- All
- Favorite
- Popular
- Most rated
| Brand | HsiangTai |
|---|---|
| Origin | Taiwan |
| Model | HM-302 / HM-312 |
| Sample Capacity | 2 L |
| Output Power | 220 W DC |
| Speed Range | 500–12,000 rpm |
| Timer Range | 0–99 h 59 min (HM-312), Digital Speed & Time Display (HM-302) |
| Construction Material | SUS316 Stainless Steel Rotor-Stator Assembly |
| Drive Type | Variable-Speed DC Motor with Torque Compensation |
| Safety Features | Thermal Overload Protection, Fuse Protection |
| Dimensions (Overall) | 330 × 303 × 540 mm (W × L × H) |
| Weight | 10 kg |
| Input Voltage | AC 110 V / 220 V, 50 / 60 Hz |
| Brand | Silverson |
|---|---|
| Origin | United Kingdom |
| Model | L5T |
| Instrument Type | Probe-type Rotor-Stator Homogenizer |
| Dimensions (W×D×H) | 230 × 280 × 560 mm |
| Processing Volume Range | 1 mL – 12 L |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | T10 / T18 / T25 / T50 |
| Type | High-speed rotor-stator homogenizer |
| Power Input | 500 W (T18/T25), 600 W (T50) |
| Power Output | 300 W (T18), 360 W (T25), 500 W (T50) |
| Speed Range | 3,500–24,000 rpm (T10/T18), 3,000–25,000 rpm (T25), 500–10,000 rpm (T50) |
| Volume Range | 0.5–20 L |
| Max. Viscosity | 5,000 mPa·s |
| Dimensions (W×D×H) | 65 × 80 × 240 mm (T10/T18/T25), 120 × 140 × 420 mm (T50) |
| Weight | 1.6 kg (T10/T18/T25), 6.2 kg (T50) |
| Noise Level | ≤73 dB(A) (T18 at max speed) |
| Drive System | Brushless DC motor with electronic speed & temperature control |
| Safety | Electronic overtemperature protection, automatic restart inhibition after thermal shutdown |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | IKA T25 Basic Kit |
| Drive Type | High-Speed Rotational (Rotor-Stator) |
| Dimensions (W×D×H) | 65 × 240 × 80 mm |
| Processing Volume Range | 1–2000 mL (H₂O) |
| Motor Input Power | 500 W |
| Motor Output Power | 300 W |
| Speed Range | 6,500–24,000 rpm |
| Speed Accuracy | ±1% |
| Max. Viscosity | 5,000 mPa·s |
| Shaft Diameter | 13 mm |
| Shaft Length | 175 mm |
| Weight | 1.6 kg |
| Protection Class | IP20 (DIN EN 60529) |
| Operating Ambient | 5–40 °C, ≤80% RH |
| Power Supply | 230/115 V, 50/60 Hz |
| Noise Level (no head) | 73 dB(A) |
| Brand | Truelab |
|---|---|
| Origin | Tianjin, China |
| Instrument Type | High-Pressure Inline Homogenizer |
| Model | HFJ-10 |
| Dimensions (W×D×H) | 280 × 440 × 260 mm |
| Processing Capacity | 500–5000 mL |
| Rotational Speed Range | HFJ-10: 5000–35,000 rpm |
| HFJ-18 & HFJ-25 | 10,000–31,000 rpm |
| Probe Diameter | Φ10 mm (HFJ-10), Φ18 mm (HFJ-18), Φ25 mm (HFJ-25) |
| Output Power | 200 W (HFJ-10), 550 W (HFJ-18 & HFJ-25) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | T18 ULTRA-TURRAX |
| Instrument Type | Probe-type rotor-stator homogenizer |
| Dimensions (W×D×H) | 65 × 80 × 240 mm |
| Processing Volume Range | 10–1500 mL |
| Motor Input Power | 500 W |
| Motor Output Power | 300 W |
| Max. Viscosity | 5,000 mPa·s |
| No-Load Noise Level | 73 dB(A) |
| Weight | 1.6 kg |
| Speed Range | 3,500–24,000 rpm (infinitely variable, calibrated scale) |
| Shaft Diameter/Length | 13 mm / 175 mm |
| Compatible Probes | S18N-10G (1–100 mL), S18N-19G (10–1500 mL) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | BM-400HP |
| Instrument Type | Pulsed-Action (Stomacher-Type) Homogenizer |
| Dimensions (W×D×H) | 390 × 220 × 310 mm |
| Sample Volume Range | 10–400 mL |
| Temperature Control Range | Ambient to 50 °C |
| Pulsing Frequency | 3–12 pulses/s (adjustable in 0.1 increments) |
| Stroke Length | 0–40 mm (adjustable) |
| Timer Range | 0–100 min (0.1-min resolution) or Continuous Mode |
| UV Sterilization | 254 nm, 5 min per cycle |
| Display | Large LCD with Digital Keypad Interface |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 300 W |
| Net Weight | 21 kg |
| Program Memory | 10 user-defined protocols |
| Safety Features | Auto-stop door interlock, tempered glass viewing window, integrated waste collection tray |
| Construction | Full stainless-steel housing |
| Compliance | Designed for ISO 6887-1, ASTM D5659, and USP <61> microbiological sample preparation workflows |
| Brand | HsiangTai (HSIANGTAI) |
|---|---|
| Origin | Taiwan |
| Model | HMB-306 / HMB-312 |
| Sample Capacity | 2 L |
| Output Power | 150 W DC |
