Physical Property Testing Instruments
Filter
Showing 6871–6900 of 12508 results
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | FMS |
| Sensor Count | 124 thermocouple-based heat flux sensors |
| Calibration Compliance | ASTM F1930 (Standard Test Method for Determining the Effectiveness of Flame-Resistant Clothing Materials and Garments When Exposed to Flash Fire Simulations Using an Instrumented Manikin) |
| Flame Array | Multi-nozzle butane burner array with programmable ignition and thermal profile control |
| Incident Heat Flux | Calibrated to 84 ± 2 kW/m² per ASTM F1930 |
| Data Acquisition | Synchronized high-speed thermal sampling (≥10 Hz per sensor), timestamped, GLP-compliant logging |
| Software Platform | FMS-Control v3.x with burn injury prediction algorithm (based on Henriques’ thermal damage integral model) |
| Structural Dimensions | Anthropometrically accurate adult male form (185 cm height, ISO 8559-compliant body geometry) |
| Enclosure | Class A fire-rated test chamber (UL 1709 compliant), integrated exhaust and gas safety interlocks |
| Regulatory Alignment | Supports ISO 13506-1:2017, NFPA 2112, EN ISO 11612, GB/T 38427–2019 |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | FPR |
| Standards Compliance | ISO 9239-1, ASTM E648, GB/T 11785 |
| Radiation Panel | 300 mm × 450 mm porous ceramic, mounted at 30° angle |
| Heat Flux Range | 0–50 kW/m² (water-cooled thermopile) |
| Thermopile Accuracy | <2% |
| Response Time | 0.2 s |
| Light Source | Tungsten filament lamp, 2900 ± 100 K |
| Photodetector | Silicon photodiode |
| Smoke Measurement | Transmittance-based optical density (OD), real-time DAQ via 15″ touchscreen PC |
| Air Supply | Integrated variable-frequency blower with Venturi gas-air mixer and flashback arrestor |
| Ignition | Pneumatically actuated T-shaped burner (propane) |
| Safety | Flame-out detection via thermal probe, automatic gas shutoff |
| Calibration | Motorized lift stage for thermopile positioning |
| Sample Holders | 3 stainless steel fixtures |
| Temperature Monitoring | Chimney thermocouple, chamber thermocouple, infrared radiometer for panel surface temperature |
| Software | Dedicated DAQ platform with synchronized heat flux, smoke density, transmittance, airflow, and time-stamped flame spread tracking |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | FPT |
| Compliance | BS 476-6:2009+A1:2009 |
| Heating Source | Dual 1000 W quartz radiant heaters + T-type gas burner |
| Power Control | Automated time-programmed output (530 J/s initial → 1800 W at 2 min 45 s → 1500 W at 5 min) |
| Temperature Monitoring | T-type thermocouples measuring ΔT between flue gas and ambient air |
| Data Acquisition | Real-time logging with automated I-index calculation per BS 476-6 Annex B |
| Sample Holders | Three stainless-steel-clad configurations for wall/ceiling linings |
| Combustion Chamber Lining | Calcium silicate board |
| Structural Frame | Stainless steel support chassis |
| Reporting | ASTM/ISO-compliant PDF export with audit trail metadata |
| Brand | MOTIS |
|---|---|
| Model | FRAT |
| Standard Compliance | UL 1685, IEEE 383, IEEE 1202 |
| Chamber Dimensions (L×W×H) | 2600 × 2600 × 3100 mm |
| Internal Volume | 20.28 m³ |
| Floor Area | 6.76 m² |
| Test Duration | 20 min |
| Burner Heat Release Rate | 20 kW (70,000 BTU/hr) |
| Burner Type | Venturi-mixed propane burner per IEC 60332-3 |
| Tray Dimensions | 305 × 76 × 2438 mm |
| Ladder Bar Width | 25 ± 6 mm |
| Ladder Rung Spacing | 229 mm |
| Temperature Monitoring | Thermocouples + bidirectional hot-wire anemometry in exhaust duct |
| Gas Control | Mass flow controller + solenoid valves |
| Data Acquisition | Dedicated DAQ board for flame & structural temperature logging |
| Safety | Manual emergency power cutoff (instrument only, excludes PC) |
| Brand | MOTIS |
|---|---|
| Model | FRF |
