| Brand | Truelab (Chu Bai) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Line | Domestic |
| Models | ZYC0004, ZYC0012, ZYC0022, ZYC0030, ZYC0045, ZYC0060, ZYC0090, ZYC0110 |
| Construction | Dual-layer 1.0 mm cold-rolled steel with 38 mm fire-insulated cavity |
| Compliance | OSHA 29 CFR 1910.106, NFPA 30, DIN EN 14470-1 (30/90 min), equipped with static grounding port, self-closing door mechanism (optional), 3-point联动 lock system, spill containment sump ≥50 mm, adjustable epoxy-coated shelves, lead-free porcelain enamel finish |
| Color Coding | Yellow (flammables), Red (combustibles), Blue (corrosives) |
| Door Type | Manual 180° swing or automatic self-closing (integrated overhead closer) |
| Shelf Adjustment | 60 mm pitch, spill-proof design |
| Weight Range | 35–270 kg |
| Capacity Range | 4–110 US gallons (15–410 L) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME104 |
| Readability | 0.1 mg |
| Max Capacity | 120 g |
| Pan Diameter | Ø90 mm |
| Repeatability | 0.1 mg |
| Linearity | ±0.2 mg |
| Stabilization Time (typical) | 2 s |
| Sensitivity to Temperature Drift | 2.0 ppm/°C |
| Net Weight | 4.5–4.7 kg |
| Calibration | Fully Automatic Internal Calibration |
| Compliance | ISO/GLP-compliant data logging (date/time stamp), supports audit-ready workflows |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | A15-290 |
| Humidity Control Range | 15–60% RH |
| Humidity Accuracy | ±3% RH |
| Temperature Accuracy | ±1°C |
| Control System | Humidity Manager V2 (digital logging & curve plotting) |
| Power Supply | 220 V AC |
| Internal Dimensions (W×D×H) | 598 × 645 × 524 mm |
| External Dimensions (W×D×H) | 600 × 695 × 642 mm |
| Capacity | 202 L |
| Shelf Quantity | 2 pcs |
| Shelf Size | 555 × 580 × 20 mm |
| Avg. Power Consumption | 5 W |
| Max. Power Consumption | 140 W |
| Compliance | Designed for GLP-compliant storage environments |
| Certifications | CE-marked per IEC 61000-6-3/6-4 (EMC), RoHS compliant |
| Brand | Panasonic |
|---|---|
| Origin | Japan |
| Model | MPR-514R, MPR-1014R |
| Temperature Range | 2°C to 14°C (ambient: −5°C to 35°C) |
| External Dimensions (W×D×H) | 900×600×1790 mm / 1800×600×1790 mm |
| Internal Dimensions (W×D×H) | 800×465×1300 mm / 1700×465×1300 mm |
| Net Volume | 489 L / 133 L |
| Net Weight | 141 kg / 243 kg |
| Power Consumption (220 V, 50 Hz) | 215 W / 320 W |
| Insulation | In-situ rigid polyurethane foam |
| Exterior | Pre-coated steel sheet |
| Interior | Stainless steel (SUS304) |
| Shelving | 5 wire shelves (20 kg/shelf) + 5 sliding shelves (20 kg/shelf) / 5 wire shelves (50 kg/shelf) + 10 sliding shelves (20 kg/shelf) |
| Door | Dual-pane low-emissivity glass doors with safety film |
| Cooling System | Forced-air circulation with hermetic compressor (200 W / 250 W) |
| Defrost System | Automatic demand-based hot-gas defrost with dual heating elements (73.8 W × 2 / 141 W) |
| Refrigerant | HFC blend (R134a or equivalent) |
| Temperature Control | Dual Pt100 sensors + microprocessor PID control |
| Alarm System | Audible/visual high/low temperature, door ajar, power failure, remote alarm contact |
