| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J90 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 420 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 32 GB internal SSD |
| Image/Video Storage | Up to 1,000 frames + 80 complete melting profiles |
| User Accounts | 20 configurable roles with password protection |
| Operating Interface | 7-inch TFT full-color touchscreen |
| Connectivity | USB 2.0, RS-232, Ethernet |
| Optical Magnification | 7× |
| Integrated Thermal Printer | Yes |
| Reference Standard Set Included | Yes |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J80 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min ramp rate |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 16 GB internal |
| Melting Curve Records | 600 traces |
| Video Recordings Stored | 20 full sequences |
| User Accounts | 10 configurable profiles |
| Imaging | High-definition CMOS video module (7× optical magnification) |
| Display | TFT true-color touchscreen |
| Connectivity | USB, RS-232, Ethernet |
| Power | 220 V AC, 50 Hz, 120 W |
| Operating Modes | Fully automated + manual override |
| Preloaded Methods | 40 validated protocols |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | JHD70 |
| Price Range | USD 4,200 – 7,000 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Sample Capacity | 4 capillaries per run (2 simultaneously analyzed) |
| Display | Dual-color LCD (3.5″ + 5.6″), >2.5× optical magnification |
| User Accounts | 15 |
| Predefined Methods | 100 |
| Data Interfaces | USB, RS232, Ethernet |
| GLP Compliance | Yes |
| Power Supply | 220 V, 50 Hz, 120 W |
| Standards Compliance | ASTM D3204, D3461, D3954, D6090 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | JH50, JH70, JH90 |
| Temperature Range | RT to 350 °C |
| Heating Rate | 0.1–20 °C/min (200-step adjustable) |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Resolution | 0.1 °C |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per batch |
| Display | TFT high-definition color LCD |
| Data Storage | 8 GB internal |
| Image Capture | Still frame capture with real-time video streaming |
| Video Playback | Local playback supported |
| Connectivity | USB, RS-232, Ethernet |
| Power Supply | 220 VAC, 50 Hz, 120 W |
| Magnification | 7× optical |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | D-1A |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Temperature Range | Ambient to 300°C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min |
| Temperature Repeatability | ±0.5°C at <200°C |
| Temperature Accuracy | ±0.1°C (calibrated against NIST-traceable reference) |
| Temperature Resolution | 0.1°C |
| Instrument Weight | 11 kg |
| Compliance | GB/T 8728–1988, ASTM E342, ASTM D36, ISO 4625, DIN 51801 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Y50 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–10 °C/min |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Accuracy | ±0.3 °C (at ~100 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, L 100 mm (dual-open) |
| Sample Capacity | 2 samples per run |
| Temperature Resolution | 0.1 °C |
| Cooling Method | Forced-air convection |
| Display | 7-inch TFT high-definition color screen |
| Data Storage | 8 GB internal + microSD card (up to 128 GB) |
| Connectivity | USB 2.0, RS-232, Ethernet |
| User Accounts | 8 configurable roles with password protection |
| Compliance Standards | SNT 0801.5–1999, GB/T 24892–2010, GB/T 12766–2008 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Y30 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–10 °C/min |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min heating rate) |
| Temperature Accuracy | ±0.3 °C (up to 100 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, L 100 mm (dual-open) |
| Sample Capacity | 2 samples per run |
| Temperature Resolution | 0.1 °C |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J30 |
| Price | USD 1,650 (FOB Shanghai) |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (≥250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 positions |
| Temperature Resolution | 0.1 °C |
| Display | 7-inch TFT true-color LCD |
| Data Storage | 200 test records (8 GB internal flash) |
| Video Magnification | 7× |
| Interface | USB 2.0, RS-232, 10/100 Mbps Ethernet |
| Power Supply | 220 V AC, 50 Hz, 120 W |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J50 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Storage | 8 GB internal flash memory |
| Data Storage Capacity | Up to 400 melting thermograms |
| Imaging | HD video capture module with 7× optical magnification |
| Display | TFT high-definition color touchscreen |
| Power Supply | 220 V AC, 50 Hz, 120 W |
| Interfaces | USB, RS-232, Ethernet |
| Operation Mode | Semi-automatic (automated temperature control, manual endpoint detection) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Y90 |
| Price Range | USD 1,400–2,800 |