| Category | Full-Scale Fire Reaction Testing System |
| Compliance | ISO 9705:2003, GA111, GB/T 27904, GB/T 25207, GB 20286 Annex B & C |
| Gas Analyzers | Paramagnetic O₂ (0–25% vol), NDIR CO₂ (0–10% vol), NDIR CO (0–1% vol) |
| Data Acquisition | 16-bit analog I/O, K-type thermocouples (−200 °C to +1500 °C), dual-head sampling pump (≤30 m transfer), chilled dew point trap, integrated control & reporting software |
| Key Outputs | Peak/average HRR & SPR (0–2/10/12/20 min), mass flow (door & duct), smoke yield, CO/CO₂ generation, flashover detection & timing, surface temperature profiles, vertical gas temperature stratification at doorway |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FT-45 |
| Pricing | Available Upon Request |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | FVT |
| Compliance | GB/T 8333, ASTM D3014a |
| Burner Type | Bunsen burner |
| Maximum Flame Temperature | 900 °C |
| Thermocouple | Manually Positionable |
| Automation | Motorized Burner Translation |
| Flame Height Measurement | Calibrated Steel Scale |
| Gas Flow Control | Adjustable and Auto-Shutoff |
| Chamber Lining | PTFE-Coated Interior |
| Operation Mode | One-Touch Test Initiation |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCF |
| Pricing | Available Upon Request |
| Temperature Control | Programmable controller with standard temperature ramp profile (e.g., BS 8414 Annex A) |
| Test Duration | Up to 24 h continuous monitoring and control |
| Compliance | BS 8414-1:2015, BS 8414-2:2015 (aligned with draft GB/T 39173 under development) |
| Data Acquisition | Real-time display of furnace interior and specimen surface temperatures |
| Thermocouple Configuration | Integrated internal furnace thermocouples + dedicated specimen surface thermocouples |
| Specimen Handling | Freely accessible test chamber with standardized mounting interface for façade system assemblies |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | GCF |
| Compliance | GB/T 29416–2012 Annex C, BS 8414 |
| Temperature Control | Programmable controller with standardized temperature ramp profile |
| Test Duration | 24 h continuous monitoring |
| Thermocouple Configuration | Internal furnace thermocouples + surface-mounted sample thermocouples |
| Data Logging | Real-time temperature display and curve plotting |
| Pass/Fail Criteria | Based on thermal trajectory divergence (sample center temperature vs. furnace ambient temperature) |
| Software Functionality | Automated test execution, time-synchronized thermal data acquisition, and smoldering propensity classification per GB/T 29416–2012 |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HFT |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Application Domain | Automotive Interior Materials Testing |
| Compliance | GB 8410, FMVSS 302 |
| Ignition Time Setting | 15 s (automatically terminated) |
| Gas Control | Integrated needle valve and ball valve for precise propane flow regulation and shutoff |
| Sample Holder Options | Two interchangeable specimen holders |
| Specimen Mounting | Right-side insertion design for ergonomic operation |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HTI |
| Pricing | Available Upon Request |
| Standard Compliance | EN 367, ISO 9151, AQ 6103–2007 |
| Heat Flux | 80 kW/m² |
| Thermocouple Type | Copper Disc Calorimeter (ISO 9151-compliant) |
| Temperature Rise Thresholds | 12 °C and 24 °C above baseline (25 °C) |
| Cooling | Forced-air cooling for calorimeter |
| Control | Pneumatic actuation + PC-based software automation |
| Power Supply | 220 V, 50 Hz |
| Gas Supply | Propane + compressed air |
| Dimensions (W×H×D) | 500 × 500 × 500 mm |
| Ambient Test Environment | 25 ± 5 °C |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SFT |
| Compliance | ISO 5658-2, IMO Resolution A.653(16), GB/T 28752-2012 |
| Application Domain | Transportation (Marine, Rail, Automotive Interiors) |
