- All
- Favorite
- Popular
- Most rated
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | WI22-0201 Octo-Configurable Kit |
| Price Range | USD 0.15 – 150.00 |
| Material | 316L Stainless Steel (Needles & Housing), Medical-Grade Polypropylene (Adapters) |
| Certifications | ISO 13485–compatible manufacturing environment |
| Pressure Test | Pre-shipped hydrostatic leak test at 0.6 MPa |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Model | FarinoGraph E-300 |
| Compliance | ISO 5530-1, ISO 5530-2, AACCI 54-22.01, ICC 114/1, GB/T 14614, DIN EN ISO 5530-1 |
| Torque Range | Up to 28 N·m |
| Measurement Duration | 0–200 min |
| Power Supply | 230 V (184–264 V) / 50–60 Hz, 1 kW or 115 V (88–126 V) / 50–60 Hz, 1 kW |
| Dimensions (W×H×D) | 430 × 630 × 740 mm |
| Weight (without mixer) | 56 kg |
| Weight (with S300 mixer) | 74 kg |
| Interfaces | 4× USB, 1× HDMI, 2× Ethernet |
| Software | MetaBridge v3.x with AI-assisted curve interpretation and audit-trail-enabled data management |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | MBE-1 |
| Power Supply Compatibility | DC high-voltage source (0–30 kV) |
| Syringe Pump Interface | Standard Luer-lock input |
| Grounding Options | Adjustable 6 cm / 8 cm / 10 cm metallic grounding rings |
| Base Dimensions | 300 × 200 mm |
| Structural Material | Polypropylene insulating frame with grounded square metal plate |
| Needle Mounting | X–Z manual translation stage |
| Compatible Nozzle Configurations | Single-, coaxial-, and triaxial needle assemblies |
| Safety Features | Interlocked protective hood, dedicated HV terminal mounting holes, ESD-safe base architecture |
| Regulatory Alignment | Designed to support GLP-compliant process documentation and ASTM D7945-15 (electrospinning/electrospray methodology guidelines) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RRC-1 |
| Price | USD 1,400 (approx.) |
| Base Web Width | 100 mm |
| Speed Range | 0.01–10 rpm |
| Linear Velocity Range | 0.13–52.44 mm/s |
| Drum Diameter Compatibility | 25–100 mm |
| Roller Height Adjustment | 0–24 mm |
| Max Power Consumption | 45 W |
| Supply Voltage | 24 V DC |
| Frame Material | PP Polypropylene |
| Roller & Mount | 304 Stainless Steel |
| Grounding Plate | Anodized Aluminum |
| Net Weight | 7.5 kg |
| Cable | 1 m, 5-pin aviation connector |
| Operating Temperature | 5–45 °C |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SmartFiber-E |
| Price | USD 5,600 (FOB Shanghai) |
| Compliance | GB/T 5009.88–2008, GB/T 5413.6–2010, GB/T 9822–2008, GB/T 22494–2008, NY/T 1594–2008, AOAC 991.43, AACC 32–07, NMKL 157, ASP Method |
| Sample Throughput | 6 samples per run |
| Filtration Technology | Dual-mode SmartVacuumFilter™ with alternating positive/negative pressure |
| Crucible Type | Patented ground-glass fritted crucibles (G2, 40–100 µm pore size) |
| Filtration Speed | ≤3 min per 100 mL digestate |
| Precision | RSD <0.5% (n=6, certified reference material) |
| Software | Standalone control interface with audit trail logging |
| Accessories | G1–G5 fritted crucibles, 80–2800 mesh sieves, optional thermostatic shaker bath, standardized clamp kits |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | LHH-SS-I |
| Temperature Range | 0–65 °C (10–65 °C with illumination) |
| Humidity Range | 40–95 %RH |
| Temperature Uniformity | ±2 °C |