| Optional | Data logging module with RS-485 interface compliant with FDA 21 CFR Part 11 audit trail requirements |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | VD-650-U / VD-650 |
| Price Range | USD 700 – 1,400 |
| Instrument Category | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO 5 (equivalent to Class 100 per Fed. Std. 209E) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single-user, front-access only |
| Airflow Pattern | Vertical downward laminar flow |
| Average Air Velocity | ≥0.3 m/s (continuously adjustable) |
| Illuminance | ≥300 lx |
| Power Supply | 220 VAC, 50 Hz, single-phase |
| Input Power | 250 W |
| Net Weight | 60 kg |
| Work Area Dimensions | 615 × 495 × 500 mm (W×D×H) |
| External Dimensions | 650 × 535 × 835 mm (W×D×H) |
| HEPA Filter Specification | 610 × 450 × 50 mm, single unit |
| Lighting | 14 W fluorescent lamp × 1 |
| UV Lamp | 8 W germicidal lamp × 1 |
| Microbial Contamination | ≤0.5 CFU/plate·hour |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SW-CJ-1FD |
| Airflow Type | Vertical Laminar Flow |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Average Air Velocity | 0.3–0.6 m/s (adjustable via 8-step digital control) |
| Noise Level | ≤62 dB(A) |
| Illumination | ≥300 lx |
| Microbial Recovery | ≤0.5 CFU/plate·hour (φ90 mm Petri dish) |
| Vibration Half-Peak | ≤3 µm (X/Y/Z axes) |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 0.3 kW |
| Net Weight | 200 kg |
| Work Area Dimensions | 1300 × 700 × 520 mm (W × D × H) |
| Overall Dimensions | 1460 × 700 × 1650 mm (W × D × H) |
| HEPA Filter Specification | 600 × 600 × 100 mm × 2 units |
| Fluorescent Lamp | 20 W × 1 |
| UV Germicidal Lamp | 20 W × 1 |
| Brand | Vitlab |
|---|---|
| Origin | Germany |
| Model Range | 10–500 mL |
| Calibration Type | “In” (TC), Ring-Graduated |
| Accuracy Class | DIN EN ISO 1042 Class A |
| Material | Perfluoroalkoxy (PFA) |
| Cap | PFA Screw Cap with Sealing Ring |
| Max. Sterilization Temp. | 121 °C (autoclave) |
| Max. Cleaning Temp. | 60 °C |
| Thermal Stability | –200 °C to +260 °C |
| Chemical Resistance | Resistant to concentrated acids/bases, oxidizers, hydrocarbons, ketones |
| Surface Property | Ultra-low adhesion, hydrophobic, non-porous, laser-etched batch traceability |
| Transparency | Optical-grade clarity for precise meniscus reading |
| Packaging | Individual blister or bulk in sealed polybag per size |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ECO 0.9 |
| Airflow Type | Vertical Laminar Flow |
| Cleanliness Class | ISO Class 5 (100-level) |
| Noise Level | <55 dB(A) |
| Rated User Capacity | 2 operators |
| Pre-filter | EN779 G3 coarse-to-medium dust filter |
| HEPA Filter | EN1822 H14 (≥99.995% @ 0.3 µm) |
| Work Surface Options | Melamine or 316 stainless steel |
| UV Lamp | Optional |
| Illumination | >1000 lx |
| Power Consumption | 270 W |
| Air Velocity Range | 0.15–0.25 m/s (low mode), 0.36–0.45 m/s (high mode) |
| Compliance | CE marked per 2006/95/EC (LVD), 2004/108/EC (EMC), 2011/65/EC (RoHS), 2006/121/EC (REACH) |
| EN 61010-1 | 2011, EN 61326:2006 |
| Certifications | GOST-R certified for CIS markets |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SW-CJ-1BU / SW-CJ-1CU |
