- All
- Favorite
- Popular
- Most rated
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | HQH-150, HQH-250, HQH-400 |
| Temperature Range (with light) | 10–50°C |
| Temperature Range (dark) | 4–50°C |
| Temperature Uniformity | ±1°C |
| Temperature Resolution | 0.1°C |
| Humidity Range | 50–90% RH |
| Humidity Deviation | ±5–7% RH |
| Light Intensity | 0–12,000 lx (HQH-150), 0–15,000 lx (HQH-250), 0–25,000 lx (HQH-400), 6-level adjustable |
| Power Input | 2300 W / 2500 W / 3200 W |
| Chamber Volume | 150 L / 250 L / 400 L |
| Internal Dimensions (W×D×H, mm) | 500×400×750 / 580×500×850 / 680×550×1050 |
| External Dimensions (W×D×H, mm) | 700×640×1480 / 780×745×1560 / 880×780×1810 |
| Standard Shelves | 3 pcs |
| Continuous Operation Capability | ≥360 h |
| Ambient Operating Conditions | 5–30°C, ≤80% RH |
| Brand | Panasonic |
|---|---|
| Origin | Japan |
| Model | MDF-U74V |
| Instrument Type | Upright |
| Effective Capacity | 728 L |
| Internal Dimensions (W×D×H) | 870 × 600 × 1400 mm |
| External Dimensions (W×D×H) | 1010 × 870 × 2010 mm |
| Power Supply | 220 V |
| Rated Power | 1100 W |
| Temperature Range | –50 °C to –86 °C (1 °C increments) |
| Compressor | Hermetic, dual-stage |
| Refrigerant | HFC blend |
| Net Weight | ~346 kg |
| Shelving | 3 stainless-steel shelves |
| Monitoring Ports | 3 × Ø17 mm (rear + lower left/right corners) |
| Alarm System | High/Low temperature, power failure, filter clog, door open, self-diagnostic, component replacement alert |
| Remote Alarm Contact Rating | DC 30 V, 2 A |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (PRC-manufactured) |
| Models | JY200C, JY300C, JY600C, JY1000C, JY1600C |
| Instrument Type | Protein Electrophoresis Power Supply |
| Gel Format Compatibility | Standard vertical mini-gels (e.g., 8 × 10 cm), horizontal gels, and blotting modules |
| Sample Capacity | Up to 10 samples per run |
| Output Range | 1–200 W (JY200C) to 1–300 W (JY600C/JY1000C) / 1–160 W (JY1600C) |
| Voltage Range | 5–200 V (JY200C) to 20–1600 V (JY1600C) |
| Current Range | 1–2000 mA (JY200C) to 1–1600 mA (JY1600C) |
| Resolution | 1 V / 1 mA / 1 W |
| Timer | 1 min – 99 h 59 min |
| Display | Backlit LCD (128 × 64 pixels) |
| Dimensions (L×W×H) | 28×24×11 cm (JY200C/JY300C), 27×26×12 cm (JY600C/JY1000C/JY1600C) |
| Weight | 3.2 kg (JY200C/JY300C), 6.8–7.7 kg (JY600C–JY1000C) |
| Brand | Panasonic |
|---|---|
| Origin | Japan |
| Model | MDF-193 / MDF-594 / MDF-794 |
| Instrument Type | Upright |
| Effective Volume | 86 L |
| Internal Dimensions (W×D×H) | 750 × 700 × 945 mm |
| External Dimensions (W×D×H) | 750 × 700 × 945 mm |
| Power Supply | 220 V AC |
| Rated Power Consumption | 450 W |
| Temperature Range | –50 °C to –86 °C (adjustable in 1 °C increments) |
| Temperature Sensor | Pt100 platinum resistance thermometer |
| Control System | Microprocessor-based digital controller with dual-stage cascade refrigeration |
| Insulation | In-situ foamed rigid polyurethane (≥120 mm thickness) |
| Cabinet Construction | Exterior — pre-painted steel |
| Compressor Configuration | Two-stage hermetic scroll compressors (high-stage & low-stage) |
| Alarm Functions | High/low temperature deviation (±5 °C to ±20 °C adjustable), power failure, door ajar, condenser filter clog (MDF-594/MDF-794 only), remote alarm contact output |
| Net Weight | 103 kg |
| Brand | NIKON |
|---|---|
| Origin | Japan |
| Model | E200 Trinocular |
| Optical System | CFI60 Infinity-Corrected |
| Observation Head | Trinocular (E2-TF), 30° Inclination, Interpupillary Distance 47–75 mm |
| Eyepieces | CFI 10×/20 mm Field Number (FN) |
| Objective Lenses | CFI E Plan Achromat 4×, 10×, 40×, 100× (anti-fungal coated) |
| Nosepiece | Inclined 4-position Revolving Nosepiece |
| Condenser | E2 Abbe Condenser, NA 1.25 |