| Temperature Fluctuation | ±0.4 °C |
| Humidity Deviation | ±2–3 %RH |
| Illuminance Control | 0–6000 lx (adjustable, error ≤ ±500 lx) |
| Chamber Configuration | Dual independent chambers (100 L + 100 L) |
| Refrigeration System | Dual imported hermetic compressors with auto-switching redundancy |
| Humidity Sensing | Imported capacitive humidity sensor |
| Interior Material | Electropolished stainless steel with radius-corner design |
| Controller | Graphical LCD touchscreen with real-time trend plotting |
| Compliance Support | IQ/OQ/PQ documentation and calibration services available |
| Optional Accessories | Wired/remote alarm systems, UV sterilization module, illuminance auto-regulation, paperless data loggers (e.g., Fuji PE-2), third-party metrology validation report (Shanghai Metrology Institute) |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Viscograph-E |
| Price | USD 135,000 (FOB Hamburg) |
| [Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | LHH Series |
| Internal Volume | 2–250 m³ (customizable) |
| Temperature Range | 0–65°C |
| Humidity Range | 40–95% RH (down to ≤20% RH with optional dehumidification) |
| Temp. Uniformity | ≤±2.0°C |
| Temp. Fluctuation | ±0.5°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | 1–2°C/min |
| Cooling Rate | 0.5–1°C/min |
| Control System | BTHC (Balanced Temperature & Humidity Control) with PID algorithm |
| Display | Color TFT LCD touchscreen (Chinese/English switchable) |
| Programs | Up to 100 user-defined/storable cycles |
| Sensor Inputs | PT100 (temperature), capacitive humidity sensor |
| Communication | RS-232C, RS-485 |
| Power Supply | AC 380 V ±10%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Operating Ambient | +5 to +35°C |
| Compliance Support | IQ/OQ/PQ qualification packages available |
| Optional Accessories | UV sterilization module, programmable light intensity control (0–10,000 lux), wired/wireless alarm systems, USB/RS-485 data logging, third-party metrology report (Shanghai Accredited Lab, ¥1500)] |
| Brand | Truelab |
|---|---|
| Output Voltage Range | 0 to –3,000 V DC |
| Voltage Resolution | ±2 V |
| Load Regulation | < 0.05% |
| Temperature Drift | < 0.05%/°C |
| Time Drift | < 0.05%/h |
| Display | 4-digit voltage LED, 3-digit current LED |
| Grounding | Common-ground configuration (compatible with positive HV supply) |
| Protection | Auto-recovery shutdown |
| Control | Analog rotary potentiometer for precise voltage setting |
| Operating Temperature | 0–65 °C |
| Operating Humidity | 20–90% RH (non-condensing) |
| Dimensions (W×H×D) | 200 × 95 × 300 mm |
| Weight | 2.8 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PEC-1 |
| Price Range | USD 125 – 140 |
| Electrode Spacing | 0–80 mm |
| Electrode Length | 100 mm |
| Electrode Width | 10 mm |
| Overall Dimensions (L×W×H) | 120 × 120 × 90 mm |
| Electrode Material | Oxygen-Free Copper (OFHC) |
| Electrode Holder & Base Material | Polypropylene (PP) |
| Surface Finish | Sharp-edged collection faces |
| Alignment Tolerance | < 0.1° deviation over full length |
| Weight | ~1.3 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JSY-1 |
| Price Range | USD 0.14 – 1,430 (FOB) |
| Collection Drum Speed | 0.01–10 rpm |
| Reciprocating Stroke | 50 mm |
| Reciprocating Speed | 0.01–10 mm/s |