| Cleanliness Class | ISO Class 5 (Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Average Air Velocity | 0.3–0.6 m/s (adjustable) |
| Noise Level | ≤62 dB(A) |
| Illumination | ≥300 lx |
| Microbial Recovery | ≤0.5 CFU/plate·hr (φ90 mm Petri dish) |
| Vibration Half-Peak | ≤0.3 µm (X/Y/Z axes) |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 0.15 kW (SW-CJ-1BU), 0.3 kW (SW-CJ-1CU) |
| Weight | 110 kg (SW-CJ-1BU), 200 kg (SW-CJ-1CU) |
| Work Area Dimensions | 910×480×570 mm (SW-CJ-1BU), 1570×480×570 mm (SW-CJ-1CU) |
| Overall Dimensions | 910×790×1380 mm (SW-CJ-1BU), 1570×790×1380 mm (SW-CJ-1CU) |
| HEPA Filter Specification | 820×600×100 mm ×1 (SW-CJ-1BU) |
| Fluorescent Lamp / UV Lamp | 20 W ×1 / 20 W ×1 (SW-CJ-1BU) |
| Brand | Panasonic |
|---|---|
| Origin | Japan |
| Model | MPR-721, MPR-721R |
| Temperature Range | +2°C to +14°C (ambient −5°C to 0°C) / +2°C to +23°C (ambient 0°C to 35°C) |
| Internal Volume | 684 L (MPR-721-PC), 671 L (MPR-721R-PC) |
| External Dimensions (W×D×H) | 770 × 830 × 1955 mm |
| Net Weight | 174 kg (MPR-721), 193 kg (MPR-721R) |
| Power Consumption | 280 W (220 V, 50 Hz) |
| Insulation | In-situ foamed rigid polyurethane |
| Refrigerant | HFC |
| Control System | Microprocessor-based thermistor controller with digital display (1°C resolution) |
| Air Circulation | Forced convection |
| Alarm Functions | High/low temperature, door open, backup memory, self-diagnosis, temperature lock, remote alarm contact, component replacement alert |
| Optional Accessories | MTR-G04 temperature recorder, MPR-S7 mounting kit, RP-G04 chart paper, PG-R pen, MTR-0621LH recorder, MPR-S30 kit, RP-06 paper |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME204 |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Linearity | ±0.2 mg |
| Stabilization Time (typical) | 2 s |
| Sensitivity to Temperature Drift | 2.0 ppm/°C |
| Pan Diameter | Ø90 mm |
| Net Weight | 4.5–4.7 kg |
| Internal Calibration | Yes |
| Built-in Applications | 10 (e.g., formulation, counting, density, % weighing, checkweighing, statistics) |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PHS-3C |
| Accuracy Class | 0.01 |
| pH Range | 0.00–14.00 pH |
| mV Range | −1999 to +1999 mV |
| pH Resolution | 0.01 pH |
| mV Resolution | 1 mV |
| pH Accuracy | ±0.01 pH ±1 digit |
| mV Accuracy | ±0.1% FS |
| Stability | ±0.01 pH ±1 digit / 3 h |
| Temperature Compensation | Manual, 0.0–60.0 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 300 × 220 × 90 mm |
| Weight | 1 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Fed. Std. 209E Class 100 @ ≥0.5 µm) |
| Airflow Pattern | Vertical Downward Laminar Flow |
| User Capacity | Single-Person, Single-Face |
| Average Air Velocity | 0.1–0.6 m/s (infinitely adjustable) |
| Microbial Contamination | ≤0.5 CFU/plate·hr (φ90 mm Petri dish) |
| Noise Level | ≤62 dB(A) |
| Illumination | ≥300 lux |
| Vibration Half-Peak Amplitude | ≤0.3 µm (X/Y/Z axes) |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 0.3 kW |
| Net Weight | 200 kg |
| Work Area Dimensions | 1570 × 480 × 570 mm (W×D×H) |
| Overall Dimensions | 1570 × 790 × 1380 mm (W×D×H) |
| HEPA Filter Specification | 549 × 1236 × 50 mm (1 unit) |
