| Brand | STKJ |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPDL-15 / SPDL-20 / SPDL-30 |
| Feed Rate | 3–9 kg/h |
| Effective Evaporation Area | 0.15–0.3 m² |
| Evaporator Internal Diameter | 280 mm |
| Condenser Surface Area | 0.58 m² |
| Collecting Flasks | 3 units |
| Construction Material | Borosilicate Glass 3.3 (DIN ISO 3585) with Optional Nickel-Based Alloy (e.g., Hastelloy C-276) and Tantalum Components |
| Maximum Evaporation Temperature | 250 °C |
| Minimum Operating Pressure | 0.001 mbar |
| Heating Method | External Oil Bath |
| Film Formation System | Self-Cleaning Roller-Type Wiper System |
| Brand | SFT |
|---|---|
| Origin | USA |
| Model | SFT-150 |
| Max. Operating Temperature | 350 °C |
| Max. Operating Pressure | 10,000 psi (68.9 MPa) |
| Extractor Volume Range | 50–4000 mL |
| Flow Rate | 1–330 mL/min (1–310 g/min) |
| Channel Configuration | Multi-channel optional |
| Solvent Compatibility | CO₂ (primary), with co-solvent injection capability |
| Heating Power | 2 kW per vessel |
| Temperature Accuracy | ±1 °C |
| Pressure Display Resolution | ±1 psi |
| Safety | Rupture disc for liquid CO₂ overpressure protection |
| Dimensions (L×W×H) | 92 × 61 × 76 cm |
| Net Weight (excl. vessels) | 60 kg |
| Brand | Newport |
|---|---|
| Origin | USA |
| Type | Imported Laboratory Diaphragm Compressor |
| Model Series | 46-14021-2, 46-14025-2, 46-14035-2, 46-14060-2, 46-14067, 46-14068 |
| Compression Principle | Pneumatically Actuated Metal Diaphragm |
| Flow Rate | 0–0.5 Nm³/h |
| Maximum Output Pressure | 0–200 MPa (0–30,000 psi) |
| Dew Point | +3 °C at Atmospheric Pressure |
| Particulate Filtration | <0.01 µm |
| Air Drive Inlet/Outlet Port | 0.053 cm / 1.27 cm |
| Fluid Side Port | 0.635 cm OD Tubing |
| Power Requirement | 50 Hz AC Supply |
| Compliance | Designed for ISO 8573-1 Class 2 compressed gas purity and GLP-compliant lab environments |
| Brand | GLOBUS |
|---|---|
| Origin | Italy |
| Application Scope | Laboratory to Industrial Scale |
| Construction Material | FDA- and GMP-compliant 316L Stainless Steel |
| Condenser Configuration | Internal Integrated Steam Condensation Chamber |
| Separatory Funnel | Double-jacketed Borosilicate Glass with Independent Temperature Control |
| Cooling System | Closed-loop Water Circulation Circuit |
| Safety Features | Calibrated Heat Meter + ASME-certified Safety Valve |
| Standard Vessel Capacity | 20–500 L |
| Custom Options | Extended-volume vessels & Dedicated Steam Generators Available |
| Brand | Newport |
|---|---|
| Origin | USA |
| Model | 4-5800 Series (ASTM E662 / FAA TSO-C135 Compliant) |
| Chamber Volume | 0.50 m³ |
| Optical Path Length | 914 mm |
| Sample Area | 0.0774 m² |
| Radiation Heat Flux | 2.5 W/cm² ±0.25 W/cm² |
| Power Supply | 230 V, 50–60 Hz |
| Dimensions (H×W×D) | 1956 × 1169 × 966 mm |
| Weight | 205 kg |
| Light Source | Tungsten-Halogen Lamp with ND2 Neutral Density Filter (Transmission Accuracy: 0.0001%) |
| Photodetector System | NIST-Traceable Silicon Photodiode Assembly |
| Data Acquisition | Real-time Transmittance vs. Time Plotting at 1 Hz Sampling Rate |
| Compliance | ASTM E662, ASTM F814, FAR 25.853, NFPA 258, BS 6401, FAA AC 20-135, ATS 1000.01, NES 711 |
| Brand | Newport Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lab-Scale High-Pressure Reactor Series |
