| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J90 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 420 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 32 GB internal SSD |
| Image/Video Storage | Up to 1,000 frames + 80 complete melting profiles |
| User Accounts | 20 configurable roles with password protection |
| Operating Interface | 7-inch TFT full-color touchscreen |
| Connectivity | USB 2.0, RS-232, Ethernet |
| Optical Magnification | 7× |
| Integrated Thermal Printer | Yes |
| Reference Standard Set Included | Yes |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J80 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min ramp rate |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 16 GB internal |
| Melting Curve Records | 600 traces |
| Video Recordings Stored | 20 full sequences |
| User Accounts | 10 configurable profiles |
| Imaging | High-definition CMOS video module (7× optical magnification) |
| Display | TFT true-color touchscreen |
| Connectivity | USB, RS-232, Ethernet |
| Power | 220 V AC, 50 Hz, 120 W |
| Operating Modes | Fully automated + manual override |
| Preloaded Methods | 40 validated protocols |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI 8751 / HI 8757 |
| Temperature Range (HI 8751) | –40.0 to +150.0 °C |
| Temperature Range (HI 8757) | –50.0 to +199.0 °C and +200 to +1350 °C |
| Sensor Type | HI 8751 — Precision Silicon RTD Probe (HI765PW) |
| Accuracy (HI 8751) | ±0.2 °C (–10.0 to +80.0 °C) |
| Accuracy (HI 8757) | ±1.0 °C or ±0.75% of reading (whichever is greater) |
| Resolution | 0.1 °C (–50.0 to +999.9 °C), 1 °C above 1000 °C |
| Power | 9 V alkaline battery (included) |
| Housing | ABS plastic (HI 8751), IP65-rated ABS with stainless steel probe (HI 8757) |
| Compliance | CE, RoHS, EN 61326-1 (EMC for laboratory equipment) |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | JHD70 |
| Price Range | USD 4,200 – 7,000 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Sample Capacity | 4 capillaries per run (2 simultaneously analyzed) |
| Display | Dual-color LCD (3.5″ + 5.6″), >2.5× optical magnification |
| User Accounts | 15 |
| Predefined Methods | 100 |
| Data Interfaces | USB, RS232, Ethernet |
| GLP Compliance | Yes |
| Power Supply | 220 V, 50 Hz, 120 W |
| Standards Compliance | ASTM D3204, D3461, D3954, D6090 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | JH50, JH70, JH90 |
| Temperature Range | RT to 350 °C |
| Heating Rate | 0.1–20 °C/min (200-step adjustable) |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per batch |
| Display | TFT high-definition color LCD |
| Data Storage | 8 GB internal |
| Image Capture | Still frame capture with real-time video streaming |
| Video Playback | Local playback supported |
| Connectivity | USB, RS-232, Ethernet |
| Power Supply | 220 VAC, 50 Hz, 120 W |
| Magnification | 7× optical |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI 146-00 / HI 151-00 |
| Instrument Type | Wall-Mounted Digital Thermohygrometer |
| Probe Type | Stainless Steel Needle Probe (HI 146-00) |
| Display | LCD |
| Power | 1 × 1.5 V AAA battery |
| Calibration Verification | Built-in self-test mode (READ/TEST switch) |
| Compliance | Designed for HACCP, ISO 22000, and FDA Food Code-compliant environments |
| Sample Contact | Air, gases, liquids, semi-solids, frozen foods |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | D-1A |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Temperature Range | Ambient to 300°C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min |
| Temperature Repeatability | ±0.5°C at <200°C |
| Temperature Accuracy | ±0.1°C (calibrated against NIST-traceable reference) |
| Temperature Resolution | 0.1°C |
| Instrument Weight | 11 kg |
| Compliance | GB/T 8728–1988, ASTM E342, ASTM D36, ISO 4625, DIN 51801 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SCY-3 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Detection Range | 0–2% (displayed as % vol when ≥1% |
| Accuracy | ±1.0% of full scale |
| Operating Temperature | 0–45 °C |
| Relative Humidity Limit | <90% RH (non-condensing) |
| Interference Restrictions | Excludes CH₄, SO₂, H₂S, Cl₂, NH₃, and other corrosive or spectrally overlapping gases |
| Power Supply | AC 220 V, 50–60 Hz / DC 12 V (rechargeable Ni-MH battery onboard) |
| Power Consumption | ≤3 W (DC mode) |
| Dimensions | 210 × 90 × 230 mm |
| Weight | 2.0 kg |