| Focusing Mechanism | Coaxial Coarse/Fine Focus, Fine Focus Graduation 2 µm, Coarse Travel 37.7 mm/rev, Fine Travel 0.2 mm/rev |
| Stage | Rectangular Mechanical Stage, 216 × 150 mm, Travel Range 78 × 54 mm |
| Illumination | LED Light Source (60,000 hr lifetime), Constant CCT Across Intensity Range, IR-Free, Low Heat & Power Consumption |
| Anti-Fungal Protection | Internal Anti-Mold Coating + Desiccant Mold-Prevention Strips (validated for 3 years at 30°C / 80% RH) |
| Ergonomics | Adjustable Tilting Eyepiece Tube (±30°), Height-Optimized Stage Controls, Low-Profile Knob Placement |
| Compatibility | CFI60 Objective Mount, Full Eclipse Series Accessory Ecosystem (Phase Contrast, Fluorescence, Polarization, Digital Imaging) |
| Brand | Panasonic |
|---|---|
| Origin | Japan |
| Model | MDF-U5386S / MDF-U7386S |
| Instrument Type | Upright |
| Effective Volume | 483 L |
| Interior Dimensions (W×D×H) | 630 × 600 × 1280 mm |
| Exterior Dimensions (W×D×H) | 890 × 875 × 1990 mm |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 750 W |
| Operating Temperature | –86 °C |
| Temperature Range (at 30 °C ambient) | –50 to –86 °C |
| Net Weight | 305 kg |
| Refrigerant | HFC (R-407D for high-stage, R-508B for low-stage) |
| Compressor Configuration | Dual independent cascade compressors with inter-stage heat exchanger |
| Door Seal System | Triple independent gaskets (two compression-type + one magnetic) |
| Interior Material | Epoxy-coated polypropylene-clad stainless steel |
| Control System | Microprocessor-based digital controller with large green LCD display |
| Alarms | Temperature deviation, power failure, filter clogging, compressor performance degradation, door ajar |
| Remote Alarm Interface | Yes |
| Status Monitoring Button | Yes |
| Casters | 4 (2 height-adjustable) |
| Access Ports | 3 × Ø17 mm (rear panel: 1, left/right side panels: 1 each) |
| Shelf System | 3 independently adjustable shelves |
| Brand | Panasonic |
|---|---|
| Origin | Japan |
| Model | MCO-5AC, MCO-18AC |
| Temperature Control Range & Accuracy | +5°C to 50°C (ambient: 5°C–35°C) |
| Temperature Uniformity | ±0.25°C (at 25°C ambient, 37°C setpoint, 5% CO₂, 5% O₂, no load) |
| Humidity Control Method | Natural evaporation via stainless steel humidification pan |
| Internal Volume | 49 L (MCO-5AC), 170 L (MCO-18AC) |
| CO₂ Control | On/off control with TC sensor |
| CO₂ Range | 0–20% |
| CO₂ Stability | ±0.15% (at 25°C ambient, 37°C setpoint, 5% CO₂, no load) |
| Humidity Level | 95 ± 5% RH (at 20°C ambient, 60% RH) |
| UV Lamp | Optional 4 W ozone-free ultraviolet lamp |
| Filtration | 0.3 µm CO₂ inlet filter (99.97% efficiency) |
| Alarm Functions | High/low temperature, CO₂ deviation, door open, low water level (MCO-5AC), independent overheat protection |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | OS-20 / OS-30 |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Frequency | OS-20: 50–300 rpm |
| OS-30 | 50–250 rpm |
| Orbit Diameter | 20 mm (OS-20), 30 mm (OS-30) |
| Load Capacity | 2 kg |
| Temperature Range | 4–45 °C |
| Platform Quantity | 1 |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Shanghai Shiping |
|---|---|
| Origin | Shanghai, China |
| Model | ZHWY-100D / ZHWY-103D / ZHWY-200D |
| Timer Range | 0–500 min |
| Oscillation Frequency | 30–600 rpm |
| Amplitude Adjustment | 0–50 mm, continuously variable |
| Temperature Control Range | ZHWY-100D/ZHWY-103D: Ambient +5°C to 60°C |
| ZHWY-200D | 4°C to 60°C |
| Temperature Uniformity | ≤ ±1°C (at 37°C) |
| Temperature Stability | ≤ ±0.5°C (at 37°C) |
| Temperature Resolution | 0.1°C |
| Orbit Diameter | Φ0–50 mm |
| Platform Quantity | 1 |
| Drive Type | Orbital (track-driven) |
| Control System | PID microprocessor-based environmental scanning chip |
| Display | Backlit LCD |