| Price | USD $50,000 |
| Usable Volume Range | 23–4520 mL |
| Construction Material | Modular Corrosion-Resistant Alloy with Interchangeable Liners |
| Operating Pressure | Up to 139 MPa (20,000 psi) |
| Vacuum Capability | 46–139 MPa (absolute, gauge-referenced) |
| Oscillation Angle | 30° |
| Oscillation Frequency | 36 cycles/min |
| External Drive Motor | Integrated AC Servo |
| Pressure Gauge | Dual-scale Analog + Digital Output |
| Heating Jacket | Segmented Resistive Heating with Independent Thermal Zones |
| Liner Options | Removable Pyrex® Glass, Electroless Nickel-Coated Stainless Steel, or Custom Alloy Liners |
| Brand | LOEMI |
|---|---|
| Origin | Germany |
| Model Range | EBA-50 to EBA-2500 |
| Temperature Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Reaction Units | 1–5 independent chambers |
| Batch Capacity | 30–2000 L |
| Explosion Protection | ATEX II 2 G c T3 (Directive 94/9/EC) |
| Construction | Stainless Steel Vessels, Powder-Coated or Aluminized Enclosure |
| Compliance | ATEX, PED 2014/68/EU, EMCD 2014/30/EU, RoHS |
| Brand | CreaPhys |
|---|---|
| Origin | Germany |
| Model | DSU200 |
| Maximum Batch Capacity | 200 g |
| Base Vacuum | < 10⁻⁶ mbar (clean & dry system) |
| Evaporation Zone Temp Range | 100–500 °C |
| Deposition Zone Temp Range | 100–450 °C |
| Deposition Zone Temperature Uniformity | < ±10 °C |
| Footprint Diameter | 190 mm |
| Height | ~800 mm |
| Optional Accessories | Liquid Nitrogen Cold Trap, Glovebox Integration Kit |
| Brand | UIC GmbH |
|---|---|
| Origin | Germany |
| Model | KD 6 |
| Feed Rate | 3–9 kg/h |
| Effective Evaporation Area | 0.06 m² |
| Evaporator Inner Diameter | 180 mm |
| Condenser Area | 0.088 m² |
| Collecting Flasks | 3 |
| Operating Pressure Range | down to 0.001 mbar |
| Max Evaporation Temperature | 350 °C |
| Condenser/Cold Trap Temperature Range | –25 to 200 °C |
| Heating Method | Thermostatic Oil Circulation |
| Film Formation | Self-Cleaning Roller-Type Wiper System |
| Construction Material | AISI 316L Stainless Steel (optional: Hastelloy® variants) |
| Brand | Haage |
|---|---|
| Origin | Germany |
| Type | Laboratory-to-Industrial Reactor |
| Volume Range | 0.15–100 L |
| Operating Pressure | 50–3000 bar |
| Maximum Temperature | 700 °C |
| Construction | Forged High-Heat-Resistant Steel (Standard) |
| Vacuum Capability | Yes (down to <1 mbar, compatible with high-pressure operation) |
| Standard Safety Components | Certified Rupture Disc Assembly (with spare), Dual Thermocouple Monitoring (bulk & wall), Pressure Gauge, Gas Inlet/Outlet Valve, Sample Port, Magnetic Stirring Interface (optional), ATEX-Compliant Configuration Available |
| Optional Materials | Hastelloy®, Inconel®, Monel®, Nickel, Tantalum, Non-Metallic Linings (e.g., PTFE, SiC, Al₂O₃) |
| Optional Features | Digital Pressure Display, Integrated Condenser (top/bottom), Immersion Sampling Tube, Temperature-Limited Safety Interlock, Inert Gas Purge Valve, Bottom Drain Valve |
| Brand | SFT |
|---|---|
| Origin | USA |
| Model | PM-II with Phase Detection Capability |
| Max Temperature | 150 °C |
| Max Pressure | 10,000 psi (680 bar) |
| Extraction Vessel Volume | 30 mL |
| Flow Rate Range | 0–24.00 mL/min |
| Solvent Delivery | CO₂ + Co-solvent (e.g., methanol) |
| Vessel Construction | 316 Stainless Steel with 3/8″ Quartz Window |