| Radiation Panel Dimensions | 480 mm × 280 mm |
| Calibrated Heat Flux Range | 0–100 kW/m² (via water-cooled calorimeter) |
| Ignition Source | Ceramic-tube burner with propane/air or methane/air mixture |
| Data Acquisition | Thermocouple array (mV output), synchronized video capture, foot-switch-triggered timing |
| Cooling | Portable closed-loop water chiller for calorimeter stabilization |
| Software | PC-based control & analysis platform compliant with GLP audit trail requirements |
| Brand | MOTIS |
|---|---|
| Model | 503 |
| Standard Compliance | NFP 92-503 |
| Heat Flux Source | Calibrated Electric Radiant Panel |
| Flame Application | Fan-shaped Gas Burner |
| Flame Height Control | Rotameter-adjusted to 30 mm |
| Specimen Holder | Stainless Steel Frame with Needle-type Specimen Clamp |
| Test Duration | Programmable Automatic Timer |
| Radiant Heat Monitoring | Copper Disc Calorimeter (1 unit) |
| Construction | Domestic Manufacturing (Jiangsu, China) |
| Distributor Type | Authorized General Distributor |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MMS |
| Pricing | Available Upon Request |
| Standards Compliance | EN 348, ISO 9150, GB 8965.2–2009, GB/T 17599–1998 |
| Power Supply | 220 V AC, 50 Hz |
| Operating Environment | 20 ± 2 °C, 65 ± 5 % RH |
| Dimensions (W × H × D) | 800 × 1200 × 450 mm |
| Gas Supply | Oxygen and Acetylene |
| Burner Nozzle Diameter | 1.2 ± 0.1 mm |
| Specimen Pre-tension | 175 ± 0.5 g (via calibrated copper weight) |
| Droplet Guidance Angle | 45° with high-temperature anti-adhesion coated channel |
| Metal Feed Mechanism | Stepper motor–driven wire feed system with adjustable linear speed |
| Backside Temperature Sensor | Calibrated thermocouple array for real-time fabric rear-surface temperature monitoring |
| Data Logging | Automated temperature vs. time acquisition |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | MTT |
| Price Range | USD 14,000 – 28,000 |
| Application Field | Construction Materials |
| Compliance Standard | GB/T 20285 “Hazard Classification of Smoke Toxicity from Materials” |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NCF |
| Pricing | Available Upon Request |
| Temperature Control | PID → Constant Power Switching at 750±5°C |
| Max Furnace Temp | 900°C |
| Data Interface | RS-232C with Dedicated Acquisition Card |
| Calibration Compliance | ISO 1182 & GB/T 5464-2010 |
| Reporting | Automated Report Generation & Printing |
| Sensor Suite | Integrated Internal Thermocouple + Scanning Wall Thermocouples |
| Software Functions | In-Furnace & Wall Temperature Calibration Curve Mapping |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | NCF |
| Temperature Control | PID + Constant-Power Hybrid Mode |
| Operating Temperature | 750 ± 5 °C |
| Calibration | Dual Thermocouple System (360° Circumferential Wall Scan + Adjustable Internal Probe) |
| Data Interface | RS-232C with Dedicated Acquisition Card |
| Compliance | GB/T 5464–2010, GB 8624–2011 |
| Software | Integrated Calibration Curve Generation, Auto-Judgment Logic, Report Generation & Printing |
| Structural Design | Modular Furnace Assembly for Simplified Maintenance |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | NCF |
| Compliance | ISO 1182, GB/T 5464, BS 476-4 & BS 476-11, IMO FTP Code Part 1 |
| Temperature Control Range | 750 ± 5 °C |
| Heating Method | Radiant Tube with Kanthal® Resistance Band |
| Thermocouple Type | OMEGA™ Type K (NiCr-NiAl) |
| Temperature Monitoring Points | Furnace Chamber, Specimen Surface, Specimen Center |
| Calibration Capabilities | 360° Rotatable & Vertically Adjustable Thermocouple Scanning System for Furnace Wall and Internal Temperature Mapping |
| Airflow Stabilization | PTFE-Coated Stainless Steel Inverted Conical Air Stabilizer and Cylindrical Flow Guide |
