| Brand | MicroChem Corp |
|---|---|
| Origin | USA |
| Product Type | Photoimageable epoxy-based wafer bonding adhesive |
| Series | PermiNex™ 1000 and 2000 |
| Temperature Resistance | <200 °C cure |
| Resolution | High-resolution patterning |
| Aspect Ratio | Up to 3:1 |
| Developer Compatibility | Aqueous alkaline solutions |
| Substrate Adhesion | Silicon, glass, quartz, SiO₂, SiNₓ |
| Shelf Life Storage | 4–21 °C |
| Corrosivity | Low metal ion contamination |
| Conformality | Void-free, conformal interface |
| Edge Acuity | Sharp, crack-free pattern edges |
| Reliability | Qualified for HAST (JESD22-A110) and TCT (JESD22-A104) |
| Seal Integrity | High hermeticity post-bond |
| Process Compatibility | Compatible with dicing, laser welding, and backend packaging steps |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Country of Origin | China |
| Capacity Options | 60 mL, 90 mL, 120 mL, 150 mL, 180 mL |
| Pricing | Upon Request |
| Brand | Binzhenghong |
|---|---|
| Model | 1/4″ PFA Three-Way Valve |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Pricing | Upon Request |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Classification | Domestic |
| Capacity Range | 10 mL to 1000 mL |
| Pricing | Upon Request |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Origin Category | Domestic |
| Grade | Class A |
| Pricing | Available Upon Request |
| Brand | Pfeiffer Vacuum |
|---|---|
| Model | ADPC 302 |
| Origin | France |
| Type | In-line Dry Particle Counter for Semiconductor Front-Opening Unified Pod (FOUP) and Front-Opening Shipping Box (FOSB) |
| Measurement Range | 0.1 µm – 5.0 µm |
| Counting Principle | Laser Light Scattering (LLS) with Automated Surface Scanning |
| Cycle Time | ≤7 min per FOUP/FOSB |
| Throughput | Up to 8 carriers/hour |
| Compliance | SEMI S2/S8, ISO 14644-1 Class 1–ISO Class 3 environments |
| Interface | Ethernet/IP, SECS/GEM compatible |
| Operating Mode | Fully Automated, Unattended, Integrated into 300 mm Fab Automation |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | QCL2 500 |
| Pricing | Available Upon Request |
| Current Noise Density | ≤928 nA<sub>p-p</sub> (0.1–10 Hz) |
| RMS Noise | 36.7 nA/√Hz (1 Hz–100 kHz) |
| Output Current Range | 0–500 mA |
| Short-Term Stability | 310 ppm (after 1 h warm-up) |
| Long-Term Stability | 820 ppm (24 h after 1 h warm-up) |
| Temperature Coefficient | 6–15 ppm/°C |
| Output Voltage Compliance | ±24 VDC |
| Rise/Fall Time | 3.6 µs / 2.6 µs (RL = 36 Ω, 10%–90%) |
| Slew Rate | 160 A/ms |
| Leakage Current | ≤500 µA |
| Supply Voltage | ±18 to ±25 VDC |
| Dimensions | 78 × 108 × 40 mm |
| Weight | 0.13 kg |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.03–3000 µm (configurable sensor modules) |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368 |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Counting Resolution | Customizable channels (e.g., 1–100 µm, 4–70 µm(c), 0.1 µm(c)) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Sampling Precision | <±1% |
| Output | 4–20 mA analog signal |
| Alarm | Configurable particle concentration threshold alert |
| Data Interface | iPad-compatible wireless acquisition |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC & touchscreen) |
| Compliance | Supports 21 CFR Part 11 audit trail (optional configuration), GLP/GMP traceability mode |
| Power Input | 100–265 VAC, 50–60 Hz |
| Application Mode | Online continuous monitoring & offline portable/fixed sampling |
| Brand | PULUODY |
|---|---|
| Model | PMT-2-C |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Measuring Range | 0.05–0.2 µm, 0.1–0.5 µm (standard) |
| Sampling Method | Precision Metering Piston Pump + Electromagnetic Flow Control |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Data Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination code |
| Compliance Standards | JJG 1061, ISO 21501-4, USP <788>, EP 2.9.19 |
| Software Platform | V8.3 Integrated Analysis & Calibration Software (PC + touchscreen UI) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Brand | PULUODY |
|---|---|
| Model | PMT-2801 |
| Detection Principle | Dual-laser light scattering (narrow-beam, 8th-generation) |
| Particle Size Range | 0.1–0.5 µm (standard) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Flow Control | Precision piston pump + electromagnetic flow regulation |