| Pressure Accuracy | ±2 psi |
| Temperature Accuracy | ±0.5 °C |
| Video Monitoring | Color CCD Camera with NTSC Output |
| Power | 220 VAC, Single Phase |
| Dimensions (W×D×H) | 450×450×200 mm |
| Weight | 18.2 kg |
| Brand | CreaPhys |
|---|---|
| Origin | Germany |
| Model | DSU-Metal Series |
| Crucible Volume | 1 cm³ / 2 cm³ (custom volumes available) |
| Achievable Metal Layer Thickness | >500 nm per deposition cycle at 250 mm source-to-substrate distance |
| Deposition Rate | 1 nm/s (up to 10 nm/s) at 250 mm |
| Heating System | Ceramic crucible holder with integrated metal crucible |
| Temperature Range | 300 °C to 1700 °C |
| Power Supply | <10 V (typ. 9 V), <200 A (typ. 110 A), up to 2 kW |
| Cooling Water Flow | ~15 L/min |
| Optional Configurations | Ceramic or replaceable metal crucibles |
| Brand | UIC GmbH |
|---|---|
| Origin | Germany |
| Model | KDL10 |
| Feed Rate | 3–9 kg/h |
| Effective Evaporation Area | 0.1 m² |
| Evaporator Internal Diameter | 180 mm |
| Condenser Area | 0.18 m² |
| Collecting Flasks | 3 units |
| Construction Material | Borosilicate Glass 3.3, Nickel-Based Alloys, Tantalum Alloys |
| Max Evaporation Temperature | 300 °C |
| Min Operating Pressure | 0.001 mbar |
| Heating Method | Thermostatic Oil Bath |
| Film Formation | Self-Cleaning Roller-Type Wiper System |
| Evaporator Design | Modular Three-Zone Heated Assembly (Evaporation Zone, Residue Outlet Zone, Distillate Outlet Zone + Integrated Condenser) |
| Brand | GLOBUS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Range | Lab-Scale to Industrial-Scale |
| Ultrasonic Power | 3000 W |
| Ultrasonic Frequency | 24 / 38 kHz |
| Max Heating Power | 3000 W |
| Temperature Range | Ambient to 80 °C |
| Vessel Capacity | 2 – 250 L |
| Brand | STKJ |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TFE6-RC |
| Price | €500,000 |
| Feed Rate | 3–9 kg/h |
| Effective Evaporation Area | 0.08 m² |
| Evaporator Internal Diameter | 180 mm |
| Collecting Flasks | 3 |
| Condensation Area | 0.06 m² |
| Brand | UIC GmbH |
|---|---|
| Origin | Germany |
| Model | DSL 5 / KDL 5 |
| Feed Rate | 0.5–2.5 kg/h |
| Effective Evaporation Area | 0.05 m² |
| Evaporator Inner Diameter | 180 mm |
| Condenser Area | 0.085 m² |
| Collecting Flasks | 3 |
| Construction Material | Borosilicate Glass 3.3 |
| Max Evaporation Temp (DSL 5) | 250 °C |
| Max Evaporation Temp (KDL 5) | 350 °C |
| Min Operating Pressure (DSL 5) | 1 mbar |
| Min Operating Pressure (KDL 5) | 0.001 mbar |
| Film Formation | Self-Cleaning Roller System |
| Brand | UIC GmbH |
|---|---|
| Origin | Germany |
| Model | KD6 |
| Feed Rate | 3–9 kg/h |
| Effective Evaporation Area | 0.08 m² |
| Evaporator Internal Diameter | 180 mm |
| Condenser Area | 0.06 m² |
| Collecting Flasks | 3 |
| Max Operating Temperature | 350 °C |
| Min Operating Pressure | 0.001 mbar |
| Construction Material | Stainless Steel (optional: Hastelloy® upon request) |
| Heating Method | Independent Oil-Bath Heating for Evaporator Surface, Feed Line, Distillate Outlet, Residue Outlet, and Internal Condenser |
| Film Formation | Self-Cleaning Roller-Type Wiper System |
| Brand | SFT |
|---|---|
| Origin | USA |
| Model | SFT-250 |
| Max Operating Pressure | 10,000 PSI (68.9 MPa) |
| Max Temperature | 200 °C |
| Extraction Vessel Capacity | Up to 4 L |
| Flow Rate Range | 1–330 mL/min (1–310 g/min) |
