| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | DDM2909 |
| Instrument Type | Oscillating U-tube Densitometer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample State | Liquid |
| Density Range | 0–3 g/cm³ (operable from 32°F to 212°F) |
| Density Accuracy | ±0.0001 g/cm³ |
| Temperature Accuracy | ±0.05 °C |
| Density Repeatability | ±0.00002 g/cm³ |
| Temperature Repeatability | ±0.02 °C |
| Temperature Control Range | 0–70 °C |
| Minimum Sample Volume | < 1 mL |
| Display | 10.4″ color LCD touchscreen |
| Connectivity | 5× USB, 2× RS232, 2× Ethernet, 1× HDMI |
| Onboard Storage | 32 GB |
| Regulatory Compliance | 21 CFR Part 11 compliant software with audit trail, IQ/OQ documentation support |
| Key Feature | Video View™ technology (U.S. Patent No. 7,437,909) for real-time 10× magnified visualization of bubble formation and settling in the oscillating U-tube |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | DDM2910 |
| Instrument Type | Laboratory Benchtop Oscillating U-Tube Densitometer |
| Sample Type | Liquids |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.00001 g/cm³ |
| Density Repeatability | ±0.00001 g/cm³ |
| Temperature Control Range | 0–100 °C |
| Temperature Accuracy | ±0.03 °C |
| Temperature Repeatability | ±0.02 °C |
| Display Resolution | 0.0001 g/cm³ / 0.01 °C |
| Minimum Sample Volume | 1 mL |
| Viewing System | Video View™ (10× magnification, real-time U-tube bubble monitoring) |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready, IQ/OQ documentation available |
| Interface | 5× USB, 2× RS232, 2× Ethernet, 1× HDMI |
| Display | 10.4″ color TFT touchscreen |
| Onboard Storage | 32 GB SSD |
| Viscosity Correction | Automatic, integrated algorithm |
| Reference Cell | Built-in temperature-stabilized reference measurement cell |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | DDM2911 Autofill |
| Instrument Type | Oscillating U-Tube Density Meter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids |
| Density Range | 0–3 g/cm³ |
| Density Resolution | 0.000001 g/cm³ |
| Density Accuracy | ±0.000010 g/cm³ |
| Density Repeatability | ±0.000002 g/cm³ |
| Temperature Control Range | 0–100 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Repeatability | ±0.001 °C |
| Display Precision | 0.000001 g/cm³ / 0.001 °C |
| Minimum Sample Volume | 1 mL |
| Integrated Viscosity Correction | Yes |
| Regulatory Compliance | 21 CFR Part 11, GLP/GMP-ready |
| Data Storage | 32 GB internal memory |
| Interface Ports | 5× USB, 2× RS232, 2× Ethernet, 1× HDMI |
| Touchscreen | 10.4″ color LCD |
| Video View™ Technology | 10× digital zoom for real-time U-tube bubble visualization |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | DDM2911 Plus |
| Instrument Type | Oscillating U-Tube Density Meter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.000010 g/cm³ |
| Density Repeatability | ±0.000002 g/cm³ |
| Display Resolution | 0.000001 g/cm³ |
| Temperature Control Range | 0–100 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Repeatability | ±0.001 °C |
| Minimum Sample Volume | 1 mL |
| Built-in Reference Cell | Yes |
| Viscosity Correction | Automatic |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready |
| Data Interfaces | 5× USB, 2× RS232, 2× Ethernet, 1× HDMI |