| Power Supply | AC 220 V, 50/60 Hz |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | Shiping |
|---|---|
| Origin | Shanghai, China |
| Model | SPH-1112D / SPH-2112D |
| Temperature Range | 4 °C to 60 °C (SPH-2112D: 6 °C to 60 °C) |
| Oscillation Frequency | 50–300 rpm |
| Oscillation Amplitude | Φ35 mm (SPH-1112D) / Φ50 mm (SPH-2112D) |
| Timer Range | 0–500 h |
| Shelf Quantity | 2 |
| Power Consumption | 1100 W / 1340 W |
| Refrigerant | CFC-Free R134a |
| Control System | PID microprocessor with LCD dual-display |
| Safety Certifications | Over-temperature/over-speed alarm, independent thermal cutoff, door-open shutdown, leakage & overcurrent protection |
| Compliance | Designed for GLP-compliant labs |
| Brand | Shanghai Shiping |
|---|---|
| Origin | Shanghai, China |
| Model | SPH-2102C |
| Instrument Type | Full-Temperature Orbital Shaker |
| Timer Range | 0–999 h |
| Oscillation Frequency | 30–300 rpm |
| Orbit Diameter | 25 mm |
| Temperature Range | 4–60 °C |
| Number of Shaking Platforms | 2 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SPH-103D |
| Timer Range | 0–500 h |
| Oscillation Frequency | 30–600 rpm |
| Orbit Diameter | Φ0–50 mm |
| Temperature Range | Ambient +5°C to 60°C |
| Platform Quantity | 1 |
| Control System | PID microprocessor with LCD dual-display (setpoint & real-time) |
| Drive Mechanism | Patented single-axis balanced drive |
| Cooling System | CFC-free R134a refrigerant |
| Heating Power | 150 W |
| Motor | AC induction, brushless, maintenance-free |
| Safety Features | Over-temperature/over-speed audiovisual alarm, independent thermal cutoff, lid-open stop, auto-restart after power recovery |
| Platform Size | 260 × 260 mm |
| Capacity | 9 × 100 mL or 4 × 250 mL flasks |
| Internal Chamber | 360 × 340 × 280 mm (W×D×H) |
| Net Weight | 31 kg |
| Power Supply | AC 200–240 V, 50–60 Hz |
| Compliance | CE-marked design principles |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Models | BSC-1600III / BSC-1300III / BSC-1000III |
| Price Range | USD 14,000 – 28,000 |
| Cabinet Class | Class III (Total Enclosure, Glove-Box Type) |
| External Dimensions (L×W×H) | 2150 × 620 × 1980 mm |
| Internal Work Area (L×W×H) | 1600 × 600 × 650 mm |
| Filter Efficiency (HEPA/ULPA) | ≥99.999% at 0.12 µm (EN 1822 H14 equivalent) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | ZHWY-110X30 |
| Timing Range | 0–500 h |
| Oscillation Frequency | 20–180 rpm |
| Oscillation Amplitude | 16 mm (factory-set) or 24 mm (configurable) |
| Temperature Range | Ambient to 99.9 °C |
| Temperature Uniformity | ±0.2 °C at 37 °C / 100 rpm |
| Temperature Resolution | ±0.1 °C |
| Tray Quantity | 1 |
| Power | 1600 W (ZHWY-110X30) / 2300 W (ZHWY-110X50) |
| Input Voltage | AC 220 V, 50/60 Hz |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UP50H |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 50 W |
| Operating Frequency | 30 kHz |
| Amplitude Control Range | 20–100% |
| Pulse Mode | 0–100% duty cycle |
| Sample Volume Capacity | 0.1–500 mL |
| Dimensions (L×W×H) | 180 × 130 × 50 mm |
| Weight | 1.1 kg |
| Power Supply | 230 V, 0.63 A, 50–60 Hz |
| Probe Material | Grade 5 Titanium Alloy (Ti-6Al-4V) |
| Cooling Options | Optional jacketed flow cell or transparent acoustic enclosure |
| Brand | ShiPing |
|---|---|
| Origin | Shanghai, China |
| Model | SPH-2102 |
| Temperature Range | 4°C to 60°C |
| Oscillation Frequency | 40–300 rpm |
| Orbit Diameter | 25 mm |
| Timer Range | 0–500 hours |
| Shelf Quantity | 2 |
| Power Consumption | 1200 W |
| Net Weight | 235 kg |
| Internal Chamber Dimensions (W×D×H) | 850 × 520 × 760 mm |
| External Dimensions (W×D×H) | 950 × 740 × 1400 mm |
| Control System | PID microprocessor with LCD dual-display |
| Cooling System | CFC-free R134a refrigerant |