| Lighting | 30 W Fluorescent Lamp ×1 |
| UV Lamp | 40 W ×1 |
| Control Interface | LCD Display with Real-Time Parameter Monitoring (air velocity, filter status, timer, differential pressure) |
| Brand | Truelab |
|---|---|
| Model | X2E-290 |
| Capacity | 202 L |
| Internal Dimensions (W×D×H) | 598 × 645 × 524 mm |
| External Dimensions (W×D×H) | 600 × 695 × 642 mm |
| Shelf Quantity | 2 pcs |
| Shelf Size | 555 × 580 × 20 mm |
| Humidity Control Range | ≤5% RH |
| Humidity Accuracy | ±3% RH |
| Temperature Accuracy | ±1°C |
| Control System | Humidity Manager V2 (fully automatic, with digital temperature/humidity curve logging) |
| Power Supply | 220 V |
| Avg. Power Consumption | 55 W |
| Max. Power Consumption | 155 W |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME204E |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Linearity | ±0.2 mg |
| Stabilization Time (typical) | 2 s |
| Sensitivity to Temperature Drift | 2.0 ppm/°C |
| Pan Diameter | Ø90 mm |
| Net Weight | 4.7 kg |
| Calibration | Internal (built-in motorized calibration mass) |
| Compliance | ISO/IEC 17025, GLP, GMP (21 CFR Part 11-ready with optional software) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Models | ZYC0004B, ZYC0012B, ZTC0022B, ZYC0030B, ZYC0045B, ZYC0060B, ZYC0090B |
| Construction | 1.0 mm+ cold-rolled steel with continuous spot welding |
| Door Mechanism | Three-point联动 lock system, 180° full-opening door with dual-key access |
| Finish | Lead-free electrostatic epoxy powder coating (interior & exterior) |
| Compliance | OSHA 29 CFR 1910.106, NFPA 30, FM Approval Standards |
| Grounding | Integrated static grounding port per OSHA requirements |
| Spill Containment | 50 mm high leak-proof sump |
| Ventilation | Dual flame-arresting vents with self-closing dampers |
| Color | Standard safety blue |
| Optional Accessory | Polypropylene (PP) spill trays |
| Certifications | Designed for GLP-compliant laboratory environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME104E |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Linearity | ±0.2 mg |
| Stabilization Time (typical) | 2 s |
| Sensitivity to Temperature Drift | 2.0 ppm/°C |
| Pan Diameter | Ø90 mm |
| Net Weight | 4.5–4.7 kg |
| Calibration | Internal (one-key auto-calibration) |
| Built-in Applications | 10 (e.g., formulation, counting, density, % weighing, checkweighing, statistics) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SVF-1000 |
| Ultimate Vacuum Pressure | −0.08 MPa (200 mbar) |
| Positive Pressure Output | 0.10 MPa (1.0 bar) |
| Pressure Regulation Range | 0–0.1 MPa |
| Air Flow Rate | 25 L/min |
| Reverse-Blow Interval Setting | 0.1–99 s |
| Dimensions (L×W×H) | 270 × 310 × 240 mm |
| Weight | 5.5 kg |
| Power Consumption | 100 W |
| Input Voltage | 110–220 V, 50 Hz |
| Compliance | CE-marked design for laboratory use under IEC 61010-1 |
| Brand | Vitlab |
|---|---|
| Origin | Germany |
| Capacity Range | 10–1000 mL |
| Calibration Type | “In” (TC), individually calibrated per batch |
| Compliance | DIN EN ISO 1042 Class A |
| Material | Poly(methylpentene) (PMP) |
| Max Sterilization Temp | 121 °C (autoclavable) |
| Max Cleaning Temp | ≤60 °C |