| Display | 10.4″ Color TFT Touchscreen |
| Onboard Storage | 32 GB |
| Video View™ Magnification | 10× Real-time U-tube Imaging |
| Brand | Rudolph |
|---|---|
| Origin | USA |
| Model | DDM2911 + Autoflex R837 |
| Instrument Type | Oscillating U-tube Densitometer |
| Configuration | Benchtop Laboratory System |
| Sample Type | Liquids |
| Density Range | 0–3 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Density Accuracy | ±0.00005 g/cm³ |
| Temperature Control Range | 0–95 °C (100 °C optional) |
| Temperature Stability | ±0.01 °C |
| Minimum Sample Volume | 1 mL |
| Compliance | ASTM D4052, ASTM D5002, ASTM D1250, ASTM D5931-96, ISO 12185, DIN 51757 |
| Interface | USB ×5, RS-232, Ethernet (Cat-5) |
| Display | 10.4″ color TFT touchscreen |
| Construction | Borosilicate glass U-tube, PTFE fluidic interfaces |
| Data Storage | 32 GB internal flash memory |
| Operating System | Windows 7 Embedded |
| VideoView™ Technology (U.S. Patent No. 7,437,909) | 10× digital zoom for real-time bubble visualization across full U-tube length |
| Viscosity Compensation | Automatic in-situ correction |
| Regulatory Support | 21 CFR Part 11 compliant audit trail, electronic signatures, IQ/OQ/PQ documentation package |
| Power Input | 85–260 VAC, 50/60 Hz |
| Brand | RUMUL |
|---|---|
| Model | TESTRONIC |
| Origin | Switzerland |
| Type | Electromagnetic Resonant Fatigue Tester |
| Max Dynamic Load | ±250 kN |
| Static Load Capacity | 250 kN |
| Frequency Range | 40–300 Hz (8 discrete steps) |
| Frequency Control Accuracy | ±0.01 Hz |
| Dynamic Load Accuracy | ±0.5% |
| Static Load Accuracy | ±0.5% |
| Displacement Measurement Accuracy | ≤0.5% of reading |
| Vertical Test Space | >500 mm |
| Crosshead Travel | ≥300 mm |
| Test Table Dimensions | 690 × 840 mm with M16 T-slots |
| Resonance Damping | Optimized lateral elastic suspension |
| Compliance | ISO 7500-1 Class 1, ASTM E4, ASTM E647, DIN 969, ISO 3800 |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | TS-80 / TS-150 / TS-225 / TS-408 / TS-800 / TS-1000 |
| Internal Dimensions (W×H×D, cm) | 40×50×40 (80 L) to 100×100×100 (1000 L) |
| Temperature Range | −70 °C to +150 °C |
| Humidity Range | 20–98 % RH (optional low-humidity configuration down to 5 % RH) |
| Temp. Uniformity | ±0.5 °C |
| Humidity Uniformity | ±3 % RH |
| Temp. Stability | ±0.3 °C |
| Humidity Stability | ±2.5 % RH |
| Heating Rate | −70 °C → 100 °C in ≤60 min |
| Cooling Rate | 20 °C → −70 °C in ≤90 min |
| Control System | PID + SSR/SCR bidirectional output with slope logic |
| Programmability | 150 programs × 1500 segments, 9999 cycles × 999 loops |
| Safety Monitoring | 15-point real-time fault detection with auto-diagnostic logging |
| Refrigeration | Twin-stage hermetic air-cooled system (R404A/R507) |
| Construction | SUS#304 stainless steel interior & exterior |
| Insulation | Rock wool + rigid polyurethane foam |
| Power Supply | AC 220 V / 380 V ±10 %, 50/60 Hz |
| Key | Max Sample Mass: 1500 g |
|---|---|
| Mass Resolution | 0.01 g |
| Max Operating Temperature | 1600 °C (short-term up to 1650 °C) |
| Heating Rate | 0–10 °C/min |
| Isothermal Temperature Stability | ±2 °C |
| Atmosphere Options | Air, N₂, Ar |
| Chamber Pressure Range | −0.095 to 0.1 MPa |