| Safety Compliance | Over-temperature/over-speed audiovisual alarm, independent thermal cutoff, door-open stop, leakage current protection, auto-restart after power recovery |
| Brand | Shen'an / She Medical Devices |
|---|---|
| Origin | Shanghai, China |
| Model | LDZM-80KCS (Intelligent Type) |
| Chamber Volume | 80 L |
| Power Supply | 220 V AC |
| Heating Power | 3 kW |
| Net Weight | 65 kg |
| External Dimensions | 620 × 520 × 1250 mm |
| Chamber Dimensions | Φ355 × 800 mm |
| Sterilization Temperature Range | 50–134 °C |
| Time Setting Range | 0–99 h |
| Safety Features | Interlocked door mechanism, low-water cutoff protection, internal exhaust system, audible end-of-cycle alarm, automatic shutdown |
| Optional Accessories | Thermal printer module, vacuum drying unit |
| Construction | 304 stainless steel chamber and exterior housing |
| Door Mechanism | Rotating quick-release lid |
| User Interface | Digital LCD display with Chinese-language menu and one-touch parameter entry |
| Brand | Panasonic (Sanyo) |
|---|---|
| Origin | Japan |
| Model | MCO-5M, MCO-18M |
| Temperature Range & Accuracy | +5°C to 50°C (ambient: 5–35°C) |
| Temperature Uniformity | ±0.25°C (at 25°C ambient, 37°C setpoint, 5% CO₂, 5% O₂, no load) |
| Temperature Stability | ±0.1°C |
| CO₂ Control Range | 0–20% |
| CO₂ Control Accuracy | ±0.15% |
| O₂ Control Range | 1–18%, 22–80% |
| O₂ Control Accuracy | ±0.2% |
| Humidity Method | Natural evaporation via stainless steel humidification pan |
| Relative Humidity | 95 ± 5% RH |
| Internal Volume | 49 L (MCO-5M), 170 L (MCO-18M) |
| External Dimensions (W×D×H) | 480 × 548 × 575 mm (MCO-5M), 620 × 710 × 900 mm (MCO-18M) |
| Net Weight | 50 kg (MCO-5M), 97 kg (MCO-18M) |
| Power Consumption | 205 W (MCO-5M), 330 W (MCO-18M) |
| Heating System | DHA (Direct Heating Air-jacket) with triple independent heating units (MCO-18M only) |
| Sensor Types | Thermal Conductivity (CO₂, MCO-5M), IR (CO₂, MCO-18M), Long-life electrochemical (O₂) |
| Interior Material | Antimicrobial copper-alloy stainless steel |
| UV Lamp | 4 W ozone-free (optional) |
| Filtration | 0.3 µm HEPA-grade gas filter (99.97% efficiency for CO₂/O₂ or CO₂/N₂ lines) |
| Alarm Functions | High/low temperature, CO₂/O₂ deviation, door open, UV lamp fault, independent overheat protection |
| Brand | Panasonic |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MDF-782 |
| Price Range | USD 14,000–28,000 |
| Configuration | Upright |
| Effective Volume | 706 L |
| Interior Dimensions (W×D×H) | 920 × 600 × 1280 mm |
| Exterior Dimensions (W×D×H) | 1080 × 875 × 1990 mm |
| Power Supply | 220 V, 50 Hz |
| Rated Power Consumption | 1170 W |
| Compressor Type | Dual hermetic compressors (1100 W each) |
| Refrigerant | R508B (ozone-friendly, low-GWP blend) |
| Temperature Range | –50 °C to –86 °C (0.1 °C adjustable resolution |
| Door Configuration | 1 outer door + 2 inner doors |
| Safety Features | High/low temperature alarm, power failure alarm, remote alarm contact output, sensor self-diagnosis, compressor protection circuit |
| Standard Accessories | 1 set of keys, 3 stainless-steel shelves, 1 defrost scraper |
| Monitoring Ports | 2 × Φ17 mm (rear + lower-left corner) |
| External Finish | Electrogalvanized steel with polyester powder coating |
| Internal Finish | Electrogalvanized steel with polyester powder coating |
| Net Weight | ~345 kg |
| Brand | Shiping |
|---|---|
| Origin | Shanghai, China |
| Model | SPH-100B |
| Timer Range | 0–500 h |
| Oscillation Frequency | 30–400 rpm |
| Orbit Diameter | 25 mm |
| Temperature Range | Ambient +5°C to 60°C |
| Shelf Quantity | 1 |
| Display | Dual-channel LCD with setpoint/actual value readout |
| Control System | PID microprocessor with environmental scanning algorithm |
