured Parameters | Wind Speed, Wind Direction, Ambient Temperature, Relative Humidity, Atmospheric Pressure |
| Max. Permissible Error | Temperature ±0.5 °C, Humidity ±3 %RH |
| Resolution | 0.1 °C |
| Sensor Technology | Ultrasonic (Wind), Capacitive (Humidity), Thermistor (Temperature), Piezoresistive (Pressure) |
| Compliance | GB/T 35222–2017, HJ 972–2018, JJF 1716–2018 |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | ZR-H02 |
| Pricing | Available Upon Request |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JXWNP Series |
| Power Supply | 220 V / 380 V AC |
| Output Flow Rate | 1.0–60.0 m³/h |
| Control Options | Manual / LCD Panel / Keypad / Remote Controller / Mobile APP (4G/5G IoT) |
| Housing | Anodized Aluminum or 304 Stainless Steel |
| Operating Environment | ≤40 °C, ≤95% RH |
| Default Gas Source | Ambient Air (O₂/O₃ inlet optional) |
| Core Technology | Venturi-Enhanced Pressure Dissolution + Mechanical Shear Dispersion |
| Bubble Size Range | ~50 nm – 50 µm (size-distribution controllable and verifiable) |
| Detection Capability | Real-time underwater dynamic imaging of suspended microparticles, colloids, and microbubbles (≥1 µm resolution) |
| Brand | Kanomax |
|---|---|
| Origin | China (Liaoning) |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Power Supply | AC 100–240 V / DC 12–24 V |
| Dimensions (Main Unit) | 220 × 130 × 40 mm |
| Weight (Main Unit) | 0.6 kg |
| Channel Capacity | 12 simultaneous probes |
| Communication | USB Micro-B, RS-485 serial interface |
| Software Compatibility | Windows 10, tri-lingual UI (English, Japanese, Chinese) |
| Max Expandable Channels | 144 (via up to 12 × MODEL 1592-0C analog output modules) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Channel Capacity | 12 simultaneous analog input channels |
| Probe Compatibility | 15 interchangeable probe models |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Unit Dimensions | 220 × 130 × 40 mm |
| Unit Weight | 0.6 kg |
| Communication | USB Micro-B, RS-485 serial (via standardized cable), LAN (optional via software interface) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 1580-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Channels | 12 simultaneous |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (Unit) | 220 × 130 × 40 mm |
| Weight (Unit) | 0.6 kg |
| Communication | USB Micro-B, RS-485 serial |
| Software | Windows 10-compatible, tri-lingual (EN/JP/CN), real-time 144-channel data logging capability |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 1580-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Channels | 12 simultaneous inputs |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (Unit) | 220 × 130 × 40 mm |
| Weight (Unit) | 0.6 kg |
| Communication | USB Micro-B, RS-485 serial interface |
| Compliance | CE, RoHS, JIS B 7951 (thermal anemometry), ISO 14644-3 (cleanroom monitoring support) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer-Based Environmental Data Acquisition System |
| Resolution | 0.01 m/s (wind speed) |
| Measurement Range | Configurable per probe (0.01–50.0 m/s wind speed, 0–120 °C temperature, 5–95% RH humidity) |
| Accuracy | ±2% or ±0.02 m/s (wind), ±0.5 °C (temperature), ±3% RH (5–80% RH), ±5% RH (80–90% RH) |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −10–60 °C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Display | 7-inch color LCD touchscreen |
| Data Storage | 8 GB internal memory (24,500 measurements per module) |
| Communication | USB 2.0, LAN (TCP/IP), RS-485 serial |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Max Channels | 144 (12 modules × 12 probes each) |
| Probe Compatibility | 15 interchangeable thermal anemometer and thermo-hygrometric probes |
| Analog Output | 12-channel module supports 0–5 V (1 kΩ) or 4–20 mA (250 Ω) per channel |
| Software | Windows 10-compatible, tri-lingual (English/Japanese/Chinese), real-time charting, CSV export, configurable averaging/min/max/statistics |
| Brand | Kanomax |
|---|---|
| Origin | China (Liaoning) |
| Model | 1590-0C |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s (dependent on probe selection) |