| Power Supply | 220 V, 8 kW, 50 Hz |
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S-HT-30 |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | S005-1 |
| Pricing | Available Upon Request |
| Max. Tube Voltage | 10–100 kV |
| Max. Tube Current | 10–100 µA |
| Max. Output Power | 10 W |
| Focal Spot Size | 0.05 mm |
| X-ray Window Material | Beryllium or Glass |
| Radiation Beam Angle | 20°, 28°, or 30° |
| Operation Mode | Continuous Duty |
| Brand | Sabio |
|---|---|
| Model | 2030 |
| Measured Species | O₃ |
| Measurement Principle | UV Absorption Spectrophotometry |
| Range Options | 0–100 ppb, 0–200 ppb, 0–500 ppb, 0–1 ppm, 0–2 ppm |
| Zero Noise | <0.6 ppb |
| Limit of Detection | <1 ppb |
| Zero Drift | <1 ppb/24 h or <2 ppb/7 days |
| Span Drift | <1% per month |
| Response Time (T90) | 20 s (10 s lag) |
| Accuracy | ±1 ppb |
| Linearity | <1% FS |
| Sample Flow Rate | 1.0 LPM |
| Operating Temperature | 5–45 °C |
| Analog Outputs | 0–0.1 V, 0–1 V, 0–2 V, 0–5 V, 0–10 V (user-configurable, 4 channels) |
| Power Supply | 196–264 VAC, 50–60 Hz |
| Integrated High-Precision Ozone Generator | Output Range 0.05–1.5 ppm at 5 SLM, Accuracy ±2% of setpoint or ±3.0 ppb at 5 SLM |
| Environmental Compensation | Automatic temperature and pressure compensation |
| Connectivity | Ethernet (TCP/IP), USB, RS-232/RS-485 |
| Data Logging | Onboard non-volatile memory with timestamped records |
| Display | Large backlit TFT LCD with touch interface |
| Physical Design | Portable chassis with integrated side handles, ruggedized instrument case, built-in zero-air source |
| Brand | Saicheng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CHY-CA |
| Measuring Foot Diameter | 0–4 mm (selectable) |
| Brand | Saicheng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Saicheng NJY-20 |
| Max Torque | 50 N·m |
| Cap Diameter Range | Ø5 mm to Ø170 mm |
| Torque Resolution | 0.001 N·m |
| Power Supply | AC 220 V, 50 Hz |
| Compliance | GB/T 17876, ASTM D2063, ASTM D3198, ASTM D3474, BB/T 0025, BB/T 0034, GB/T 14803 |
| Brand | Saicheng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SCK-H |
| Price | USD 2,800 (FOB Qingdao) |
| Brand | Keysight (Distributed by Sakaguchi) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | DiM |
| Instrument Type | Advanced Driving Simulator (Fatigue & Dynamic Response Testing Platform) |
| Frequency Range | 0.1–30 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 12,500 (FOB) |
| Chamber Interior Dimensions (D×W×H) | 900 × 600 × 500 mm |
| External Dimensions (D×W×H) | 1410 × 880 × 1280 mm |
| Heating Power | 1.3–1.8 kW |
| Temperature Range | +5°C to 55°C |
| Humidity Range | 85–95% RH |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·h |
| Spray Mode | Continuous or Cyclic Programmable |
| Timer Range | 1 sec to 999 hours |
| Heating System | U-shaped Titanium Alloy Immersion Heater |
| Temperature Controller | High-Precision Digital PID Microcomputer Controller (±0.1°C Accuracy) |
| Sensor | PT100 Platinum Resistance Thermometer |
| Viewing Window | Full-Transparent Impact-Resistant Acrylic Lid with Water-Sealed Joint |
| Actuation | Pneumatic Lid Support Mechanism |
| Interior & Exterior Construction | Reinforced PVC Rigid Plastic Panels (UV-stabilized, corrosion-resistant, aging-resistant) |