| CO₂ & Co-solvent Flow Capability | Enhanced |
| Control Architecture | 4-channel analog PID loop control |
| Heating Power | 4 kW total |
| Safety | Rupture disc for liquid CO₂ overpressure protection |
| Heating Method | Band heaters on all vessels |
| Restriction Valve Heating | Up to 250 °C |
| External Heated Collection Tube | Stainless steel |
| Dimensions (L×W×H) | 92 × 61 × 76 cm |
| Weight (excl. vessels) | 64 kg |
| Electrical Requirement | Universal input |
| Drive Air Supply | ~80 psi (regulated, flow-dependent) |
| Brand | STKJ |
|---|---|
| Origin | Beijing, China |
| Model | SPDL1/2 |
| Feed Rate | 50–400 g/h |
| Effective Evaporation Area | 0.017 m² |
| Evaporator Inner Diameter | 120 mm |
| Condensation Area | 0.018 m² |
| Collecting Flasks | 3 (rotatable, continuous fraction collection) |
| Construction Material | Borosilicate Glass 3.3 |
| Max Evaporation Temperature | 250 °C |
| Min Operating Pressure | 0.001 mbar |
| Heating Method | Oil Bath |
| Film Formation | Self-Cleaning Roller Film System |
| Vacuum System | Dual-Stage Rotary Vane Pump with Integrated Vacuum Gauge |
| Brand | UIC GMBH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Multi-Stage System |
| Price | €500,000 |
| Feed Capacity | 50–20,000 kg/h |
| Effective Evaporation Area | 3–100 m² |
| Evaporator Internal Diameter | 300–800 mm |
| Condenser Area | 3–100 m² |
| Collecting Flasks | 3 |
| Brand | STKJ |
|---|---|
| Origin | Beijing, China |
| Model | SFT-120XW-D |
| Max Temperature | 250 °C |
| Max Pressure | 48 MPa |
| Extraction Volume Range | 5–1000 mL |
| Flow Control Resolution | 0.01 mL/min |
| Pressure Control Accuracy | ±1–2 psi |
| Pump Speed Range | 0–2500 rpm |
| Cooling Method | Electronic Refrigeration (pump head < −4 °C) |
| Reactor Options | Customizable single- or multi-vessel configurations up to 1000 mL total volume |
| Brand | UIC GmbH |
|---|---|
| Origin | Germany |
| Model | RF 4500 |
| Feed Rate | 50–20,000 kg/h |
| Effective Evaporation Area | 3–100 m² |
| Evaporator Internal Diameter | 300–800 mm |
| Condenser Area | 3–100 m² |
| Collection Vessels | 3 |
| Material of Construction | ASTM A240 316 stainless steel (standard), optional titanium or Hastelloy C-276 |
| Design Standard | AD-Merkblätter, ASME Section VIII Div. 1 (upon request) |
| Brand | Saite Technology (STKJ) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SFT-130A-E |
| Maximum Temperature | 200 °C |
| Extraction Vessel Volumes | 100 mL, 250 mL, 500 mL, 1000 mL |
| Maximum Operating Pressure | 48.3 MPa (7,000 psi) |
| CO₂ Flow Rate Range | Up to 500 mL/min (liquid CO₂ equivalent) |
| Brand | SFT |
|---|---|
| Origin | USA |
| Model | PM-II |
| Maximum Temperature | 150 °C |
| Number of Channels | 1 |
| Extraction Volume | 3–30 mL |
| Maximum Pressure | 10,000 psi (69 MPa) |
| Maximum Flow Rate | 0–24 mL/min |
| Extraction Capacity | 3–30 mL/h |
| Pressure Accuracy | ±2 psi |
| Temperature Accuracy | ±0.5 °C |
| Sample Cell Material | 316 Stainless Steel |
| View Window | 3/8″ Fused Quartz |
| Burst Disc Rating | 11,500 psi (79 MPa) |
| Compression Ratio | 10:1 |
| Heating Power | 500 W |
| Control | Fuzzy Logic Temperature Controller with RTD Feedback |
| Imaging System | 1/3″ Color CCD Camera with Variable-Focus Lens, Fiber-Optic Illumination, NTSC-Compatible Monitor & VCR Recording |