Empowering Scientific Discovery

Shanghai Chu Bai Laboratory Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTruelab
OriginShanghai, China
ModelUV-752
Wavelength Range200–1000 nm
Spectral Bandwidth4 nm
Wavelength Accuracy±2.0 nm
Wavelength Repeatability±1.0 nm
Stray Light≤0.5% T (at 220 nm and 340 nm)
Photometric Accuracy±0.5% T
Photometric Repeatability±0.2% T
Baseline Drift±0.003 A/h
DetectorPhotodiode Array
Optical DesignDual-Beam
Wavelength Resolution0.1 nm step
Display128×64 LCD
Dimensions456 × 375 × 220 mm
Data InterfaceUSB
SoftwareUV-Solution Workstation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOPOTOP
OriginShanghai, China
Model Series721, 722, 7230G, 723PC
Optical SystemDual-beam
Detector TypePhotodiode Array
Wavelength Range325–1100 nm (model-dependent)
Spectral Bandwidth2–5 nm
Wavelength Accuracy±1.0 nm (7230G & 723PC), ±2.0 nm (721 & 722)
Wavelength Repeatability0.5–1.0 nm
Stray Light≤0.2%T at 360 nm (723PC) to ≤0.5%T at 360 nm (721)
Photometric Accuracy±0.5%T (722/7230G/723PC), ±1.0%T (721)
Photometric Repeatability±0.2%T (722/7230G/723PC), ±0.5%T (721)
Baseline Linearity±0.004A (723PC only)
Stability±0.003A/h (7230G & 723PC), ±0.5%T/5min (721 & 722)
Display128×64 LCD
Dimensions456 × 375 × 220 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
ModelDR3900
Optical DesignSingle-beam (with reference compensation logic)
DetectorPhotodiode Array
Wavelength Range320–1100 nm
Wavelength Accuracy±1.5 nm (340–900 nm)
Spectral Bandwidth5 nm
Wavelength Repeatability<0.5 nm
Stray Light<0.05% T at 220 nm (KCl) and <0.1% T at 340 nm (NaNO₂)
Display7″ TFT WVGA Color Touchscreen (800 × 480 pixels)
Data Storage2000 measurement records (including sample ID, operator ID, date/time, result)
Preloaded Methods>220 EPA-, ISO-, and ASTM-compliant water quality methods
User MethodsUp to 100 custom programs
Barcode RecognitionAuto-identification of Hach TNTplus® and LCK vial barcodes
AQA ComplianceAutomated Quality Assurance workflow with scheduled verification, standard validation, interference testing, and audit-trail logging
ConnectivityDual USB ports (front/rear), 10/100 Mbps Ethernet, optional RS-232
Software IntegrationCompatible with Hach LINK2SC for bidirectional lab-to-field data synchronization and SC1000 controller correlation
Power Supply100–240 V AC, 50–60 Hz
Dimensions151 × 350 × 255 mm (W × D × H)
Weight4.2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMupuDa
OriginShanghai, China
ModelUV-6100
Optical SystemDual-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Spectral Bandwidth1.8 nm
Wavelength Accuracy±0.3 nm
Wavelength Repeatability≤0.1 nm
Stray Light≤0.03%T at 220 nm and 360 nm
Photometric Accuracy±0.002 A (0–0.5 A), ±0.004 A (0.5–1.0 A), ±0.2%T (0–100%T)
Photometric Repeatability≤0.001 A (0–0.5 A), ≤0.002 A (0.5–1.0 A), ≤0.15%T (0–100%T)
Baseline Drift±0.0003 A/h (at 500 nm, after warm-up)
Baseline Flatness±0.0005 A
Noise Level0.0003 Abs (at 500 nm)
Scan SpeedHigh/Medium/Low, up to 3800 nm/min
Photometric Range–4 to +4 A, 0–200%T, 0–9999 C
Display320 × 240 dot-matrix LCD
Data InterfaceUSB port, parallel printer port
Power SupplyAC 220 V/50 Hz or AC 110 V/60 Hz
Dimensions590 × 420 × 260 mm
Weight26 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTruelab
OriginShanghai, China
ModelUV-2800 / UV-2800PC
Optical DesignDual-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Spectral Bandwidth1.8 nm
Wavelength Accuracy±0.3 nm
Wavelength Repeatability±0.15 nm
Stray Light≤0.05% T
Baseline Flatness±0.001 A
Baseline Drift≤0.0005 A/h
Photometric Accuracy±0.3% T
Photometric Repeatability±0.15% T
Display320 × 240 LCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMapada
ModelUV-1800
Optical SystemSingle-beam
DetectorPhotodiode Array
Wavelength Range190–1100 nm
Spectral Bandwidth2 nm
Wavelength Accuracy±0.5 nm
Wavelength Repeatability≤0.2 nm
Stray Light≤0.05% T (at 220 nm and 360 nm)
Photometric Accuracy±0.002 A (0–0.5 A), ±0.004 A (0.5–1 A), ±0.3% T (0–100% T)
Photometric Repeatability≤0.001 A (0–0.5 A), ≤0.002 A (0.5–1 A), ≤0.15% T (0–100% T)
Baseline Drift±0.001 A/h (at 500 nm, after warm-up)
Baseline Flatness±0.002 A (200–1000 nm)
Noise Level0.0005 Abs (at 500 nm)
Photometric Range–0.3 to 3 A, 0–200% T, 0–9999 C
Light SourcesImported long-life deuterium lamp and tungsten-halogen lamp
Display128 × 64 dot-matrix LCD
Data InterfaceUSB port + parallel printer port
Dimensions490 × 360 × 240 mm
Weight14 kg