| Included Accessories | One SO₂ Gas Cylinder (with Regulator) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Models | YW-150, YW-250, YW-750, YW-1000 |
| Pricing | Available Upon Request |
| Brand | Acoulab |
|---|---|
| Origin | South Korea |
| Model | SAM-SPICA |
| Instrument Type | Digital Scanning Acoustic Microscope |
| Transducer Frequency Range | 1–500 MHz |
| A/D Sampling Rate | 500 MHz |
| Signal Bandwidth | 1 GHz |
| XY Scan Speed | 1000 mm/s |
| XY Repeatability | ±0.5 µm |
| Scan Modes | A-scan, B-scan, C-scan, X-scan (multi-layer C-scan) |
| Sample Handling | Motorized tilt/rotation/translation stage with liquid coupling tank compatibility |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SC-1000, SC-1500 |
| Internal Working Dimensions | 1000 × 1000 × 1000 mm (SC-1000) |
| Mesh Wire Diameter | 50 µm |
| Nominal Mesh Spacing | 75 µm |
| Operating Ambient Temperature Range | 15–35 °C |
| Relative Humidity Range | 45–75 %RH |
| Talc Powder Concentration | 2–4 kg/m³ |
| Vibration Impact Duration | 0–99 h 59 min |
| Chamber Construction | Stainless steel inner chamber, electrostatically powder-coated steel outer enclosure, tempered glass observation door |
| Controller | Imported programmable logic controller (PLC) with selectable continuous or cyclic dust-blowing modes |
| Safety Protections | Leakage current protection, phase-loss protection |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SQ005B |
| Pricing | Available Upon Request |
| Cold Water Pressure Range | 0.05–0.5 MPa (Accuracy Class 1.0) |
| Hot Water Pressure Range | 0.05–0.5 MPa (Accuracy Class 1.0) |
| Flow Rate Measurement Range | 0.05–0.6 L/s (Accuracy Class 1.0) |
| Power Supply | 380 VAC, 36 kW |
| Cold Water Temperature Control | Ambient to 10 ± 1 °C |
| Hot Water Temperature Control | Ambient to 90 ± 1 °C |
| Cold Water Tank Capacity | 300 L |
| Hot Water Tank Capacity | 350 L |
| Compliant Standards | AS 3588:1996, EN 14688:2015, EN 14516:2006, EN 13310:2015 |
| Brand | Sanying Precision |
|---|---|
| Origin | Tianjin, China |
| Model | nanoVoxel-1000 |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Translation-Rotation (TR) |
| Spatial Resolution | 2 µm |
| Detail Resolution Capability | 300 nm |
| X-ray Source | Sealed-Tube |
| Maximum Tube Voltage | 110 kV |
| Field of View (FoV) | 300 mm (diameter) × 200 mm (height) |
| Sample Weight Capacity | 15 kg |
| System Dimensions (L×W×H) | 900 mm × 500 mm × 660 mm |
| Detector Active Area | 145 mm × 114 mm |
| Detector Pixel Matrix | 2940 × 2304 |
| System Mass | 500 kg |
| Brand | SASTEST |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | KCJ1000 |
| Instrument Type | Drop Weight Impact Tester |
| Impact Energy | 300 J |
| Maximum Lifting Height | 2000 mm |
| Hammer Head Radii | D25/SR50 and D90/SR50 |
| Max Sample Diameter | Φ400 mm (KCJ1302-A) to Φ1600 mm (KCJ1302-D) |
| Compliance Standards | GB/T 14152-2001, GB/T 10002.1-2006, GB 6112-1985 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 4,050 (approx.) |
| Internal Chamber Dimensions | Φ25×35 cm, Φ30×45 cm, Φ40×55 cm, Φ50×60 cm |
| Temperature Range | 105–132°C, 105–142.9°C, or 105–155°C |
| Pressure Range (gauge) | 0.2–2.0 kg/cm², 0.2–3.0 kg/cm², or 0.2–3.5 kg/cm² |