| Water Bath Dimensions (W×D×H) | 220 × 145 × 65 mm |
| Grounding Method | Alligator Clip |
| Water Bath Material | AISI 304 Stainless Steel |
| Base & Enclosure Material | Polypropylene (PP) |
| Support Frame Material | AISI 304 Stainless Steel |
| Net Weight | 3.5 kg (water bath only, empty, excluding control box) |
| Cable Length | 1.5 m (aviation connector) |
| Operating Temperature Range | 5–45 °C |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NMS-1 |
| Price Range | USD 1,400 – 2,800 |
| Funnel Diameter | 60 mm |
| Funnel Speed Range | 0–650 rpm |
| Winding Drum Speed | 0.01–10 rpm |
| Reciprocating Stroke | ≤50 mm |
| Reciprocating Speed | 0.01–10 mm/s |
| Yarn Component Width | 100 mm |
| Max. Yarn Spool Diameter | 100 mm |
| Weight | 4 kg |
| Max. Power Consumption | 45 W |
| Supply Voltage | 24 V DC |
| Operating Temperature | 5–45 °C |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Model | Extensograph |
| Sample Mass | 300 g flour + 6 g salt + distilled water |
| Dough Kneading Speed | 83 ±3 rpm |
| Resting Time | 15 ±1 min |
| Stretching Speed | 14.5 ±0.5 mm/s |
| Maximum Extension Length | 680 mm |
| Measurement Range | 0–2,000 EU/BU |
| Fermentation Temperature Control | 30 °C (adjustable, with ambient compensation up to 40 °C) |
| Humidity Control | Ultrasonic humidification system |
| Dimensions (W × H × D) | 840 × 720 × 500 mm |
| Weight | ~115 kg |
| Power Supply | 100–240 V, 50/60 Hz, 0.24 kW |
| Interfaces | USB (4), LAN/Ethernet (2), HDMI (1) |
| Compliance Standards | ISO 5530-2, DIN EN ISO 5530-2, CEN EN ISO 5530-2, AACC 54-10.01, ICC Standard 114/1, GB/T 14615, GB/T 35994, NF V03-717-2, OENORM EN ISO 5530-2, SN EN ISO 5530-2, BS EN ISO 5530-2, UNE-EN ISO 5530-2, IRAM 15856, TCVN 7848-2, AGSA 06-01, CCAT 03 & 16 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | HC01-0101 |
| Power Supply | 24 V DC |
| Rated Power | 120 W |
| Rotational Speed Range | 120–3600 rpm |
| Dimensions (L×W×H) | 450 × 450 × 450 mm |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | TES-4 |
| Voltage Output | ±30 kV (standard), optional ±60 kV |
| Collector | 304 stainless steel roller, servo-driven, max. 3000 rpm |
| Syringe Pump | Dual-channel, 2–60 mL compatibility, high-voltage rated |
| Motion Control | X (280 mm, manual), Y (180 mm auto-reciprocating, up to 3000 mm/min), Z (100 mm, manual) |
| Environmental Control | PID-controlled heating (far-infrared), condensation dehumidification, thermal evaporation humidification |
| Safety | Emergency stop, grounded conductive structure, explosion-proof tempered glass viewport, anti-static floor mat, UV germicidal lamp, observation lamp |
| Compliance | Designed for GLP-compliant electrospinning R&D environments |
| Software | Proprietary PLC-based electrospinning OS with real-time environmental logging, parameter recall, and audit-ready operation history |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SLQ-6 |
| Sample Capacity | 6 positions |
| Sample Mass Range | 0.5–3 g |
| Measurement Range | 0–100% (w/w) |
| Accuracy | Relative deviation ≤4%, Parallel deviation ≤0.4% |
| Total Cycle Time | ≤90 min (acid digestion: 30 min, alkaline digestion: 30 min, filtration & rinsing: ~30 min) |
| Heating System | Six independent semi-spherical ceramic heating elements with individual temperature control per crucible |