| Compliance | USP <788>, EP 2.9.19, BP, ChP 2015/2020, GB 8368, ISO 21501-4, JJG 1061 |
| Data Output | 4–20 mA analog interface |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen GUI) |
| Operating Interface | Color LCD touch screen + optional wireless keyboard/mouse |
| Brand | PULUODY |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2DN |
| Price | USD 75,000 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Calibration Standards | JJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Reference Standards |
| Detection Range | 0.1–0.5 µm (standard) |
| Customizable | 1–100 µm or 4–70 µm (c) |
| Minimum Detectable Size | 0.1 µm (c) |
| Sampling Accuracy | < ±1% |
| Measurement Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Data Reporting | Particles per mL + ISO 4406 / NAS 1638 contamination code |
| Power Input | 100–265 VAC, 50–60 Hz |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Analysis & Calibration Suite (PC & embedded) |
| Brand | PULUODY |
|---|---|
| Model | PMT-2LS |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Detection Range | 0.1–0.5 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±3% typical |
| Volume Accuracy | ±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog interface with programmable contamination alarm |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 / SAE AS4059 contamination codes |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen UI) |
| Display | Color LCD touch interface + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO Class 1–5 cleanroom environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PS8011+ |
| Price Range | USD 135 – 525 |
| Material Options | PP, PE, PFA, PEEK, PFAD, High-Silica Borosilicate Glass |
| Volume Options | 50 mL to 1000 mL |
| Particle Cleanliness Level | RCL < 15 particles per 100 mL |
| Certified Cleanliness Classes | ISO Class 1–9 (per ISO 14644-1) |
| Particle Detection Thresholds | 0.1 µm, 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 5.0 µm |
| Average Outgoing Quality Limit (AOQL) | 0.5% |
| Compliance Standards | ISO 3722, ISO 14644-1, GB/T 17484, GB 50073-2001, JIS B9925:1997, JIS K0554:1995 |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Quant Nuova |
| Pricing | Upon Request |
| Brand | Rayscience |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WCT-120 |
| Measurement Principle | QSSPC (Quasi-Steady-State Photoconductance) |
| Lifetime Range | 100 ns – 10 ms |
| Test Modes | QSSPC, Transient, Lifetime Normalization Analysis |
| Resistivity Range | 3–600 Ω/sq. (undoped) |
| Carrier Injection Range | 1×10¹³ – 1×10¹⁶ cm⁻³ |
| Sensor Diameter | 40 mm |
| Sample Diameter | 40–210 mm (customizable down to smaller sizes) |
| Silicon Thickness | 10–2000 µm |
| Ambient Temperature | 20–25 °C |
| Power Consumption | Tester: 40 W |
| Controller PC | 200 W |
| Light Source | 60 W |
| Input Voltage | 100–240 VAC, 50/60 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | D-180, D-125 |
| Pricing | Available Upon Request |
| Brand | Rikori |
|---|---|
| Model | LQ-5Z-TMAH |
| Origin | Japan |
| Application | Single-component aqueous alkaline/acidic solution concentration measurement (TMAH, NaOH, Na₂CO₃, NH₃·H₂O, H₂SO₄, HNO₃, HCl) |
| Measurement Principle | Conductivity-based electrochemical sensing with temperature-compensated calibration |
| Range (TMAH) | 0.00–5.00 % w/w or 0.0–50.0 g/L |
| Temperature Range | 0.00–40.00 °C |
| Sensor Type | Chemically resistant 4C-type electrode (1 m cable) |
| Enclosure Rating | IP66 |
| Power | 3× LR03 alkaline batteries (auto-shutdown enabled) |
| Dimensions (main unit) | 38 × 75 × 180 mm (H×W×D) |
| Weight | ~300 g (unit), ~50 g (electrode) |
| Brand | Royce |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AP+ |
| Pricing | Available Upon Request |
| Chip Size Range (Tray) | 0.2 mm² – >25 mm² |
| Chip Size Range (Tape) | 0.5 mm² – ≤17 mm² |
| Input Formats | Tape & Reel Carriers, Waffle Packs, Gel-Paks (2"–4"), JEDEC Trays, Wafer Frames (up to Ø300 mm), Dicing Tape Rings |
| Output Formats | Carrier Tapes (8–24 mm width, heat-seal or pressure-seal), Waffle Packs, Gel-Paks (2"–4"), JEDEC Trays, Tape Frames, Dicing Tape Rings, Custom Fixtures |
| Placement Accuracy | ±12.5 µm (repeatability) |