| Accuracy | ±2% or ±0.02 m/s (whichever is greater), ±3% for selected probes |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −10–60 °C |
| Relative Humidity | 0–85% RH (operating, non-condensing), 0–90% RH (storage, non-condensing) |
| Display | 7-inch color LCD touchscreen |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (main unit) | 220 × 130 × 40 mm |
| Weight | 0.6 kg |
| Data Storage | 8 GB internal memory (up to 24,500 measurements per module) |
| Communication | USB Type-A (for storage), RS-485 serial (probe interface), LAN (optional via software) |
| Software | Windows 10-compatible, multilingual (English, Chinese, Japanese) |
| Max Channels | 144 (12 modules × 12 probes each) |
| Probe Compatibility | 15 interchangeable thermal anemometer probes, including directional/non-directional, standard/high-temperature (up to 120 °C), and ultra-compact variants |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer-Based Environmental Monitoring System |
| Model | 1590-0C |
| Resolution | 0.01 m/s |
| Measurement Range | Configurable per probe (0.01–50.0 m/s wind speed) |
| Accuracy | ±2% or ±0.02 m/s (whichever is greater), ±0.5°C temperature, ±3% RH (5–80% RH) |
| Operating Temperature | 5–40°C |
| Operating Humidity | 0–85% RH (non-condensing) |
| Display | 7-inch color LCD touchscreen |
| Data Storage | 8 GB internal memory (24,500 measurements per unit) |
| Communication | USB 2.0, LAN (RJ45), serial interface |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Dimensions (Unit) | 220 × 130 × 40 mm |
| Weight | 0.6 kg |
| Compliance | Designed for ISO 14644-1/3, EU GMP Annex 1, USP <1116>, and FDA 21 CFR Part 11-ready data integrity workflows |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–50.0 m/s (dependent on probe selection) |
| Accuracy | ±2% of reading or ±0.02 m/s (whichever is greater), ±3% for specific probe models |
| Operating Temperature | 0–60 °C (probe-dependent up to 120 °C) |
| Operating Humidity | 0–90 %RH (non-condensing) |
| Display | 7-inch color LCD touchscreen |
| Data Storage | 8 GB internal memory (24,500 measurements per module) |
| Communication | USB, LAN |
| Power Supply | AC 100–240 V or DC 12–24 V |
| Max Channels | 144 (12 modules × 12 probes) |
| Probe Compatibility | 15 interchangeable thermal anemometer probes |
| Analog Output | 0–5 V / 4–20 mA per channel (configurable per channel) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 2212 |
| CO Range | 0–500 ppm |
| CO₂ Range | 0–5000 ppm |
| Temperature Range | −20 to +60 °C |
| Relative Humidity Range | 2–98 %RH |
| CO Accuracy | ±3% of reading or ±3 ppm (whichever is greater) |
| CO₂ Accuracy | ±3% of reading |
| Temperature Accuracy | ±0.5 °C |
| RH Accuracy | ±2 %RH (2–80 %RH), ±3 %RH (80–98 %RH) |
| Data Storage | 1500 records |
| Interface | USB |
| Power | 6 × AA batteries or optional AC adapter |
| Weight | 400 g |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 2212+ |
| CO Range | 0–500 ppm |
| CO₂ Range | 0–5000 ppm |
| Temperature Range | −20 to +60 °C |
| Relative Humidity Range | 2–98 %RH |
| CO Accuracy | ±3% of reading or ±3 ppm (whichever is greater) |
| CO₂ Accuracy | ±3% of reading |
| Temperature Accuracy | ±0.5 °C |
| RH Accuracy | ±2 %RH (2–80 %RH), ±3 %RH (80–98 %RH) |
| Data Storage | 1,500 sets |
| Interface | USB |
| Output | 0–1 V analog (optional) |
| Power | 6 × AA batteries or optional AC adapter |
| Weight | 400 g |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C / 3000-C1 |
| Particle Size Range | 0.015–1.0 µm (3000-C1), 0.02–1.0 µm (3000-0C) |
| Counting Range | 0–100,000 particles/cm³ |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation | Direct Cout/Cin ratio |
| Test Agent | ≥99.5% isopropanol or ethanol |
| Display | 7-inch full-color TFT touchscreen |
| Operating Temperature | 10–35 °C, 20–85% RH (non-condensing) |
| Storage Temperature | −20–50 °C, 0–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions (W×H×D) | 208×117×262 mm (3000-0C), 208×152×263 mm (3000-C1) |
| Weight | 2.3 kg (3000-0C), 3.1 kg (3000-C1) |