| Software | Integrated Windows-Based Data Acquisition, Real-Time Curve Plotting, Automated Report Generation (PDF/Excel), ASTM/ISO-Compliant Data Logging with Timestamped Audit Trail |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OI |
| Price | USD 1,150 (FOB Jiangsu) |
| Measurement Principle | Limiting Oxygen Concentration (LOC) via upward flame propagation in vertical specimen under controlled O₂/N₂ mixture |
| Standards Compliance | ISO 4589-2, ISO 4589-3, GB/T 2408 |
| Oxygen Sensor Type | Electrochemical |
| O₂ Range | 0–100 vol% |
| Resolution | 0.1 vol% |
| Gas Flow Control | Dual mass flow controllers (O₂ and N₂), adjustable from 0–10 L/min, step resolution ≤ 0.1 L/min |
| Combustion Chamber | High-purity quartz glass tube (max. operating temp: 800 °C) |
| Ignition Source | Adjustable butane micro-flame igniter with gas cutoff |
| Humidity & Particulate Filtration | Integrated desiccant + sintered stainless-steel filter |
| Specimen Holders | Two sets — self-supporting and non-self-supporting clamps |
| Data Display | Digital dual-channel O₂% and total flow readout |
| Power Supply | 220 V AC, 50 Hz |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | PFET |
| Compliance | IMO A.753, ISO 19921–1 & 19921–2, ISO 10497, FTP Code Annex 2 (Res. A.753) |
| Test Pressure Range | 0–20 bar |
| Thermal Radiation Sensor | Calibrated heat flux meter (kW/m²) |
| Cooling System | Integrated water-cooled calorimeter mount |
| Temperature Monitoring | Dual K-type thermocouples (0–1200 °C) |
| Sample Positioning | Motorized X-Y-Z adjustable test platform |
| Data Acquisition | PC-based real-time logging software with time-synchronized thermal, pressure, and radiation curves |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | Polynorme 505 |
| Compliance | NF P92-505, EU Directive 95/28/EC |
| Radiant Flux | 30 kW/m² |
| Radiation Source | Epiradiator |
| Sample Holder | Adjustable-height stainless steel tray with cotton substrate support |
| Radiation Source Mount | Rotatable 90° stainless steel bracket |
| Power Display | Digital front-panel readout |
| Power Control | Precision radiant flux regulator |
| Height Gauge | Integrated calibratable positioning tool |
| Brand | MOTIS |
|---|---|
| Model | PSS |
| Origin | Shanghai, China |
| Compliance | BS 476-7, BS 6853 |
| Radiant Panel Size | 850 mm × 850 mm |
| Ignition Source | Electric spark igniter |
| Specimen Holder | Water-cooled vertical mount with calibrated scale |
| Heat Flux Sensor | NIST-traceable water-cooled calorimeter |
| Control System | PLC-based HMI with digital heat flux display |
| Safety Interlock | Automatic gas shutoff upon radiant panel flameout |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | RCF |
| Compliance | GB/T 30735-2014, ENV 1187 (t1), ISO 12468-1 |
| Sample Mounting Angle Range | 0–50° |
| Air Duct Adjustment Range | 0–35° |
| Airflow Capacity | up to 250 m³/min |
| Fan Motor Power | 5.5 kW |
| Radiation Panel Dimensions | 600 mm × 600 mm |
| Ignition Method | Electric Spark with Thermocouple-Monitored Flame Supervision |
| Wind Speed Measurement | Three Vane Anemometers (±0.1 m/s accuracy) |
| Construction Materials | SUS304 Stainless Steel Duct (2 mm thickness), Structural Steel Frame with Pneumatic & Servo-Driven Actuation |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | RFS |
| Standards Compliance | ASTM E162, ASTM E365, ASTM D3675 |
| Radiant Panel Dimensions | 300 × 460 mm |
| Reflector Surface | 305 × 457 mm, Porous Cement |
| Max Reflector Temp | 815 °C |
| Calibration Burner | Methane (95% purity, 20 L/min @ 150 mbar) |
| Pilot Burner | Acetylene (0.5 L/min @ 150 mbar) |
| Propane Burner | 1.0 L/s @ 20 mbar |
| Compressed Air Supply | 50 L/s @ 700 Pa water column |
| Exhaust Airflow Velocity | 0.5 m/s ±0.05 m/s |
| Black-Body Temperature Control Range | 180–230 °C (±5 °C accuracy) |
| Heat Flux Measurement Range | 0–100 kW/m² (±10% full scale, Schmidt-Boelter type) |