| Pick Mechanism | Top-surface or edge-vacuum pickup using interchangeable tooling (Rubber, Vespel®, Tungsten Carbide, Elastomer) |
| Cycle Time | As low as 1.3 seconds per die (application-dependent) |
| Brand | Scientech |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Yes |
| Model | 12-inch |
| Pricing | Available Upon Request |
| Brand | SPELS |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | LSS-3 |
| Pricing | Upon Request |
| Brand | MicroChem |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | SU-8 2000 and 3000 Series |
| Pricing | Available Upon Request |
| Brand | Sumitomo |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SAW-20US |
| Price Range | USD 1,050,000 – 1,210,000 |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MN-151 Micromanipulator |
| Pricing | Available Upon Request |
| Material | Lightweight Aluminum Alloy |
| Mounting | Side-mount compatible with standard microscope stages |
| Operation | Ambidextrous (left- or right-hand configurable) |
| Coarse Motion Range (X/Y/Z) | 25 mm / 20 mm / 25 mm |
| Fine Motion Range (X) | 8 mm (MN-152 adds X-axis fine adjustment) |
| Z-axis Fine Control | Linear push-button actuator with 250 µm full stroke, 5 µm minimum incremental displacement |
| Dimensions (W×D×H) | 121 × 36 × 145 mm |
| Weight | 330 g |
| Compatible Accessories | B-8B Ball Joint, P-1A Height Adjustment Plate, H-7 Pipette Holder, Allen Wrench Set |
| Brand | SVT Associates |
|---|---|
| Origin | USA |
| Model | SSA Pro 100/150-25, SSA Pro 250/200-10 |
| Crucible Capacity | 10–100 cc |
| Beam Uniformity | ±1.5% over 100 mm² at 150 mm source-to-substrate distance (SSA Pro 100/150-25) |
| Beam Current Stability | ±1.0% |
| Beam Response Time | ≤250 ms |
| Shutter Actuation Time | <0.5 s |
| Maximum Deposition Rate | >10 Å/s (Alq₃ at 340 °C |
| Substrate Temperature | <40 °C during operation |
| Brand | SVT Associates |
|---|---|
| Origin | USA |
| Model | SVTA-C-30000 |
| Capacity | 30,000 cc |
| Compatible Materials | Se, Te, S |
| Feedthrough Flange | 4.5″ (DN63) CF (custom sizes available) |
| Max Bulk Evaporation Temperature | 450 °C / 500 °C (outgassing) |
| Diverting Aperture Max Temperature | 700 °C / 900 °C (outgassing) |
| Source Temperature Stability | ±0.1 °C |
| Thermocouple Type | K-type |
| Electrical Connectors | Amphenol circular feedthrough (filament), Omega subminiature T/C connectors |
| Bakeout Temperature | 200 °C |
| Beam Flux Stability | <1% (with integrated beam flux sensor) |
| Max Operating Pressure | 1×10⁻⁴ Torr |
| Deposition Uniformity | ±6% at 300 mm source-to-substrate distance |
| Heating Time to 400 °C | <60 min |
| Cooling Time to 100 °C | <120 min |
| Key | Brand: SVT Associates |
|---|---|
| Origin | USA |
| Model Variants | SVTA-DF, SVTA-LTDF, SVTA-V, SVTA-EXCEL |
| Temperature Stability | ±0.1 °C |
| Temperature Repeatability | ±0.1 °C |
| Crucible Capacities | 60 cc to 1,000 cc |
| Max Operating Temp (SVTA-DF) | 1,600 °C |
| Max Operating Temp (SVTA-EXCEL) | 600 °C |
| Flange Types | DN63 CF (4.5″), DN100 CF (6.0″), DN150 CF (8.0″) |
| In-Chamber Length | 10–14″ (standard 12″) |
| Bakeout Temperature | 200 °C |
| Thermocouple Types | Type K (<1,000 °C), Type C (≥1,000 °C) |
| Filament Connectors | Amphenol ring-type |
| Thermocouple Connectors | Omega subminiature |
| Brand | SVT Associates |
|---|---|
| Origin | USA |
| Model | SVTA-LES-300 |
| Deposition Width | 300 mm |
| Source Capacity | 500 cc |
| Flange | 6″ (DN100) CF |
| Maximum Effusion Orifice Temperature | 1,600 °C |
| Maximum Bulk Heater Temperature | 1,500 °C |
| Source Temperature Stability | ±0.1 °C |
| Beam Flux Stability | <1% |
| Operating Pressure Range | ≤5×10⁻⁵ Torr |
| Thickness Uniformity | ±4% (at 300 mm source-to-substrate distance) |
| Thermocouple Type | Type C (Type K optional) |
| Cooling Time (from 100 °C) | <120 min |
| Bakeout Temperature | 200 °C |
| Cooling Water Connections | 2 × 1/4″ VCR (inlet & outlet) |
| Max Water Pressure | 80 psi |
| Flow Rate | 500 mL/min |
| Brand | McScience |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T5000 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Czech Republic |
| Model | ELITE |
| Type | Lock-in Thermography Inspection System for Semiconductor Failure Analysis |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments, compatible with GLP/GMP documentation workflows |