| Response Time (t₉₀) | ≤50 s |
| Display | Backlit Chinese-language LCD |
| Data Output | Integrated thermal printer (real-time printout of measurement records) |
| Auto-Sampling Interval | Programmable timed measurement cycles |
| Compliance | Designed per IEC 61000-6-3 (EMC), GB/T 18204.2–2014 (Chinese standard for CO₂ detection in indoor air), and general industrial safety requirements for portable gas analyzers |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | LHH-800SD |
| Temperature Range | 0–65 °C |
| Max Operating Temperature | ≤150 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | ±2 °C |
| Temperature Deviation | ±2 °C |
| Ramp-up Time (to 65 °C) | 20 min |
| Internal Chamber Dimensions (W×H×D) | 965×1430×580 mm |
| Humidity Range | 40–90 %RH |
| Humidity Accuracy | ±3 %RH |
| Illumination Control | Optional (0–6000 lx, stepless adjustment) |
| Refrigeration System | Dual independent imported hermetic compressors with auto-switching logic |
| Controller Type | Programmable touchscreen (SDP/GSP series), LCD display (SD/GSD series) |
| Sensor Types | Pt100 RTD (temperature), capacitive humidity sensor |
| Compliance Support | IQ/OQ/PQ validation documentation available |
| Power Supply | AC 220 V / 50 Hz or AC 380 V / 50 Hz |
| Safety Protections | Over-temperature, compressor overheat/overpressure, fan overheat, overload, low-water, audible/visual alarms |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-8S |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 0.1–2,000,000 mPa·s (with appropriate spindle and speed selection) |
| Speed Settings | 6, 12, 30, 60 rpm |
| Spindles | LV#1–#4 (standard set) |
| Display | Digital LCD with bilingual (English/Chinese) interface |
| Measurement Accuracy (Newtonian fluids) | ±5% of full scale |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | Ambient temperature (10–35 °C), <80% RH non-condensing |
| Compliance | Designed per GB/T 2794–2013 (China National Standard for viscometer calibration), compatible with ISO 2555 and ASTM D2196 test methodologies |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Y50 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–10 °C/min |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Accuracy | ±0.3 °C (at ~100 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, L 100 mm (dual-open) |
| Sample Capacity | 2 samples per run |
| Temperature Resolution | 0.1 °C |
| Cooling Method | Forced-air convection |
| Display | 7-inch TFT high-definition color screen |
| Data Storage | 8 GB internal + microSD card (up to 128 GB) |
| Connectivity | USB 2.0, RS-232, Ethernet |
| User Accounts | 8 configurable roles with password protection |
| Compliance Standards | SNT 0801.5–1999, GB/T 24892–2010, GB/T 12766–2008 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NDJ-1 Ultra-Low Viscosity |
| Instrument Type | Benchtop Fixed Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.1–2,000,000 mPa·s |
| Speed Settings | 6, 12, 30, 60 rpm (manual gear shift) |
| Accuracy | ±5% (for Newtonian fluids) |
| Spindle Set | #0, #1, #2, #3, #4 |
| Gear Ratio Units | I (1:1), II (1:10, 1:100), III (×0.1, ×0.2, ×0.4, ×0.5) |
| Power Supply | 220 V AC, 50 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Y30 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–10 °C/min |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min heating rate) |
| Temperature Accuracy | ±0.3 °C (up to 100 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, L 100 mm (dual-open) |
| Sample Capacity | 2 samples per run |
| Temperature Resolution | 0.1 °C |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BT-2 |
| Instrument Type | Digital Thermo-Hygrometer |
| Temperature Range (Internal) | –30 °C to +50 °C (–22 °F to +122 °F) |
| Temperature Range (External Probe) | –50 °C to +70 °C (–58 °F to +158 °F) |
| Humidity Range | 20–99% RH |
| Temperature Resolution | 0.1 °C/°F |
| Humidity Resolution | 1% RH |
| Temperature Accuracy | ±1 °C |
| Humidity Accuracy | ±5% RH (at 25 °C) |
| Power Supply | 1 × 1.5 V AAA alkaline battery (included) |
| Dimensions (H×W×D) | 111 × 101 × 21.5 mm |
| Display Area | 81.5 × 64.5 mm |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J30 |
| Price | USD 1,650 (FOB Shanghai) |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (≥250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 positions |
| Temperature Resolution | 0.1 °C |
| Display | 7-inch TFT true-color LCD |