| Communication Interfaces | USB, Ethernet, Wi-Fi |
| Data Export | Microsoft Excel-compatible reports |
| Software Compatibility | Windows 7/8/10, .NET Framework 3.5 |
| Multi-unit Control | Up to 4 units per PC |
| Supported Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, UK HSE INDG479, GB 19083–2010, GB 2626–2019, GB/T 32610–2016 |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Model | 3000-0C |
| Particle Size Range | 0.02–1.0 µm |
| Concentration Range | 0–100,000 particles/cm³ |
| Sample Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation Method | Direct Cout/Cin Ratio |
| Test Agent | Isopropanol (≥99.5% purity) or Ethanol |
| Display | 7-inch TFT color touchscreen |
| Languages | English, Japanese, Chinese, French, Spanish, Portuguese |
| Compliance Standards | OSHA, CSA Z94.4, ANSI/AIHA RP-01, HSE HSG53, GB 19083–2010, GB 2626–2019, GB/T 32610–2016 |
| Data Storage | USB flash drive |
| Communication Interfaces | USB 2.0, Ethernet (10/100BASE-T), Wi-Fi (802.11b/g/n) |
| Software Compatibility | Windows 7/8/10, .NET Framework 3.5 |
| Report Format | Microsoft Excel (.xlsx) |
| Operating Environment | 10–35 °C, 20–85% RH (non-condensing) |
| Storage Conditions | −20–50 °C, 0–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions (W×H×D) | 208 × 117 × 262 mm |
| Weight | 2.3 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C |
| Compliance | OSHA 29 CFR 1910.134, CSA Z94.4, NIOSH 42 CFR Part 84 |
| Display | 7-inch full-color capacitive touchscreen |
| Control | Standalone operation or PC-controlled (up to 4 units via LAN/Wi-Fi/USB) |
| Language Support | English, French, Spanish, Portuguese |
| Interface | USB 2.0, 10/100 Mbps Ethernet, IEEE 802.11 b/g/n Wi-Fi |
| Construction | CNC-machined aluminum chassis |
| Test Modes | Quantitative fit testing for disposable respirators (N95, N99, P3, KN95, HEPA), half-mask, full-facepiece, gas mask, PAPR, and SCBA respirators |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | Kanomax 3000-0C |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 1910.134, CSA Z94.4 |
| Measurement Principle | Condensation Nucleus Counter (CNC)-based Ambient Aerosol Testing |
| Test Modes | Qualitative (screening) & Quantitative (TIL-based) |
| Supported Respirators | Disposable particulate respirators (N95, KN95, KP95, N100, KN100), half-mask & full-facepiece elastomeric respirators, PAPRs |
| Language Interface | English, Japanese, Chinese, Korean, German |
| Connectivity | USB, Ethernet, Wi-Fi (client mode) |
| Multi-unit Control | Up to 4 units via single PC |
| Pass/Fail Thresholds | KN95/KP95 ≤ 8% TIL |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C |
| Particle Size Range | 0.02–1.0 µm |
| Count Concentration Range | 0–100,000 particles/cm³ |
| Sample Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation Method | Direct (Cout/Cin) |
| Challenge Agent | ≥99.5% purity isopropanol or ethanol |
| Display | 7-inch full-color touchscreen |
| Operating Temperature | 10–35 °C |
| Relative Humidity | 20–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm (W × H × D) |
| Weight | 2.3 kg |
| Compliance Standards | OSHA, CSA Z94.4, ANSI/AIHA Z88.10, UK HSE, GB 19083–2010, GB 2626–2019, GB/T 32610–2016 |
| Communication Interfaces | USB, Ethernet, Wi-Fi |
| Software Compatibility | Windows 7/8/10, .NET Framework 3.5 |
| Data Export Format | Microsoft Excel |
| Storage | USB flash drive |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C/C1 |
| Particle Size Range | 0.02–1.0 µm (CPC mode) / 0.015–1.0 µm (C1 mode) |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation Method | Direct Cout/Cin ratio |
| Test Agent | Isopropanol (≥99.5% purity) or ethanol |
| Display | 7-inch full-color touchscreen |
| Supported Languages | English, Japanese, Chinese, French, Spanish, Portuguese |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, HSE INDG479, GB 19083–2010, GB 2626–2019, GB/T 32610–2016 |
| Connectivity | USB, Ethernet, Wi-Fi |
| Data Export Format | Microsoft Excel (.xlsx) |
| Operating Environment | 10–35 °C, 20–85% RH (non-condensing) |