| Drive Mechanism | Patented single-axis balanced drive |
| Cooling System | CFC-free R134a refrigerant |
| Heating Power | 150 W |
| Rated Power | 280 W |
| Chamber Material | Electropolished stainless steel (AISI 304) |
| External Housing | ABS engineering plastic |
| Safety Features | Dual-limit temperature/speed alarm, independent overtemperature cut-off, lid-open stop, motor overheat protection, auto-restart after power recovery |
| Compliance | CE-marked, conforms to IEC 61000-6-3 (EMC), IEC 61010-1 (Safety), and ISO 13485-aligned manufacturing practices |
| Brand | Shiping |
|---|---|
| Origin | Shanghai, China |
| Model | SPH-111B / SPH-211B |
| Instrument Type | Full-Temperature Orbital Shaker Incubator |
| Timer Range | 0–500 h |
| Oscillation Frequency | 50–300 rpm |
| Orbit Diameter | Φ25 mm |
| Temperature Range | 4°C–60°C (SPH-211B), Ambient +5°C–60°C (SPH-111B) |
| Shelf Capacity | 1 platform |
| Platform Dimensions | 920 × 500 mm |
| Max Load | 2000 mL × 10 flasks or equivalent volumetric configurations |
| Temperature Uniformity | ±0.5°C |
| Temp. Control Accuracy | ±0.1°C |
| Oscillation Accuracy | ±1 rpm |
| Refrigerant | R134a (CFC-free) |
| Heating Power | 800 W |
| Cooling Power | 200 W |
| Total Power Consumption | 960 W (SPH-111B), 1120 W (SPH-211B) |
| Motor | 120 W AC inverter motor |
| Safety Features | Independent overtemperature cutoff, door-open stop, leakage current protection, overcurrent protection, auto-restart after power recovery, acceleration-controlled soft start |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CFX96 Touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well |
| Heating Rate | 3.3°C/sec |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.4°C |
| Brand | ShiPing |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Full-Temperature Incubatory Shaker |
| Timer Range | 0–500 h |
| Oscillation Frequency | 50–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | Φ25 mm |
| Temperature Range | 4°C–60°C |
| Temperature Uniformity | ±0.25°C |
| Temperature Control Accuracy | ±0.1°C |
| Shelf Quantity | 2 |
| Chamber Dimensions (W×D×H) | 550 × 480 × 550 mm |
| Shelf Size | 456 × 450 mm |
| Max Capacity | 4 × 5 L flasks |
| Power Consumption | 960–1120 W |
| Refrigerant | CFC-Free R-134a |
| Cooling Power | 200 W |
| Heating Power | 800 W |
| Motor | 60 W AC Variable-Frequency Induction Motor |
| Safety Certifications | Compliant with IEC 61010-1 for Laboratory Equipment |
| Control System | PID Microprocessor with LCD Dual Display |
| Programming | 8-Stage Programmable Ramp Profiles |
| Compliance | GLP-Compatible Data Logging, FDA 21 CFR Part 11 Ready (via optional software module) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | BC-J80S with Pressure Relief Valve |
| Capacity | 80 L |
| Temperature Range | Ambient +2°C to 65°C |
| Temperature Uniformity | ±0.2°C |
| Temperature Resolution | 0.1°C |
| Temperature Stability (Fluctuation) | ±0.2°C |
| CO₂ Range | 0–20% (v/v) |
| CO₂ Sensor | Imported NDIR Infrared Sensor (Accuracy: ±0.1% FS) |
| Humidification Method | Natural Evaporation |
| Chamber Dimensions (W×D×H) | 460 × 530 × 645 mm |
| External Dimensions (W×D×H) | 550 × 510 × 830 mm |
| Power Supply | 220 V / 50 Hz |
| Input Power | 500 W |
| Standard Shelving | 2 Adjustable Stainless Steel Shelves |
| Interior Material | Mirror-Finish 304 Stainless Steel |
| Filtration | HEPA Filter (≥0.3 µm, Efficiency ≥99.998%) |
| Control Interface | LCD Display with Microprocessor-Based Dual-Loop Control |
| Communication Port | RS-485 (Standard), Compatible with Data Logging Systems |
| Sterilization | Built-in UV Lamp (254 nm) |
| Safety Features | Dual Independent Control Systems, Power-Outage Parameter Memory & Auto-Restore, Door-Open Compensation Algorithm |
Show next