| Data Storage | 200 test records (8 GB internal flash) |
| Video Magnification | 7× |
| Interface | USB 2.0, RS-232, 10/100 Mbps Ethernet |
| Power Supply | 220 V AC, 50 Hz, 120 W |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J50 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Storage | 8 GB internal flash memory |
| Data Storage Capacity | Up to 400 melting thermograms |
| Imaging | HD video capture module with 7× optical magnification |
| Display | TFT high-definition color touchscreen |
| Power Supply | 220 V AC, 50 Hz, 120 W |
| Interfaces | USB, RS-232, Ethernet |
| Operation Mode | Semi-automatic (automated temperature control, manual endpoint detection) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Y90 |
| Price Range | USD 1,400–2,800 |
| Temperature Range | 4–100 °C |
| Heating Rate | 0.1–10 °C/min |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Accuracy | ±0.3 °C (up to 100 °C) |
| Capillary Dimensions | OD 4 mm, ID 1.0 mm, L 100 mm (dual-open) |
| Sample Capacity | 2 samples per run |
| Temperature Resolution | 0.1 °C |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKF115, MK115, MKT115 |
| Temperature Range | -70 °C to +180 °C |
| Thermal Shock Range | -70 °C to +180 °C |
| Temperature Stability | ±0.1 °C to ±0.6 °C |
| Heating Rate | 5.3 °C/min |
| Cooling Rate | 4.2 °C/min |
| Humidity Control (MKF/MKFT only) | 10–98 % RH |
| Integrated Water Reservoir | 20 L |
| Programmable Condensation Protection | Yes |
| APT.line™ Preheating Technology | Standard |
| MCS Controller with 4 Zero-Voltage Switch Outputs | Standard |
| Heated & LED-Illuminated Viewing Window | Standard |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J70 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 8 GB internal flash |
| Image Storage | 400 frames |
| Video Recording | Yes (TFT-displayed real-time capture) |
| User Accounts | 8 configurable profiles |
| Display | TFT high-definition true-color LCD |
| Interface | USB, RS-232, Ethernet |
| Power | 220 V AC, 50 Hz, 120 W |
| Magnification | 7× optical |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LVDV-C |
| Instrument Type | Portable Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–2,000,000 mPa·s (cP) |
| Speed Settings | 18 programmable RPM |
| Accuracy | ±0.1% of full scale |
| Repeatability | ±0.2% |
| Torque Display | % torque, cP, and mPa·s directly readable |
| Sensor Architecture | High-density torsion transducer with 4 sensing points per revolution |
| Calibration | Individual rotor calibration |
| Compliance | Designed to support ASTM D2196, ISO 2555, ISO 3219, and USP <911> viscosity testing protocols |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LND-2 |
| Instrument Category | Efflux Viscometer |
| Mounting Type | Benchtop Fixed |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 30–100 s (efflux time) |
| Temperature Range | 20–25 °C (standard test condition) |
| Temperature Resolution | Not applicable (non-temperature-controlled) |
| Temperature Accuracy | Not applicable (non-temperature-controlled) |
| Calibration Standards | ASTM D1200, ISO 2431, GB/T 1723–1993 |
| Measurement Error | ±3% of reading |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | Y70 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–10 °C/min |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Accuracy | ±0.3 °C (up to 100 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, L 100 mm (dual-open) |
| Sample Capacity | 2 samples per run |
| Temperature Resolution | 0.1 °C |
| Compliance | SNT 0801.5–1999, GB/T 24892–2010, GB/T 12766–2008 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-79 |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–1×10⁶ mPa·s |
| Accuracy | ±5% (for Newtonian fluids) |
| Rotational Speeds | 7.5 / 75 / 750 rpm |
| Measuring Systems | Three interchangeable spindles (Units I, II, III) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions | 170 × 140 × 440 mm |
| Weight | 15 kg |
| Operating Environment | Ambient temperature (no integrated temperature control) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SCY-3A |
| Measurement Range | 0–1.5% (w/w) |
| Accuracy | ±2.5% |
| Display | Chinese LCD interface |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | ≤15 W |
| Dimensions | 450 mm × 305 mm × 550 mm (H) |
| Weight | 15 kg |
| Data Storage Capacity | 63 entries per sample type (beer + soft drinks) |