| Temperature Range | Ambient to 400 °C |
| Sealing Mechanism | Dual-layer PTFE isolation gasket (top and bottom) |
| Rated Power | 2 kW |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Dimensions (W×D×H) | 570 × 470 × 750 mm |
| Weight | 30 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SZPT-3P |
| Material | 316L stainless steel (needle body & seat), medical-grade polypropylene (Luer adapter) |
| Dead Volume | Outer-Middle layer: 1.4 mL |
| Middle-Inner layer | 2.0 mL |
| Inner layer | 0.2 mL |
| Weight | ~300 g |
| Configurable needle gauges | e.g., 13G+16G+20G, 13G+18G+25G, 15G+20G+25G |
| Includes | 1× modular needle seat, 3× triple-needle sets, 10× 1/16″ tubing fittings, 10× small O-rings, 4× large O-rings, 4× Luer-lock adapters, 1× dual-purpose wrench, 1× metal mounting bracket |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TES-1 |
| Price Range | USD 2,800 – 7,000 |
| High-Voltage Power Supply | 0–+30 kV (adjustable), optional −30 kV |
| Dual-Channel Syringe Pump | 100 µL/h – 7.62 L/h, supports 1–60 mL syringes |
| Needle Traverse Range | 0–150 mm |
| Needle Speed | 0–1000 ±1 mm/min |
| Collector Rotation Speed | 120–3000 ±20 rpm (bidirectional) |
| Standard Collector | Balanced Rotating Drum (Φ100 × L200 mm) |
| Overall Dimensions (w/o collector) | 471 × 455 × 518 mm |
| Weight (w/o collector) | 25 kg |
| Safety Features | Emergency Stop, Grounding Protection, Overvoltage/Overcurrent/Arc-Fault Protection |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 60 W |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | TES-2 |
| Power Supply | ±30.0 kV (0.1 kV resolution) |
| Dual-Channel Syringe Pump | 100 µL/h – 7.62 L/h, max 60 mL syringe |
| Collector Speed | 0–600 ±1 rpm, reversible |
| Nozzle Traverse Range | 40–200 mm |
| Nozzle Travel Speed | 0–1000 ±1 mm/min |
| Tip-to-Collector Gap Adjustment | up to 180 mm |
| Temperature Control | RT–50 ±1.0 °C |
| Humidity Control | 20–80 ±3 %RH |
| Chamber Dimensions (w/d/h) | 833×466×995 mm (standalone), 833×466×1800 mm (with mobile base) |
| Weight | 110 kg (standalone), 125 kg (with base) |
| Total Power Consumption | 625 W |
| Safety Compliance | Integrated emergency stop, interlocked access door, full-system grounding, overtemperature protection, ESD-safe materials (PFA tubing, anti-static polymers, carbon-brush grounding rods) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EAB1-2000 / EAB1-95 |
| Price | USD 1,020 (FOB Shanghai) |
| Instrument Category | Aflatoxin B1 Quantification System |
| Detection Principle | Solid-Phase Enzyme-Linked Immunosorbent Assay (ELISA) |
| Wavelength | 450 ± 2 nm (standard interference filter) |
| Absorbance Range | –0.041 to 1.999 A |
| Detection Limit | 0.1 ng/mL |
| Quantitative Range | 0.1–1.0 ng/mL (ppb) |
| Sensitivity | < 0.1 ng/mL |
| Accuracy | ±0.1 ng/mL |
| Throughput | 20 samples/hour |
| Light Source | LED (3.6 V / 20 mA) |
| Operating Environment | 5–35 °C, ≤85% RH |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Dimensions (EAB1-95) | 350 × 270 × 210 mm |
| Weight (EAB1-95) | 9 kg |
| Dimensions (EAB1-2000) | 410 × 264 × 110 mm |
| Weight (EAB1-2000) | 10 kg |
| Power Consumption | 37 W (EAB1-95), 40 W (EAB1-2000) |
| Transmittance Stability (EAB1-2000) | ≤0.3% T/5 min (bright), ≤0.2% T/5 min (dark) |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Pawkit |