| Temperature Range | 4–100 °C |
| Heating Rate | 0.1–10 °C/min |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Accuracy | ±0.3 °C (up to 100 °C) |
| Capillary Dimensions | OD 4 mm, ID 1.0 mm, L 100 mm (dual-open) |
| Sample Capacity | 2 samples per run |
| Temperature Resolution | 0.1 °C |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J70 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 8 GB internal flash |
| Image Storage | 400 frames |
| Video Recording | Yes (TFT-displayed real-time capture) |
| User Accounts | 8 configurable profiles |
| Display | TFT high-definition true-color LCD |
| Interface | USB, RS-232, Ethernet |
| Power | 220 V AC, 50 Hz, 120 W |
| Magnification | 7× optical |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | Y70 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–10 °C/min |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Accuracy | ±0.3 °C (up to 100 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, L 100 mm (dual-open) |
| Sample Capacity | 2 samples per run |
| Temperature Resolution | 0.1 °C |
| Compliance | SNT 0801.5–1999, GB/T 24892–2010, GB/T 12766–2008 |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | J370 |
| Price Range | USD 1,400–2,800 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | Not specified |
| Temperature Accuracy | ±0.3 °C |
| Temperature Resolution | 0.1 °C |
| Slide Dimensions | 76 × 19 × 1 mm / 15 × 15 × 0.5 mm |
| Field of View | 2 mm |
| Working Distance (Objective) | ≥7 mm |
| X–Y Translation Range | ≤13 mm |
| Dimensions (L×W×H) | 185 × 85 × 28 mm |
| Weight | 1 kg |
| User Profiles | 15 |
| Method Segments | 99 per method |
| Stored Methods | 20 |
| Data Storage Capacity | 400 test records |
| Interface Ports | USB, RS232, SD card slot, Ethernet |
| Display | TFT high-definition color LCD |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J60 |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min heating rate) |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Display | TFT high-definition color LCD |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 120 W |
| Data Interfaces | USB, RS-232, Ethernet |
| User Accounts | 8 configurable profiles |
| Melting Curve Storage | 10 complete thermal profiles |
| Total Data Storage | 400 melting events |
| Detection Mode | Fully automated optical detection (no manual override) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | J350 |
| Price Range | USD 1,400–2,800 (FOB) |
| Temperature Range | Ambient to 300 °C |
| Heating Rate | 0.1–20.0 °C/min |
| Temperature Repeatability | ±0.2 °C (typical, per ASTM E928-21) |
| Temperature Accuracy | ±0.3 °C (calibrated against NIST-traceable reference standards) |
| Temperature Resolution | 0.1 °C |
| Slide Dimensions | 76 × 19 × 1 mm (standard microscope slide), Coverslip: 15 × 15 × 0.5 mm |
| Field of View | 2 mm diameter |
| Working Distance (objective lens) | ≥7 mm |
| X–Y Translation Range | ≤13 mm |
| Dimensions (L×W×H) | 185 × 85 × 28 mm |
| Weight | 1.0 kg |
| Display | 4.3″ TFT true-color touchscreen |
| Interfaces | USB 2.0, RS-232, SD card slot, Ethernet (optional) |
| Method Storage | 10 pre-programmed thermal protocols |
| Data Logging Capacity | 200 complete thermal event records |
| User Management | None (single-user operation) |
| Segment Control | Single-ramp profile only |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | J40 |
| Price Range | USD 7,000–14,000 (FOB) |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Temperature Repeatability | ±0.1 °C at 0.1 °C/min heating rate |
| Temperature Accuracy | ±0.3 °C (<250 °C), ±0.5 °C (>250 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Sample Capacity | 2 positions (dual-channel simultaneous analysis) |
| Temperature Resolution | 0.1 °C |
| Display | TFT high-definition color LCD |
| Power Supply | 220 V AC, 50 Hz, 120 W |
| Data Interfaces | USB, RS-232, Ethernet |
| User Accounts | 8 configurable profiles |
| Melting Curve Storage | 10 full thermal profiles |
| Data Log Capacity | 200 test records |
| Detection Mode | Fully automated optical endpoint detection only (no manual override) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Opti-Melt100 |
| Price | ¥56,500 (CNY) |
| Temperature Range | −10 °C to 400 °C |
| Heating Rate | 0.1–20 °C/min (adjustable in 0.1 °C/min increments) |
| Temperature Repeatability | ±0.3 °C |
| Temperature Accuracy | ±0.3 °C (≤100 °C), ±0.5 °C (≤250 °C), ±0.8 °C (≤400 °C) |
| Capillary Outer Diameter | 1.4–2.0 mm |
| Sample Capacity | 2 capillaries simultaneously |
| Temperature Resolution | 0.1 °C |
| Heating Time | 10 min (50 °C → 350 °C) |
| Cooling Time | 10 min (350 °C → 50 °C) |
| Display | Touchscreen LCD |
| Interface | USB, RS-232 |
| Software | Melt-View™ (Windows-compatible) |
| Power Supply | AC 90–264 V |
| Operating Temperature | 0–40 °C |
| Weight | 4.1 kg |
| Dimensions | 20 × 25 × 21 cm |