| Speed Range | 0–6,000 rpm (HMB-306), 0–12,000 rpm (HMB-312) |
| Torque | 2.5 kgf·cm / 0.25 N·m |
| Timer Range | 0–99 h 59 min |
| Dimensions (Overall) | 330 × 303 × 540 mm |
| Weight | 13 kg |
| Input Voltage | AC 110 V / 220 V, 50 / 60 Hz |
| Homogenizing Head Material | ASTM A276 Type 316 Stainless Steel |
| Safety Protection | Overload, Overheat, and Fuse Circuit Protection |
| Brand | Interscience |
|---|---|
| Origin | France |
| Model | 400 CC |
| Instrument Type | Paddle-Blade (Stomacher-Style) |
| Dimensions (W×D×H) | 370 × 210 × 200 mm |
| Sample Volume Range | 5–80 mL |
| Operating Frequency | 4, 6, 8, or 10 impacts/sec |
| Homogenization Time Range | 1 s to 60 min (or continuous mode) |
| Net Weight | 13 kg |
| Power Supply | 110/220 V, 50/60 Hz |
| Construction | Full Stainless Steel Housing |
| Door Opening Angle | 270° |
| Sealing System | Q-Tight® patented bag retention mechanism |
| Safety Features | Integrated drip tray, shock-absorbing feet, reinforced viewing window |
| Brand | HsiangTai |
|---|---|
| Origin | Taiwan |
| Model | HM-402 |
| Instrument Type | Benchtop Homogenizer |
| Sample Processing Volume | 2 L |
| Output Power | 350 W DC Motor |
| Speed Range | 200–7,000 rpm |
| Max. Torque | 5.4 kgf·cm / 0.53 N·m |
| Dimensions (W × L × H) | 530 × 450 × 950 mm |
| Drive Type | Digital-Controlled Brushless DC Motor |
| Lift Mechanism | Pneumatic-Assisted Vertical Adjustment |
| Safety Features | Thermal Overload Protection, Integrated Fuse, Vibration-Damped Base |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | T50 Basic |
| Motor Input Power | 1100 W |
| Motor Output Power | 700 W |
| Speed Range | 4,000–10,000 rpm |
| Speed Accuracy | ±1% |
| Max. Processing Volume (H₂O) | 30 L |
| Min. Processing Volume (H₂O) | 0.25 L |
| Max. Viscosity | 5,000 mPa·s |
| Noise Level (no dispersing tool) | 72 dB(A) |
| Dimensions (W×D×H) | 125 × 367 × 120 mm |
| Weight | 6 kg |
| Protection Class | IP20 (DIN EN 60529) |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% |
| Voltage | 230/115 V |
| Frequency | 50/60 Hz |
| Shaft Extension Diameter | 16 mm |
| Shaft Extension Length | 220 mm |
| Drive Type | Batch processing |
| Speed Display | Analog scale |
| Speed Control | Continuous (infinitely variable) |
| Torque-Speed Coupling | Integrated for viscosity compensation |
| Bearing System | Triple-bearing drive shaft |
| Tool Mounting | Insert-type quick-connect |
| Safety Circuit | Electronic soft-start protection |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | BM-400 |
| Instrument Type | Stomacher-type |
| Dimensions (W×D×H) | 390 × 220 × 310 mm |
| Sample Volume Range | 10–400 mL |
| Control Method | Digital Microprocessor |
| Display | Large LCD Screen |
| Timer Range | 0–100.0 min (or continuous mode) |
| Pulsing Frequency | 3.0–12.0 cycles/sec (adjustable) |
| Stroke Length | 0–40 mm (adjustable) |
| UV Sterilization | 254 nm, 5 min per cycle (BM-400P & BM-400HP only) |
| Temperature Control Range | Ambient to 50 °C (BM-400HP only) |
| Program Storage | 10 user-defined protocols |
| Power Consumption | 300 W |
| Electrical Supply | 220 V / 50 Hz |
| Net Weight | 21 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | IKA T10 Basic Kit |
| Motor Input Power | 125 W |
| Motor Output Power | 75 W |
| Speed Range | 8,000–30,000 rpm |
| Speed Control | Continuously Variable |
| Display | Analog Speed Scale |
| Max. Capacity (H₂O) | 0.1 L |
| Min. Capacity (H₂O) | 0.5 mL |
| Max. Viscosity | 5,000 mPa·s |
| Noise Level (no dispersing element) | 65 dB(A) |
| Dimensions (W×D×H) | 46 × 201 × 57 mm |
| Weight | 0.4 kg |
| IP Rating | IP30 |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80 % |
| Voltage | 230 / 115 / 100 V |
| Frequency | 50/60 Hz |
| Duty Cycle | 10 min ON / 5 min OFF |
| Shaft Diameter | 8 mm |
| Shaft Length | 100 mm |
| Process Type | Batch |
| Dispersing Elements | Stainless Steel (Ø5 mm, Ø8 mm, Ø10 mm) & Disposable Plastic (KS 65, KS 110) |
| Compliance | DIN EN 60529, IEC 61000-6-3, IEC 61000-6-2 |
| Brand | Silverson |
|---|---|
| Origin | United Kingdom |
| Model | L5M-A |
| Instrument Type | Rotor-Stator Probe-Type Homogenizer |
| Dimensions (W×D×H) | 940 × 305 × 508 mm |
| Processing Volume Range | 1 mL to 12 L |
Show next