| Traceability | Batch number and manufacturing date laser-etched |
| Neck Size | NS 10/14 to NS 24/29 |
| Height (excl. stopper) | 90–310 mm |
| Tolerance | ±0.04 mL (10 mL) to ±0.40 mL (1000 mL) |
| Brand | Panasonic |
|---|---|
| Model | MPR-310 |
| Temperature Range | 2°C to 8°C (ambient 5–30°C) |
| Effective Volume | 387 L |
| External Dimensions (W×D×H) | 660 × 650 × 1970 mm |
| Internal Dimensions (W×D×H) | 570 × 498 × 1405 mm |
| Net Weight | 126 kg |
| Rated Input Power | 295 W |
| Exterior Material | Powder-Coated Steel |
| Interior Material | Powder-Coated Steel |
| Door | Electrically Heated Low-E Glass with Anti-Fog Film |
| Compressor | Hermetic Type |
| Refrigerant | R134a |
| Safety Alarms | High-Temp, Low-Temp, Door-Open (>60 s), Sensor Fault, Condenser Blockage, Condenser Overheat |
| Standard Accessories | 1 × LED Lamp, 1 × Key Set, 5 × Adjustable Wire Shelves |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Models | SW-CJ-2F, SW-CJ-2FD, SW-CJ-1F, SW-CJ-1FD |
| Price Range | USD 1,400 – 2,800 (FOB China) |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO 5 (Class 100) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Dual-Operator, Single-Face Configuration |
| Airflow Pattern | Vertical Unidirectional Flow |
| Work Surface Velocity | ≥0.3 m/s (adjustable) |
| Illuminance | ≥300 lx |
| Power Supply | AC 220 V / 50 Hz, Single-Phase |
| Input Power | 500 VA |
| Net Weight | 170 kg |
| Working Area Dimensions | 1360 × 690 × 520 mm (W × D × H) |
| Overall Dimensions | 1500 × 750 × 1600 mm (W × D × H) |
| HEPA Filter Specification & Quantity | 610 × 610 × 50 mm, 2 units |
| Fluorescent Lamp / UV Lamp | 14 W × 2 / 5 W × 2 |
| Microbial Contamination | ≤0.5 CFU/plate (90 mm Petri dish, 1-hour exposure) |
| Compliance | GB/T 16292–2010, YY 0569–2011, ISO 14644-1:2015 |
| Brand | Panasonic (formerly Sanyo) |
|---|---|
| Origin | Japan |
| Model | MPR-514, MPR-1014 |
| Temperature Range | 2°C to 14°C (ambient: −5°C to 35°C) |
| External Dimensions (W×D×H) | 900 × 600 × 1790 mm (MPR-514) / 1800 × 600 × 1790 mm (MPR-1014) |
| Internal Dimensions (W×D×H) | 800 × 465 × 1300 mm (MPR-514) / 1700 × 465 × 1300 mm (MPR-1014) |
| Net Volume | 489 L (MPR-514) / 1033 L (MPR-1014) |
| Net Weight | 141 kg / 243 kg |
| Power Consumption | 215 W / 320 W (220 V, 50 Hz) |
| Insulation | In-situ rigid polyurethane foam |
| Exterior | Pre-coated steel |
| Interior | Stainless steel |
| Shelving | 5 × enameled wire shelves (50 kg capacity each) / 10 × enameled wire shelves (50 kg each) |
| Door | Dual-pane low-emissivity glass doors with safety film |
| Cooling System | Forced-air circulation with hermetic compressor (200 W / 250 W) |
| Defrost System | Intelligent frost-detection-based automatic defrost cycle with dual-purpose heating elements (defrost + anti-freeze protection) |
| Refrigerant | HFC blend |
| Temperature Control | Dual Pt100 sensors with microprocessor-based PID regulation |
| Alarms | Visual & audible high/low temperature, door ajar, power failure, remote alarm contact output |
| Optional | Data logging module with RS-485 interface compliant with FDA 21 CFR Part 11 audit trail requirements |