| Dimensions (3000-0C) | 208 × 117 × 262 mm |
| (3000-C1) | 208 × 152 × 263 mm |
| Weight (3000-0C) | 2.3 kg |
| (3000-C1) | 3.1 kg |
| Software Compatibility | Windows 7/8/10, .NET Framework 3.5 |
| Max Simultaneous Units per PC | 4 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3000-C1+ |
| Particle Size Range | 0.02–1.0 µm |
| Counting Range | 0–100,000 particles/cm³ |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation | Direct Cout/Cin Ratio |
| Test Modes | N95, DS2, DL2, RS2, RL2 |
| Display | 7-inch TFT color touchscreen |
| Languages | English, Japanese, Chinese, French, Spanish, Portuguese |
| Compliance | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, HSE INDG479, GB19083-2010, GB2626-2019, GB/T 32610-2016 |
| Data Interface | USB, Ethernet, Wi-Fi |
| Software Control | Up to 4 units per PC |
| Operating Environment | 10–35 °C, 20–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions (W×H×D) | 208 × 152 × 263 mm |
| Weight | 3.1 kg |
| Reagents | ≥99.5% isopropanol or ethanol |
| Report Format | Microsoft Excel (.xlsx) |
| OS Compatibility | Windows 7/8/10, .NET Framework 3.5 |
| Brand | Kanomax |
|---|---|
| Origin | China (Liaoning) |
| Model | 3000-C1 |
| Particle Size Range | 0.015–1.0 µm |
| Aerosol Concentration Range | 0–100,000 particles/cm³ |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation Method | Direct Cout/Cin Ratio |
| Test Agent | ≥99.5% Isopropanol or Ethanol |
| Display | 7-inch TFT color touchscreen |
| Operating Temperature | 10–35 °C |
| Relative Humidity (Operating) | 20–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions (W×H×D) | 208 × 152 × 263 mm |
| Weight | 3.1 kg |
| Communication Interfaces | USB, Ethernet, Wi-Fi |
| Software Compatibility | Windows 7/8/10, .NET Framework 3.5 |
| Data Export Format | Microsoft Excel |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, UK HSE INDG 479, GB 19083–2010, GB 2626–2019, GB/T 32610–2016 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-C1 |
| Particle Size Range | 0.015–1.0 µm |
| Concentration Range | 0–100,000 particles/cm³ |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation Method | Direct Cout/Cin ratio |
| Test Agent | ≥99.5% Isopropyl Alcohol or Ethanol |
| Display | 7-inch true-color touchscreen |
| Languages | English, Japanese, Chinese, French, Spanish, Portuguese |
| Compliance Standards | OSHA 29 CFR 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, HSE INDG479, GB 19083–2010, GB 2626–2019, GB/T 32610–2016 |
| Communication Interfaces | USB, Ethernet, Wi-Fi |
| Software Compatibility | Windows 7/8/10, .NET Framework 3.5 |
| Data Export Format | Microsoft Excel |
| Operating Environment | 10–35 °C, 20–85% RH (non-condensing) |
| Dimensions (W×H×D) | 208 × 152 × 263 mm |
| Weight | 3.1 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3116 |
| Acceleration Range | 0.02–200 m/s² RMS |
| Velocity Range | 0.02–200 mm/s RMS |
| Displacement Range | 2–2000 µm EQp-p |
| Accuracy | ±5% |
| Frequency Range (Acceleration) | 3 Hz–10 kHz |
| Frequency Range (Velocity) | 10 Hz–1 kHz (compliant with JIS B 0907:1989) |
| Frequency Weighting | 10–400 Hz band-limited for vibration severity evaluation |
| AC Output | 1 Vrms (full scale) |
| Headphone Output | Yes, with volume control |
| Communication Interface | RS-232C |
| Power Supply | Two AAA batteries or optional AC adapter |
| Dimensions | 145 mm (H) × 48 mm (W) × 23 mm (D) |
| Weight | Approx. 130 g |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3116+ |
| Acceleration Range | 0.02–200 m/s² RMS |
| Velocity Range | 0.02–200 mm/s RMS |
| Displacement Range | 2–2000 µm EQp-p |
| Accuracy | ±5% |
| Frequency Range (Acceleration) | 3 Hz–10 kHz |
| Frequency Range (Velocity) | 10 Hz–1 kHz (compliant with JIS B 0907:1989) |
| Frequency Weighting | 10–400 Hz bandpass for vibration evaluation |
| AC Output | 1 Vrms (full scale) |
| Headphone Output | Yes, with volume control |
| Communication Interface | RS-232C |
| Power Supply | Two AAA batteries or optional AC adapter |
| Dimensions | 145 mm (H) × 48 mm (W) × 23 mm (D) |
| Weight | Approx. 130 g |