| Data Acquisition | GPIB/USB interface DAQ system with 19" touchscreen control unit |
| Frame Dimensions | 1850 H × 700 D × 1250 L mm |
| Electrical Supply | 220 V AC, 60 Hz, 12 A |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | RPT |
| Compliance | NF P92-501, TB/T 2639.1 |
| Heat Flux | 30 kW/m² |
| Key Outputs | Ignitability Index (i), Average Flame Height Index (S), Maximum Flame Height Index (h), Combustion Heat Release Index (C) |
| Construction | Stainless Steel Enclosure with Fire-Resistant Lining |
| Viewing Window | Tempered Quartz |
| Test Angle | 45° Inclined Specimen Mount |
| Radiant Source | Epiradiator with Power-Controlled Output |
| Burners | Dual Stainless Steel Burners (Upper & Lower), Pilot Ignition System |
| Flame Control | Adjustable Needle Valves with Height Gauge |
| Gas Shutoff | Quarter-Turn Isolation Valves |
| Temperature Monitoring | Top & Inlet Thermocouples |
| Software | Dedicated Test Suite with Automated Index Calculation, Report Generation & Data Export (CSV/PDF) |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | RRT |
| Heating System | 4000 W primary + 2000 W auxiliary electric heating elements with dual PID temperature control |
| Reflector | Stainless steel parabolic reflector |
| Headform | Metallic anthropomorphic headform with adjustable horizontal positioning rail |
| Thermal Flux Measurement | Water-cooled heat flux meter calibrated per ISO 8503-2 |
| Breathing Simulation | Programmable sinusoidal artificial lung (PLC-controlled |
| Failure Detection | Differential pressure sensor for real-time mask seal integrity monitoring |
| Compliance | EN 136:2023, GB/T 16556–2007 |
| Power Supply | 220 V AC, 30 A |
| Dimensions | 1400(W) × 600(D) × 1400(H) mm |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBI |
| Pricing | Available Upon Request |
| Compliance | EN 13823, GB/T 20284 |
| Measurement Principle | Oxygen Consumption Calorimetry + Optical Smoke Density Analysis + Visual Flame Spread Observation |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBI |
| Pricing | Available Upon Request |
| Standards Compliance | EN 13823, GB/T 20284 |
| Core Measurement Principles | Oxygen depletion calorimetry, optical smoke density analysis, flame spread observation, droplet collection |
| Key Outputs | FIGRA, THR, SMOGRA, TSP, LFS, flaming droplets/particles |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SBI |
| Compliance | EN 13823, GB/T 20284 |
| Measurement Principle | Oxygen depletion calorimetry + optical smoke density analysis + flame spread observation |
| Key Outputs | FIGRA, THR, SMOGRA, TSP, LFS, droplet formation assessment |
| Core Subsystems | Siemens-based gas analysis cabinet (O₂, CO, CO₂), data acquisition system, calibrated propane corner burner (31 kW), 3 m × 3 m × 2.4 m fire test chamber with conical hood and sampling duct |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | SBI |
| Combustion Source | 31 kW Propane Corner Burner (250 mm × 250 mm × 80 mm) |
| Test Chamber Dimensions | 3 m × 3 m × 2.4 m (W × L × H) |
| Exhaust Flow Rate | 0.50–0.65 m³/s at 298 K |
| Exhaust Duct | SUS304 J-type, Ø315 ±5 mm, insulated with 50 mm mineral wool |
| Cone Calorimetry-Compatible Sampling Zone Length | 2155 mm |
| Oxygen Analyzer | Servomex 4100 (paramagnetic, 16–21% v/v O₂, ≤12 s response, drift <100 ppm/30 min) |
| CO₂ Analyzer | Servomex 4100 (NDIR, 0–10% v/v CO₂, linearity ≥1% FS) |
| Smoke Obscuration System | Incandescent light source (2900 ±100 K), collimated beam ≥20 mm diameter, Si photodiode detector compliant with CIE V(λ) ±5% |
| Thermocouples | Three OMEGA K-type armored, 0.5 mm dia., spaced 120° on 87 ±5 mm radius circle |
| Pressure Transducer | ±2 Pa accuracy, ≤1 s 90% response |
| Mass Flow Controller | 0–2.5 g/s, ±1.5% reading accuracy |
| Propane Supply Control | Dual independent solenoid valves, switch time ≤12 s, flame stabilization ±5 mg/s for 30.7 ±2 kW output |