| Brand | Sartorius |
|---|---|
| Model | BSA124S-CW |
| Origin | Germany |
| Type | Analytical Balance |
| Max Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability | 1 mg |
| Calibration | Motorized Internal Calibration |
| Display | Backlit LCD (15 mm digit height) |
| Weighing Pan Diameter | Ø 90 mm |
| Interface | RS232 bidirectional |
| Compliance | ISO/GLP-compliant data output (with optional YDP03-0CE printer or PC connection) |
| Built-in Applications | Percentage weighing, net weight summation, animal/dynamic weighing, unit conversion, arithmetic functions (×, ÷) |
| Brand | SOPOTOP |
|---|---|
| Model Range | JA1003, JA1203, JA2003, JA3003, JA4103, JA5003 |
| Capacity | 100–500 g |
| Readability | 0.001 g (1 mg) |
| Repeatability | ±0.001 g |
| Linearity | ±0.002 g |
| Pan Diameter | Φ90 mm |
| Draft Shield Dimensions | 150 × 165 × 200 mm |
| Key | Brand: METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model Series | PL202L / PL402L / PL602L |
| Maximum Capacity | 200 g / 400 g / 600 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Linearity | ±0.02 g (typical for PL202L–PL602L class) |
| Calibration | External |
| Pan Diameter | Ø100 mm |
| Dimensions (W×D×H) | 238 × 335 × 287 mm |
| Interface | RS232 |
| Construction | ABS engineering plastic housing with in-use protective cover |
| Compliance | Designed to meet ISO 9001 manufacturing standards |
| Brand | SOPOTOP |
|---|---|
| Origin | Shanghai, China |
| Model | FA1004 |
| Maximum Capacity | 100 g |
| Readability | 0.1 mg |
| Repeatability | ±0.1 mg |
| Linearity | ±0.2 mg |
| Pan Diameter | 90 mm |
| Draft Shield Dimensions | 190 × 155 × 235 mm |
| Overall Dimensions | 200 × 440 × 290 mm |
| Calibration | External |
| Sensor Type | Electromagnetic Force Compensation |
| Interface | RS232 |
| Functions | Counting, Percentage Weighing, Unit Conversion (g, oz, ct), Auto-zero Tracking, Overload Protection, Self-diagnosis, Linear Correction, Factory Reset |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | BSA124S-CW / BSA224S-CW |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120 g / 220 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Calibration | Internal motor-driven calibration |
| Display | Backlit LCD (character height: 15 mm) |
| Level Indicator | Integrated adjacent to display |
| Pan Diameter | Ø 90 mm |
| Interface | RS232C bidirectional |
| Compliance | ISO/GLP-compliant data output (with optional YDP03-0CE printer or PC connection) |
| Built-in Applications | Percentage weighing, net weight summation, animal/dynamic weighing, unit conversion, arithmetic functions (×, ÷) |
| Brand | SOPTOP Hengping |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 200 g |
| Readability | 0.1 mg |
| Repeatability | ±0.1 mg |
| Linearity | ±0.2 mg |
| Calibration | External |
| Pan Diameter | 90 mm |
| Dimensions (W×D×H) | 365 × 223 × 338 mm |
| Draft Shield Size | 150 × 165 × 200 mm |
| Interface | RS232 |
| Environmental Compensation | Dynamic Temperature Compensation |
| Protection | Overload & Shock Protection |
| Functions | Piece Counting, Percentage Weighing, Unit Conversion (g, oz, ct), Auto-Zero Tracking, Factory Reset, Linear Correction |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | JJ100B / JJ200B |
| Instrument Type | Analytical Balance |
| Capacity | 110 g / 200 g |
| Readability | 0.001 g (1 mg) |
| Repeatability | ±0.001 g |
| Calibration Method | Manual internal calibration (100 g / 200 g standard weight required) |
| Pan Diameter | Ø105 mm |
| Dimensions (L×W×H) | 325 × 211 × 110 mm |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Operating Temperature | 0–40 °C |
| Operating Humidity | ≤80 % RH (non-condensing) |
| Interface | RS232 serial port |
| Tare Range | 0–110 g / 0–200 g |
| Verification Scale Interval (e) | 0.01 g (10d) |
| Construction | Aluminum alloy base with EMI-shielded internal housing |
| Features | Stainless steel weighing pan, 7-unit conversion (g, oz, ct, dwt, grain, lb, tl), piece counting (sample size: 1/10/20/50/100), underhook weighing capability, LCD display |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Type | Analytical Balance |
| Capacity | 210 g / 60 g (dual-range) |
| Readability | 0.1 mg / 1 mg |
| Repeatability | ±0.1 mg / ±1 mg |
| Linearity | ±0.2 mg / ±2 mg |
| Calibration | External |
| Pan Diameter | Ø90 mm |
| Draft Shield Dimensions | 150 × 165 × 200 mm |
| Overall Dimensions | 365 × 223 × 338 mm |
| Compliance | ISO/IEC 17025-ready, GLP/GMP-supporting design |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | BSA124S / BSA224S / BSA124S-CW / BSA224S-CW |
| Maximum Capacity | 120 g or 220 g |
| Readability | 0.1 mg |
| Calibration | External (BSA models) or Internal Motor-Driven (BSA-CW models) |
| Repeatability | ±0.1 mg |
| Display | Backlit LCD with 15 mm high characters |
| Level Indicator | Integrated adjacent to display |
| Weighing Pan Diameter | Ø 90 mm |
| Interface | RS232 bidirectional |
| Compliance | ISO/IEC 17025, GLP/GMP data traceability support (with optional printer or PC connection) |
| Built-in Applications | Percentage weighing, net weight summation, animal/dynamic weighing, unit conversion, arithmetic calculation (×, ÷) |
| Brand | Sartorius |
|---|---|
| Model | BSA124S |
| Capacity | 120 g |
| Readability | 0.1 mg |
| Calibration | External |
| Display | Backlit LCD with 15 mm character height |
| Weighing Pan Diameter | Ø 90 mm |
| Interface | RS-232C bidirectional |
| Compliance | ISO/GLP-compliant data output (with optional YDP03-0CE printer or PC connection) |
| Environmental Compensation | Advanced digital algorithm for stability under variable lab conditions |
| Operating Languages | 5 selectable (including English) |
| Level Indicator | Integrated adjacent to display |
| Key Functions | Percentage weighing, net weight summation, animal/dynamic weighing, unit conversion, arithmetic calculation (×, ÷) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | PL6001-L |
| Maximum Capacity | 6100 g |
| Readability | 0.1 g |
| Linearity | ±0.2 g |
| Repeatability | ±0.1 g |
| Pan Size | Ø160 mm |
| Calibration | External (with standard weights) |
| Power | AC adapter or batteries (25–30 h operation) |
| Weighing Units | g, kg, mg, ct, lb, oz, ozt, GN, dwt, momme, mesghal, tael, tical, tola, bath |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible operation |
| Application Modes | Standard, Percentage, Piece Counting, Dynamic Weighing, Accumulation, Checkweighing |