| Price Range | USD 1,400–7,000 (est.) |
| Sensor Type | Capacitive Hygrometric Sensor |
| Accuracy | ±0.02 aw |
| Resolution | ±0.01 aw |
| Measurement Range | 0.00–1.00 aw |
| Repeatability | ±0.01 aw (typical, per AOAC 978.17) |
| Sample Cup Volume | 7 mL (max. 15 mL) |
| Measurement Time | < 5 min |
| Display | 6-digit custom LCD (3-digit aw + 3-digit °C) |
| Dimensions | 6.6 × 10.7 × 2.0 cm |
| Weight | 115 g |
| Power Supply | Two 3 V CR2032 lithium coin cells (3-year typical service life) |
| Operating Environment | 4–60 °C |
| Certifications | CE Marked |
| Warranty | 1 year parts & labor (extendable) |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Model | 4TE DUO |
| Sensor Type | Mirror Condensation Dew Point Sensor |
| Accuracy (aw) | ±0.003 aw |
| Resolution (aw) | ±0.0001 aw |
| Measurement Range (aw) | 0.1000–0.9500 aw |
| Repeatability (aw) | ±0.001 aw |
| Moisture Content Resolution | ±0.01% |
| Moisture Content Repeatability | ±0.02% |
| Temperature Control Range | 15–50 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.01 °C |
| Sample Volume | 7 mL (max 15 mL) |
| Measurement Time | <5 min (avg. 2.5 min) |
| Data Storage Capacity | 8,000 readings |
| Display | 128×64 pixel backlit LCD |
| Interface | RS-232, USB |
| Dimensions | 26.7 × 17.8 × 12.7 cm |
| Weight | 3.18 kg |
| Power | 110–220 VAC, 50/60 Hz, <0.4 A |
| Operating Environment | 4–60 °C, 0–90% RH (non-condensing) |
| Certifications | CE |
| Warranty | 1 year (parts & labor) |
| Brand | Aqualab / METER Group |
|---|---|
| Origin | USA |
| Model | AquaLab Pre |
| Sensor Type | Mirror Condensation Dew Point (Standard), Capacitance (Optional) |
| Accuracy | ±0.01 aw (Dew Point), ±0.015 aw (Capacitance) |
| Resolution | 0.001 aw |
| Measurement Range | 0.05–1.000 aw |
| Repeatability | ≤ ±0.002 aw |
| Temperature Control | Fixed at 25.0 °C (±0.2 °C stability) |
| Temp. Resolution | 0.1 °C |
| Sample Volume | 7 mL recommended (max 15 mL) |
| Measurement Time | < 5 minutes |
| Display | 20-character alphanumeric backlit LCD |
| Interface | RS-232, USB |
| Dimensions | 24.1 × 22.9 × 8.9 cm |
| Weight | 3.2 kg |
| Power | 110–220 VAC, 50/60 Hz, < 0.4 A |
| Operating Environment | 4–60 °C, 0–90% RH (non-condensing) |
| Certifications | CE, AOAC Official Method 978.18 |
| Warranty | 1 year parts and labor |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Model | Aqualab 4TE |
| Sensor Principle | Mirror Condensation Dew Point |
| Accuracy | ±0.003 aw |
| Resolution | 0.0001 aw |
| Measurement Range | 0.030–1.000 aw |
| Repeatability | ±0.001 aw |
| Temperature Control Range | 15–50 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.01 °C |
| Sample Volume | 7 mL (max 15 mL) |
| Measurement Time | <5 min (avg. 2.5 min) |
| Data Storage Capacity | 8,000 secure readings with timestamp, user ID, and calibration logs |
| User Accounts | Up to 25 configurable usernames/passwords |
| Interface | RS-232, USB |
| Display | 128×64-pixel backlit LCD |
| Dimensions | 26.7 × 17.8 × 12.7 cm |
| Weight | 3.18 kg |
| Power | 110–220 V AC, 50/60 Hz, <0.4 A |
| Operating Environment | 4–60 °C, 0–90% RH (non-condensing) |
| Certifications | CE, AOAC Official Method 975.13, FDA 21 CFR Part 11 compliant (audit trail, electronic signature support) |
Show next