| Humidity Range | 65–100% RH (adjustable) |
| Controller | Dual-language (English/Chinese) touchscreen controller with USB and RS-232C interfaces, real-time data logging and curve export |
| Resolution | Temperature: 0.1°C, Humidity: 0.1% RH, Pressure: 0.1 kg/cm² |
| Temperature/Humidity Fluctuation | ±0.5°C / ±2.5% RH (non-saturated mode) |
| Uniformity | ±0.5°C / ±5% RH |
| Optional Bias Terminal Configuration | Standard: 8 terminals (8–55 configurable), AC/DC 125 V / 1 A |
| Pressurization Time | ~45–55 min depending on chamber volume and target pressure |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 4,100 (approx.) |
| Internal Dimensions (Φ×D, cm) | 30×45 / 40×55 / 50×55 / 60×65 |
| External Dimensions (W×H×D, cm) | 65×100×65 / 75×110×75 / 85×110×75 / 85×120×90 |
| Temperature Range | 121 °C, 132 °C (143 °C optional) |
| Humidity | 100 % RH (saturated steam) |
| Operating Pressure | 0–200 kPa(g) [0–2.0 kgf/cm²(g)] (300 kPa[g] optional) |
| Temp. Uniformity | ≤ ±2 °C |
| Humidity Uniformity | ≤ ±3 % RH |
| Circulation | Natural convection of saturated steam |
| Safety Protections | Low-water cutoff, overpressure relief, overtemperature shutdown, auto/manual water replenishment, pressure-actuated safety interlock |
| Standard Accessories | Two-tier stainless-steel sample racks |
| Power Supply | AC 220 V ±5 %, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SB-100 |
| Pricing Range | USD 70,000 – 110,000 |
| Measurement Principle | Transient Hot Wire Method (THW) with Dual Thermocouple Differential Voltage Sensing |
| Sample Dimensions | 2 mm – 10 mm length × 1–2 mm width × 1–2 mm height |
| Voltage Resolution | 50 nV |
| Minimum Heater Power Step | 0.1 mW |
| Maximum Measured Thermal Voltage Range | ±3 mV |
| Interface Options | GPIB, USB 2.0 |
| Software Included | Dedicated Thermoelectric Property Analysis Suite (TE-PAS v3.2) |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported |
| Model | Auto-Falling Needle |
| Instrument Type | Benchtop Fixed-Position Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.5–1,000,000 cP |
| Measurement Principle | Gravitational Sedimentation of Calibrated Needle in Fluid |
| Shear Rate Range | 10⁻⁴–10³ s⁻¹ |
| Temperature Range | −40 to +150 °C |
| Sample Volume Options | 2.3, 3.6, 7.2, 9.6, 19.2, or 120 cm³ |
| Needle Materials | Borosilicate Glass, Fused Quartz, or Stainless Steel |
| Standard Needle Length | 10.2 cm (compact version: 4.2 cm) |
| Needle Density Options | 1.01, 1.1, 1.5, 2.0, 3.0, 5.0, and 8.0 g/cm³ |
| Timing Resolution | 0.01 s (optional 0.001 s) |
| Interface | RS-232 Serial Port |
| Accuracy & Repeatability | < ±1% |
| Compliance | ASTM D1545, ISO 12058-1, USP <911>, GLP-Compatible Data Logging |
| Brand | SBS |
|---|---|
| Origin | USA |
| Instrument Type | Portable Falling-Pin Viscometer |
| Sample Tube | Disposable 4.5 mL glass tube |
| Measurement Principle | Gravitational falling-pin (Stokes’ law-based) |
| Viscosity Range | 1–10⁸ cP |
| Temperature Control Range | 0–100 °C |
| Timing Resolution | 0.001 s |
| Pin Density Range | 6–300 g/cm³ |
| Accuracy & Repeatability | <1% |
| Interface | RS232 |
| Compliance | ASTM D1200, ISO 2555, USP <911> (for kinematic viscosity correlation) |